Honeywell Activ8 DT Installation Instructions Manual

Activ8 DT
Activ8 DT
Activ8 DTActiv8 DT
PASSIVE INFRARED &
MICROWAVE
MOTION DETECTOR
With PET IMMUNITY
INSTALLATION INSTRUCTIONS
P/N 7101491 REV. A A.Y.
PRODUCT DESCRIPTION
A new generation of professional movement spread spectrum analyzing PIR & MW detectors.
The Activ8 DT is a combination of PIR & MW detectors, providing protection from intruders by PYRO sensor element and MW (based on Doppler concept). Using micro controller for PIR & MW signal analyzing, with special ASIC technology for PIR pulse processing, assures “false alarm free” operation.
The Activ8 DT provides immunity up to 25Kg. For better immunity avoid installation in areas where pets can reach upwards.
Activ8 DT FEATURE S DETECTION PATTE R N
FEATURES
Quad (Four element) PYRO sensor and hard lens for outstanding detection performance and elimination of false alarms.
Microwave detection based on Doppler concept.
Unique Microwave Motion Sensor Module with microstrip patch antenna.
VLSI based electronics with movement speed spectrum analysis.
Height installation calibrations free.
User-friendly installation with or w/o swivel
bracket.
2-way Microwave sensitivity adjustment.
2-way PIR sensitivity adjustment.
BI directional temperature compensation.
Environmental immunity.
The Activ8 DT provides pet immunity up to
25Kg. Pet active bellow 1m.
REMOVAL OF FRONT COVER MOUNTING DETECTOR BASE
Unscrew the holding
screw and open base
15m
1. To remove the front cover, unscrew the holding screw and gently raise the front cover.
2. To remove the PC board, carefully unscrew the holding screw located on the PC board.
3. Break out the desired holes for proper installing.
4. The circular and rectangular indentations at the bottom base are the knockout holes for wire entry. You may also use mounting holes that are not in use for running the wiring into the detector.(For option with bracket - lead wire through the bracket)
5. Mount the detector base to the wall, corner or ceiling. (For option with bracket install bracket).
6. Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal block.
7. Replace the cover by inserting it back in the appropriate closing pins and screw in the holding screw.
SELECT MOUNTING LO CATION
DETECTOR INSTALL ATIO N CIRCUIT LAYOUT
TERMINAL BLOCK CONNECTIONS
Terminals 1 & 4 - Marked “ EOL ” – End of line
option.
Terminals 2 & 3 - Marked “ TAMPER ”
If a Tamper function is required connect these terminals to a 24-hour normally closed protective zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal will be sent to the control unit.
Terminals 5 & 6 - Marked RELAY
These are the output relay contacts of the detector. Connect to a normally closed zone in the control panel.
Terminal 7 - Marked “ + ” (+12V)
Connect to a positive Voltage output of 8.2 -16Vdc source (usually from the alarm control unit)
Terminal 8 - Marked “ - ” (gnd)
Connect to the negative Voltage output or ground of the control panel.
TYPICAL INSTALLATIO N
Choose a location most likely to intercept an intruder. (Our recommendation is a corner installation). See detection pattern. The quad­element high quality sensor detects motion crossing the beam; it is slightly less sensitive detecting motion toward the detector. The Activ8 DT performs best when provided with a constant and stable environment.
AVOID THE FOLLOWING LOCATIONs
Facing direct sunlight.
Facing areas that may change temperature
rapidly.
Areas where there are air ducts or substantial airflows.
The Activ8 DT performs better when provided with a constant and stable environment.
KNOCKOUT HOLES
A
A
A
D
BBB
CC
A. Wire access
holes
B. Us e for flat wall
mounting
C. Corner mounting -
use all 4 holes. Sharp left or right
C
C
B
angle mounting ­use 2 holes (top and bottom)
D. For bracket
mounting
SETTING UP THE DE TE CTOR
MW SENSITIVITY ADJUSTMENT
SWITCH 3 OF DIP-4 SWITCH FOR SETTINGS “MW SENSE” MW (DOPPLER) according to the environment. Position Down – “OFF” – High sensitivity
For normal operation – immediate detection.
Position Up – “ON” – Low sensitivity
For harsh environments.
-
provides sensitivity control of
POTENTIOMETER “RV2” – adjustment according to protected area range.
The potentiometer at mid-scale is equivalent to a distance of 15m, at min-scale – 7m. Rotate the potentiometer counter-clockwise to increase range, clockwise to decrease range.
Dimension change according t o installation
location and room size.
SETTING UP THE DE TECTOR TEST PROCEDURE MW PATTERN
SWITCH 1 OF DIP-4 SWITCH FOR SETTINGS “LED” - LED Enable / Disable Position On - LED ENABLE
The RED LED will activate when the detector is in alarm condition. Position Off - LED DISABLE The LEDS are disabled.
Note: the state of the switch “LED” does not affect the operation of the relay. When an intrusion is detected, the LED will activate and the alarm relay will switch into alarm condition for 2 sec.
LED
INDICATORS (Fig.4) YELLOW LED - MW detection’s GREEN LED - PIR detection’s RED LED - Alarm
PIR SENSITIVITY ADJUSTMENT
SWITCH 2 OF DIP-4 SWITCH FOR SETTINGS “PIR SENSE” - provides sensitivity control of PIR according to the environment. Position Down – “OFF” – High sensitivity
For stable environments. Position Up – “ON” – Low sensitivity For harsh environments.
POTENTIOMETER “RV1” – adjustment according to protected area range.
Use RV1 to adjust the detection range between 68% and 100% (factory set to 84%). Rotate the potentiometer counter-clockwise to increase range, clockwise to decrease range.
After adjusting the sensitivity perform a
walk test to verify optimum correct
sensitivity in the protected area.
Wait for one minute warm up time after applying 12 Vdc power. Conduct testing with the protected area cleared of all people.
Walk test
1. Remove front cover. Set LED to ON position.
2. Reassemble the front cover.
3. Start walking slowly across the detection zone.
4. Observe that the red LED lights whenever motion is detected.
5. Allow 5 sec. between each test for the detector to stabilize.
6. After the walk test is completed, you can set the LED to OFF position.
NOTE:
Walk tests should be conducted, at least once a year, to confirm proper operation and coverage of the detector.
PET IMMUNITY SETTING
SWITCH 4 OF DIP-4 SWITCH FOR SETTINGS “PET” 15kg – 25kg Position Up “ON”
Immunity to an animal up to 15 kg
Position Down “OFF”
Immunity to an animal up to 25 kg
You must reset the detector from Control Panel before the new settings will take effect.
Y
0
Table 1:
##012345678910
a 180° 130° 100° 84° 75° 70° 60° 52° 40° 30° 20° X 0 3 6 9 12151821242728,5 Y 10,5 6,09 7,15 6,98 8,01 10 , 5 10,39 10,24 8,73 7,23 5, 03
2
3
1
4
5
6
X,Y are corresponds (m) of pattern points when H=30m
H
10
9
8
7
X
WALL INSTALLATION O PTIO N CEILING INSTALLATION O P TION
TECHNICAL SPECIFICAT IO N
Detection Method Quad element PIR & microwave pulse Doppler Power Input 7.8 to 16 Vdc Current Draw Active : 25.5 mA
Standby: 16.5 mA Temperature
Compensation YES Alarm Period 2 +/- 1 sec Alarm Output N.C 28Vdc 0.1 A with 10 Ohm series protection resistors Tamper Switch N.C 28Vdc 0.1A with 10 Ohm series protection resistor - open
when cover is removed Warm Up Period 1 min LED Indicator Yellow LED is blinking during warm up period and self testing,
Red LED is ON during alarm Red LED: UNIT ALA RM Green LED: PIR CHA NNE L Yellow LED: MW CHANNEL
Dimensions 121mm x 60mm x 37mm Weight (inc. battery) 120 gr.