Honeywell IS2535TC Installation Instructions Manual

Select the mounting location.
Separate the sensor housings and remove the printed cir­cuit board (PCB).
IntelliSense
®
IS2535TC Passive Infrared Motion Sensor Installation Instructions
Mounting Location Guidelines
2.3 m - 2.7 m (7.5' - 9')* mounting height.
Aim sensor away from windows or heating/cooling devices.
Sensor must have a clear line-of-sight to protected area.
If using in a pet application, remove the High Security lens
and replace with the Pet Immune Lens (see Step 5).
*See Special Instructions for pet applications.
Use a small screwdriver to remove the cover screw (if installed), then push in the housing latch at the bottom of the sensor, and gently pull apart the housings.
Push outward on the PCB latch and lif t the PCB out of the housing.
Aim away from:
Mount the unit.
Slide the wire through the wire knockouts in the back housing, attach the wire with a wire tie, and cut off the excess wire tie.
Mount the back housing flat against a wall or in a corner using #6 screws supplied. [Notes: If using the wall tamper, refer to the Tamper Switches section. If using a mounting bracket see the Accessories section, and follow the installation instructions supplied with the bracket.]
Replace the PCB.
Seal any openings with RTV compound.
Wire the sensor. Connect wires to terminal as shown using wire size 0.8
- 1.5 mm (22-16 AWG). Observe the proper polarity.
Configure the sensitivity and walk-test the sensor.
Set the sensitivity appropriate for the application (see options below), replace the front cover, and apply power to the sensor. Begin walk-test after the LED stops flashing (see the LED Operation section). Walk through the detection zones, observing the sensor’s LED whenever motion is detected. The red LED shows actual alarm relay operation. The absolute range of all PIR units is subject to variation because of different types of clothing, backgrounds, and ambient temperature. For this reason, ensure that the most likely intruder routes are well within the PIR’s detection zones and that walk-testing is carried out along those routes.
Wall Mount Knockouts
Install the look-down mask (black ring
supplied), if desired, to reduce the look-
down sensitivity for pet applications.
Wire Knockouts
Corner Mount Knockouts
#6
pan-head
screws
Select the appropriate lens* for the installation. If necessary, mask segments as required. (Refer to the Masking the Lens section.)
To change the lens:
Pull up on the bug guard latches with two fingers and remove the bug guard with the other hand.
Pull outward on the lens flange (single-slotted) of the existing lens and remove the lens.
Align the double-slotted lens flange to the bug guard, SMOOTH side facing outward, and snap the single-slotted lens flange in place.
Place the bug guard into the look-down window and press it into place.
Note: For High Security applications, use the High Security Lens, disable the LED (S3=OFF), and set the sensitivity to High (S1 and S2=ON).
Strain Relief Options
Terminal
Block
The PCB alignment
guide should
always point down,
as shown.
LED
Set the DIP switches.
DIP
Switch
Pulse Count 2
Low Sensitivity
LED Disabled
Active Low
SWITCH OFF ON
1 (PC)
2 (SENS)
3 (LED)
4 (POL)
Pulse Count 1
High Sensitivity
LED Enabled
Active High
(Notes: Default switch settings are shown in grey.
See the Specifications section for more information on the
Test/Arm inputs. *Test = Remote LED Enable.)
ALARM
30 mA, 24 VDC
POWER
21 mA, 12 VDC*,
25 mA max
TAMPER
30 mA, 24 VDC
Normally Closed Loop, No EOL Resistor
Polarity Test* Input Arm Input
(L) = Test*; (H) = Normal
(L) = Arm; (H) = Disarm
(H) = Test*; (L) = Normal
(H) = Arm; (L) = Disarm
Tamper Knockout
ALARM
30 mA, 24 VDC
POWER
21 mA, 12 VDC*,
25 mA max
TAMPER
30 mA, 24 VDC
Normally Open Loop, No EOL Resistor
ALARM
30 mA, 24 VDC
POWER
21 mA, 12 VDC*,
25 mA max
TAMPER
30 mA, 24 VDC
Normally Closed Loop, w/ EOL Resistors
ALARM
30 mA, 24 VDC
POWER
21 mA, 12 VDC*,
25 mA max
TAMPER
30 mA, 24 VDC
Normally Open Loop, w/ EOL Resistors
Test/Arm
0 VDC - V
supply
,
1.8 mA max
Test/Arm
0 VDC - V
supply
,
1.8 mA max
Test/Arm
0 VDC - V
supply
,
1.8 mA max
Test/Arm
0 VDC - V
supply
,
1.8 mA max
End of Line
(EOL) Screws
*Lens options: Pet Immune or High Security/Non-Pet Immune [factory default] lens.
Note: EOL = Single End-of-Line supervised resistor.
*For UL voltage, see Specifications Section.
IntelliSense
®
IS2535TC Passive Infrared Motion Sensor Product Information
MOUNTING LOCATION GUIDELINES
The IS2535TC is designed for use indoors. The sensor can be corner, wall, or bracket mounted (see Accessories section). Make sure that the sensor has a clear line-of-sight to the protected area: infrared light cannot penetrate solid ob­jects, and the sensor must “see” an area in order to detect a moving person. The sensor should be pointed into the room interior, and away from windows and heating/cooling sources. Additionally, the sensor should be installed on a surface where the temperature is similar to that of the area being protected and not pointed at direct or reflected sunlight.
DETECTION PATTERNS
Top View
Wide Angle High Security/Non-Pet Immune Lens (installed) and Wide Angle Pet Immune Lens (included)
OPTIONAL LENS DETECTION PATTERN
SPECIFICATIONS
Range:
11 m x 12 m (35’ x 40’)
Pet/Animal Immunity:
80 lb, 40 lb and 0 lb (36.3 kg, 18.1 kg, 0 kg) Mounting Height (center of lens):
2.3 m - 2.7 m (7.5’ - 9’) [Note: 2.3 m (7.5’) is the optimum mounting height.]
Power requirements:
8.5 - 15.4 VDC (UL: 10 - 14 VDC); 21 mA nominal at 12 VDC, 25 mA max; AC Ripple: 50 to 120 Hz, 3 V peak-to-peak at nominal 12 VDC
Alarm relay:
Form C 30 mA, 24 VDC; 40 Ohms resistance max
Tamper switches:
Cover and Wall Form A (normally closed with cover installed) 30 mA, 24 VDC
RFI immunity:
30 V/m, 10 MHz-1000 MHz
PIR white light immunity:
6,500 Lux (min.)
Sensitivity:
Switch selectable (Lowest, Low, Medium and High)
Operating temperature:
-10
o
C to 55o C (14o F to 131o F)
Relative Humidity:
5% to 95%; non-condensing
Temperature Compensation:
Advanced dual slope
PIR fields-of-view:
Dual element
Pet Immune Lens:
44 long range 36 intermediate 18 lower 4 look-down
High Security/Non-Pet Immune Lens:
22 long range 12 intermediate 6 lower 4 look-down
Dimensions:
11.2 cm x 6.0 cm x 4.0 cm 4-3/8" x 2-1/4” x 1-1/2”
Weight:
94 g (3.32 oz) Packaged Product: 134 g (4.73 oz)
Control Signal Levels & Current (Test / Arm inputs):
(L) = 0.0 VDC to 1.5 VDC; -0.6 mA max (H) = 3.5 VDC to V
supply
; 1 mA typical at
12 VDC, 1.8 mA max
Accessories Included:
Mounting hardware Look-down mask Pet Immune Lens Mask Label (P/N K9854) High Security/Non-Pet Immune Lens Mask
Label (P/N K9855)
Pet Immune Lens (P/N 5-532-719)
Accessories Available:
SMB-10 Swivel Mount Bracket
(P/N 0-000-110-01)
SMB-10C Swivel Mount Ceiling
Bracket (P/N 0-000-111-01)
SMB-10T Swivel Mount Bracket w/
Tamper (P/N 0-000-155-01) Note: The High Security/Non-Pet Immune Lens and Swivel Mount Brackets should not be used in pet applications.
EN 50131-1 Compliant Accessories:
SMB-10T Swivel Mount Bracket w/
Tamper (P/N 0-000-155-01)
Approvals/listings:
FCC part 15, Class B verified IC, ICES-003, Class B verified CE C-Tick cULus listed SIA PIR-01 Passive Infrared detector standard features for false alarm immunity Enclosure rating: IP30 IK04 EN 50131-1 and TS 50131-2-2 Security Grade 2; Environmental Class II
Note: In TS 50131-2-2 compliant installations: mount the sensor at 2.3 m, select the high sensitivity setting, and install a cover screw (included).
Suitable for connection to an EN 60950 Class II Limited Power Source in European installations.
Customers in European Union countries are advised to dispose
of this product, at the end of its useful life, as per applicable local laws, regulations and procedures.
IMPORTANT: The IS2535TC should be tested at least once each year. For proper wiring methods, refer to the National Electrical Code NFPA 70.
© 2005 Honeywell International Inc. • Honeywell and IntelliSense are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. P/N 5-051-685-00 Rev A
LED OPERATION
To Enable the alarm LED, turn switch S3 ON. To Disable the alarm LED, turn switch S3 OFF. The LED will
temporarily remain enabled for 10 to 12 minutes. This feature gives the installer time to walk-test the unit as explained below.
Automatic Walk-Test Mode with alarm LED disabled (switch S3 OFF):
After applying power to the sensor, it will warm up for up to three minutes, and then the LED will temporarily remain enabled for a 10 minute walk-test period. After 10 minutes, the LED will automatically switch to disabled.
To restart the 10 minute walk-test mode, switch S3 ON, and then OFF again.
Side View
Pet Immune Lens (included)
* Look-down fingers are fully enabled only when the look-down mask is removed (see Step 6). [Note: Enabling the look-down fingers is not recommended in pet immune installations.]
Side View
High Security/Non-Pet Immune Lens (installed)
Note: The distances in the illustrations do not represent maximum detection distances. A walk­test is required after mounting to ensure proper detection.
MASKING THE LENS
If the installation requires some segments of the detection pattern to be blocked off, you can mask part of the lens pattern with the lens masking label material (included).
To mask segments of the detection pattern:
Open the sensor housing and remove the lens (see Step 5).
Select the appropriate segments to be masked, and place the lens mask label
over the inside of the lens.
LED
Enabled
LED
Disabled
OPERATION
Enabled
Warm Up
(up to 3 minutes)
Normal
Alarm
Trouble
Disabled
Conditions
Alarm LED Alarm Relay
(Normally Closed Loop)
Closed
Closed Opened
for 3 seconds
See
Troubleshooting
FCC NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that changes or modifications not expressly approved by Honeywell could void the user’s authority to operate this equipment. NOTE: This equipment as been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna; 2) increase the separation between the equipment and receiver; 3) connect the equipment into an outlet on a circuit different from that to which the receiver is connected; 4) consult the dealer or an experi­enced radio/television technician for help. IC Notice: This Class B digital apparatus complies with the Canadian ICES-003. Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.
TROUBLESHOOTING
Symptom: Sensor is not operating.
Corrective Action: Check to make sure the Power terminals are wired correctly. If the
power terminals are wired correctly, and the sensor does not operate when power is applied, replace the sensor.
Symptom: Fast Blinking LED -- Trouble condition; two possible causes.
1. Temperature Compensation failure: The sensor checks Temperature once every
100 ms. When a Temperature Compensation failure occurs, the sensor defaults to room temperature sensitivity and continues to operate normally while signalling trouble. The trouble is stored in memory, and when the next valid alarm condition is detected, the alarm relay latches open (NC loop).
2. PIR self-test failure: In the absence of PIR signals, the sensor internally checks its PIR
circuit once every ten minutes. If six consecutive self-tests fail, the sensor signals trouble with its LED, and the relay latches closed (NC loop). Subsequent detection of a valid PIR Signal will clear the trouble, and the relay will return to normal operation.
Corrective Action: Replace the sensor.
Slow Blink
OFF ON for 3 seconds
Fast Blink
Slow Blink
OFF *See LED Operation Fast Blink
Use Lens Mask K9855 to mask Long, Intermediate and Lower Range segments
on the High Security/Non-Pet Immune Lens (P/N 5-532-477, installed).
TAMPER SWITCHES
The IS2535TC is equipped with normally-closed (NC) cover tamper. Each sensor is shipped with the cover tamper operational.
A wall tamper switch is also provided. To use the wall tamper switch, remove the PCB, and the Tamper Knockout located toward the bottom of the back cover (see Step 3 on page 1). Before mounting the sensor, install a tamper screw in the wall so it protrudes 6.35 mm (1/4”) above the mounting surface. Replace the PCB and mount the sensor on the wall, over the tamper screw. The tamper screw will depress the back tamper lever as shown.
The cover and wall tamper switches are in series, so if either switch opens, a tamper will be signalled at the terminal block on the PCB.
SPECIAL INSTRUCTIONS FOR INSTALLATION WITH PETS
To take full advantage of the pet immunity in the IS2535TC, follow the guidelines below:
Mount the center of the sensor lens at 2.3 m (7.5 feet) high.
Install the Pet Immune Lens (P/N 5-532-719). [Refer to Step 5 to change the lens.]
Set the sensor to the Low or Lowest sensitivity setting (see Step 7, on page 1), as
required by the application.
In Lowest sensitivity setting, total combined weight of animals may not exceed 36
kg (80 lb).
In Low sensitivity setting, total combined weight of animals may not exceed 18 kg
(40 lb).
The Look-down mask must be installed (see Step 6).
Mount where pets cannot come within 1.8 m (6 feet) of the sensor by climbing on
furniture, boxes or other objects.
Do not aim the sensor at stairways or furniture/objects that can be climbed on by
animals.
Environmental differences and the amount of heat radiated by an animal will
vary the animal immunity levels exhibited by the sensor. Each installation
should be tested to determine the exact level of attainable animal immunity.
Note: Pet immunity characteristics for this sensor have not been verified by Underwriter’s
Laboratories, Inc.
CONTROL INPUTS
There are two inputs, TEST and ARM, allowing some of the sensor functions to be controlled remotely. Each input is internally pulled up to +5V through a 10KOhm resistor.
The POL switch (switch 4) can reverse the logic sense of both the input control signals.
To select the approriate POL (switch 4) setting, refer to the table in step 6, on page 1.
TEST input
The Test input allows the LED to be remotely enabled. To use this feature, the LED DIP switch (switch 3) must be OFF, allowing the LED to operate based on the voltage level connected to the Test Input. Like the LED DIP switch, however, the Test Input will not enable the LED if the sensor is armed (see the Arm Input section).
ARM Input / Alarm Memory
When armed, the sensor’s LED is disabled. If an alarm occurs while armed, an alarm is triggered, and the sensor stores the event in memory. When next disarmed, the Alarm Memory turns the LED On. To clear the alarm event from memory, the sensor should be re-armed briefly (0.5 to 2 seconds) and then disarmed.
Note: When inputs are not used, the POL switch should be OFF.
Alarm Relay
(Normally Opened Loop)
Opened
Opened Closed
for 3 seconds
See
Troubleshooting
Switch 3 Test Input LED
Operation
OFF OFF ON ON
Active
Inactive
Active
Inactive
Enabled Disabled Enabled Enabled
Use Lens Mask K9854 to mask Long, Intermediate and Lower Range segments
on the Pet Immune Lens (P/N 5-532-719, included).