For product inquiries or support, visit www.honeywellaircoolers.com
Para consultas sobre productos o soporte técnico visite: www.honeywellaircoolers.com
Customer Support : 1-800-474-2147
Centro de servicios al cliente: 1-800-474-2147
Made in P.R.C.
Fabricado en China
1
QUICK START GUIDE
Fill with water and plug into a standard
power outlet.
Note: Please make sure the household power voltage
matches the product specifications.
2
3
Place near an open door or window.
Note : Evaporative air cooler requires cross ventilation.
Turn ON and enjoy the cooling breeze.
Note: Start with LOW speed and gradually increase
to higher speed for optimum cooling performance.
INDEX
Read all instructions carefully before setting up and operating the cooler, and
please keep this instruction manual for future reference. This manual is designed to
provide you with important information needed to setup, operate, maintain, and
troubleshoot your cooler. Failure to follow these instructions may damage and/or
impair its operation and void the warranty.
SECTION
1. THANK YOU ..................................................................
2. USER TIPS .................................................................
Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For
optimum cooling from your cooler, fill the water tank to maximum level.
Place the cooler in front of an open door or window. Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler.
Following these guideline will ensure your cooler will work as effectively as possible.
Not an Air Conditioner (Important - Please Read!)
The evaporative air cooler is not an air conditioner as it does not use a compressor or
refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner.
2
USER TIPS
Energy Efficient, No Compressor
Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low.
Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the
Honeycomb Cooling Media. Water pumped from the tank pours over the Honeycomb Cooling
Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the
heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room.
This no-compressor system cools naturally, efficiently and inexpensively.
Honeycomb Cooling Media
Cool and
humid air
Water
Evaporative Air Cooling Mechanism
Pump
Warm and
dry air
3
USER TIPS
The recommended maximum relative humidity level is 60% or
less, which allows a noticeable temperature decrease. The
temperature decrease will be greater in drier climates
because higher evaporation occurs when the humidity is low.
The evaporative air cooler should not be used in enclosed
spaces. It must be kept level and there must be water in the
water tank. The room should have doors and windows
opened to allow free air flow. The evaporative air cooler works
best when placed near an open window, so that outside air is
drawn into the evaporative air cooler, the air circulates in the
room, then exits via the door. The maximum cooling effect is
felt when a person is in the flow of air coming out of the
evaporative air cooler.
The evaporative air cooler can also be used to humidify dry
air during cool weather. To be used for humidification the
windows and doors should be closed to allow the humidified
air to accumulate.
NOTE
When the product is used for the first time the Honeycomb Cooling Media will have an odor
which will dissipate in a few hours of initial use.
Room with open windows & door
(RECOMMENDED)
Room with closed windows & door
(NOT-RECOMMENDED)
4
SAFETY
READ AND SAVETHESE INSTRUCTIONS:
When using electrical appliances, basic safety precautions should always be followed:
Your cooler runs on 120 Volt AC, 60 Hz current. Check the
•
household voltage to ensure it matches the appliance's rate
specification.
•
Before operating the product remove it from its packaging
and check that it is in good condition.
DO NOT operate any product with a damaged cord or plug.
•
We recommend not using an extension cord with this appliance.
DO NOT run power cord under carpeting, or cover it with rugs
•
or runners. Keep the cord away from areas where it may be
tripped over.
Always unplug the product before refilling the water tank.
•
•
Always unplug the appliance from the power source before
cleaning, servicing or relocating the unit.
Remove the power cord from the electrical receptacle by
•
grasping and pulling on the power cord plug-end only, never
pull the cord.
DO NOT use the product in areas where gasoline, paint or
•
other flammable goods and objects are stored.
When using the COOL setting, check the water tank to
•
ensure that it is full. Operation of this cooler on the COOL
setting with an empty tank may result in damage to the water
pump.
120V - 60 Hz
Shock Hazard
Water Level Indicator
5
•
DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty.
•
DO NOT cover the air inlet or outlet on the appliance as this
may cause motor damage.
DO NOT insert or allow objects to enter any ventilation or
•
exhaust opening as this may damage the product and could
cause an electrical shock or fire.
DO NOT operate with the Honeycomb Cooling Media removed
•
as this will overload and damage the motor.
•
DO NOT leave the operating appliance unattended for any
extended period of time.
•
DO NOT let children play with this appliance, packaging or
plastic bags.
If the unit is damaged or it malfunctions, do not continue to
•
operate it. Refer to the troubleshooting section and seek
professional advice.
Place the unit on a level floor.
•
This product is not intended for use in wet or damp locations.
•
•
DO NOT use in bathrooms. Never locate the product where
it may fall into a bathtub or other water container.
•
Store in a dry area when not in use.
This appliance is not intended for use by persons (including
•
children or elderly) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
•
Always grip the side handles to move the cooler.
•
Warning: To reduce the risk of fire or electric shock, do not
use this appliance with any solid space speed control device.
SAFETY
Floor Level
6
PARTS DESCRIPTION
9
12
11
10
1
2
8
3
4
6
5
1 Remote Control
2 Control Panel
3 Remote Control Receptor
4 Vertical Louvers
(Automatic Movement with SWING)
5 Drain Plug
6 Water Level Indicator
ACCESSORIES:
Remote Control (1pc Li batteries CR2032 included)
7
7 Casters
8 Side Handle
9 Back Grill
10 Water Fill Door
11 Power Cord & Plug
12 Rear Grill Removal Screw
7
Control Panel
USE & OPERATION
Lo Med Hi
SWINGSLEEPTIMERSPEEDCOOLPOWER
8
USE & OPERATION
Function Buttons
POWER
Press the button to turn the unit on. The cooler will start
POWER
SPEED
COOL
automatically at medium speed. After a few seconds the speed will
switch to low. To turn the unit off, press the button again.
SPEED
Press the button repeatedly and the speed will change. The
indicator light will show the selected speed. High (Hi), Medium (Med)
& Low (Lo).
COOL
To begin cooling the desired area, press the button. The indicator
light will come on and the water pump will operate. You will feel the cooler
air after the honeycomb media is completely wet.
9
Function Buttons
SWING
Press the button. The indicator light will come on and the vertical
SWING
TIMER
SLEEP
louvers will begin to move from right to left automatically. Horizontal louvers
movement is manual.
TIMER
Press the button until the indicator light comes on to your desired
timer. Once the set time has passed, the unit will automatically shut off. The
Timer function allows you to program the unit for up to 7.5 hours of use.
SLEEP
The SLEEP mode is for comfort during the night. When the mode
is selected, the airflow will randomly vary between High, Medium and Low.
USE & OPERATION
10
USE & OPERATION
Remote Control
Power : On/ Off
Cool : Controls cooling or fan option
Speed : Low / Medium / High
Timer : Controls timer function for automatic shut off
Swing : Controls the motion of the vertical louvers
Sleep : Turns on the sleep mode
POWER
COOL
SPEED
TIMER
SWING
Remote Control (1pc Li batteries CR2032 included)
NOTE
Open the battery compartment at the back of the remote control and insert 1pc Li
•
batteries CR2032. Care must be taken to insert the batteries according to the
correct polarity (+ / –) markings shown inside the battery compartment.
Always point the remote control signal transmitter towards the unit when operating.
•
Make sure that the signal path is not obstructed.
•
Remove the batteries if the unit is not going to be used for an extended period of time.
•
Do not drop the remote control.
•
Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.
•
Do not mix old and new batteries.
•
Exhausted batteries are to be removed from the product.
•
SLEEP
11
Loading...
+ 29 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.