Transformers
|
Dimensions, Approximate |
Electrical Ratings |
|
|
|
|
|
|||||
|
|
|
|
|
(Primary |
(Secondary |
|
|
NEMA |
|
||
Product Number |
(inch) |
|
(mm) |
Voltage) |
Voltage) |
(Output) |
Mounting |
|
Rating |
Includes |
||
AT150A1007/U |
1 11/16 in. high x |
43 mm high x |
120 |
Vac, |
27.5 V.O.C. |
24 Vac at |
Foot mounted, plate mounted on 2x4 in. |
No |
Metal end |
|||
|
3 |
3/16 in. wide x |
81 mm wide x |
208 |
Vac, |
|
50 VA |
or 4x4 in. outlet box, clamp mounted |
|
bells |
||
|
1 |
3/4 in. deep |
75 mm deep |
240 |
Vac |
|
|
using outlet box knockout, or panel |
|
|
||
|
|
|
|
|
|
|
|
|
mounted |
|
|
|
AT150B1146/U |
1 11/16 in. high x |
43 mm high x |
120 |
Vac, |
— |
24 Vac at |
Foot-mounted |
|
No |
— |
||
|
3 |
1/2 in. wide x |
89 mm wide x |
208 |
Vac, |
|
50 VA |
|
|
|
|
|
|
1 |
3/4 in. deep |
75 mm deep |
240 |
Vac |
|
|
|
|
|
|
|
AT150B1252/U |
1 11/16 in. high x |
43 mm high x |
277 |
Vac |
27.5 V.O.C. |
24 Vac at |
Foot-mounted |
|
No |
Plastic |
||
|
3 |
1/2 in. wide x |
89 mm wide x |
|
|
|
50 VA |
|
|
|
end caps |
|
|
1 |
3/4 in. deep |
75 mm deep |
|
|
|
|
|
|
|
|
|
AT175A1008/U |
3 |
3/16 in. high x |
81 mm high x |
120 |
Vac, |
27.5 V.O.C. |
24 Vac at |
Foot mounted, plate mounted on 2x4 in. |
NEMA |
Metal end |
||
|
2 |
3/8 in. wide x |
60 mm wide x |
208 |
Vac, |
|
75 VA |
or 4x4 in. outlet box, clamp mounted |
type E |
bells |
||
|
3 |
5/8 deep |
92 mm deep |
240 |
Vac |
|
|
using outlet box knockout, or panel |
|
|
||
|
|
|
|
|
|
|
|
|
mounted |
|
|
|
Dimensions in inches (millimeters) |
|
|
|
|
|
|
|
|
|
|||
PLATE OR OUTLET BOX |
PLATE MOUNTED AT THE |
|
FOOT MOUNTED |
|
|
MOUNTING PLATE |
|
|
||||
|
|
|
|
|
|
|||||||
MOUNTED AT CLAMP |
|
LAMINATIONS (3/4 ABOVE |
|
3-1/16 (78) |
|
|
3-3/8 (86) |
|
|
|||
ON END BELL (ALL |
|
|
PLATE MOUNTING) |
|
|
|
|
1/8 (3) |
|
|||
ABOVE PLATE MOUNTING) |
|
|
|
|
|
|
|
|
|
|
||
2-15/16 (76) |
|
|
1-1/16 |
2 (51) |
|
|
|
|
|
|
|
|
|
|
|
(27) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3-7/32 |
|
|
|
|
|
|
|
|
|
|
|
|
82 |
1/8 |
|
1/4 |
|
|
|
|
|
|
|
|
|
2-1/4 |
|
(6) |
|
|
|
|
|
|
|
|
|
|
(57) |
(3) |
|
4-3/16 |
|
|
|
|
|
|
|
|
|
|
|
(106) |
||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
2-3/8 |
|
|
|
|
|
|
|
|
|
|
|
|
(60) 2 |
|
3-3/8 |
|
|
|
|
|
|
|
|
D |
|
(51) |
|
(86) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1-3/4 |
|
|
|
|
|
|
|
|
|
|
|
|
(44) |
|
|
|
|
|
|
|
|
|
|
|
|
2-3/8 |
5/16 (8) |
3 -1/4 (83) |
|
|
|
|
|
|
|
|
|
|
(60) |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M17509A |
|
AT140 General Purpose Transformer for Hydronic Heating Controls
Provide power to 24 Vac circuits in heating/cooling control systems. Intended for use in systems with predictable, uniform loads. Can be used in any application that does not exceed the listed ratings.
• Color-coded leadwires for primary connections and screw terminals for secondary connections, fixed 1/4 inch (6 mm) male quickconnects or color-coded leadwires for both primary and secondary, are standard.
• Meet NEC Class 2 requirements.
• Meet Underwriters Laboratories Inc. Standard UL 1585 and are identified. Class 2 not wet, Class 3 wet.
<![endif]>Residential
<![if ! IE]><![endif]>Controls Combustion
Temperature Rating: -20 F to +105 F (-29 C to +41 C)
Frequency: 60 Hz
Electrical Connections (main):
Primary: 9 in. leadwires (229 mm leadwires) Secondary: (2) screw terminals
Approvals
Canadian Standards Association: CSA Certified: A & B models. Underwriters Laboratories, Inc: UL Listed: A,C,F models. File #
E14881
|
|
|
|
|
|
|
|
|
|
Dimensions, Approximate |
Electrical Ratings |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
(Primary |
(Secondary |
|
|
|
Product Number |
(inch) |
(mm) |
Voltage) |
Voltage) |
(Output) |
Mounting |
||
|
|
|
|
|
|
|
|
|
AT140A1034/U |
3 3/16 in. high x |
81 mm high x |
120 Vac |
27 V.O.C. |
24 |
Vac at |
Foot mounted, plate mounted on 2x4 in. or 4x4 in. outlet box, |
|
|
2 |
3/8 in. wide x |
60 mm wide x |
|
|
20 |
VA |
clamp mounted using outlet box knockout, or panel mounted |
|
3 |
1/8 in. deep |
79 mm deep |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
70-6910 |
|
|
|
159 |
|
|