Register your product online by visiting:
http://www.raesystems.com/support/product-registration
By registering your product, you can:
Receive notification of product upgrades or enhancements
Be alerted to Training classes in your area
Take advantage of RAE Systems special offers and promotions
23 RAE Systems by Honeywell Contacts ................................ ................................ ...................... 123
5
AreaRAE Plus & AreaRAE Pro User’s Guide
WARNINGS
Read Before Operating
This manual must be carefully read by all individuals who have or will have the responsibility of using,
maintaining, or servicing this product. The product will perform as designed only if it is used, maintained,
and serviced in accordance with the manufacturer’s instructions.
CAUTION!
Never operate the monitor when the cover is removed. Remove the monitor rear cover or battery only in
an area known to be non-hazardous.
ANY RAPID UP-SCALE READING FOLLOWED BY A DECLINING OR ERRATIC READING
MAY INDICATE A GAS CONCENTRATION BEYOND UPPER SCALE LIMIT, WHICH MAY
BE HAZARDOUS.
TOUTE LECTURE RAPIDE ET POSITIVE, SUIVIE D’UNE BAISSE SUBITE OU ERRATIQUE
DE LA VALEUR, PEUT INDIQUER UNE CONCENTRATION DE GAZ HORS GAMME DE
DÉTECTION QUI PEUT ÊTRE DANGEREUSE
ONLY THE COMBUSTIBLE GAS DETECTION PORTION OF THIS INSTRUMENT HAS
BEEN ASSESSED FOR PERFORMANCE.
UNIQUEMENT, LA PORTION POUR DÉTECTER LES GAZ COMBUSTIBLES DE CET
INSTRUMENT A ÉTÉ ÉVALUÉE.
CAUTION: BEFORE EACH DAY’S USAGE, SENSITIVITY OF THE LEL SENSOR MUST BE
TESTED ON A KNOWN CONCENTRATION OF METHANE GAS EQUIVALENT TO 20 TO 50%
OF FULL-SCALE CONCENTRATION. ACCURACY MUST BE WITHIN 0 AND +20% OF
ACTUAL. ACCURACY MAY BE CORRECTED BY CALIBRATION PROCEDURE.
ATTENTION: AVANT CHAQUE UTILISATION JOURNALIERE, VERIFIER LA SENSIBILITE
DU CAPTEUR DE LIE AVEC UNE CONCENTRATION CONNUE DE METHANE EQUIVALENTE
DE 20 A 50% DE LA PLEINE ECHELLE. LA PRECISION DOIT ETRE COMPRISE ENTRE 0 ET
20% DE LA VALEUR VRAIE ET PEUT ETRE CORRIGEE PAR UNE PROCEDURE
D’ETALONNAGE.
CAUTION: HIGH OFF-SCALE READINGS MAY INDICATE AN EXPLOSIVE
CONCENTRATION.
ATTENTION: DES LECTURES HAUTES ET HORS D’ECHELLE PEUVENT INDIQUER DES
CONCENTRATIONS DE GAZ INFLAMMABLES
CAUTION: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
Note: Users are recommended to refer to ISA-RP12.13, Part II-1987 for general information on
installation, operation, and maintenance of combustible gas detection instruments.
The AreaRAE2 multi-gas detector must be calibrated if it does not pass a bump test, or at least once every
180 days, depending on use and sensor exposure to poisons and contaminants.
6
AreaRAE Plus & AreaRAE Pro User’s Guide
IECEx XXX15.XXXX
Ex ic nA [ic] IIC T4 Gc
XXX 15 ATEX XXXX
II 3G Ex ic nA [ic] IIC T4 Gc
Cl.I Dv 2, Grps A,B,C,D
T-Code T4.
C22.2 No.152-M1984
ANSI/ISA-12.13.01-2013
CAUTION!
TheAreaRAE, PGM-65XX shall only be charged using a charger specifically supplied for use
with the unit with a mximum output voltage of 17V.
Use of non-RAE Systems components will void the warranty and can compromise the safe
performance of this product.
MARKING
The PGM-65XX is certified according to the IECEx scheme, ATEX and CSA for US and
Canada under the non-sparking safety method of protection.
The PGM-65XX is marked with the following information:
RAE SYSTEMS
3775 N. 1st. St., San Jose
CA 95134, USA
Type PGM-65XX.
Serial No/barcode: XXXX-XXXX-XX
CAUTION: READ AND UNDERSTAND INSTRUCTION MANUAL BEFORE OPERATING OR SERVICING
ATTENTION: LIRE ET COMPRENDRE MANUEL D’INSTRUCTIONS AVANT D’UTILISER OU SERVICE.
FCC Part 15 Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
7
AreaRAE Plus & AreaRAE Pro User’s Guide
Caution:
This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired
operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following
measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and
maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio
interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec
une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut
choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following
two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of
the device.
8
AreaRAE Plus & AreaRAE Pro User’s Guide
MESH
Freewave 900
WIFI
Freewave 2400
Gain of antenna:
3.0dBi
Gain of antenna:
2.0dBi
Gain of antenna:
4.9dBi
Gain of antenna:
2.5dBi Max
Type of
antenna:Omnidirectional
Type of
antenna:Omnidirectional
Type of
antenna:Omnidirectional
Type of
antenna:Omnidirectional
Impedance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
MESH
Freewave 900
WIFI
Freewave 2400
Gain d'antenne:
3.0dBi
Gain d'antenne:
2.0dBi
Gain d'antenne:
4.9dBi
Gain d'antenne:
2.5dBi Max
Type
d'antenne:Omnidirectional
Type
d'antenne:Omnidirectional
Type
d'antenne:Omnidirectional
Type
d'antenne:Omnidirectional
Impedance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
impédance
d'antenne: 50ohm
MPE Reminding
To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation.
To ensure compliance, operation at closer than this distance is not recommended.
Les antennes installées doivent être situées de facon à ce que la population ne puisse
y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce
que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’
antenne.
La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d’au
moins 20 cm des personnes pendant son functionnement.
Only for detachable antennas:
This radio transmitter (identify the device by certification number, or model number if
Category II) has been approved by Industry Canada to operate with the antenna types
listed below with the maximum permissible gain and required antenna impedance for
each antenna type indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly prohibited for use
with this device.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou
son numéro de modèle s'il fait partie du matériel de catégorie I) a été approuvé par
Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et
ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne.
Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain
maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
9
AreaRAE Plus & AreaRAE Pro User’s Guide
Operation Area and Conditions
Hazardous Areas classified by Zones
PGM-65XX are intended to be used in hazardous areas classified zone 2 within the temperature range of
-20º C to +50º C, where gases of explosion groups IIA, IIB or IIC and T4 may be present.
Hazardous Areas classified by Divisions
PGM-65XX is intended to be used in hazardous areas classified for Class I Div. 2, within the
temperature range of -20º C to +50º C, where gases of explosion groups A, B, C or D and temperature
code T4 may be present.
INSTRUCTIONS FOR SAFE USE
WARNING: Read and understand instruction manual before operation or servicing.
AVERTISSEMENT: Lisez et comprenez le manual d’instructions avant d’utiliser ou d'effectuer
l'entretien.
WARNING: Substitution of components may impact safety.
AVERTISSEMENT: La substitution de composants peut compromettre la sécurité.
WARNING: To prevent ignition of a hazardous atmosphere, batteries must only be charged in an area
known to be non-hazardous area in the ambient temperature range 0° C ≤ T
approved charger.
AVERTISSEMENT:Afin de prevenir l’inflammation d’atmosphères dangereuse, ne charger le jeu de
batteries que dans des emplacement designés non dangereux a temperature ambiante 0°C ≤ T
Utilisez uniquement un chargeur approuvé.
WARNING: As a condition of certification, connection may not be made to the communication port
when the Gas Detector is in the hazardous location unless the area is known not to be hazardous.
AVERTISSEMENT: Comme condition de la certification, un connexion filaire ne peut pas être faite
via le port de communication lorsque le détecteur de gaz est dans la zone dangereuse à moins que la zone
soit connue pour ne pas être dangereuse.
WARNING: Li-Ion rechargeable battery: Only use approved battery pack: W01-3007-000.
AVERTISSEMENT: Batterie rechargeable Li-Ion: Utilisez uniquement des batteries approuvé: W01-
3007-000.
WARNING: For the battery cassette for primary batteries only use 5 new D size alkaline batteries
(Duracell MN1300). Do not mix old and new primary batteries or batteries from different manufacturers,
in the primary battery cassette.
AVERTISSEMENT: Pour la cassette des batteries primaires utilisent seulement 5 nouvelles piles
alcalines de type D (Duracell MN1300). Ne pas mélanger des piles primaires anciennes et nouvelles ou
de différents fabricants, dans la cassette de la batterie primaire.
Only use RAE Systems charger for PGM-65XX with a maximum output voltage of 17V.
≤ 40° C. Use only
amb
≤ 40°C
amb
10
AreaRAE Plus & AreaRAE Pro User’s Guide
Cover all ports when
they are not in use
USE IN HAZARDOUS AREAS
Equipment which is intended for use in explosive atmospheres and which has been assessed and certified
according to international regulations may be used only under specified conditions. The components may
not be modified in any way.
The appropriate regulations for service and repair must be properly observed during such activities.
PGM-65XX contains a connector for mounting of a wind sensor – RAEMet. This connector has a set of
entity parameters that mach the input entity parameters of RAEMet:
Uo: 5.2V; Po: 0.788W; Lo: 198μH; Co: 1000μF.
The solid-state relay connection is supplied with following entity parameters, that must be complied with
for external connections: Ui: 24V; Ii: 250mA.
Keep all ports covered when they are not in use. This keeps moisture and debris out of the ports and
contributes to the instrument’s intrinsic safety.
Proper Product Disposal At End Of Life
The Waste Electrical and Electronic Equipment (WEEE) directive (2002/96/EC) is intended
to promote recycling of electrical and electronic equipment and their components at end of
life. This symbol (crossed-out wheeled bin) indicates separate collection of waste electrical
and electronic equipment in the EU countries. This product may contain one or more Nickelmetal hydride (NiMH), Lithium-ion, or Alkaline batteries. Specific battery information is
given in this user guide. Batteries must be recycled or disposed of properly.
At the end of its life, this product must undergo separate collection and recycling from
general or household waste. Please use the return and collection system available in your
country for the disposal of this product.
Sensor Specifications, Cross-Sensitivities, And Calibration Information
For information on sensor specifications, cross-sensitivities, and calibration information, refer to RAE
Systems Technical Note TN-114: Sensor Specifications And Cross-Sensitivities (available for free
download from www.raesystems.com/downloads/tech-notes). All specifications presented in this
Technical Note reflect the performance of stand-alone sensors. Actual sensor characteristics may vary
when the sensor is installed in different instruments. As sensor performance may change over time,
specifications provided are for brand-new sensors.
The AreaRAE Plus and AreaRAE Plus/Pro share many of the same features and the same
housing. This user’s guide details all features, including those that are only available on the
AreaRAE Plus/Pro (depending your instrument’s configuration it may be configured with a
different number of sensors, different primary radio type, etc.).
The table below shows the features on the AreaRAE Plus and AreaRAE Plus/Pro.
12
AreaRAE Plus & AreaRAE Pro User’s Guide
2 Standard Contents
The AreaRAE Pro and AreaRAE Plus kit includes:
AreaRAE Pro or AreaRAE Plus monitor with sensors, battery, and wireless options as specified
and protective rubber boot installed
USB communication cable
AC/DC power adapter (90-264VAC input) plus power cords
Alkaline battery adapter
3 Spare external filters
Phillips screwdriver
Flathead screwdriver
4R+ PID opening tool (if instrument is equipped with a PID sensor)
7R+ PID cover opening tool (if instrument is equipped with a PID sensor)
PID lamp removal tool (if instrument is equipped with a PID sensor)
Lamp-cleaning kit (isopropanol)
“T”-type calibration tube
QuickStart Guide
CD with documentation
CD with ProRAE Studio II instrument configuration and data management software
Calibration and test certificate
13
AreaRAE Plus & AreaRAE Pro User’s Guide
3 General Information
Honeywell’s AreaRAE Plus/Pro is a wireless, transportable area monitor that can simultaneously detect
toxic and combustible gases, volatile organic chemicals (VOCs), radiation and meteorological factors.
Whether being used into a HazMat response, deploying it at a public venue or installed as part of a fenceline detection system — for hours, days or weeks at a time — the AreaRAE Plus/Pro gives you the right
hazard intelligence so you can ensure safety for your teams and the general public.
The AreaRAE Plus/Pro also facilitates Industrial Fence-line monitoring and has the capability to trigger
additional devices via relays.
Remote real-time monitoring of sensor data and alarm status is achieved via ProRAE Guardian software.
14
AreaRAE Plus & AreaRAE Pro User’s Guide
[N/-] key
[MODE] key
Antenna
Display
Alarm LEDs
Alarm buzzer
(on side)
RAEMet
Meteorological
Sensor
(optional)
Alarm
LEDs
Alarm
LED
[Y/+] key
External filter
And gas inlet
Charging and
USB ports
(on side)
Alarm buzzer
(on side)
3.1 Key Features
Up to seven gas sensors (PID, LEL, Toxics)
Dedicated radiation sensor slot – Gamma sensor
RAEMet station for wind speed and direction, ambient temperature, and relative humidity
Multiple onboard wireless options:
Primary radio: ISM (900/2400 MHz)/WiFi
Secondary radio: Mesh
CID2 certified for U.S., Zone 2 ATEX
Standard GPS module
Relay outputs
On the field interchangeable gas sensor (4R+ Smart sensor)
Colored rubber boots
Battery alkaline adapter
External battery charger
108dB alarm buzzer
Wraparound LED alarm
Easy serviceability (access to pump/ gas sensors/ battery)
Large Screen and intuitive User interface using icon and text (translated)
15
AreaRAE Plus & AreaRAE Pro User’s Guide
Cover all ports when
they are not in use
USB for data transfer
DC input for power and
charging the internal battery
Relay connector
Port for future features
RAEMet port
Antenna port
4 Connections
The AreaRAE Plus/Pro has six physical ports located on the left, right, and top sides. The rubber boot
has integral caps for covering the ports when they are not in use.
IMPORTANT!
Keep all ports covered when they are not in use. This keeps moisture and debris out of the ports and
contributes to the instrument’s intrinsic safety.
16
AreaRAE Plus & AreaRAE Pro User’s Guide
Icon
Function
Wireless status: the ISM or WiFi radio is on (blinks when network is not found)
Wireless status: the ISM or WiFi radio is off
ISM or WiFi radio signal 0% to 20%
ISM or WiFi radio signal 21% to 40%
ISM or WiFi radio signal 41% to 80%
ISM or WiFi radio signal 81% to 100%
ISM or
WiFi
Long-haul radio type (ISM or WiFi)
RTR
Number of Mesh Routers connected
STD
Number of standard mesh-radio devices connected
Unit of measure
Reading
Installed, active
sensors
Soft keys
(functions change
by activity)
Status indicators Datalog, battery
Pump, and “all sensors tested and
calibrated according to policy” tick
Wireless radio on/off
status, signal strength,
active radio types and
Heading (changes with alarm, etc.)
Alarm type (High,
Low, etc.)
Temperature
Relative humidity
Wind speed
Wind direction
(relative to 0° north
orientation)
5 User Interface
The AreaRAE Plus/Pro’s user interface consists of the display, alarm LEDs, an alarm buzzer, and three
keys.
5.1 Display Overview
The LCD display provides visual feedback that includes the sensor types, readings, alarm status, battery
condition, and other information.
5.1.1 Status Indicator Icons
Along the top of most screens are status indicators that tell you whether a function is operating and/or its
strength or level.
17
AreaRAE Plus & AreaRAE Pro User’s Guide
GPS enabled and power is off
(flashing) Cannot find satellite
1 to 3 satellites
4 to 8 satellites
9 to 12 satellites
Pump operating normally (alternates between these two icons)
Pump blocked (blinks once per second)
Datalogging status (shown when datalogging is on, blank when off)
Battery voltage is ≥80%
Battery voltage is ≥50% and <80%
Battery voltage is ≥10% and <50%
Battery voltage is <10%
Battery error
Sensor due for calibration
Sensor due for a bump test
“All electrochemical sensors tested and calibrated to policy” tick mark (all electrochemical
sensors have been bump tested and calibrated; no sensor is overdue for a bump test or
calibration according to the intervals configured on the instrument). This icon is not shown if
any sensor is due for bump testing or calibration, or if policy enforcement is turned off
Wind speed
Wind direction
Temperature
Relative humidity
18
AreaRAE Plus & AreaRAE Pro User’s Guide
Icon
Description
ISM or WiFi power is off
Cannot find network
Received signal strength is
>0 and <20%
Received signal strength is
≥20% and <40%
Received signal strength is
≥40% and <60%
Received signal strength is
≥60% and <80%
Received signal strength is
≥80%
5.1.2 Status Indicator Icons For Instruments Equipped with ISM radio
or WiFi
AreaRAE Plus/Pro instruments equipped with optional ISM radio or WiFi use specific icons to indicate
functionality.
19
AreaRAE Plus & AreaRAE Pro User’s Guide
Y/+
MODE
N/-
5.2 Keys And Interface
The AreaRAE Plus/Pro has three keys:
In addition to their labeled functions, [Y/+], [MODE], and [N/-] act as “soft keys” that control different
parameters and make different selections within the instrument’s menus. From menu to menu, each key
controls a different parameter or makes a different selection.
Three panes along the bottom of the display are “mapped” to the keys. These change as menus change,
but at all times the left pane corresponds to the [Y/+] key, the center pane corresponds to the [MODE]
key, and the right pane corresponds to the [N/-] key. Here are examples that show the relationships of the
keys and functions:
In addition to the functions described above, any of the keys can be used to manually activate display
backlighting. Press any key when the backlighting is off to turn it on. A subsequent key press is required
to carry out an actual function corresponding to that key.
5.2.1 Reverse Direction
Sometimes you want to go back to a previous screen rather than advance through an entire set of screens
before “wrapping around” to that screen again.
To reverse direction:
1. Press and hold [N/-] for 3 seconds.
2. When the arrow changes from pointing to the right to pointing to the left, release your finger.
Now when you press [N/-], you step back through the screens.
To change direction again: Press and hold [N/-] for 3 seconds and then release.
Note: Changing direction does not work with all screens. It works primarily in submenus.
20
AreaRAE Plus & AreaRAE Pro User’s Guide
8 Sensors with meteorology sensors
8 sensors without meteorology sensors
5.3 Screen Display For Various Numbers Of Active Sensors
The AreaRAE Plus/Pro can display readings from one to eight sensors (including dual sensors), plus four
meterology sensors (wind speed, wind direction, temperature, relative humidity) depending on the AreaRAE
Plus/Pro’s configuration. In order to maximize readability and the amount of information shown, the display is
automatically reconfigured, according to the number and types of sensors in the AreaRAE Plus/Pro.
5.4 Glance Mode
Glance Mode allows you to get vital information without turning on the AreaRAE Plus/Pro. You can
check information such as the instrument’s model and serial number, installed sensor types, wireless
modules installed, etc., which may help when taking inventory of instruments and their sensors or when
working with service or support personnel. Glance Mode can be enabled/disabled via ProRAE Studio II.
5.4.1 Enter Glance Mode
Note:The instrument must be configured so that Glance Mode is turned on (the default mode is “Off”).
This can be done in ProRAE Studio II.
With the AreaRAE Plus/Pro turned off, press and hold [Y/+] to enter Glance Mode. The feature is
latched, meaning that it runs even after you release the [Y/+] key. If you see the message “GLANCE
DISABLED,” you must configure the instrument to use Glance Mode.
If Glance Mode is enabled, the first screen is displayed. After releasing [Y/+], other screens can be
displayed by pressing the [N/-] Key. In ProRAE Studio II, Glance Mode can be enabled or disabled by
checking or unchecking the box labeled “Enable Glance Mode.”
5.4.2 Screens
Every screen displayed in sequence as configuration. Press [N/-] to advance to the next screen.
Press [MODE] to exit Glance Mode. The screens are shown in sequence.
5.4.3 Exit Glance Mode
The AreaRAE Plus/Pro exits Glance Mode and turns off when you press the [MODE] key. In addition, if
you do not press either key in 60 seconds, the AreaRAE Plus/Pro automatically exits Glance Mode.
21
AreaRAE Plus & AreaRAE Pro User’s Guide
Note:Dashed line indicates automatic progression.
5.5 Menus
The reading menus are easy to step through by pressing the [N/-] key.
Notes:
If the instrument is not equipped with a VOC sensor (PID), or is not equipped with an LEL sensor,
then screens for those sensors (VOC Gas Status and LEL Gas Status, respectively) are not shown.
If ISM or WiFi is not the primary modem, its menu is not displayed.
5.5.1 Operation Mode Navigation
22
AreaRAE Plus & AreaRAE Pro User’s Guide
RAELink3
Host
PC running
ProRAE
Guardian
AreaRAE Plus/Pro
acts as access
point and relays data
from connected
wireless instruments
MiniRAE 3000, QRAE 3, ToxiRAE
Pros, and MicroRAE connected via
Mesh radio to AreaRAE Plus/Pro
MultiRAE
connected via
Mesh radio to
AreaRAE Plus/Pro
ISM
6 Wireless Operation
Depending on the wireless configuration of the instrument and which radio modules are active, the
AreaRAE Plus/Pro can communicate directly through ISM-band radio to a RAELink3 wireless Host
modem (located up to 2 miles/3.2km away) or via WiFi to a WiFi access point. In addition, the AreaRAE
Plus/Pro is equipped with a Mesh-radio modem that communicates with Mesh-equipped instruments such
as the MultiRAE, ToxiRAE Pro, etc., located up to 330 feet (100 meters) away. Up to eight of these
instruments’ data can be relayed through the AreaRAE Plus/Pro to a PC running ProRAE Guardian to
monitor them, as well as the AreaRAE Plus/Pro.
If the AreaRAE Pro or AreaRAE Plus is equipped with WiFi, and Wifi is used as the primary radio
Note:
instead of ISM, then a WiFi access point substitutes for the RAELink3 Host.
23
AreaRAE Plus & AreaRAE Pro User’s Guide
7 Wireless Control And Submenus
When you step through the main menu, as shown in the previous diagram, there are screens for wireless
communication, including ISM, WiFi, and Mesh radio.
In order to allow turning radios on or off in the AreaRAE Plus/Pro, you can use ProRAE Studio II to set the
instrument in Advanced User Mode or Basic User Mode.
It is also necessary to select a Primary Modem if the AreaRAE Plus/Pro is equipped with both ISM and WiFi
modems.
24
AreaRAE Plus & AreaRAE Pro User’s Guide
7.1 ISM Settings
Every network using ISM radio must have a Network ID, which identifies that network and all
equipment operating in that network. All AreaRAE Plus/Pro and RAELink3 (or other RAELink
model) Host, Repeater, and Remote wireless modems in the same AreaRAE network need to be
configured with the same Network ID. Each device on the network must have a unique Unit ID.
Note: ISM Settings can be adjusted in the AreaRAE Plus/Pro’s Wireless menu under “ISM.”
25
AreaRAE Plus & AreaRAE Pro User’s Guide
8 WiFi Settings
AreaRAE Plus/Pro’s WiFi is designed to operate on a wireless network anchored by ProRAE Guardian
monitoring software and using WiFi access points. Operational distance between the instrument and the
access point (wireless router) varies, depending on distance, interference, and obstacles. It uses the
802.11b protocol using the 2.4GHz ISM (license-free) frequency band.
Note: To ensure the best communication, it is recommended that the WiFi-equipped instruments and
access point not be located close to microwave ovens, cordless telephones, or Bluetooth devices.
8.1 Setting WiFi Communication Parameters In ProRAE Studio II
WiFi-equipped instruments’ parameters for communication must be set in ProRAE Studio II.
1. Connect WiFi-equipped instrument via USB to a PC running ProRAE Studio II.
2. Place the AreaRAE Plus/Pro in Communications Mode.
3. From the main screen, press [N/-] until you see “Enter Communications Mode?”
4. Press [Y/+].
5. Select PC.
The message on the display should say “Ready To Communicate With Computer”.
1. Start ProRAE Studio II.
2. Log in using your Administrator’s password.
3. Click the “Detect Instruments Automatically” icon.
4. When your WiFi-equipped instrument is detected, click on its information and then click
“Select”.
26
AreaRAE Plus & AreaRAE Pro User’s Guide
5. Click “Setup” to download the current settings from the WiFi-equipped instrument. The main
screen appears.
6. Find and click “WiFi” in the list.
WiFi parameters appear in the right pane.
You can now change settings for the WiFi-equipped instrument. When you are done, click this icon to
send the new settings to the instrument:
8.1.1 WiFi Power
Select either “On” or “Off” to set the default power setting for your WiFi-equipped instrument.
Note: WiFi Power can also be turned on or off in the AreaRAE Plus/Pro in the Wireless menu’s “WiFi.”
8.1.2 Address
Select “Use Static IP Address” if you have a static IP or “Use DHCP” if your system allows dynamic
hosting configuration. Check with your system administrator to determine which is appropriate for your
network.
If you use a static IP address, you must provide the Static IP address, Gateway, and Subnet Mask. If you
are using DHCP, you do not have to provide these, because they will be filled in automatically.
8.1.3 Channels And Security
Check with your system administrator for the settings in this section.
8.1.4 Security Mode
Different types of wireless security guard your network against possible instances of unauthorized
access. Using security, you can:
Ensure that no one can easily connect to your wireless network without permission
Personalize access regarding who can configure your wireless settings
Protect all data that is transmitted through the wireless network
Check with your system administrator for the wireless security mode you should use.
Use the drop-down menu to select the type of security:
27
AreaRAE Plus & AreaRAE Pro User’s Guide
Security Type
Security Rank
Number of Characters
WEP (Wired Equivalent Protocol)
Basic
40/64-bit (10 characters)
128-bit (26 characters)
WPA Personal
Wi-Fi Protected Access Personal
Strong
8 to 63 characters
WPA2 Personal
Wi-Fi Protected Access 2 Personal
Strongest
8 to 63 characters
WPA2/WPA Mixed Mode
WPA2: Strongest
WPA: Strong
8 to 63 characters
Then set your Security Key.
8.1.5 Security Key
Depending on the type of security you choose, your key will have to be a different number of characters.
Here are characteristics of the different types, their relative security strength, and the number of
characters needed in the key:
Warning! Using a network with security disabled is not recommended.
8.1.6 SSID
The SSID (Service Set Identifier) is a case-sensitive unique identifier attached to the header of packets
sent over a wireless local-area network. Each wireless network in your range will have its own SSID.
Consult with your IT department for the SSID.
8.1.7 Server IP
This is the destination IP address for the instrument to communicate with a computer running ProRAE
Guardian
8.1.8 Server Port
The port number is distinct from any physical port on a computer such as a COM port or an I/O port
address. It is a 16-bit address that exists only for the purpose of passing certain types of information to the
correct location above the transport layer of the protocol stack.
9 Relays For Controlling External Equipment
The AreaRAE Pro/Plus is equipped with three solid-state relays that are switched by gas sensor alarm
conditions. These relays are always active. The relays’ contacts are protected against high in-rush current.
They can be tested by accessing Diagnostic Mode.
Status: Normally Closed (default)
Type: Dry Contact
Maximum voltage: 24VDC
Maximum amperage: 250mA
Relays open to indicate High, Low, and Sensor Failure status.
Note: If an external device is not connected, keep the dust cap on the connector to protect the pins.
Instant reading reaches the low limitation
of any sensor installed
The text “Low,” “High,” “Fail,”
“Lamp,” and “Over” flashes
alongside the readings.
2
High
Instant reading reaches the high
limitation of any sensor installed
3
Fail
Any sensor in Fail alarm, VOC sensor in
Lamp alarm, LEL sensor in Over alarm.
Pinout For Relay Port:
A mating connector for wiring to external devices is available from electronics distributors:
Samtec part number ACP-16-03-G-00.30-S-BC-O-1
Test Setup For Relays:
The output from the three potential-free relay connections for intrinsic safety (IS ic) circuits is:
Ui=24
Ii=250mA
Relay Alarm Indications
29
AreaRAE Plus & AreaRAE Pro User’s Guide
10 Battery
Always make sure the battery is fully charged before using the AreaRAE Plus/Pro. Two battery options
are available for the AreaRAE Plus/Pro (PGM-65XX):
1. Standard duration rechargeable Li-ion battery (PN: W01-3007-000)
2. Alkaline battery pack for five standard D-sized batteries (PN: W01-3007-300)
WARNING
To reduce the risk of ignition of hazardous atmospheres, recharge, remove or replace the battery
only in an area known to be non-hazardous! Do not mix old and new batteries or batteries from
different manufacturers.
10.1 Charging
Note: Batteries should be charged in an environment where the temperature is in the range of 32° to 104°
F (0° to 40° C).
Follow this procedure to charge the AreaRAE Plus/Pro:
1. Remove the cover over the AreaRAE Plus/Pro’s power port.
2. Plug the AC/DC adapter’s barrel plug into the AreaRAE Plus/Pro’s power port.
3. Plug the AC/DC adapter into the wall outlet.
The AreaRAE Plus/Pro begins charging automatically. The display shows that the battery is charging.
Green LEDs around the top of the AreaRAE Plus/Pro are used in Charge mode and Diagnostic mode.
30
Loading...
+ 94 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.