Honeywell CS071AE User Manual

Portable Evaporative Air Cooler

for Indoor Use

Enfriador de Aire Portátil por Evaporación

Para Uso En El Interior

OWNER’S MANUAL

Read and save these instructions before use

Manual del Usuario

Leer y guardar estas instrucciones antes de usar

Model: CS071AE

Modelo: CS071AE

Power rating: 50 Watts

Voltage rating: 120 Volt AC, 60Hz

Potencia: 50 Watt

Voltage: 120 Volt AC, 60Hz

For product inquiries or support, visit www.honeywellaircoolers.com Para consultas sobre productos o soporte técnico visite: www.honeywellaircoolers.com

Customer Support : 1-800-474-2147

Made in P.R.C.

Centro de servicios al cliente: 1-800-474-2147

Fabricado en China

1

2

3

QUICK START GUIDE

Fill with water and plug into a standard power outlet.

Note: Please make sure the household power voltage matches the product specifications.

Place near an open door or window.

Note : Evaporative air cooler requires cross ventilation.

Turn ON and enjoy the cooling breeze.

Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.

INDEX

Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.

SECTION

PAGE

1.

THANK YOU ..................................................................

........................................ 2

2.

USER TIPS ............................................................................................................

3

3.

SAFETY .................................................................................................................

5

4.

PARTS DESCRIPTION ..........................................................................................

7

5.

USE & OPERATION ...............................................................................................

8

 

Control Panel ...........................................................................................................

8

 

Function Buttons .......................................................................................................

9

 

Remote Control .........................................................................................................

11

 

Filling with Water ......................................................................................................

12

6.

CLEANING & MAINTENANCE ...............................................................................

13

7.

TROUBLESHOOTING GUIDE ................................................................................

15

8.

TECHNICAL SPECIFICATIONS ................................................................. ............

17

9.

ELECTRICAL WIRING DIAGRAM ..........................................................................

17

10.SERVICE AND WARRANTY ...................................................................................

18

1

THANK YOU

Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level.

Cooler Location – Indoors (Important - Please Read!)

Place the cooler in front of an open door or window. Ensure that there is adequate cross - ventilation in the room by leaving a door or window open opposite the cooler.

Following these guideline will ensure your cooler will work as effectively as possible.

Not an Air Conditioner (Important - Please Read!)

The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner.

2

USER TIPS

Energy Efficient, No Compressor

Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling Media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively.

Honeycomb Cooling Media

 

 

Cool and

Warm

and

humid

air

 

dry air

 

 

 

Pump

Water

Evaporative Air Cooling Mechanism

3

USER TIPS

The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low.

The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow. The evaporative air cooler works best when placed near an open window, so that outside air is drawn into the evaporative air cooler, the air circulates in the room, then exits via the door. The maximum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler.

The evaporative air cooler can also be used to humidify dry air during cool weather. To be used for humidification the windows and doors should be closed to allow the humidified air to accumulate.

NOTE

Room with open windows & door

(RECOMMENDED)

Room with closed windows & door (NOT-RECOMMENDED)

When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours of initial use.

4

SAFETY

READ AND SAVE THESE INSTRUCTIONS:

When using electrical appliances, basic safety precautions should always be followed:

Your cooler runs on 120 Volt AC, 60 Hz current. Check the household voltage to ensure it matches the appliance's rate specification.

Before operating the product remove it from its packaging and check that it is in good condition.

DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance.

DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over.

Always unplug the product before refilling the water tank.

Always unplug the appliance from the power source before cleaning, servicing or relocating the unit.

Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, never pull the cord.

DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are stored.

When using the COOL setting, check the water tank to ensure that it is full. Operation of this cooler on the COOL setting with an empty tank may result in damage to the water pump.

120V - 60 Hz

Shock Hazard

Water Level Indicator

5

DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty.

DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage.

DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire.

DO NOT operate with the Honeycomb Cooling Media removed as this will overload and damage the motor.

DO NOT leave the operating appliance unattended for any extended period of time.

DO NOT let children play with this appliance, packaging or plastic bags.

If the unit is damaged or it malfunctions, do not continue to operate it. Refer to the troubleshooting section and seek professional advice.

Place the unit on a level floor.

This product is not intended for use in wet or damp locations.

DO NOT use in bathrooms. Never locate the product where it may fall into a bathtub or other water container.

Store in a dry area when not in use.

This appliance is not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Always grip the side handles to move the cooler.

Warning: To reduce the risk of fire or electric shock, do not use this appliance with any solid space speed control device.

SAFETY

Floor Level

6

Honeywell CS071AE User Manual

PARTS DESCRIPTION

 

 

1

 

 

2

 

8

3

 

4

 

 

 

9

 

 

10

 

 

12

 

 

11

6

 

 

 

5

7

 

 

1

Remote Control

7 Casters

2

Control Panel

8 Side Handle

3

Remote Control Receptor

9 Back Grill

4

Vertical Louvers

10 Water Fill Door

 

(Automatic Movement with SWING)

11 Power Cord & Plug

5

Drain Plug

12 Rear Grill Removal Screw

6

Water Level Indicator

 

ACCESSORIES:

Remote Control (1pc Li batteries CR2032 included)

7

USE & OPERATION

Control Panel

Lo Med Hi

SLEEP

SWING

TIMER

SPEED

COOL

POWER

8

USE & OPERATION

Function Buttons

POWER

SPEED

COOL

POWER

Press the button to turn the unit on. The cooler will start automatically at medium speed. After a few seconds the speed will switch to low. To turn the unit off, press the button again.

SPEED

Press the button repeatedly and the speed will change. The indicator light will show the selected speed. High (Hi), Medium (Med) & Low (Lo).

COOL

To begin cooling the desired area, press the button. The indicator light will come on and the water pump will operate. You will feel the cooler air after the honeycomb media is completely wet.

9

USE & OPERATION

Function Buttons

SWING

TIMER

SLEEP

SWING

Press the button. The indicator light will come on and the vertical louvers will begin to move from right to left automatically. Horizontal louvers movement is manual.

TIMER

Press the button until the indicator light comes on to your desired timer. Once the set time has passed, the unit will automatically shut off. The Timer function allows you to program the unit for up to 7.5 hours of use.

SLEEP

The SLEEP mode is for comfort during the night. When the mode is selected, the airflow will randomly vary between High, Medium and Low.

10

USE & OPERATION

Remote Control

Power

: On/ Off

Cool

: Controls cooling or fan option

Speed

: Low / Medium / High

Timer

: Controls timer function for automatic shut off

Swing

: Controls the motion of the vertical louvers

Sleep

: Turns on the sleep mode

Remote Control (1pc Li batteries CR2032 included)

NOTE

Open the battery compartment at the back of the remote control and insert 1pc Li batteries CR2032. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.

POWER

COOL

SPEED

TIMER

SWING

SLEEP

Always point the remote control signal transmitter towards the unit when operating.

Make sure that the signal path is not obstructed.

Remove the batteries if the unit is not going to be used for an extended period of time.

Do not drop the remote control.

Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries.

Do not mix old and new batteries.

Exhausted batteries are to be removed from the product.

11