Thank you for purchasing a Honeywell Dehumidifier. This User Manual is intended to provide you
with important information needed to set up, operate, maintain and troubleshoot this product.
SAFETY RULES
WARNING -- READ AND SAVE THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.
The user of electrical products may create hazards that include, but are not limited to injury, fire,
electrical shock. Failure to follow these instructions may damage and/ or impair its operation and
void the warranty. In case there is any inconsistency or conflict between the English version and any
other language version of the content of this material, the English version shall prevail.
When using electrical appliances, basic safety precautions should always be followed:
DO NOT touch the dehumidifier or the electrical plug with wet hands.
•
Check the household voltage to ensure it matches the appliance's specification.
•
Before operating, remove all packaging material and check for any damage that may have
•
occurred during shipping.
DO NOT operate any product with a damaged cord or plug.
•
DO NOT use an extension cord with this appliance.
•
DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from
•
areas where it may be tripped over.
Always unplug the dehumidifier before emptying the water tank.
•
The water collected in the tank must be discarded. The water should never be used for drinking.
•
Always unplug the dehumidifier and remove the water from the water tank before cleaning,
•
servicing or relocating the unit.
Remove the power cord from the electrical receptacle by grasping and pulling on the power cord
•
plug-end only, never pull the cord.
This appliance has been manufactured for use in domestic environments and must not be used
•
for other purposes.
DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are
•
used or stored.
This dehumidifier is designed for indoor residential applications only. It should not be used for
•
commercial or industrial applications.
DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier, as
•
this may cause danger and void the warranty.
DO NOT cover the air inlet or outlet on the appliance as this may cause the unit to fail.
•
DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage
•
the product and could cause electrical shock or fire.
EN
1
SAFETY RULES (CONTINUED)
DO NOT let children play with this appliance, packaging or included plastic bag.
•
If the unit is damaged or it malfunctions, do not continue to operate it. Unplug the product from
•
the electrical outlet. Refer to the troubleshooting section and contact the customer support
center.
Always place the dehumidifier on a leveled floor.
•
Never install the product near a bathtub or any water container.
•
Store in a dry area, away from direct sunlight, when not in use.
•
This appliance and its packaging materials are not intended for use by persons (including
•
children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instructions concerning the use of
the appliance by a person responsible for their safety.
Always grip the side handles and keep the unit upright when transporting from room to room –
•
DO NOT tilt the product on its side or upside-down.
If the dehumidifier was transported tilted on its side, you must position it upright again and wait
•
at least 4 hours before using it.
WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid
•
state speed control device.
EN
2
HOW A DEHUMIDIFIER WORKS
When the dehumidifier is switched ON, a fan pulls moisture-laden air into the dehumidifier where it
passes through dehumidifying coils inside the unit. These coils condense moisture from the air and
collect it in the water tank. The dry air is then exhausted from the dehumidifier. The air flows through
the air vents of the dehumidifier into the room as dry, warm air.
IMPORTANT: The dehumidifier is designed to operate between 41°F (5°C) and 89°F (32°C). The
dehumidifier’s performance may be greatly reduced if room temperatures exceed this temperature
range.
SELECTING A LOCATION - IMPORTANT
Before using the dehumidifier, place the unit UPRIGHT for at least 1 hour before use to allow the
•
refrigerant to stabilize. If the unit was tilted on its side or upside-down during transportation, set
the unit upright for 4 hours before use.
For optimal efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors,
•
windows and other outside entrances to the room closed.
Place the dehumidifier at least 12 inches (31cm) away from other objects (e.g. curtains or
•
furniture) that may restrict airflow from the front or through the air vents of the unit.
The dehumidifier must be positioned on a level floor.
•
12 inches (31cm)
EN
3
SELECTING A LOCATION - IMPORTANT (CONTINUED)
IMPORTANT: The effectiveness of the dehumidifier can be influenced by different factors. One factor
is the rate at which new, moisture-laden air enters the room and the amount of air circulating in and
out of the area to be dehumidified. For example, if a door to a basement is constantly opened, letting
new, moisture-laden air into the room, dehumidification will take longer than if the door was kept
closed. If the dehumidifier is in a room with a storage closet or cabinets, it will have little or no effect
in drying the inside of the storage closet or cabinets unless there is adequate circulation of air in and
out of these spaces. To dehumidify these spaces, open the storage door or cabinet doors to allow air
circulation. You may find that installing a second dehumidifier may be required for larger enclosed
areas.
UNPACKAGING THE DEHUMIDIFIER
This Dehumidifier is packaged with a colored or transparent
tape to secure some parts during transportation.
Remove all the colored or transparent packaging tape from
the unit.
Remove this packaging tape before use. If you do not remove
it, the Dehumidifier will not switch ON and a blinking red
light will appear.
There is a Float (without polyfoam) located inside the water
tank. This works to sense the level of the water inside the
tank.
This illuminates when the Water Tank is full of water or if the Water Tank is not positioned properly
on the unit. To switch off , empty the Water Tank and check that the tank is secured properly into
place.
Defrost Light
This indicates that the room temperature is too low. Increase the room temperature or wait until the
temperature increases to switch off and to turn the dehumidifier on again.
Fan Speed Control
Press to set the desired fan speed.
There are 2 fan speeds to select from: High || / Low |
A higher fan speed results in faster moisture removal.
EN
7
USE & OPERATION (CONTINUED)
CONTROL PANEL (CONTINUED)
Timer Control
The dehumidifier can be set to automatically switch ON or OFF after a selected period of time
(between 124 hour intervals). The Timer hours selection is displayed on the Timer/Temperature
Display Screen.
NOTE: Before setting the Timer control, make sure there is power to the unit.
AutoOff Timer:
While the unit is running, first press and then tap or hold the ▲ or ▼ to select the number of
hours you want the unit to run before it switches off. The unit automatically switches off after the set
time period has elapsed. You must repeat the Timer set up procedures to reset the Timer for next use,
if needed.
AutoOn Timer:
When unit is in standby mode, press and ▲ or ▼ to select the number of hours until you
want the unit to automatically start running. The previous fan speed and humidity setting will be
maintained. The unit will continue running until the water tank is full (unless the unit is set up for
continuous draining) or until you switch it off manually.
NOTE: To cancel any Timer settings, simply press and then tap or hold the ▲ or ▼ until the
Timer display shows '0'.
EN
8
USE & OPERATION (CONTINUED)
CONTROL PANEL (CONTINUED)
Temperature / Timer Display
When the unit is switched ON, the Temperature / Timer Display shows the current room temperature.
Pressing the Timer temporarily switches the display to show the Timer setting (in hours) for
10 seconds, before reverting back to the temperature display.
Humidity Control Setting
When the unit is switched ON, the Humidity Display shows the current humidity percentage. Press
or ▼ to select your preferred humidity level. The humidity is adjusted in increments of 5% by
▲
pressing ▲ or ▼. The adjustable Relative Humidity (RH) range is between 30% RH to 90% RH. Ten
seconds after setting the preferred humidity setting, the display will revert back to displaying the
current humidity.
Recommended Settings: It is recommended to leave the unit running at 30% humidity at High Fan
Speed during the first 2 to 3 days until damp odors are removed. After a few days when the Relative
Humidity has been reduced to a more comfortable level, press ▲ or ▼ to choose a higher RH% that
maintains a comfortable humidity level thereafter. A recommended healthy humidity level is between
40% and 50%.
NOTE: The humidity sensor senses current humidity in the surrounding area. It is normal for a 5°F to
9°F (3°C to 5°C) variance in the humidity sensitivity from the sensor.
°C/ °F Display Options
Press °C/ °F to change the Temperature Display from degrees Celcius °C to degrees Fahrenheit °F.
EN
9
USE & OPERATION (CONTINUED)
DRAINING THE WATER
WARNING: Always drain and discard water collected from dehumidification.
The water is not clean and cannot be used for drinking.
1. Draining water collected in the Water Tank
The condensed water can be collected directly into the water tank. When the water tank is full, the
dehumidifier will automatically shut OFF and will illuminate on the control panel followed by a
beeping sound.
IMPORTANT: Do not move the dehumidifier when the water tank is full as it will be heavy and can
cause water spillage.
Locate the water tank at the front of the dehumidifier.
1.1
Gently pull the water tank out and place it on the
floor. Two stands located at the bottom of the water
tank will automatically extend to help balance the
tank on the floor.
Grip the handle inside the water tank and carry the
1.2
water tank to a sink to empty.
Water Tank Handle
Replace the empty water tank back into the front
1.3
of the dehumidifier. Please make sure that the tank
is properly positioned. The safety feature ensures
that any misalignment of the tank and the unit will
prevent the unit from turning back on.
Stands*
Float
(without polyfoam)
IMPORTANT: Improper alignment or positioning of the water tank will cause the unit to pause
operation, the warning light on top of the dehumidifier will illuminate followed by a beeping sound,
until the water tank is fitted properly.
NOTE: There is a Float (without polyfoam) inside the water tank that senses the water level to
automatically stop dehumidification when the water tank is full. Make sure the Float is positioned
correctly inside the water tank by ensuring it lies level with the top edge of the water tank.
2. Continuous Water Drainage – Using a Standard Garden Hose (Garden Hose not included)
For continuous water drainage with a standard garden hose, you will need a garden hose and a
suitable water drain (e.g. a sink or drain hole at floor level) near the dehumidifier.
2.1
Locate the drain outlet on the back of the unit.
2.2
Unscrew and remove both drain cap and rubber
stopper.
2.3
Locate the female connector at one end of the
garden hose. Insert the garden hose onto the drain
outlet of the dehumidifier. Screw and tighten the
garden hose connector onto the threaded part of
the drain outlet, making sure the hose connector
is secured to ensure there will be no leaks. If there
are leaks, the hose and the drain outlet may not be
connected properly. Disconnect, replace and tighten
the garden hose connector again.
2.4
Position the other end of the garden hose in the sink
or drain. Make sure the hose is not bent or kinked
which might stop the water flow. Make sure the hose
is secured over the drain and will not fall out of place
causing unwanted water spillage.
2.1
Drain Outlet
2.32.4
Garden Hose
2.2
Drain Cap
Rubber
Stopper
IMPORTANT: Make sure water can flow down the garden hose by keeping the hose angled down and
free of bends or kinks.
IMPORTANT: If you stop using the continuous drain function, the drain cap and rubber stopper must
be replaced before use to prevent leakage.
3. Continuous Water Drainage – Using the Drain Pump Option (Drain Tube included)
The Continuous Drain Pump is available if you want to use the continuous drain function, but the
drain is further away, or located above the dehumidifier. A 16.4ft (5m) long drain tube*
can be attached to the continuous drain pump located on the back side of the dehumidifier.
When the water level in the water tank reaches a certain level, the drain pump will automatically
pump the water out of the tank to the drain. This allows you to drain water condensation vertically or
horizontally, even if the drain is located above the dehumidifier.
Unwrap the drain tube from the dehumidifier and locate the drain tube connector on one end
3.1
of the drain tube.
Insert the drain tube connector into the drain pump hole located on the rear side of the
3.2
dehumidifier.
Push the drain tube connector into the drain pump hole until you hear a “click” sound.
3.3
Place the other end of the drain tube into the sink or drain. The water can be pumped up to
3.4
16.4ft (5m) vertically or horizontally.
NOTE: DO NOT use an alternative drain tube that is longer than the one provided with the
unit.
To disconnect the drain tube, press the release button above the drain pump hole while
3.5
pulling the drain tube connector away from the drain pump hole.
Drain
Tube
3.1
Drain Tube
Connector
3.33.5
Release
Button
3.2
Drain Pump
Hole
*Continuous Drain Tube is included in Dehumidifier models with Continuous Drain Pump feature only.
EN
12
USE & OPERATION (CONTINUED)
CLEANING & MAINTENANCE
WARNING: Always switch OFF the dehumidifier and unplug it from the electrical outlet before
attempting any cleaning or maintenance of this product.
Appliance Maintenance:
• Switch OFF the appliance before disconnecting the power supply.
• Only use a soft cloth to clean the appliance.
Dust Filter Maintenance:
The Dust Filter located at the top of the unit helps to remove dust particles from the air. A dirty filter
locked by dust particles can reduce the efficiency of the dehumidifier. For optimum dehumidification,
it is recommended to clean the dust filter every 2 weeks:
Switch OFF the dehumidifier. Press down on the
1.
dust filter with 2 hands to release the dust filter
from the top of the unit.
Rinse the dust filter under running water, or
2.
vacuum away the dust with a vacuum cleaner.
After cleaning the dust filter, dry in a cool, shaded
3.
place, then carefully reinstall into the unit.
End of Season Storage & Maintenance:
If the appliance will not be used for an extended period of time:
Switch OFF the unit and unplug from the electrical power outlet.
•
Empty the water tank and let it dry. If your dehumidifier is connected to the continuous drain
•
hose, you mush disconnect the hose, dry and then replace the drain cap and rubber stopper back
into the drain outlet.
Remove the air filter and clean with water. Let the air filter dry and reinstall back into the unit.
•
Make sure all parts of the dehumidifier and accessories are dry before storage.
•
Cover the dehumidifier with a cloth/ plastic bag before storage, to protect the surface from dust
•
and scratches.
It is recommended to coil the power cord and store it off the floor to ensure it is protected from
•
bends and kinks.
Store the unit upright in a dry location, away from direct sunlight.
•
AUTO RESTART FUNCTION
This unit is equipped with an Auto Restart feature. When there is a power outage, the dehumidifier
will automatically resume its previous settings upon regaining power.
13
EN
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer service.
PROBLEMPOSSIBLE CAUSESOLUTION
No electricity.Check for power.
Dehumidifier
does not start
Unit runs but
the humidity
level does
not decrease
The power cord is not
properly plugged in.
The safety switch
activated on the
electrical plug.
The humidity level setting
is too high.
A door or window is open,
letting in new moisture.
There are other sources
of humidity in the room
(e.g. boiling water in pot).
The temperature in the
room is too low.
Remove and reconnect the power cord.
Reset the safety switch and wait for 3 minutes to
pass. Contact customer service if problem persists.
Decrease the humidity level setting.
Make sure all windows or doors to the
outside are closed and tightly sealed.
Switch on the dehumidifier when these
sources are not present.
The dehumidifier is designed to operate between
41°F (5°C) and 89°F (32°C). Moisture removal is
greatly reduced if room temperatures exceed this
temperature range.
The dust filter is dirty/
blocked.
Air outlet or intake is
blocked.
Clean the dust filter.
Remove blockage.
EN
14
TROUBLESHOOTING GUIDE (CONTINUED)
PROBLEMPOSSIBLE CAUSESOLUTION
Dehumidifier
runs constantly/
does not stop
Water Tank
Full is
illuminated
and the unit is
beeping
The unit is
blowing cold air
out of the top
vent
Defrost
is illuminated
Area to be dehumidified
is too large.
A door or window is open,
letting in new moisture.
The water tank is full.Empty the water tank.
The water tank is not in
the correct position.
The purpose of the top
air vent is to distribute air
into the room.
The temperature of the
room is too low.
The capacity of your dehumidifier may not be
adequate for the room it is used in. It is recommended
to add an extra dehumidifier for large areas.
Make sure all windows or doors to the
outside are closed and tightly sealed.
Position the water tank correctly into the unit. Unit
will not operate until the water tank is secure in place.
The temperature of the air from the vent depends
on the room environment and other factors. It can
fluctuate and this is normal. No action required.
The dehumidifier may not work effectively in
low temperature environments. Increase the
temperature of the room or wait until the
temperature increases to use the dehumidifier.
Frost appears
on the coils
Connected
the continuous
drain but
the water
condensation is
not draining out
the tube
Dehumidifier has been
recently turned on in low
room temperatures
(usually below 41°F
(5°C)).
Some floors may have
an uneven surface
which may affect the
continuous drainage
function
This is normal. Frost will disappear in an hour
or so after the dehumidifier is switched OFF.
Raise the front of the Dehumidifier ½ to 1 inch
(1.27 cm to 2.54 cm) from the floor. The water
condensation will drain out the back hose and not
into the bucket.
15
EN
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.