SURSENSE
Ultra Low Pressure Sensors
Millivolt Output
High Accuracy Compensation
Full Scale Pressure Ranges
FEATURES
• Position sensitivity to
± 5 mV/g, typical
• Offset Warm-up drift
< ± 50 mV, typical
• Temperature
Compensated over
0°C to +50 °C
• Available in Gage and
Differential Pressure
Ranges
• Long Term Stability
< ± 100 µV, typical
• Combined Linearity and
Hysteresis Error
< ± 0.25 % Span
TYPICAL APPLICATIONS
• Medical Instrumentation
• HVAC
• Industrial Instrumentation
• Environmental Controls
WARNING
PERSONAL INJURY
DO NOT USE these products
as safety or emergency stop
devices or in any other
application where failure of the
product could result in
personal injury.
Failure to comply with these
instructions could result in
death or serious injury.
The DCXL line of ultra low pressure sensors is based upon
SURSENSE, a proprietary technology, which reduces all output offset or
common mode errors.
These sensors use a silicon micromachined sensing element which
features a unique stress concentration enhanced structure to provide a
highly stable linear output that is proportional to applied pressure. Output
offset errors due to changes in temperature, warm-up, long term stability
and position sensitivity have all been significantly reduced when compared
to conventional sensors.
The DCXL Series sensors provide a precision calibrated ratiometric
millivolt output using the enhanced stability of SURSENSE technology .
Each sensor features calibrated offset, full scale span and thermal error
calibration to ensure the highest possible accuracy for flow pressure
measurement. These highly stable sensors feature an industry standard
ported package with improved stress isolation for printed circuit board
mount applications.
Product is patented by US patent 6023978.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
not use this document as product installation information.
• Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious
injury.
DCXL Series
Sensing and Control
SURSENSE Ultra Low Pressure Sensors
Millivolt Output
DCXL Series
DCXL Electrical Specifications at 12 Vdc Excitation, 25 °C
Min. Typ. Max. Units
Excitation Voltage 3.0 12.0 16.0 Vdc
Common Mode Voltage, % Excitation -- 50 -- %
Span*except DCXL01DN 19 20.0 21.0 mV
Span*DCXL01DN 9.0 10.0 11.0 mV
Null* - 500 0 +500 µV
Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])**
except DCXL01DN
Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])**
DCXL01DN
Span Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** -200 0 +200 µV
Linearity, Hysteresis Error*** -- 0.05 0.25 %Span
Operating Temperature -25 +85
Storage Temperature -40 +125
Offset Warm-up Shift****except DCXL01DN -Offset Warm-up Shift****DCXL01DN --
Offset Position Sensitivity (±1g) except DCXL01DN,
DCXL05DN and DCXL10DN
Offset Position Sensitivity (±1g) DCXL01DN
Offset Position Sensitivity (±1g) DCXL05DN, DCXL10DN
Offset Long Term Stability (1 year) except DCXL01DN -Offset Long Term Stability (1 year) DCXL01DN --
*Note 1: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 1.0 V to 6.0 V.
**Note 2: Shift is relative to 25 °C
***Note 3: Measured at ½ full scale rated pressure using BFSL
****Note 4: Shift is within the first hour of excitation applied to the device.
DCXL Series Pressure Ratings in H2O (by Catalog Listing)
DCXL- 01D 05D 10D 20D 30D
OPERATING PRESSURE RANGE 1.0 5.0 10.0 20.0 30.0
PROOF 100 150 150 300 450
BURST 200 300 300 450 750
COMMON MODE 50 50 50 50 50
DCXL Series Resistance (by Catalog Listing)
DCXL 01D 05D 10D 20D 30D UNIT
INPUT RESISTANCE 4.5 10 13 10 12 KO
OUTPUT RESISTANCE 1.5 1.5 1.5 2 1.5 KO
-150
- 250
--
--
--
--
0
± 50
± 100
± 5
± 50
± 10
± 100
± 200
+150
+250
-- µV
-- µV
--
-- µV
-- µV
-- µV
-- µV
µV
µV
°C
°C
µV
2 Honeywell • Sensing and Control