Honeywell MO08CESWS, MO08CESWK, MO08CESWB, MO10CESWS, MO10CESWK, MO10CESWB User manual
EN
Portable Air Conditioner
User Manual
Read and save these instructions before use
FR
Climatiseur portatif
Mode d’emploi
Lire ces consignes avant l’utilisation de l’appareil et les conserver
ES
Aire Acondicionado Portátil
Manual Del Propietario
Lea y guarde estas instrucciones antes de usar la unidad
Model / Modèle / Modelo:
MO08CESWS, MO08CESWK, MO08CESWB
MO10CESWS, MO10CESWK, MO10CESWB
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
USA/ EE.UU: 18004742147
CANADA/ CANADÁ^ : 18882090999
^ Canada Customer Support service available for models sold in Canada only.
^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien.
^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
www.jmatek.com
Email: usinfo@jmatek.com
MO08 Series / Série / Serie:
MO10 Series / Série / Serie:
SAFETY
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND
KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY
INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH
VERSION AND ANY OTHER LANGUAGE VERSION OF THE
CONTENT OF THIS MATERIAL, THE ENGLISH VERSION
SHALL PREVAIL.
WARNING:
ť
DO NOT operate the unit with a damaged plug or loose wall
outlet. If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
ť
DO NOT cover the air intake and exhaust when in use.
ť
DO NOT place objects on or sit on the unit.
ť
Always turn off and unplug the unit when cleaning or
servicing.
ť
DO NOT use the appliance if it is damaged.
ť
If service is needed contact an authorized service agent.
ť
Unplug the unit when stored or not in use.
ť
DO NOT pull or carry the appliance by the power cord.
ť
DO NOT pinch the wire in the door and DO NOT pull it along
edges or sharp corners.
ť
DO NOT run the power cord under carpeting and rugs.
ť
Use caution to prevent tripping on cord.
ť
DO NOT use the device in the following cases:
- Near a fire source
- In areas where gasoline, paint or other flammable
goods are stored
- In an area where the water can be projected
ť
DO NOT touch the plug or the device with wet hands.
ť
Basic safety precautions should always be followed when
using electrical appliances.
EN
SAFETY (CONTINUED)
This appliance has been manufactured for use in domestic
environments and should not be used for other purposes.
Only use the installation kit provided to install this unit.
DO NOT attempt to extend the exhaust hose or install
this unit using other methods other than that shown in
this manual. Improper installation will void any existing
warranties.
DO NOT use an extension cord with this unit.
This appliance can be used by children aged from 8 years
and above, and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Never insert your fingers or rods into the air outlet. Take
special care to warn children of these dangers.
The manufacturer is not liable for injury caused to
persons or property damage due to non-compliance
with maintenance instructions and improper use of the
appliance.
The appliance shall be installed in accordance with national
wiring regulations.
The appliance is not to be used by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction.
Children should be supervised to ensure that they do not
play with the appliance.
EN
THANK YOU
Congratulations on your purchase of this Honeywell Portable Air Conditioner.
Regarding the information pertaining to the installation, handling, servicing, cleaning and disposal
of the appliance, please refer to the below paragraph of the manual.
USER TIPS
Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are
housed in a compact unit. The air is dehumidified and cooled while a flexible exhaust hose sends
heat outside. The air conditioner includes a window venting kit.
No permanent installation is needed. The unit is easy to move from room to room and offers a truly
flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the exhaust
hose. There is no need to empty the drainage tank except in very humid conditions. Read and follow
the instructions carefully.
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air
conditioner or dehumidifier. If the product is being used with the fan function only, an open window
could improve air circulation.
Cooling and Dehumidifying OperationFan Operation
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize.
Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
Follow installation instructions to set up the unit.
ť
Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
ť
EN
1
PARTS DESCRIPTION
1
2
4
5
7
3
9
10
6
11
8
1) Control Panel
(Incl. Signal Receptor)
2) Air Outlet8) Power Supply Cord
3) Handle9) Remote Control
4) Casters10) Lower Rubber Drain Plug
5) Dust Filter11) Upper Rubber Drain Plug
6) Back Grill
7) Exhaust Hose Connector
(Air Conditioning Mode)
(Dehumidifier Mode)
EN
2
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this
Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries
regarding these installation procedures.
Install the exhaust hose with window bracket adapter and exhaust hose connector on both sides.
1.
Ensure proper fit on both ends.
2
x1x1
5
x1
=
2. The Window Brackets are approximatley 50 cm / 19.7 inches each, allowing you to install to
windows and balcony doors of different heights or width.
19.7"
50cm
1 part
50cm / 19.7" to
97cm / 38.2"
2 parts
Adjustable Knobs
3EN
1.2m / 47.2"
3 parts
INSTALLATION (CONTINUED)
Note: After setting the window bracket to the size of your window, please remove it from the window
and follow the instructions below.
3. Connect the exhaust hose to the exhaust hose connector on back of the unit. Slide-in the exhaust
hose connector. Press the button to lock the exhaust hose connector in place.
Exhaust Hose:
Dia. 5.5" (14cm)
Length: 12" to 47" (30cm to 120cm)
4. Connect the window bracket to the window bracket panel adapter. Ensure that all connections are
tight and installed properly.
5. Connect the window bracket to the window.
The Portable Air Conditioner is now ready to use.
6.
4EN
INSTALLATION (CONTINUED)
Important:
Do not replace or lengthen the exhaust hose as this could cause the unit to malfunction.
50 cm / 20"
MAX. 36 cm / 14"
MAX. 102 cm / 40"
NOT RECOMMENDEDRECOMMENDED
WARNING: Any warranties included with this product will be voided if an extra extension hose is
added to the originally provided installation kit or if the installation is performed differently than the
manufacturer's instructions, without proper consultation. Please contact Customer Support for help
with installation procedures if needed.
ť
The supplied exhaust hose has a diameter of 5.5 inches (14 cm) and can be extended from 12
inches to 47 inches (30 cm to 120 cm).
ť
Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and
cause the unit to malfunction or shut-off.
Make sure the back of the unit is at least 50 cm / 20 inches away from the wall. Do not place the
ť
unit in front of curtains or drapes as this could obstruct the airflow.
EN
5
USE & OPERATION
CONTROL PANEL
(6)(7)
(5)(1)
1) Timer Control4) Mode Control7) Timer Light
2) Fan Speed Control5) Power Control / Standby Mode8) Filter Alert
3) Timer / Temperature Set Controls6) Warning Light (when flashing)
FUNCTION BUTTONS
POWER CONTROL
The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicating it
is in a Standby Mode ready to be switched on anytime.
TIMER CONTROL
While the unit is turned on, press the timer button then press the + or - to select the number of hours
you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the button and the display will flash. While the display is flashing,
press the + or - button to select the number of hours you want the unit to turn OFF automatically.
(4)(2)(3)(8)
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the + or - button to select
the number of hours until you want the unit to automatically start running.
TEMPERATURE / TIMER SET CONTROLS
ť
Used for adjusting the timer and thermostat.
ť
The default display is setting temperature.
ť
In cooling mode, when + or - button is pressed, the set temperature is displayed and may be
adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only
adjustable in cool mode. The time is adjustable between 1 - 24 hours.
Note: By pressing both + or - buttons at the same time, the display will toggle between
Celsius(°C) and Fahrenheit(°F).
EN
6
USE & OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
WARNING LIGHT
Condensation may accumulate in the unit.
If the internal tank becomes full, the Power Control light will flash and the unit will not operate until
the unit has been drained (refer to Water Condensation Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
MODE CONTROL
Settings: Air Conditioning, Dehumidifying, Fan.
The corresponding indicator light will illuminate to indicate the current mode setting.
Air Conditioning Mode
ť
Adjust fan speed and air temperature to suit your desired comfort level.
Temperature setting range is 16°C - 32°C (60°F - 89°F).
ť
Dehumidifying Mode
Air is dehumidified as it passes through the unit, without being in full cooling mode.
If room temperature is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is
preset to LOW.
Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose.
Continuous drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).
Fan Mode
ť
For air circulation without air conditioner cooling.
FAN SPEED CONTROL
Applicable for model MO08 Series: High and Low.
Applicable for model MO10 Series: High, Medium, and Low.
FILTER ALERT
When the Filter Alert Light is ON, it is time to clean the filter. Switch the air conditioner OFF
and carefully remove the filter from the unit and clean. Replace the filter and switch ON the air
conditioner.
The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency
of filter cleaning depends on room environment conditions. Some rooms may require changing more
frequently than others.
EN
7
USE & OPERATION (CONTINUED)
REMOTE CONTROL
The functions work the same as the Portable Air Conditioner's Control Panel.
All key functions can be accessed from the remote control.
Power Control
ON / OFF
Fan Speed Control
Applicable for model MO08 Series:
ť)*()ť-08
Applicable for model MO10 Series:
ť)*()ť.*%ť-08
Timer Control
In running mode: Auto switch off
In stand-by mode: Auto switch on
Press ź or Ÿ button to adjust the
time setting for 1 hour intervals.
Temperature / Timer Set
Used for adjusting the timer and
ť
temperature.
When the ź orŸ key is pressed, the
ť
set temperature is displayed and
may be adjusted
Timer setting is available from 1 - 24 hours
ť
by pressing the key ź or Ÿ.
Mode Control
Press this button to change the operation
mode in the order of:
Air ConditioningDehumidifying
Fan
Note:
ť
Battery Installation: Remove the cover on the back of the remote control and insert two AAA
batteries with + and - pointing in the proper direction according to the polarity markings.
Caution:
ť
Use only two AAA or IEC R03 1.5V batteries.
ť
Remove the batteries if the remote control is not in use for a month or longer.
ť
All batteries should be replaced at the same time, do not mix with old batteries.
ť
Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
ť
Properly dispose of used batteries.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
8EN
CLEANING & MAINTENANCE
Appliance Maintenance:
Turn off the appliance before disconnecting the power supply.
1.
Only clean the appliance with a soft dry cloth.
2.
Dust Filter Maintenance:
The dust filter is to be cleaned every two weeks to maintain
air cooling efficiency. Please follow the below instructions
for cleaning the dust filters:
1.
Turn off the appliance and remove the upper and
lower dust filters.
Rinse it in lukewarm water. After cleaning, dry in
2.
a shaded and cool place, then reinstall.
End of Season Storage & Maintenance:
If the appliance will not be used for a long time, follow these steps:
1.
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a
shallow pan to collect the water (make sure to replace the drain plug when finished).
2.
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
3.
Turn off and unplug the air conditioner from the power supply.
4.
Remove the dust filter and clean with water. Dry the dust filter and then reinstall.
5.
Disconnecting the Window Installation Kit:
ť
Remove the Exhaust Hose from the unit by pressing the release button located on the right
side of the Hose and then sliding the Hose to the right side.
ť
Remove the Window Bracket, Window Bracket Panel Adapter and Exhaust Hose Connector.
ť
It is recommended to store the Window Kit parts in a bag together with the Remote Control
and placing them together with the air conditioner unit.
If needed, you can clean the Window Kit with a damp cloth and water before storing.
ť
Make sure all parts of the Window Kit are dry before storage.
6.
Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and
scratches collecting on the surface of the unit.
It is recommended to coil the power cord before storing to ensure the cord is protected from
7.
bents and creases.
Store the air conditioner in a cool, dry place, away from direct sunlight.
8.
Upper Dust Filter
Lower Dust Filter
EN
9
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and
shows a warning light (the Power Control button flashes with a red light). This warning light indicates
that the water condensation needs to be drained using the following procedures:
Manual Draining for AC & Dehumidifier Mode
Water may need to be drained in high humidity areas.
1.
Unplug the unit from power source.
2.
Place a shallow pan under the lower rubber drain plug.
See diagram.
3.
Remove the lower rubber drain plug.
4.
Water will drain out and collect in the shallow pan.
5.
After the water is drained, replace the lower rubber
drain plug firmly.
You can now turn on the unit.
6.
Continuous Draining for Dehumidifier Mode
While using the unit in dehumidifier mode, continuous
drainage is recommended.
Shallow Pan
(Not included)
Lower
Rubber
Drain Plug
1.
Unplug the unit from power source.
2.
Remove the upper/lower rubber drain plug.
Some residual water may spill so please have a pan to
collect the water. See diagram.
3.
Connect the drain connector to a ¾” hose or standard
garden hose (not included).
4.
The water can be continuously drained through the
drain tube into a floor drain or bucket.
Replace the drain plug.
5.
You can now turn on the unit.
6.
EN
10
Upper Rubber
Drain Plug
Drain Tube
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer support. Unplug and disconnect the appliance from the power source before attempting
to troubleshoot.
PROBLEMPOSSIBLE CAUSESOLUTION
No electricity.Check for power.
Batteries in the remote
The air
conditioning
unit does not
start
control need to be
replaced.
The power cord is not
properly plugged in.
Change remote control batteries.
Remove and reconnect the power cord.
Runs a short
while only
The safety LCDI plug has
tripped (USA / Canada /
Mexico only).
The thermostat
temperature setting
is too close to room
temperature.
Air outlet is blocked.Make sure the exhaust hose is properly connected.
There are tight bends in
the air exhaust hose.
Reset the safety LCDI plug, if problem persists
contact our customer support
(USA / Canada / Mexico only).
Lower the set temperature.
Connect exhaust hose as per instructions on page 4.