FEATURES
•Direct control of mixing valve actuators for individual room temperature control
•The HM80 is communicating with the Chronotherm CM67RFMV, (CM67z) to keep the room temperature constant, time program, holiday function
•Manual or automatic control
•Reduce installation time and costs
•Pump control, after running time adjustable 0..99 min.
•External Flow Sensor connectable NTC 20KΩ, 25°C not linear (type T7414C1012)
•Maintenance run for pump and mixing valve
•Boiler feedback heat on demand with CM67RFMV,CM67z
•Heating / Cooling operation
•RF communication check
HMC 80/82
PRE-CONFIGURED KITS
PRODUCT DATA
GENERAL
The wireless Universal Mixing valve Controller is used for heating/cooling zoning control. The HM80 controls the mixing valve depending on the room temperature and room setpoint by using fuzzy control logic to keep the room temperature precisely constant. It can be done with and without the flow sensor T7414C1012 (optional)
The pump can be controlled directly with the HM80 relay output 230V~.
SPECIFICATIONS
ELECTRICAL
Electrical voltage supply |
: 230V ~ , 50Hz , max. 6A |
Pump relay |
: 3A, cos φ 0,7, without potential |
|
free relay contact |
Mixing valve relay |
: 3A, cos φ 0,7, without potential |
|
free relay contact |
RF Communication
Frequency |
: 868,3 MHz Receiver |
Receiver class |
: 2 |
RF communication range : 30m in a residential building
|
environment |
RF communication |
: short, high rate transmission to |
Technology |
minimize air time and avoid |
|
collisions |
ENVIRONMENTAL and STANDARDS
Storage temperature |
: -20 … +70 ºC |
Operating temperature |
: 0 … +50 ºC |
Dimensions (HxWxD) |
: 161,5 x121x 46 mm |
Humidity |
: max. 5 … 90 % |
Material |
: Socket: PA-GF 25-FR |
|
Cover : PC-FR VO certificated |
IP class |
: IP54 |
Options |
: Flow sensor NTC 20KΩ |
|
connectable |
Compatible products |
: CM67RFMV, CM67z |
Approval |
: CE |
EN0H0503GE51 R0905
HMC 80/82
KIT CONFIGURATION
Kit |
|
Components |
Pre-Configured |
HMC80 |
1x Universal Mixing Valve Controller HM80 |
Yes |
|
|
1x Chronotherm CM67RFMV |
|
|
|
4x |
Eurofix (strain relief) |
|
HMC82 |
1x Universal Mixing Valve Controller HM80 |
Yes |
|
|
1x Chronotherm CM67RFMV |
|
|
|
1x |
Flow sensor T7414C1012 |
|
|
4x |
Eurofix (strain relief) |
|
APPLICATION EXAMPLES
Mixing Valve Application for UFH without boiler feedback
CM67RFMV with parameter |
CM67RFMV |
Flow temperature sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|||
|
|
|
|
|
|
|||
|
|
|
|
|
|
|||
T7414C1012 (optional) |
|
|
|
|
|
|
||
|
|
|
|
|
|
|||
settings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pump after running time 0…99 min Actuator running time 0…240 s
Min flow temperature setpoint 0…50°C Max flow temperature setpoint 0…99°C
HM80
Pump
M
Mixing Valve
The HM80 controls the mixing valve depending on the room temperature setpoint and communicates with the CM67RFMV. In addition the controller has a relay output for pump control and connection for the flow sensor.
Without using the flow sensor the mixing valve position is adjusted in accordance with the room setpoint temperature and the actual room temperature.
If the flow sensor is used the mixing valve position is adjusted in accordance with the calculated flow temperature setpoint and the measured flow temperature. The flow temperature setpoint is calculated from the room temperature setpoint and the actual room temperature deviation.