Why choose the H450EN Carbon Monoxide (CO) alarm:
• 6 year guarantee, up to 7 year life of alarm
• Superior electrochemical cell sensing technology
• Easy to install and use
• Automatic sensor adjustment function ensures complete accuracy
• Approved to EN50291:2001 and Kitemarked
• Continuous self test function
• Batteries pre-fitted in alarm
• No sensors to replace
• No mains power
• No maintenance
The H450EN is an easy to use and reliable self-contained Carbon Monoxide alarm. Designed for use in all domestic environments such as homes, static caravans and home parks.
The Professional’s Choice
The H450EN is widely regarded as the professional’s choice of Carbon Monoxide alarm and is the chosen unit of numerous major organisations such as gas suppliers, energy companies, local authorities and housing associations etc.
Visual signalling
The H450EN provides a visual signalling in addition to its audible alarm. It enables the user to clearly
distinguish between a dangerous alarm situation, a fault situation like almost empty batteries, and normal operation. This is achieved with the new dual-colour status light, which will flash green to indicate normal operation, and yellow in case of a fault.
Sensor Technology
The latest electrochemical cell technology ensures complete accuracy and reliability giving a 6 year guarantee and up to 7 year life under normal operating conditions. It is officially approved and Kitemarked to the stringent performance requirements of EN50291:2001 - the European Standard for domestic Carbon Monoxide alarms.
Installation
The H450EN is easily attached using the fixing kit provided, with no need for any wiring. No maintenance is required for the full 7 year life of the alarm, with no sensors or any parts to replace.
Maintenance-free Operation
This alarm, including batteries, is guaranteed for 6 years. The batteries are sealed inside the alarm, preventing access by the user and do not require replacement for the whole life of the alarm (up to 7 years).
From Honeywell Analytics, a leading manufacturer and supplier of Carbon Monoxide alarms.
H450EN Self-contained Carbon Monoxide Alarm
All gas appliances should be checked for safety annually.
The H450 has a unique fold down flap on the front of the unit which provides a range of useful information to the user without having to refer back to the comprehensive instruction manual. This includes:
• A description of the potential alarm and fault signals that the unit can give
• What to do if the full alarm sounds and a contact telephone number
• Contact details for our CO Advice Line and CO alarm replacements
• Contact details for Gas Safe Register (ensure gas installers are properly registered)
Page 3
Specification
Detection Principle Electrochemical cell
Operating Voltage 3V
Alarm Life Up to 7 years under normal operating conditions
Alarm Indication Audible and visual alarm
Buzzer Output > 85 decibels (dB) at 1m
Operating Temperature Range -10 to +40°C
Humidity Range 30 to 90% RH non condensing
Alarm Levels 50ppm between 60 to 90 minutes
100ppm between 10 to 40 minutes 300ppm < 3 minutes (as required by EN50291:2001)
Weight 0.1kg (100g) approx.
Dimensions 110mm x 76mm x 34mm
Test Facility Yes
Self Check Function Yes
Ordering Information
Blister Pack (UK/FR/DE/NL) H2109B0181SE
Trade Box (UK/FR/DE/NL) H2109B0180SE
Trade Box (UK/IT/ES/PT) H2109B0180SEB
Customer Branding
For specific volume contracts, we are able to screen print a customer logo on the front of the unit. This is particularly popular with Local Authorities, Housing Associations and Utilities. Terms and conditions apply - full details on request.
From 1 April 2009, all gas engineers in Great Britain and Isle of Man must be on the new Gas Safe Register® to do gas work lawfully. We at
Honeywell Analytics fully support the efforts of Gas Safe Register® and will only recommend the use of Gas Safe registered engineers for the servicing of gas appliances.
The Carbon Monoxide Consumer Awareness Alliance (COCAA) is aimed at raising awareness surrounding the dangers of Carbon Monoxide poisoning in the UK. It is represented by members of the
gas, solid fuel (wood, coal), oil, Carbon Monoxide alarm industries and Carbon Monoxide victim support groups.
Use of the COCAA logo above demonstrates Honeywell Analytics’ commitment to supporting this alliance and helping to promote CO awareness across the UK.
Carbon Monoxide
- Be Alarmed! is the national campaign to encourage the use of properly approved CO
alarms to reduce the number of deaths and injuries caused by Carbon Monoxide. For more information about how to stay safe please visit the campaign website: www.co-bealarmed.co.uk
General Specication
The H450EN is available in a blister pack or trade box.
Contact Us
Honeywell Analytics also provide a UK CO advice line/Call Centre facility which is available Monday to Thursday 8.30am to 5pm and Friday 8.30am to 3.30pm. They will answer any queries on our products and on CO. Please call 01202 645 577 for more information.
Page 4
Technical Services
At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer:
» Full technical support » Expert team on hand to answer
questions and queries
» Fully equipped workshops to ensure
quick turnaround on repairs
» Comprehensive service engineer network » Training on product use and maintenance » Mobile calibration service » Customised programmes of
preventative/corrective maintenance
» Extended warranties on products
Our Product Range
Fixed Gas Monitoring
Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: Commercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites.
» Detection of flammable, oxygen and toxic
gases (including exotics)
» Innovative use of 4 core sensing
technologies – paper tape, electrochemical cell, catalytic bead and infrared
» Capability to detect down to Parts Per
Billion (ppb) or Percent by Volume (%v/v)
» Cost effective regulatory compliance
solutions
Portable Gas Monitoring
When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include:
» Detection of flammable, oxygen and
toxic gases
» Single gas personal monitors – worn by
the individual
» Multi-gas portable gas monitors – used
for confined space entry and regulatory compliance
» Multi-gas transportable monitors – used
for temporary protection of area during site construction and maintenance activities
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG Weiherallee 11a CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com
Americas
Contact Honeywell Analytics:
Find out more
www.honeywellanalytics.com
Europe, Middle East, Africa, India
Life Safety Distribution AG Weiherallee 11a CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com
Americas
Honeywell Analytics Inc.
Europe, Middle East, Africa, India Life Safety Distribution AG Weiherallee 11a CH-8610 Uster Switzerland Tel: +41(0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com
12716
H_H450EN_DS01089_V1_EMEAI
10/10
© 2010 Honeywell Analytics
Find out more www.honeywellanalytics.com
Contact Honeywell Analytics:
UK customer service centre:
Honeywell Analytics Ltd. 4 Stinsford Road Nutfield Industrial Estate Poole, Dorset BH17 0RZ Tel: +44 (0)1202 645577 Fax: +44 (0)1202 665331 consumer@honeywell.com
Technical Services EMEAI: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com
Americas Honeywell Analytics, Inc 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208 detectgas@honeywell.com
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050# Korea Tel: +82 (0)2 6909 0300 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com
www.honeywell.com
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
Loading...