Honeywell P658 Catalog Page

Pneumatic Switches
P658 Pneumatic/Electric Switch
Pneumatic-electric switches (P658A,B,E and F) used to convert a pneumatic signal from a controller to an electrical switching action (SPDT) to provide start and stop control of equipment such as fans and pumps.
Replacement devices available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell pneumatic/electric switches.
• Models available for surface or panel mounting.
• Barb protected by open cage.
• All ferrous parts plated to prevent corrosion.
• Factory calibrated setpoint field adjustable to meet job requirements.
• Neoprene diaphragm element.
Air Connections: Barb fitting for 1/4 in. (6 mm) O.D. plastic tubing Frequency: 60 Hz Operating Humidity Range: 5 to 95% RH, 80 F (27C) max wet bu b Temperature Range: 40 F to 140 F (4 C to 66 C) Maximum Safe Operating Pressure: 30 psi (207 kPa) Pilot Duty Ratings: 750 VA @ 125, 250 or 277 Vac Switch Operation: Converts pneumatic signal to electrical switching
action (SPDT)
Differential Pressure
Product Number Mounting
P658A1013/U Surface (includes
P658B1012/U Panel mount Screw
P658E1001/U Panel mount 1/4 in. quick-
P658E1167/U Panel mount 1/4 in. quick-
P658F1000/U Panel, through
case)
double D hole secured with hex nut
Electrical Connections
Screw terminals
terminals
connect male terminals
connect male terminals
1/4 in. quick­connect male terminals
Range
2 psi 14 kPa 2 to 24
2 psi 14 kPa 2 to 24
1 psi 7 kPa 2 to 17
1 psi 7 kPa 2 to 25
1 psi 7 kPa 2 to 17
Switch Type: Pneumatic/Electric Switch Switching Action:
P658A,B: Make R-W on pressure rise to setpoint plus differential; Make R-B on pressure fall to setpoint P658E,F: Make COM-NC on pressure fall to setpoint; Make COM-NO on pressure rise to setpoint plus differential
Approvals: Underwriters Laboratories, Inc:
Setpoint Range (Field
Category SDFY or SDFY2
Adjustable)
Motor Load Resistive Load Calibration Includes(psi) (kPa) (psi) (kPa)
psi
psi
psi
psi
psi
14 to 165 kPa
14 to 165 kPa
14 to 117 kPa
14 to 172 kPa
14 to 117 kPa
1 hp @ 125 Vac, 2 hp @ 250 or 277 Vac
1 hp @ 125 Vac, 2 hp @ 250 or 277 Vac
3/4 hp @ 125, 250 or 277 Vac
3/4 hp @ 125, 250 or 277 Vac
3/4 hp @ 125, 250 or 277 Vac
25A @ 125, 250 or 480 Vac
25A @ 125, 250 or 480 Vac
25A @ 125, 250 or 277 Vac; 10A @ 480 Vac
25A @ 125, 250 or 277 Vac; 10A @ 480 Vac
25A @ 125, 250 or 277 Vac; 10A @ 480 Vac
Factory Cal brated at 10 psi
Factory Cal brated at 10 psi
No Factory Cal bration
No Factory Cal bration
No Factory Cal bration
Case
690 customer.honeywell.com 70-6910
Pneumatic Switches
P E RELAY
P658A 1005 I
PRE SET 4 PSI
1
1
(25)
1 1/8
(29)
1 7/8
(48)
5 3/8
(11)
7/16
(11)
3 3/4
(95)
3 3/8
(86)
1
(25)
THREADED BARB PROTECTOR 5/8 18 UNF 2A MALE THREAD
KNOCKOUT ON ONE SIDE FOR 3/4 1NCH CONDUIT. KNOCKOUTS ON OPPOSITE SIDE, TOP, AND BACK FOR 1/2 INCH CONDUIT.
C7435
1
C7431
3 7/16
(87)
7/16
(11)
THREADED BARB PROTECTOR 5/8 18 UNF 2A MALE THREAD
3 1/4
(83)
1 7/8
(48)
1 1/2
(38)
2 5/8
(67)
C7432
3 5/16
(84)
19/64
(8)
15/64
(6)
15/64
(6)
5/8
(16)
2 7/8
(73)
1 3/4
(44)
1 1/4
(32)
1 1/4
(32)
M5436
TO CONTROL SIDE OF FAN MOTOR STARTER
B W R
TO OTHER CONTROLLED DEVICES
CONTROLLER BRANCH LINE
P658A Dimensions in inches (millimeters)
P658B Dimensions in inches (millimeters)
P658E Dimensions in inches (millimeters)
P658F Dimensions in inches (millimeters)
2 7/8
(73)
3/4
(19)
Pneumatic
1 1/4
(32)
2 3/4
(70)
7/16
(11)
THREADED BARB PROTECTOR 5/8 18 UNF 2A MALE THREAD
C7434
P658 Typical Piping
70-6910 691
Controls