BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of
Limited Warranty and Limitation Liability
two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer.
BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair or replacement of a defective product that is returned to
a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the purchase price actually paid by the
buyer for the Product.
This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use;
b) any product which in BW’s opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation,
handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved
parts on the product; or
The obligations set forth in this warranty are conditional on:
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable
recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be
returned to BW until receipt by the buyer of shipping instructions from BW; and
c) the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the
product is within the warranty period.
THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY
SPECIAL
, INDIRECT, INCIDENTAL, OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential
damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or
unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Email us at: info@gasmonitors.com
Visit BW Technologies by Honeywell’s website at:
www.gasmonitors.com
GasAlertMaxXT II
Introduction
The Quick Reference Guide provides basic information to oper-
ate the GasAlertMaxXT II gas detector. For complete operating
instructions, refer to the GasAlertMaxXT II Technical Reference Guide provided on the CD-ROM. The GasAlertMaxXT II gas
detector (“the detector”) is designed to warn of hazardous gas
levels above user-defined alarm setpoints.
The detector is a personal safety device. It is your responsibility
to respond properly to the alarm.
Note
The detector is shipped with English as the default
displayed language. Additional languages provided
are French, German, Spanish, and Portuguese. The
screens for the additional languages are displayed on
the detector and in the corresponding operator’s
manual.
Zeroing the Sensors
To zero the sensors, refer to steps #1-3 in Calibration on
page 9.
Safety Information - Read First
Use the detector only as specified in this operator’s manual and
the technical reference guide, otherwise the protection provided
by the detector may be impaired.
Read the following Cautions before using the detector.
Cautions
a
• Warning: Substitution of components may impair Intrinsic
Safety.
• Caution: For safety reasons, this equipment must be
operated and serviced by qualified personnel only. Read
and understand the technical reference guide completely
before operating or servicing.
• Charge the detector before first-time use. BW recommends
the detector be charged after every workday.
• Calibrate the detector before first-time use and then on a
regular schedule, depending on use and sensor exposure
to poisons and contaminants. The sensors must be
calibrated regularly and at least once every 180 days
(6 months).
1
GasAlertMaxXT II
Quick Reference Guide
• Calibrate only in a safe area that is free of hazardous gas in
an atmosphere of 20.9 % oxygen.
• The combustible sensor is factory calibrated to 50% LEL
methane. If monitoring a different combustible gas in the %
LEL range, calibrate the sensor using the appropriate gas.
• Only the combustible gas detection portion of this
instrument has been assessed for performance by CSA
International.
• Protect the combustible sensor from exposure to lead
compounds, silicones, and chlorinated hydrocarbons.
Although certain organic vapors (such as leaded gasoline
and halogenated hydrocarbons) may temporarily inhibit
sensor performance, in most cases the sensor will recover
after calibration.
• BW recommends that the combustible sensor be checked
with a known concentration of calibration gas after any
exposure to contaminants/poisons such as sulfur
compounds, silicon vapors, halogenated compounds, etc.
• BW recommends to bump test the sensors before each
day’s use to confirm their ability to respond to gas by
exposing the detector to a gas concentration that exceeds
the alarm setpoints. Manually verify that the audible and
visual alarms are activated. Calibrate if the readings are not
within the specified limits.
• Caution: High off-scale LEL readings may indicate an
explosive concentration.
• Any rapid up scaling reading followed by a declining or
erratic reading may indicate a gas concentration beyond
upper scale limit, which can be hazardous.
2
• For use only in potentially explosive atmospheres where
oxygen concentrations do not exceed 20.9% (v/v).
• Extended exposure of the GasAlertMax XT II to certain
concentrations of combustible gases and air may stress the
detector element that can seriously affect its performance. If
an alarm occurs due to a high concentration of combustible
gases, recalibration should be performed, or if needed, the
sensor replaced.
• The BW pump (XT-RPUMP-K1) is certified for use with the
GasAlertMax XT II only.
Warning: The lithium battery (MX-BAT01) may present a risk
•
of fire or chemical burn hazard if misused. Do not
disassemble, heat above 212°F (100°C), or incinerate.
Warning: Do not use any other lithium batteries with the
•
GasAlertMax XT II detector. Use of any other cell can cause
fire and/or explosion. To order and replace the MX-BAT01
lithium battery, contact
• Warning: Lithium polymer cells exposed to heat at 266°F
(130°C) for 10 minutes can cause fire and/or explosion.
• Dispose of used lithium cells immediately. Do not
disassemble and do not dispose of in fire. Do not mix with
the solid waste stream. Spent batteries must be disposed
of by a qualified recycler or hazardous materials handler.
• Keep lithium cells away from children.
• Calibrations and bump tests can be performed using a
0.5 l/min. regulator or a demand flow regulator. If the demand
flow regulator is used, it must meet the following maximum
inlet pressure specifications:
• Disposable cylinders 0-3000 psig/70 bar
• Refillable cylinders 0-3000 psig/70 bar
BW Technologies by Honeywell.
• Products may contain materials that are regulated for
transportation under domestic and international dangerous goods regulations. Return product in compliance with
appropriate dangerous goods regulations. Contact freight
carrier for further instructions.
Informations sur la sécurité - À lire avant
toute chose
Respectez strictement les instructions d'emploi figurant dans ce
manuel d'utilisation ainsi que dans le guide technique, sinon, la
protection offerte par le détecteur pourrait être diminuée.
Lisez les Précautions suivantes avant d'utiliser le détecteur.
a Précautions
• Avertissement: Le remplacement d'un composant de
l'appareil peut altérer sa sécurité intrinsèque.
• Précaution: Pour des raisons de sécurité, cet appareil doit
être exclusivement utilisé et entretenu par du personnel
qualifié. Lisez attentivement le guide technique avant
• d'utiliser l'appareil ou d'en assurer l'entretien, et assurezvous d'en avoir bien compris les instructions.
• Chargez le détecteur avant sa première utilisation. BW
recommande de recharger le détecteur après chaque
journée d'utilisation.
• Étalonnez le détecteur avant sa première utilisation, puis de
manière régulière, en fonction de l'utilisation et de
l'exposition du capteur aux poisons et autres contaminants.
Les capteurs doivent être étalonnés régulièrement et au
moins une fois tous les 180 jours (6 mois).
• Veillez à effectuer l'étalonnage dans une zone sûre, exempte
Informations sur la sécurité - À lire avant toute chose
GasAlertMaxXT II
de gaz dangereux, dans une atmosphère contenant 20,9 %
d'oxygène.
• Le capteur de gaz combustible est étalonné en usine au
méthane à une concentration de 50% LIE. Si la surveillance
porte sur un autre gaz combustible dans la plage de %LIE,
étalonnez le capteur en utilisant le gaz approprié.
• Sur cet appareil, seule la détection de gaz combustible a fait
l'objet d'une évaluation des performances par CSA
International.
• Protégez le capteur de gaz combustible des expositions aux
composés de plomb, aux silicones et aux hydrocarbures
chlorés. Bien que certaines vapeurs organiques (comme
l'essence au plomb ou les hydrocarbures halogénés)
puissent neutraliser provisoirement les performances du
capteur, dans la plupart des cas, le capteur retrouvera son
fonctionnement normal après étalonnage.
• Si le capteur de gaz combustible a été exposé à des
contaminants/poisons (composés de soufre, vapeurs de
silicium, produits halogénés, etc.), il est conseillé de vérifier
son bon fonctionnement en le mettant en présence d'une
concentration connue d'un gaz.
• BW recommande d'effectuer un " test fonctionnel " des
capteurs, avant chaque utilisation quotidienne, afin de
vérifier qu'ils réagissent bien au gaz, notamment lorsque le
détecteur est exposé à une concentration de gaz qui
dépasse les seuils d'alarme. Vérifiez manuellement que les
alarmes sonore et visuelle sont activées. Étalonnez
l'appareil si les lectures sont en dehors des limites
spécifiées.
• Précaution: Des lectures élevées hors échelle peuvent
indiquer la présence d'une concentration explosive.
3
GasAlertMaxXT II
Quick Reference Guide
• Une lecture qui augmente rapidement, puis qui baisse, ou
une lecture fantaisiste peuvent être représentatives d'une
concentration de gaz excédant la limite d'échelle supérieure
et risquant donc d'être dangereuse.
• Cet appareil est uniquement destiné aux atmosphères
potentiellement explosives où la concentration d'oxygène
ne dépasse pas 20,9 % (v/v).
• L'exposition prolongée du GasAlertMax XT II à certaines
concentrations de gaz combustible et d'air peut fortement
éprouver l'élément du détecteur et nuire gravement à ses
performances. En cas d'alarme, suite à une forte
concentration de gaz combustible, il convient d'effectuer un
réétalonnage, voire de remplacer le capteur si nécessaire.
• La pompe BW (XT-RPUMP-K1) est certifiée pour une
utilisation avec le GasAlertMax XT II uniquement.
Avertissement: La batterie au lithium (MX-BAT01) peut
•
présenter un risque d'incendie ou de brûlure chimique en
cas de mauvaise utilisation. Elle ne doit jamais être
démontée, incinérée ni chauffée au-delà de 100 °C.
Avertissement: N'utilisez jamais d'autres piles au lithium
•
avec le détecteur GasAlertMax XT II, au risque de provoquer
un incendie et/ou une explosion. Pour commander une
batterie au lithium MX-BAT01 de rechange, contactez BW
Technologies by Honeywell.
Avertissement: Les piles au lithium polymère exposées
•
à une température supérieure à 130 °C pendant plus de
10 minutes peuvent provoquer un incendie et/ou une
explosion.
• Mettez immédiatement au rebut les piles au lithium usagées.
Ne les démontez jamais et ne les jetez pas au feu. Ne les
4
mélangez pas aux autres déchets solides. Les piles usagées
doivent être éliminées par un centre de recyclage agréé ou
un centre de traitement des matières dangereuses.
• Gardez les piles au lithium hors de portée des enfants.
•
de gaz d'étalonnage de haute qualité et de bouteilles
répondant aux normes nationales. Les gaz d'étalonnage
doivent correspondre à la précision du détecteur.
• Les tests fonctionnels et les étalonnages peuvent être
effectués en utilisant un régulateur 0,5 l/min. ou un
régulateur de débit à la demande. Si vous utilisez le régulateur de débit à la demande, ce dernier doit répondre aux
spécifications de pression d'entrée maximale suivantes :
• Bouteilles jetables 0-3 000 psig/70 bar
• Bouteilles rechargeables 0-3 000 psig/70 bar
• Les produits peuvent contenir des matériaux qui sont
réglementés pour le transport en vertu des règlements
nationaux et internationaux de marchandises dangereuses.
Retourner le produit conformément à la réglementation sur
les marchandises dangereuses appropriées. Contactez
transporteur pour plus d'instructions.
Parts of the GasAlertMaxXT II
Parts of the GasAlertMaxXT II
GasAlertMaxXT II
ItemDescription
1
2
3
4
5
6
7
8
9
10
Visual alarm indicators (LEDs)
Pump quick connector
Pump filter and moisture filter
Pushbutton
Alligator clip
Charging connector and IR interface
Diffusion cover locking screw (1)
Diffusion cover
Audible alarm
Liquid crystal display (LCD)
5