DCXL
SURSENSEâ Ultra Low Pressure Sensors
Millivolt Output
High Accuracy Compensation
Full Scale Pressure Ranges
FEATURES
DCXL Series
∙Position sensitivity to
± 5 mV/g, typical
∙Offset Warm-up drift < ± 50 mV, typical
∙Temperature Compensated over 0°C to +50 °C
∙Available in Gage and Differential Pressure Ranges
∙Long Term Stability < ± 100 µV, typical
∙Combined Linearity and Hysteresis Error
< ± 0.25 % Span
TYPICAL APPLICATIONS
∙Medical Instrumentation
∙HVAC
∙Industrial Instrumentation
∙Environmental Controls
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
The DCXL line of ultra low pressure sensors is based upon SURSENSEâ, a proprietary technology, which reduces all output offset or common mode errors.
These sensors use a silicon micromachined sensing element which features a unique stress concentration enhanced structure to provide a highly stable linear output that is proportional to applied pressure. Output offset errors due to changes in temperature, warm-up, long term stability and position sensitivity have all been significantly reduced when compared to conventional sensors.
The DCXL Series sensors provide a precision calibrated ratiometric millivolt output using the enhanced stability of SURSENSEâ technology. Each sensor features calibrated offset, full scale span and thermal error calibration to ensure the highest possible accuracy for flow pressure measurement. These highly stable sensors feature an industry standard ported package with improved stress isolation for printed circuit board mount applications.
Product is patented by US patent 6023978.
WARNING
MISUSE OF DOCUMENTATION
∙The information presented in this product sheet is for reference only. Do not use this document as product installation information.
∙Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Sensing and Control
SURSENSEâ Ultra Low Pressure Sensors |
|
|
|
|
|
|
|
|
||||||||||||||||
Millivolt Output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DCXL Series |
||||
DCXL Electrical Specifications at 12 Vdc Excitation, 25 ° C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Min. |
|
|
Typ. |
|
Max. |
Units |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Excitation Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
3.0 |
|
|
|
12.0 |
|
16.0 |
Vdc |
||||
Common Mode Voltage, % Excitation |
|
|
|
|
|
|
|
-- |
|
|
|
|
50 |
|
-- |
|
% |
|
||||||
Span*except DCXL01DN |
|
|
|
|
|
|
|
|
|
|
|
|
19 |
|
|
|
|
20.0 |
|
21.0 |
mV |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Span*DCXL01DN |
|
|
|
|
|
|
|
|
|
|
|
|
9.0 |
|
|
|
10.0 |
|
11.0 |
mV |
|
|||
Null* |
|
|
|
|
|
|
|
|
|
|
|
|
|
- 500 |
|
|
|
0 |
|
+500 |
µV |
|||
Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
except DCXL01DN |
|
|
|
|
|
|
|
|
|
|
|
|
-150 |
|
|
|
-- |
|
+150 |
µV |
||||
Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
DCXL01DN |
|
|
|
|
|
|
|
|
|
|
|
|
|
- 250 |
|
|
|
0 |
|
+250 |
µV |
|
||
Span Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** |
|
-200 |
|
|
|
0 |
|
+200 |
µV |
|
||||||||||||||
Linearity, Hysteresis Error*** |
|
|
|
|
|
|
|
|
|
|
-- |
|
|
|
|
0.05 |
|
0.25 |
%Span |
|
||||
Operating Temperature |
|
|
|
|
|
|
|
|
|
|
|
|
-25 |
|
|
|
|
|
+85 |
|
°C |
|
||
Storage Temperature |
|
|
|
|
|
|
|
|
|
|
|
|
-40 |
|
|
|
|
|
+125 |
°C |
|
|||
Offset Warm-up Shift****except DCXL01DN |
|
|
|
|
|
|
|
-- |
|
|
|
|
± 50 |
|
-- |
|
µV |
|
||||||
Offset Warm-up Shift****DCXL01DN |
|
|
|
|
|
|
|
-- |
|
|
|
|
± 100 |
|
-- |
|
µV |
|
||||||
Offset Position Sensitivity (±1g) except DCXL01DN, |
|
|
|
-- |
|
|
|
|
± 5 |
|
-- |
|
µV |
|
||||||||||
DCXL05DN and DCXL10DN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Offset Position Sensitivity (±1g) DCXL01DN |
|
|
|
|
|
|
-- |
|
|
|
|
± 50 |
|
-- |
|
µV |
|
|||||||
Offset Position Sensitivity (±1g) DCXL05DN, DCXL10DN |
|
|
|
-- |
|
|
|
|
± 10 |
|
-- |
|
µV |
|
||||||||||
Offset Long Term Stability (1 year) except DCXL01DN |
|
|
|
-- |
|
|
|
|
± 100 |
|
-- |
|
µV |
|
||||||||||
Offset Long Term Stability (1 year) DCXL01DN |
|
|
|
|
|
|
-- |
|
|
|
|
± 200 |
|
-- |
|
µV |
|
|||||||
*Note 1: |
The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 1.0 V to 6.0 V. |
|||||||||||||||||||||||
**Note 2: |
Shift is relative to 25 °C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
***Note 3: |
Measured at ½ full scale rated pressure using BFSL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
****Note 4: Shift is within the first hour of excitation applied to the device. |
|
|
|
|
|
|
|
|
||||||||||||||||
DCXL Series Pressure Ratings in H2O (by Catalog Listing) |
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
DCXL- |
|
|
|
|
01D |
|
|
05D |
|
10D |
|
20D |
30D |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
OPERATING PRESSURE RANGE |
|
1.0 |
|
|
5.0 |
|
|
10.0 |
|
|
20.0 |
30.0 |
|
|
|
|
||||||||
PROOF |
|
|
|
|
100 |
|
150 |
|
|
150 |
|
|
300 |
450 |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
BURST |
|
|
|
|
200 |
|
300 |
|
|
300 |
|
|
450 |
750 |
|
|
|
|
||||||
COMMON MODE |
|
|
|
50 |
|
|
50 |
|
|
50 |
|
|
50 |
50 |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
DCXL Series Resistance (by Catalog Listing) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
DCXL |
|
01D |
|
05D |
|
10D |
|
20D |
|
30D |
|
UNIT |
|
|
|
|
|
|
|
|
||||
INPUT RESISTANCE |
4.5 |
|
10 |
|
|
13 |
|
10 |
|
12 |
|
|
KO |
|
|
|
|
|
|
|
|
|||
OUTPUT RESISTANCE |
1.5 |
|
1.5 |
|
1.5 |
|
2 |
|
1.5 |
|
|
KO |
|
|
|
|
|
|
|
|
2 Honeywell ∙ Sensing and Control