Honeywell DCXL User Manual

查询DCXL供应商
SURSENSE
Ultra Low Pressure Sensors
Millivolt Output High Accuracy Compensation Full Scale Pressure Ranges
FEATURES
Position sensitivity to ± 5 mV/g, typical
Offset Warm-up drift < ± 50 mV, typical
Temperature
Compensated over 0°C to +50 °C
Available in Gage and Differential Pressure Ranges
Long Term Stability < ± 100 µV, typical
Combined Linearity and Hysteresis Error < ± 0.25 % Span
TYPICAL APPLICATIONS
Medical Instrumentation
HVAC
Industrial Instrumentation
Environmental Controls
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
The DCXL line of ultra low pressure sensors is based upon SURSENSE, a proprietary technology, which reduces all output offset or common mode errors.
These sensors use a silicon micromachined sensing element which features a unique stress concentration enhanced structure to provide a highly stable linear output that is proportional to applied pressure. Output offset errors due to changes in temperature, warm-up, long term stability and position sensitivity have all been significantly reduced when compared to conventional sensors.
The DCXL Series sensors provide a precision calibrated ratiometric millivolt output using the enhanced stability of SURSENSE technology . Each sensor features calibrated offset, full scale span and thermal error
calibration to ensure the highest possible accuracy for flow pressure measurement. These highly stable sensors feature an industry standard ported package with improved stress isolation for printed circuit board mount applications.
Product is patented by US patent 6023978.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as product installation information.
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Sensing and Control
SURSENSE Ultra Low Pressure Sensors
Millivolt Output
DCXL Series
DCXL Electrical Specifications at 12 Vdc Excitation, 25 °C Min. Typ. Max. Units
Excitation Voltage 3.0 12.0 16.0 Vdc Common Mode Voltage, % Excitation -- 50 -- % Span*except DCXL01DN 19 20.0 21.0 mV Span*DCXL01DN 9.0 10.0 11.0 mV Null* - 500 0 +500 µV Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])**
except DCXL01DN Offset Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])**
DCXL01DN Span Temperature Shift (0 °C to +50 °C [+32 °F to +122 °F])** -200 0 +200 µV Linearity, Hysteresis Error*** -- 0.05 0.25 %Span Operating Temperature -25 +85 Storage Temperature -40 +125 Offset Warm-up Shift****except DCXL01DN -­Offset Warm-up Shift****DCXL01DN --
Offset Position Sensitivity (±1g) except DCXL01DN, DCXL05DN and DCXL10DN
Offset Position Sensitivity (±1g) DCXL01DN Offset Position Sensitivity (±1g) DCXL05DN, DCXL10DN Offset Long Term Stability (1 year) except DCXL01DN -­Offset Long Term Stability (1 year) DCXL01DN --
*Note 1: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 1.0 V to 6.0 V. **Note 2: Shift is relative to 25 °C ***Note 3: Measured at ½ full scale rated pressure using BFSL ****Note 4: Shift is within the first hour of excitation applied to the device.
DCXL Series Pressure Ratings in H2O (by Catalog Listing)
DCXL- 01D 05D 10D 20D 30D OPERATING PRESSURE RANGE 1.0 5.0 10.0 20.0 30.0 PROOF 100 150 150 300 450 BURST 200 300 300 450 750 COMMON MODE 50 50 50 50 50
DCXL Series Resistance (by Catalog Listing)
DCXL 01D 05D 10D 20D 30D UNIT INPUT RESISTANCE 4.5 10 13 10 12 KO OUTPUT RESISTANCE 1.5 1.5 1.5 2 1.5 KO
-150
- 250
--
--
--
--
0
± 50 ± 100
± 5 ± 50 ± 10 ± 100 ± 200
+150
+250
-- µV
-- µV
--
-- µV
-- µV
-- µV
-- µV
µV
µV
°C °C
µV
2 Honeywell • Sensing and Control