Honeywell HD28W4HR6, HD28D4HR9X, HD28D4HR6X, HD28D4HR9, HD28C4HR9X User Manual

...
Premium Vandal
Dome Camera
NTSC / PAL
HD28C4HR6 HD28C4HR6X HD28C4HR9 HD28C4HR9X HD28W4HR6 HD28W4HR6X HD28W4HR9 HD28W4HR9X HD28D4HR6 HD28D4HR6X HD28D4HR9 HD28D4HR9X
Installation Guide
Document 900.0275 – 10/05 – Rev 1.01
Issue Date Revisions
1.00 09/05 New document.
1.01 10/05 Changed HD28R to HD28 throughout, removed utp & fiber termination boards updated back cover.
Rev 1.01 ii Document 900.0275
10/05
Warnings
Installation and servicing should be performed only by qualified and experienced technicians to conform to all local codes and to maintain your warranty.
WARNING! The use of CSA Certified/UL Listed Class 2 power adapters
is required to ensure compliance with electrical safety standards.
WEEE (Waste Electrical and Electronic Equipment). Correct disposal
of this product (applicable in the European Union and other European countries with separate collection systems). This product should be disposed of, at the end of its useful life, as per applicable local laws, regulations, and procedures.
Explanation of Graphical Symbols
CAUTION
RISK OF ELECTRIC
SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE THE COVER.
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL
Rev 1.01 iii Document 900.0275
THIS SYMBOL INDICATES THAT DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THE UNIT.
THIS SYMBOL INDICATES THAT IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS ACCOMPANY THIS UNIT.
10/05
FCC Compliance Statement
Information to the User: This equipment has been tested and found to comply
with the limits for a Class A digital device. Pursuant to Part 15 of the FCC Rules, these limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Caution Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à norme NMB-003 du
Canada.
Manufacturer’s Declaration of Conformance
The manufacturer declares that the equipment supplied with this guide is compliant with the essential protection requirements of the EMC directive 89/336/ EEC and the Low Voltage Directive LVD 73/23 EEC, conforming to the requirements of standards EN 55022 for emissions.
Rev 1.01 iv Document 900.0275
10/05

Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Unpack Everything . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Mounting the Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Preparing the Mounting Surface. . . . . . . . . . . . . . . . . . . . . . . . . 2
Installing the Conduit Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Wiring Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Connecting the Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Adjusting the Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Dip Switch Functions (Color Cameras, Including TDN Models) .6
Adjustment Method (Color Cameras) . . . . . . . . . . . . . . . . . . . . .7
White Balance Adjustment Method (Color Cameras) . . . . . . . . .7
Manually Setting Shutter Speed (Color Cameras) . . . . . . . . . . .8
Dip switch functions (WDR cameras) . . . . . . . . . . . . . . . . . . . . . 9
Adjustment method (Wide Dynamic Range Cameras) . . . . . . . .9
Adjusting the Line Lock (Vertical Phase) for 24 VAC Operation 10
Adjusting the Backlight Compensation . . . . . . . . . . . . . . . . . . .10
Securing the Enclosure Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Warranty and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cable Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Rev 1.01 Document 900.0275
10/05

Introduction

The HD28 Series is Honeywell’s premium line of vandal-resistant, fully-integrated CCTV cameras. The HD28 series enclosure is designed for easy installation and setup.

Before You Begin

Please read this guide carefully before you install the HD28 series camera. Keep this guide for future reference.

Unpack Everything

Check that the items received match those listed on the order form and packing slip. The HD28 series packing box should include, in addition to this User Guide
One HD28 series camera
One hardware kit
One mounting template
One product warranty If any parts are missing or damaged, contact the dealer you purchased the
camera from or call Honeywell Customer Service (see “Warranty and Service” on page 12).

Equipment Required

You will require the following tools to complete the installation:
Phillips screwdriver
Mounting screws. Use mounting screws appropriate to your installation (capable of holding at least twice the weight of the camera).
Rev 1.01 1 Document 900.0275
10/05

Installation

Your HD28 camera is weather-sealed for indoor or outdoor locations. The wiring can be completely concealed for maximum vandal and tamper resistance.

Mounting the Camera

The HD28 camera is designed to be surface mounted on a wall or ceiling.

Preparing the Mounting Surface

1. Affix the mounting template to the mounting surface (see Figure 1).
2. Pre-drill four holes as indicated on the template, using the recommended
hole size for the screws being used.
3. Drill out the conduit hole, if required (see Installing the Conduit Plug).
4. Connect the wiring (see Connecting the Wiring).
5. Mount the camera base to the wall or ceiling using mounting screws (not
supplied) capable of holding at least twice the weight of the camera.
Note Alternate fasteners (preferably stainless steel) can be used, provided
they are not larger than the screw holes on the mounting template.
Figure 1 Mounting Template Guide
t
n
u
o
M
l
d
l
e
a
d
W
n
e
m
m
o
y
c
a
e
r
w
s
i
h
t
Mounting screws appropriate to your installation (not supplied)
Rev 1.01 2 Document 900.0275
10/05

Installing the Conduit Plug

Your HD28 enclosure comes with a conduit plug pre-installed in the 1/2” conduit entry on the back of the housing. This plug may be removed and installed in the side 3/4” conduit entry (see Figure 2).
Figure 2 Conduit Plug Installation
Back View Side View
Screw
Retainer plate
Gasket
Conduit plug
Caution If a conduit is not used for cable routing, install the rubber
grommet in the conduit hole, then slit the grommet and feed the wiring through. Seal the grommet to prevent moisture from entering the housing.
Rev 1.01 3 Document 900.0275
10/05

Wiring Options

Your HD28 Series camera is supplied with a coaxial termination board mounted to the bottom of the enclosure. All connections are made here (see Figure 3).
Figure 3 Wiring Options
Coax Termination Board
Video
Audio
Power
Case/
Not used
Ground

Connecting the Wiring

1. Pull the cables through either the back or the side conduit.
2. To minimize moisture leaking into the housing, position the enclosure with
the conduit pointing down. Apply an appropriate sealant around the conduit connection.

Adjusting the Camera

To adjust the HD28 camera:
1. Apply 12 VDC or 24 VAC to the camera and monitor the video signal.
2. Loosen the screws that lock the gimbal assembly in place (see Figure 4).
3. Adjust the camera carrier to the desired view (see Figure 4).
4. Tighten the screws to lock the gimbal assembly in place.
Note Orient the camera as shown in Figure 4 to maintain the correct
picture orientation.
Rev 1.01 4 Document 900.0275
10/05
Figure 4 Gimbal Adjustment
1
Legend
1 = Pan rotation 2 = Horizontal rotation 3 = Tilt rotation
3
Tilt
1
Pan
3
Horizontal rotation
2
2
Adjusting the Lens Focus
Lenses are pre-focused at the factory but may require a final adjustment after installation in the unlikely event the optical effect of the dome causes a slight defocusing of the lens.
TECH TIP! To check the focus, hold the dome over the lens while making
any adjustments.
To adjust the camera direction, view angle and focus, connect the service monitor cable (supplied) to the video monitor output.
Rev 1.01 5 Document 900.0275
10/05

Dip Switch Functions (Color Cameras, Including TDN Models)

Follow Figure 5 to set the dip switches on a color camera.
Figure 5 Color Camera Switch Settings
Push lock
* Not used. Leave in Off position.
Auto Iris Level Adj. (Varifocal lens). Turn screw clockwise to increase brightness level.
Line-lock adjustment
GAMMAAEFLON
BLC
IRIS
N/A *
AGC MAX
ON
OFF
12345678910
ON
OFF
1 2 3 4 5 6 7 8 9 10
AWB1
AWB2
AWB3
Lower locking screw to set focal length
Factory (default) settings
= ON (up)
= OFF (down)
Upper locking screw to set focus
Video monitor output
Rev 1.01 6 Document 900.0275
10/05

Adjustment Method (Color Cameras)

Switch no. Function Off On
1 GAMMA Off (0.45) On (1.0) 2AE (Automatic
Exposure)
3FLON (Flicker
Less)
4BLC (Backlight
Compensation)
5 IRIS Control Electronic
6 Not used Not used Not used 7 AGC 4 dB 26 dB
Off On (see Manually Setting
Shutter Speed (Color Cameras))
Off On
Off On (Center window)
Auto IRIS
IRIS

White Balance Adjustment Method (Color Cameras)

Symbol SWB8
AWB1
AWB Off Off Off ATW Off On Off Push lock Off On On * Indoor (3200° K) On Off On Outdoor (6500° K) On On On
* To manually set Push lock feature: place a white background in front of
camera and press “Push lock” switch.
Rev 1.01 7 Document 900.0275
SWB9 AWB2
SW10 AWB3
10/05

Manually Setting Shutter Speed (Color Cameras)

To manually set the shutter speed, turn switch #2 to the ON position; then set switch #3, #4, and #5 for the desired shutter speed (see Figure 5).
Shutter speed(s)
1/50 (PAL) 1/60 (NTSC)
1/100 (PAL) 1/120 (NTSC)
1/250 On Off Off Off
1/500 On On Off Off
1/1000 On Off On On
1/2000 On On On On
1/4000 On Off Off On
1/10000 On On Off On
SW2 AE
On Off On Off
On On On Off
SW3 FLON
SW4 BLC
SW5 IRIS
FLON and BLC can be set when switch #2 is set to the OFF position.
Caution Before you adjust the shutter speed, it is important that you
understand how the settings can affect the scene detail.
Rev 1.01 8 Document 900.0275
10/05

Dip switch functions (WDR cameras)

Figure 6 Wide Dynamic Range Camera Switch Settings
Line-lock
Auto Iris level adjustment. If necessary, turn clockwise to increase brightness level.
adjustment
EE/DC IRIS
AWB/ATW
WDR
AGC
MIRROR
Upper locking screw to set focus
Lower locking screw to set focal length
Video monitor output
Factory (default) settings
= ON (up)
= OFF (down)
Note The Wide Dynamic Range camera has been designed for the best
wide dynamic performance and can only be used with vari-focal auto iris lenses.

Adjustment method (Wide Dynamic Range Cameras)

Switch No. Function Off On
1 EE/DC IRIS EE IRIS DC IRIS 2 AWB/ATW AWB ATW 3 WDR (Wide Dynamic Range) Off On 4 AGC Off On
5
Rev 1.01 9 Document 900.0275
MIRROR Off On
10/05

Adjusting the Line Lock (Vertical Phase) for 24 VAC Operation

Phase adjustment may be necessary in multiple camera installations to prevent picture roll when switching between two cameras. To adjust the vertical phase while switching between two cameras, turn the Line lock adjustment screw on one camera until there is no vertical roll. See Figure 5 for color cameras. The Wide Dynamic Range cameras use line lock adjustment buttons to adjust the vertical phase (see Figure 6).
Note If the phase cannot be adjusted to prevent picture roll, reverse the
power polarity.

Adjusting the Backlight Compensation

The backlight compensation (BLC) adjusts the electronic shutter speed of the camera based on the light levels in specific areas of the scene. This adjustment provides better image quality for scenes that are unevenly lit.
To adjust the BLC, set the BLC switch to ON (see Figure 5 for color cameras). Center window weighted.

Securing the Enclosure Cover

1. Slide the hinge towards the base until the screws align with the screw holes
(see Figure 7).
2. Secure the cover in place.
Figure 7 Enclosure Cover Installation
Rev 1.01 10 Document 900.0275
10/05

Routine Maintenance

Use regular liquid cleaners to remove dirt and grime from the dome.
Caution Do not use harsh or abrasive cleaners which can scratch the
polycarbonate dome and reduce visibility for the camera.
If the camera view is obstructed by scratches, remove the front plate and rotate to find an unscratched part of the dome.

Troubleshooting

No video
Check:
Power supply voltage is within the operating specifications for your camera model (see Troubleshooting).
Video connections to the monitor or CCTV system.
The camera connections to the terminal board.
Video switcher or other equipment connections. To eliminate video problems, connect a video monitor directly to the HD28 video output cable.
Noisy video
Check:
Video ground connections
For ground loops.
For additional assistance, call Honeywell Customer Service (see below).
Rev 1.01 11 Document 900.0275
10/05

Warranty and Service

Subject to the terms and conditions listed on the product warranty, during the warranty period Honeywell will repair or replace, at its sole option, free of charge, any defective products returned prepaid.
In the event you have a problem with any Honeywell product, please call Customer Service at 1.800.796.2288 for assistance or to request a Return Merchandise Authorization (RMA) number.
Be sure to have the model number, serial number, and the nature of the problem available for the technical service representative.
Prior authorization must be obtained for all returns, exchanges, or credits. Items
shipped to Honeywell without a clearly identified Return Merchandise Authorization (RMA) number may be refused.
Rev 1.01 12 Document 900.0275
10/05

Specifications

Note Specifications apply to all camera models, unless otherwise noted.
Video Signal Specifications
Pickup device: 1/3 in. CCD Electronic iris: 1/60 (1/50) to 1/100,000 seconds Surge protection: 1.5 kW transient Video output:
Coaxial 1 V p-p @ 75 Ω
Video signal: NTSC or PAL Standards Light sensitivity:
Color, Including TDN 0.6 lux @ f1.5 Wide Dynamic 1.0 lux @ f1.5
Resolution: 480 TV lines Backlight compensation: Center window weighted. User-selectable on/off switch Auto white balance:
(Color cameras only)
Power Requirements
Input voltage (at camera): 15 VDC (11-16V) or 24 VAC Current consumption:
Color, including TDN 3.5W (complete system) Wide Dynamic 4.5W (complete system)
Operating Temperature -13°F to 122°F (-25°C to 50°C) Housing Specifications
Housing dimensions: 6.1 in. diameter (150 mm), overall height 4.13 in. (115 mm) Weight 3.0 lbs. (1.37 kg) Housing material: Die cast aluminum alloy Finish: Urethane powder paint Dome material: Hard coated polycarbonate (clear dome with insert)
Ratings FCC Part 15B
AWB/ATW/Indoor (3200° K), Outdoor (6500° K)
Œ, Meets IP66, UL2044
Rev 1.01 13 Document 900.0275
10/05

Cable Guidelines

Power supply cable maximum length (feet/meters) Cameras with AC/DC power supplies
Wire gauge
Power supply 24 AWG 22 AWG 18 AWG 16 AWG
15 VDC 45/14 73/22 185/56 295/90 24 VAC 408/125 660/201 1674/510 2664/812
Note Calculations are based on an unregulated linear power supply which would be the
worst case. Using a regulated or switching power supply can increase the cable distance. Honeywell recommends using a CSA Certified/UL listed Class 2 power supply to ensure compliance with electrical safety standards.
Coaxial video cable maximum length (feet/meters) Cable type RG-59 RG-6 RG-11 Wire gauge 23 AWG* 18 AWG* 14 AWG* Maximum length 750/229 1500/457 2000/610
* Copper clad steel core, 95% braided shield
Rev 1.01 14 Document 900.0275
10/05
Honeywell Video Systems (Head Office)
2700 Blankenbaker Pkwy, Suite 150
Louisville, KY 40299, USA
www.honeywellvideo.com
+1.800.796.2288
Honeywell Security Australia Pty Ltd.
Unit 5, Riverside Centre, 24-28 River Road West Parramatta, NSW 2150, Australia
www.ademco.com.au
+61.2.8837.9300
Honeywell Video Systems UK Ltd.
Aston Fields Road, Whitehouse Ind Est Runcorn, Cheshire, WA7 3DL, UK
www.security.honeywell.com
+44.1928.754.030
Honeywell Security Asia Pacific
Flat A, 16/F, CDW Building, 388 Castle Peak Road Tsuen Wan, N.T., Hong Kong
www.security.honeywell.com/hk
+852.2405.2323
Honeywell Security France
Parc Gutenberg, 8, Voie La Cardon 91120, Palaiseau, France
www.honeywell-security.fr
+33.01.6932.1090
Honeywell Security Italia SpA
Via della Resistenza 53/59, 20090 Buccinasco Milan, Italy
www.security.honeywell.com/it
+39.02.457.1791
Honeywell Security Espana
Calle Vivero, 5, 28040 Madrid, Spain
www.security.honeywell.com/es
+34.91.102.5900
Honeywell Security Nederland
Netwerk 121 1446 WV Purmerend, Netherlands
www.SecurityHouse.nl
+31.299.410.200
Honeywell Security South Africa
Unit 6 Galaxy Park, 17 Galaxy Avenue, Linbro Park P.O. Box 59904, Kengray, 2100, South Africa
www.honeywell.co.za
+27.11.574.2500
Honeywell Security Germany
Großenbaumer Weg 8 40472 Düsseldorf, Germany
www.honeywell-security.de
+49.211.41.50.90
Honeywell Security Poland
Chmielewskiego 22a, 70-028 Szczecin, Polska
www.ultrak.pl
+48.91.485.40.60
Honeywell Security Czech Republic
Havránkova 33, Brno Dolní Heršpice, 619 00, Czech Republic
www.olympo.cz
+420.543.558.111
Honeywell Security Slovakia Republic
Vajnorskà 142, 83104 Bratislava Slovakia
www.olympo.sk
+421.2.444.54.660
Video Systems
www.honeywellvideo.com
+1.800.796.CCTV (North America only)
© 2005 Honeywell International Inc.
All rights reserved. No part of this publication may be reproduced by any means without written permission from Honeywell Video Systems. The information in this publication is believed to be accurate in all respects. However, Honeywell Video Systems cannot assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change without notice. Revisions or new editions to this publication may be issued to incorporate such changes.
Loading...