Honeywell SS431P Installation Instructions Manual

Installation Instructions for the
ISSUE 1
SS431P Hall Effect Sensor
ABSOLUTE MAXIMUM RATINGS*
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
SOLDERING/ASSEMBLY
Leads must be adequately supported during any
forming/ shearing operation to ensure that the leads are not stressed inside the plastic case. Recom­mended PC board wave soldering temperature is 250 to 260 maximum.
OPERATING CHARACTERISTICS
Supply voltage 3.8 24 VDC ICC Operate ICC Released ICC Ratio (Op/Rel)
Output switching time Rise, 10 to 90% Fall, 90 to 10%
Operating Temperature -55 to +160°C (-67 to +320°F)
o
C (482 to 500oF) for 3 seconds
Min. 25°C
11 15 20 mA
46 9mA
2.0 2.5 4.0 mA
 
Target
30 µs 30 µs
Supply voltage -1 to +30 VDC Voltage externally
applied to output Output ON current 50 mA max. Storage Temperature -65 to +160°C (-85 to +320°F) Magnetic flux No limit. Circuit cannot be
*Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings.
NOTICE
Interruption of power to a bipolar or latching device may cause the output to change state when power is restored. If a magnetic field of sufficient strength is present, the sensor output will be in the condition dictated by the magnetic field.
NOTE: The SS431P is a 2-wire, current output sensor.
Max. Remarks
 
V
CC
CL = 33 nF, CS = 330 pF
PK 80076
+30 VDC max. (OFF only)
-0.5 VDC min. (OFF or ON)
damaged by magnetic overdrive.
= 12 V. RL = 300 ,
MAGNETIC SPECIFICATIONS
Temperature Range -40°C 0°C 25°C 85°C 125°C 150°C Max. Operate Gauss 70 65 60 60 65 70 Min. Release Gauss -70 -65 -60 -60 -65 -70 Min. Differential Gauss 15 15 15 12 12 10
HONEYWELL Sensing and Control
SS431P Hall Effect Sensor
BLOCK DIAGRAM
GAUSS VS. TEMPERATURE
ISSUE 1
PK 80076
2 Honeywell Sensing and ControlFor application help: call 1-800-537-6945