Honeywell Boiler Trim Kit with SuperVent Catalog Page

Honeywell Boiler Trim Kit with SuperVent Catalog Page

Residential Expansion Tanks

Boiler Trim Kit with SuperVent

 

 

 

 

 

Honeywell TK Series Combo Boiler Trim kits are a quick and

 

 

 

 

 

convenient way to purchase the key “boiler trim” used by installers

 

 

 

 

 

when performing a boiler change out. All Combo Trim Kits with

 

 

 

 

 

SuperVent include expansion tank and SuperVent high

 

 

 

 

 

performance air eliminator; selected models also include FM911

 

 

 

 

 

combination boiler fill valve / backflow preventer and/or service

 

 

 

 

 

check valves for in-line servicing of the expansion tank.

 

 

 

 

 

Maximum Operating Temperature: 240 F (115 C)

 

 

 

 

 

 

Maximum Operating Pressure: 100 psi (689 kPA)

 

 

 

 

 

 

Diameter: 11 in. (279 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceptance

 

 

 

 

 

 

 

Connection Size

 

Height

 

 

Volume

Volume

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Number

 

(inch)

Connection Type

inch

mm

 

gal

L

gal

L

 

lb

 

 

kg

Includes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK30PV100FM

 

SuperVent: 1 in.

SuperVent: Female NPT

15 1/2 in.

394 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

16 lb

 

7.3 kg

TK300-30,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV100, SCV-050,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK30PV100FMNC/U

 

SuperVent: 1 in.

SuperVent: Female NPT

15 1/2 in.

394 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

16 lb

 

7.3 kg

TK300-30,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV100, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK30PV100SFM/U

 

SuperVent: 1 in.

SuperVent: Sweat

15 1/2 in.

394 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

16 lb

 

7.3 kg

TK300-30,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV100S, SCV-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

050, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK30PV125FM/U

 

SuperVent: 1 1/4 in.

SuperVent: Female NPT

15 1/2 in.

394 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

16.8 lb

 

7.6 kg

TK300-30,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV125, SCV-050,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK30PV125SFM/U

 

SuperVent: 1 1/4 in.

SuperVent: Sweat

15 1/2 in.

394 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

16.8 lb

 

7.6 kg

TK300-30,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV125S, SCV-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

050, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK60PV100SFMNC/U

SuperVent: 1 1/4 in.

SuperVent: Female NPT

23 in.

584 mm

 

4.4 gal

16.7 L

2.5 gal

9.5 L

15.3 lb

 

6.9 kg

TK300-60,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PV100S, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK60PV125FMNC/U

 

SuperVent: 1 1/4 in.

SuperVent: Female NPT

23 in.

584 mm

 

7.6 gal

28.8 L

2.5 gal

9.5 L

17.5 lb

 

7.95

TK300-60,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

PV125, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK60PV125SFMNC/U

SuperVent: 1 1/4 in.

SuperVent: Sweat

23 in.

584 mm

 

7.6 gal

28.8 L

2.5 gal

9.5 L

17.5 lb

 

7.95

TK300-60,

 

 

Tank: 1/2 in.

Tank: Male NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

PV125S, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler Trim Kit with Air Purger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Honeywell TK Series Boiler Trim kits are a quick and convenient

 

 

 

 

 

way to purchase the key “boiler trim” used by installers when

 

 

 

 

 

performing a boiler change out. All Trim Kits with Purgers include

 

 

 

 

 

expansion tank, air purger and air vent; selected models also

 

 

 

 

 

include FM911 combination boiler fill valve / backflow preventer

 

 

 

 

 

and/or service check valves for in-line servicing of the expansion

 

 

 

 

 

tank and air vent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Operating Temperature: 240 F (115 C)

 

 

 

 

 

 

Maximum Operating Pressure: 100 psi (689 kPA)

 

 

 

 

 

 

Diameter: 11 in. (279 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Height: 15 1/2 in. (394 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceptance

 

 

 

 

 

 

 

 

 

 

Connection Size

 

 

Volume

 

Volume

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Number

(inch)

Connection Type

 

gal

L

gal

L

 

lb

 

kg

 

Includes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TK300-30A-1/U

Tank: 1/2 in.;

Tank: Male NPT;

 

4.4 gal

16.7 L

2.5 gal

9.5 L

 

13 lb

 

5.9 kg

TK300-30, AP400, FV180,

 

Air Purger: 1 in.

Air Purger: Female NPT

 

 

 

 

 

 

 

 

 

 

 

SCV-0125, SCV-050

 

 

 

 

 

 

 

 

 

 

 

 

TK300-30A-1FM/U

Tank: 1/2 in.;

Tank: Male NPT;

 

4.4 gal

16.7 L

2.5 gal

9.5 L

 

16.6 b

7.5 kg

TK300-30, AP400, FV180,

 

Air Purger: 1 in.

Air Purger: Female NPT

 

 

 

 

 

 

 

 

 

 

 

SCV-0125, SCV-050, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

TK300-30A-2/U

Tank: 1/2 in.

Tank: Male NPT;

 

4.4 gal

16.7 L

2.5 gal

9.5 L

 

13 lb

 

5.9 kg

TK300-30, AP401, FV180,

 

Air Purger: 1 1/4 in.

Air Purger: Female NPT

 

 

 

 

 

 

 

 

 

 

 

SCV-0125, SCV-050

 

 

 

 

 

 

 

 

 

 

 

 

TK300-30A-2FM/U

Tank: 1/2 in.

Tank: Male NPT;

 

4.4 gal

16.7 L

2.5 gal

9.5 L

 

16.6 b

7.5 kg

TK300-30, AP401, FV180,

 

Air Purger: 1 1/4 in.

Air Purger: Female NPT

 

 

 

 

 

 

 

 

 

 

 

SCV-0125, SCV-050, FM911

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>Hydronic

<![if ! IE]>

<![endif]>Controls

70-6910

 

 

 

231

 

 

Loading...