Honeywell DPR100 Data Sheet

Document 49001, p. 1 of 7
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
New!
New Honeywell®DPR100
100-mm Chart Recorder
Fully customize your recorder
with the options and accessories below
Identify the specific recorder and options you would like to order from each option table. Complete the Key Numbers Form below to determine your custom order number by using the “Key No.” in each of the seven tables on the following pages. Then call our Customer Contact Department to place your order.
Note: Tables 3 and 7 use a composite of option key numbers. A complete order number must have the specified number of digits filled in. There are restrictions to options based on other selections. Please see the “notes” section when indicated for further information.
Universal input recorder is ideal for most process applications
Fully documented charts provide a complete record that’seasy to read
Display digital values or bar graph for real-time data at a glance
ITEM No.
MATH
VOLTAGE OUTPUTS
LOGIC CHART DOOR ADDITIONAL
FUNCTION INPUTS CASSETTE and CASE OPTIONS
TABLE
TABLE 1
TABLE 2 TABLE 3
TABLE 4 TABLE 5 TABLE 6 TABLE 7
5 digits 1 digit 1 digit 2 digits 1 digit 1 digit 1 digit 5 digits
{ _ _ _ _ _ } — { _ } { _ } { _ _ } { _ } { _ } { _ } — { _ _ _ _ _ } — 0 0
KEY NUMBERS FORM
Honeywell—Reg TM Honeywell Inc
Example of a custom order number for item number DP101. Complete order with the following options:
Item Table
“Pen Recorder EX-80660-00”, choose key number DP101
Table 1: Math Function
“Math Package 2”, choose key number 2
Table 2: Voltage
“85 to 250 VAC/DC, 60Hz, chart speed: inch/hr”, choose key number B
Table 3: Outputs
“Universal Communication”,choose key number 1_ “Alarm relay-None”, choose key number _0 Complete key number: 10
Table 4: Logic Inputs
“Remote Contacts (4)”, choose key number B
Table 5: Chart Cassette
“Fan Fold”, choose key number Z
Table 6: Door and Case
“Portable Case”, choose key number 5
Table 7: Additional Options
“Power Supply-None”, choose key number 0_ _ _ _ “Cover-None”, choose key number _0_ _ _ “Approval-None”, choose key number _ _0_ _ “Math Inputs-None”, choose _ _ _0_ “Certification-None”, choose key number _ _ _ _0 Complete key number: 00000
Final Order Number:
DP101 - 2 - B - 10 - B - Z - 5 - 00000 - 00
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49001, p. 2 of 7
For assistance with options
and determining your custom order number,
call our Application Specialists.
More Information
C-P Catalog No. Description ITEM No.
EX-80660-00 One pen recorder DP101 EX-80660-10 Two pen recorder DP102 EX-80660-20 Two pen recorder DP103 EX-80660-30 Six channel recorder DM106
Note: The units are built with universal input and
are delivered with 250 ohm resistors to convert input current signal 4 to 20 mA into 1 to 5 VDC (or 0 to 5 VDC). These are packed in the product accessories.
Item
Key No.
Option Description
DP101 DP102 DP103 DM106
Standard Channel difference, square root ◗◗◗◗ 0 Math package 1 Add, multiply, divide ◗◗◗◗ 1
Math package 2
Pkg. 1, plus F0sterilization, group
◗◗◗◗ 2
average, totalizer, gas/liquid mass flow Pkg. 2, plus Integration, group max,
Math package 3 min, max-min, steam flow totalization,
◗◗◗◗ 3
energy consumption
Math package 4
Pkg. 3, plus RH, 10x, envelope, timers,
◗◗◗◗ 4
carbon potential
Item
Key No.
Option and Description
DP101 DP102 DP103 DM106
85 to 264 VAC/DC, 50 Hz. Chart speed: mm/hr (see Note 1) ◗◗◗◗ A 85 to 250 VAC/DC, 60 Hz. Chart speed: inch/hr ◗◗◗◗ B 24 VAC/DC, 50 Hz. Chart speed: mm/hr ◗◗◗◗ E 24 VAC/DC, 60 Hz. Chart speed: inch/hr ◗◗◗◗ F 48 VAC/DC, 50 Hz. Chart speed: mm/hr ◗◗◗◗ G 48 VAC/DC, 60 Hz. Chart speed: inch/hr ◗◗◗◗ H
Note: Models DP101, 102, and 103 Pen recorders are supplied with three analog inputs when Math Function option is ordered. Additional 3 inputs can be selected by specifying TABLE 7 key numbers _ _ _ A _ selec­tion.
Note 1: This option is not available with TABLE 7 key number _ _ C _ _ selection.
ITEM NUMBER TABLE
VOLTAGE - TABLE 2
MATH FUNCTION - TABLE 1
The chart speed and frequency can be modified on the unit from key pad.
Copyright © 2002 all rights reserved
800-323-4340 www.coleparmer.com
International fax: 847-549-1700 In Canada, call Labcor at 800-363-5900
In the UK, call Cole Parmer Instrument Co. Ltd. at 0500 345 300
Document 49001, p. 3 of 7
Item
Key No.
Option Description
DP101 DP102 DP103 DM106
2 inputs ◗◗◗◗ A
Remote contacts 4 inputs ◗◗◗◗ B
None ◗◗◗◗ 0
Item
Key No.
Option Description
DP101 DP102 DP103 DM106
Fan fold ◗◗◗◗ Z Roll ◗◗◗◗ R
LOGIC INPUTS - TABLE 4
CHART CASSETTE - TABLE 5
Item
Key No.
Option Description
DP101 DP102 DP103 DM106
RS422/485 Modbus RTU,
Universal communication RS422/485 ASCII, RS232/ ◗◗◗◗ 1_
V24 ASCII (Modem)
None ◗◗◗◗ 0_
4-20 mA Auxiliary outputs 2 outputs ◗◗◗◗ 2_ 4-20 mA Auxiliary outputs,
2 outputs (see Note 2) ◗◗◗◗ 3_
plus Universal communication
6 alarm output ◗◗◗◗ _A
12 alarm output (see Note 3) ◗◗◗◗ _B
Alarm relays:
2 alarm output ◗◗◗◗ _C
None ◗◗◗◗ _0
OUTPUTS - TABLE 3
Use a composite of options for a 2-digit key number for this table.
Note 2: This option is not available with TABLE 3 key numbers _ A, _ B, and _ C selections. Note 3: This option is not available with TABLE 3 key numbers 1 _, 2 _, and 3 _ selections.