Honeywell R8810A1018 Installation Guide

R8810A1018 Installation Guide
Wireless Receiver for OpenTherm® appliances
1
NOTE: The R8810A contains no user serviceable
WARNING: Electrostatic sensitive device! Do not touch the circuit board.
NOTE: All wiring must be in accordance with IEE regulations
CAUTION: Observe ambient temperature and current limits (see the R8810A wiring label)
2
3 4
OpenTherm® - communication
The CM957 can be connected to other OpenTherm appliances. For the correct wiring connections refer to the installation manual of the OpenTherm device.
R8810A
W6560C
7 8
max. 30m. 2 x 0.5mm2 ; 2 x 0.8mm
2
W6560C
50034666-001 B
Checking communication of system
1. Check the R8810A is powered by looking at the LED. It will blink red once per second.
2.
Check that there is sufficient signal strength from the Wireless Programmable Room Thermostat by performing the following check:
Hold the Wireless Programmable Room Thermostat about 2-3 metres from the installed R8810A. Switch the Wireless Programmable Room Thermostat to the OFF mode then press
the and buttons together with the button for 3 seconds. The Wireless Programmable Room Thermostat will send test signals to the R8810A, flashing the green LED on every 6 seconds (relay output will remain off) for a maximum of 10 minutes. When the green LED flashes on every 6 seconds proceed to the next step.
Binding a new wireless component
1. Switch the Wireless Programmable Room Thermostat to the OFF mode.
2. Hold button on R8810A for 5 seconds. Red light will blink 1/2 second on and 1/2 second off when the device is in binding mode.
3. Hold
, and program down buttons for 2 seconds. Display will show “InSt CO”, with a line of text “CONTROL BINDING”. The boiler and RF signal icons will be displayed.
4. Press green
button.
5. When Red LED on R8810A goes off, the devices are bound.
If binding is unsuccessful, then the LED will
stay on. In this case, move the Wireless Programmable Room Thermostat and repeat the binding procedure from the beginning.
6. Once binding is complete, switch the Wireless
Programmable Room Thermostat back to the AUTO mode, the LED on the R8810A will flash
green every 10 seconds to indicate that the device is live.
Communications Loss
If the communication is lost for a period of 1 hour the red LED will flash to indicate that no messages have been received during the last hour.
In the event of a communication loss signal, then please check the following and remedy as necessary:
1. Check the wiring between the W6560C system controller and correct if a fault is found.
2. Check the RF communication between the Wireless Programmable Room Thermostat using the method described above, and follow the check and binding procedure.
NB: If a wireless outdoor temperature sensor type HB85 is installed, check the batteries and replace as necessary before following the communication loss procedure.
Electrical Guidance and Safety
• The R8810A has been manufactured in accordance with the following standards:
EN60730-1, EN60730-9
• When performing any work with this product
(installation, mounting, start-up), all instructions given by the manufacturer and in particular the safety instructions provided in the Installation instructions must be followed.
• Ensure that the R8810A wireless receiver is installed by a competent person.
• Ensure that the R8810A wireless receiver is installed according to local electrical regulations.
• Ensurethat lowvoltagesignal cablesarekept
as far apart as possible from AC mains voltage cables.
• If the R8810A is modified in any way, except by the manufacturer, all warranties concerning operation and safety are invalidated.
50034666-001 B © 2009 Honeywell International Inc.
Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.
Honeywell Control Systems Ltd.
Newhouse Industrial Estate,
Motherwell
Lanarkshire
ML1 5SB
www.honeywell.com