Honeywell MO08CESWS, MO08CESWK, MO08CESWB, MO10CESWS, MO10CESWK User manual

...
0 (0)

EN Portable Air Conditioner

User Manual

Read and save these instructions before use

FR Climatiseur portatif Mode d’emploi

Lire ces consignes avant l’utilisation de l’appareil et les conserver

ES Aire Acondicionado Portátil

Manual Del Propietario

Lea y guarde estas instrucciones antes de usar la unidad

Model / Modèle / Modelo:

MO08 Series / Série / Serie:

MO08CESWS, MO08CESWK, MO08CESWB

MO10 Series / Série / Serie:

MO10CESWS, MO10CESWK, MO10CESWB

Customer Support:

Assistance Au Client:

Servicio de atencion a clientes:

USA/ EE.UU: 1-800-474-2147

CANADA/ CANADÁ^ : 1-888-209-0999

^ Canada Customer Support service available for models sold in Canada only.

^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien. ^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.

www.jmatek.com

Email: usinfo@jmatek.com

SAFETY

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.

WARNING:

ťDO NOT operate the unit with a damaged plug or loose wall outlet. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

ťDO NOT cover the air intake and exhaust when in use.

ťDO NOT place objects on or sit on the unit.

ťAlways turn off and unplug the unit when cleaning or servicing.

ťDO NOT use the appliance if it is damaged.

ťIf service is needed contact an authorized service agent.

ťUnplug the unit when stored or not in use.

ťDO NOT pull or carry the appliance by the power cord.

ťDO NOT pinch the wire in the door and DO NOT pull it along edges or sharp corners.

ťDO NOT run the power cord under carpeting and rugs.

ťUse caution to prevent tripping on cord.

ťDO NOT use the device in the following cases:

-Near a fire source

-In areas where gasoline, paint or other flammable goods are stored

-In an area where the water can be projected

ťDO NOT touch the plug or the device with wet hands.

ťBasic safety precautions should always be followed when using electrical appliances.

EN

SAFETY (CONTINUED)

This appliance has been manufactured for use in domestic environments and should not be used for other purposes. Only use the installation kit provided to install this unit. DO NOT attempt to extend the exhaust hose or install

this unit using other methods other than that shown in this manual. Improper installation will void any existing warranties.

DO NOT use an extension cord with this unit.

This appliance can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Never insert your fingers or rods into the air outlet. Take special care to warn children of these dangers.

The manufacturer is not liable for injury caused to persons or property damage due to non-compliance with maintenance instructions and improper use of the appliance.

The appliance shall be installed in accordance with national wiring regulations.

The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children should be supervised to ensure that they do not play with the appliance.

EN

THANK YOU

Congratulations on your purchase of this Honeywell Portable Air Conditioner.

Regarding the information pertaining to the installation, handling, servicing, cleaning and disposal of the appliance, please refer to the below paragraph of the manual.

USER TIPS

Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is dehumidified and cooled while a flexible exhaust hose sends heat outside. The air conditioner includes a window venting kit.

No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air conditioning solution.

Auto Evaporation System - The unit automatically evaporates the condensate through the exhaust hose. There is no need to empty the drainage tank except in very humid conditions. Read and follow the instructions carefully.

To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.

Cooling and Dehumidifying Operation

Fan Operation

Important:

Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize. Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.

ťFollow installation instructions to set up the unit.

ťPlug the unit into a properly grounded circuit. DO NOT plug into an extension cord.

EN 1

Honeywell MO08CESWS, MO08CESWK, MO08CESWB, MO10CESWS, MO10CESWK User manual

PARTS DESCRIPTION

1

5

6

2

11

3 7

9

10

8

4

1)

Control Panel

7)

Exhaust Hose Connector

 

(Incl. Signal Receptor)

 

 

2)

Air Outlet

8)

Power Supply Cord

3)

Handle

9)

Remote Control

4)

Casters

10)

Lower Rubber Drain Plug

 

 

 

(Air Conditioning Mode)

5)

Dust Filter

11)

Upper Rubber Drain Plug

 

 

 

(Dehumidifier Mode)

6)

Back Grill

 

 

EN 2

INSTALLATION

It is important that the installation instructions below are followed for successful installation of this Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures.

 

1

2

 

3

 

 

 

x1

 

x1

x1

 

4

 

5

 

 

 

 

 

 

 

 

 

x1

 

 

x1

Installation Kit:

 

 

 

 

1.

Window Bracket Kit

(1 Set)

4.

Hole Cover

(1 Piece)

2.

Window Bracket Panel Adapter

(1 Piece)

5.

Exhaust Hose

(1 Piece)

3.

Exhaust Hose Connector

(1 Piece)

 

 

 

Installation Steps:

1.Install the exhaust hose with window bracket adapter and exhaust hose connector on both sides. Ensure proper fit on both ends.

=

2.The Window Brackets are approximatley 50 cm / 19.7 inches each, allowing you to install to windows and balcony doors of different heights or width.

19.7"

50cm 1 part

50cm / 19.7" to 97cm / 38.2" 2 parts

Adjustable Knobs

1.2m / 47.2"

3 parts

EN 3

INSTALLATION (CONTINUED)

Note: After setting the window bracket to the size of your window, please remove it from the window and follow the instructions below.

3.Connect the exhaust hose to the exhaust hose connector on back of the unit. Slide-in the exhaust hose connector. Press the button to lock the exhaust hose connector in place.

Exhaust Hose:

Dia. 5.5" (14cm)

Length: 12" to 47" (30cm to 120cm)

4.Connect the window bracket to the window bracket panel adapter. Ensure that all connections are tight and installed properly.

5. Connect the window bracket to the window.

6. The Portable Air Conditioner is now ready to use.

EN 4

INSTALLATION (CONTINUED)

Important:

Do not replace or lengthen the exhaust hose as this could cause the unit to malfunction.

 

50 cm / 20"

 

 

<![if ! IE]>

<![endif]>MAX. 102 cm / 40"

<![if ! IE]>

<![endif]>MAX. 36 cm / 14"

NOT RECOMMENDED

RECOMMENDED

 

WARNING: Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer's instructions, without proper consultation. Please contact Customer Support for help with installation procedures if needed.

ťThe supplied exhaust hose has a diameter of 5.5 inches (14 cm) and can be extended from 12 inches to 47 inches (30 cm to 120 cm).

ťDo not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off.

ťMake sure the back of the unit is at least 50 cm / 20 inches away from the wall. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.

EN 5

USE & OPERATION

CONTROL PANEL

(6)

(7)

(4)

(2)

(3)

(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5)

(1)

 

 

 

 

1)

Timer Control

 

4)

Mode Control

7)

Timer Light

2)

Fan Speed Control

 

5)

Power Control / Standby Mode

8)

Filter Alert

3)

Timer / Temperature Set Controls

6)

Warning Light (when flashing)

 

 

FUNCTION BUTTONS

POWER CONTROL

The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicating it is in a Standby Mode ready to be switched on anytime.

TIMER CONTROL

While the unit is turned on, press the timer button then press the + or - to select the number of hours you would like the unit to continue to run. The unit will turn off automatically.

AUTO TURN OFF:

While unit is running, press the button and the display will flash. While the display is flashing, press the + or - button to select the number of hours you want the unit to turn OFF automatically.

AUTO TURN ON:

When unit is in a standby mode (plugged in with power light on), then press the + or - button to select the number of hours until you want the unit to automatically start running.

TEMPERATURE / TIMER SET CONTROLS

ťUsed for adjusting the timer and thermostat.

ťThe default display is setting temperature.

ťIn cooling mode, when + or - button is pressed, the set temperature is displayed and may be adjusted. After 10 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. The time is adjustable between 1 - 24 hours.

Note: By pressing both + or - buttons at the same time, the display will toggle between Celsius(°C) and Fahrenheit(°F).

EN 6

USE & OPERATION (CONTINUED)

FUNCTION BUTTONS (CONTINUED)

WARNING LIGHT

Condensation may accumulate in the unit.

If the internal tank becomes full, the Power Control light will flash and the unit will not operate until the unit has been drained (refer to Water Condensation Drainage).

After switching the air conditioner off, you must wait 3 minutes before switching it back on again.

MODE CONTROL

Settings: Air Conditioning, Dehumidifying, Fan.

The corresponding indicator light will illuminate to indicate the current mode setting.

ťAir Conditioning Mode

Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 16°C - 32°C (60°F - 89°F).

ťDehumidifying Mode

Air is dehumidified as it passes through the unit, without being in full cooling mode.

If room temperature is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW.

Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose. Continuous drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).

ťFan Mode

For air circulation without air conditioner cooling.

FAN SPEED CONTROL

Applicable for model MO08 Series: High and Low.

Applicable for model MO10 Series: High, Medium, and Low.

FILTER ALERT

When the Filter Alert Light is ON, it is time to clean the filter. Switch the air conditioner OFF and carefully remove the filter from the unit and clean. Replace the filter and switch ON the air conditioner.

The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency of filter cleaning depends on room environment conditions. Some rooms may require changing more frequently than others.

EN 7

USE & OPERATION (CONTINUED)

REMOTE CONTROL

The functions work the same as the Portable Air Conditioner's Control Panel. All key functions can be accessed from the remote control.

Power Control

ON / OFF

Fan Speed Control

Applicable for model MO08 Series:

ť )*() ť -08

Applicable for model MO10 Series:

ť )*() ť .*% ť -08

Timer Control

In running mode: Auto switch off In stand-by mode: Auto switch on Press ź or Ÿ button to adjust the time setting for 1 hour intervals.

Note:

Temperature / Timer Set

ťUsed for adjusting the timer and temperature.

ťWhen the ź or Ÿ key is pressed, the set temperature is displayed and may be adjusted

ťTimer setting is available from 1 - 24 hours by pressing the key ź or Ÿ.

Mode Control

Press this button to change the operation mode in the order of:

Air ConditioningDehumidifying

Fan

ťBattery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and - pointing in the proper direction according to the polarity markings.

Caution:

ťUse only two AAA or IEC R03 1.5V batteries.

ťRemove the batteries if the remote control is not in use for a month or longer.

ťAll batteries should be replaced at the same time, do not mix with old batteries.

ťDo not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.

ťProperly dispose of used batteries.

This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

ť 3FPSJFOU PS SFMPDBUF UIF SFDFJWJOH BOUFOOB ť *ODSFBTF UIF TFQBSBUJPO CFUXFFO UIF FRVJQNFOU BOE UIF SFDFJWFS ť $POOFDU UIF FRVJQNFOU JOGP BO PVUMFU PO B DJSDVJU EJGGFSFOU GSPN UIBU UP XIJDI UIF SFDFJWFS JT DPOOFDUFE ť $POTVMU UIF EFBMFS PS BO FYQFSJFODFE SBEJP 57 UFDIOJDJBO GPS IFMQ

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

EN 8

CLEANING & MAINTENANCE

Appliance Maintenance:

1.Turn off the appliance before disconnecting the power supply.

2.Only clean the appliance with a soft dry cloth.

Dust Filter Maintenance:

Upper Dust Filter

 

The dust filter is to be cleaned every two weeks to maintain air cooling efficiency. Please follow the below instructions for cleaning the dust filters:

1.Turn off the appliance and remove the upper and

lower dust filters.

2.Rinse it in lukewarm water. After cleaning, dry in

a shaded and cool place, then reinstall.

Lower Dust Filter

End of Season Storage & Maintenance:

If the appliance will not be used for a long time, follow these steps:

1.Be sure to drain the left-over water condensation. Remove the lower drain plug and use a shallow pan to collect the water (make sure to replace the drain plug when finished).

2.To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.

3.Turn off and unplug the air conditioner from the power supply.

4.Remove the dust filter and clean with water. Dry the dust filter and then reinstall.

5.Disconnecting the Window Installation Kit:

ťRemove the Exhaust Hose from the unit by pressing the release button located on the right side of the Hose and then sliding the Hose to the right side.

ťRemove the Window Bracket, Window Bracket Panel Adapter and Exhaust Hose Connector.

ťIt is recommended to store the Window Kit parts in a bag together with the Remote Control and placing them together with the air conditioner unit.

ťIf needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage.

6.Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit.

7.It is recommended to coil the power cord before storing to ensure the cord is protected from bents and creases.

8.Store the air conditioner in a cool, dry place, away from direct sunlight.

EN 9

WATER CONDENSATION DRAINAGE

When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the Power Control button flashes with a red light). This warning light indicates that the water condensation needs to be drained using the following procedures:

Manual Draining for AC & Dehumidifier Mode

Water may need to be drained in high humidity areas.

1.Unplug the unit from power source.

2.Place a shallow pan under the lower rubber drain plug. See diagram.

3.Remove the lower rubber drain plug.

4.Water will drain out and collect in the shallow pan.

5.After the water is drained, replace the lower rubber drain plug firmly.

6.You can now turn on the unit.

Continuous Draining for Dehumidifier Mode

While using the unit in dehumidifier mode, continuous drainage is recommended.

1.Unplug the unit from power source.

2.Remove the upper/lower rubber drain plug.

Some residual water may spill so please have a pan to collect the water. See diagram.

3.Connect the drain connector to a ¾” hose or standard garden hose (not included).

4.The water can be continuously drained through the drain tube into a floor drain or bucket.

5.Replace the drain plug.

6.You can now turn on the unit.

Shallow Pan (Not included)

Lower

Rubber

Drain Plug

Upper Rubber

Drain Plug

Drain Tube

EN 10

TROUBLESHOOTING GUIDE

The following troubleshooting guide addresses the most common problems. If problems persist, call customer support. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

 

No electricity.

Check for power.

 

 

 

 

Batteries in the remote

 

 

control need to be

Change remote control batteries.

The air

replaced.

 

 

 

conditioning

 

 

unit does not

 

 

start

 

 

 

The power cord is not

Remove and reconnect the power cord.

 

properly plugged in.

 

 

 

 

 

 

The safety LCDI plug has

Reset the safety LCDI plug, if problem persists

 

tripped (USA / Canada /

contact our customer support

 

Mexico only).

(USA / Canada / Mexico only).

 

 

 

 

The thermostat

 

 

temperature setting

Lower the set temperature.

 

is too close to room

 

 

 

temperature.

 

Runs a short

 

 

Air outlet is blocked.

Make sure the exhaust hose is properly connected.

while only

 

 

 

 

 

 

There are tight bends in

Connect exhaust hose as per instructions on page 4.

 

the air exhaust hose.

 

 

 

 

 

EN 11

Loading...
+ 32 hidden pages