L8124A,B,C,E,G,L,M AQUASTAT® RELAYS
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed
specifications. Also, this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be
expected if those conditions are changed.
TRADELINE® Models
TRADELINE models are selected and packaged for ease of
handling, ease of stocking, and maximum replacement value.
TRADELINE model specifications are the same as those of
standard models except as noted in Table 1.
Tradeline Models Available L8124B,E,G,L Aquastat Relays
without well and spud.
Additional Features:
• Heat-conductive compound for better bulb response in
oversized well.
• Case can be vertically or horizontally mounted.
• Field-addable limit stops.
• TRADELINE pack with cross reference label and special
instructions.
Pressure Rating:
200 psi (1380 kPa) on outside of immersion well.
100 psi (690 kPa) on capsule if inserted directly.
Maximum Ambient Temperature:
Case: 150°F (66°C).
Sensing element: 265°F (129°C).
Thermostat Heat Anticipator Setting: 0.2A.
Low Limit:
Setting: 110°F to 220°F, adjustable (43°C to 104°C).
Differential: 10°F to 25°F, adjustable (6°C to 14°C).
High Limit:
Setting: 130°F to 240°F, adjustable (54°C to 116°C).
Differential: 10°F, fixed (6°C).
Mounting Means: 1/2 or 3/4 in. taper pipe threaded.
Dimensions: See Fig. 1 and 2.
Sensing Element: 3/8 x 2-7/8 in (10 x 73 mm).
Insulation Depth: 1-1/2 or 3 in. (38 or 76 mm);
see Fig. 1 and 2.
Insertion Length: 3-3/8 in. (86 mm).
Approvals:
Underwriters Laboratories Inc.:
Listed (L8124 models with well): File No. MP466,
Guide No. MBPR.
Component Recognized (L8124 Models Without Well):
File No. MP466, Guide No. MBPR2.
Canadian Standards Association:
Component Recognized: File No. LR1620,
Guide No. 400-E-O.
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Relations
Honeywell, 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
60-2061—102
L8124A,B,C,E,G,L,M AQUASTAT® RELAYS
Table 1. Aquastat Relay models.
Electrical
Ratings
Burner
Circuit
Model
Number
Burner
Control
Circuit
Case Dimensions
HeightWidthDepth
in.mmin.mmin.mm
Can be
Used For
Multizone
With
Circulators
No. of V8043
Zone Valves
Powered
Without
Additional
a
Transformer
L8124A 120V6-1/81564-3/8 1113-1/16 78Yes—Same as
L8124A-G,L
circulator
rating
L8124B
b
6-1/81564-3/8 1113-1/16 78——0.25A at 1/4
to 12 Vdc
L8124C 120V4-3/81116-1/8 1563-1/16 78Yes—Same as
L8124A-G,L
circulator
rating
L8124E 24V6-1/81564-3/8 1113-1/16 78Yes21.25A at 24
Vac ; 3 0 VA
(total load)
B1-B2 TV-Z
L8124G 120V6-1/81564-3/8 1113-1/16 78—2Same as
L8124A-G,L
circulator
rating
L8124L120V4-3/81116-1/8 1563-1/16 78Yes2Same as
L8124A-6,L
circulator
rating
L8124M 120V4-3/81116-1/8 1563-1/16 78Yes—Same as
L8124A
a
Multizone control can be provided by using a separate circulator and R845 Relay for each zone.
b
Contacts are not powered; they are rated for switching of millivoltage loads.
Circulat
or
Circuit
120 Vac:
7.4A (full
load);
44.4A
(locked
rotor)
240
Vac:3.7A
(full
load);
22.2A
(locked
rotor)
Mounting
Vertical
Vertical or
horizontal
Horizontal
Vertical or
horizontal
Horizontal
Replacement Aquastat Assemblies:
See Table 2 and Fig. 3 through 7.
Table 2. Replacement Aquastat assemblies.
Celsius (L8124A,
Model
L8124A-C,
Fahrenheit
1-1/2 in. or 3 in. (38
or 76 mm) insulation
125026AAE125026BAC
100/220V Model Only)
1-1/2 in. or 3 in. (38
or 76 mm) insulation
E,G,L,M
360-2061—10
L8124A,B,C,E,G,L,M AQUASTAT® RELAYS
6
(
2-1/8 (54)
5
T
T
(VERTICAL
MOUNT)
4-5/16 (110)
-1/8
156)
3-1/8
(79)
1/8 (3)
1-1/4 (32) (HORIZONTAL
MOUNT—BOTTOM)
KNOCKOUTS FOR
1/2 (13) CONDUIT
3-3/8
(86)
1-1/4 (32)
(VERTICAL
MOUNT)
3-1/16 (78)
(HORIZONTAL
MOUNT)
Fig. 1. L8124 mounting dimensions in in. (mm).
CONTROL
MOUNT
FITS BOILER TAPPED HOLE
1/2 OR 3/4 IN. NPT
M892
VOLTAGE
BARRIER
TRANSFORMER
FOR THERMOSTA
CIRCUIT
DIFFERENTIAL
SETTING
CIRCULATOR
RELAY
LOW LIMIT
SETTING
HIGH LIMIT
SETTING
Fig. 3. Internal view of L8124A and C.
TRANSFORMER
FOR THERMOSTA
CIRCUIT
M8961
DIFFERENTIAL
SETTING
INSULATION
LENGTH 1-1/2
OR 3 IN.
(38 OR 76 MM)
INSERTION
LENGTH
3-3/8 IN.
(86 MM)
M1797
CIRCULATOR
RELAY
LOW LIMIT
SETTING
Fig. 2. Immersion well dimensions. (Refer
to form 68-0040, Wells and Fittings for
Temperature Controllers, to order well.)
Fig. 4. Internal view of L8124B.
HIGH LIMIT
SETTING
GROUND SCREW
M8964
60-2061—104
TRANSFORMER
T
T
T
FOR THERMOSTA
CIRCUIT
DIFFERENTIAL
SETTING
CIRCULATOR
RELAY
LOW LIMIT
SETTING
HIGH LIMIT
SETTING
L8124A,B,C,E,G,L,M AQUASTAT® RELAYS
GROUND SCREW
VOLTAGE
BARRIER
TRANSFORMER
FOR THERMOSTA
CIRCUIT
DIFFERENTIAL
SETTING
CIRCULATOR
RELAY
Fig. 5. Internal view of L8124E.
GROUND
HIGH LIMIT
SETTING
SCREW
Fig. 6. Internal view of L8124G and L.
GROUND SCREW
M8962
TRANSFORMER
FOR THERMOSTA
CIRCUIT
DIFFERENTIAL
SETTING
CIRCULATOR
RELAY
LOW LIMIT
SETTING
M8853
LOW LIMIT
SETTING
HIGH LIMIT
SETTING
Fig. 7. Internal view of L8124M.
INSTALLATION
When Installing This Product…
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a
hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death or property
damage.
Product is for use only in a system with a pressure
relief valve.
M8963
WARNING
560-2061—10
Electrical Shock Hazard.
Can cause severe injury, death or property
damage.
Disconnect power supply before beginning installation
to prevent electrical shock or equipment damage.