Honeywell 8162 User Manual

08162 TH114-A-240D TL7235
n
This thermostat can be connected to an electric heater to control the room temperature.
* The thermostat indicates how much heating is required to maintain the desired
o
The configuration switches are located at the back of the control module (faceplate).
Description
Appears when the setpoint is displayed
Heating indicator *
temperature. For example, is displayed when heating is at 40 percent.
Display % of heating 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100%
Temperature display
Temperature adjustment buttons
Backlight button
Set the switch to Off to cut power to the heater
Configuration
1.
p
Turn off power to the heating system at the main electrical panel to avoid electrical shock. The installation should be carried out by an electrician.
High voltage thermostats must be installed onto an electrical
For a new installation, choose a location about 5 ft. above the
The thermostat must be installed on an inside wall facing the
Avoid locations where there are air drafts (top of staircase, air
Installation
box.
floor and on an inside wall.
heating system.
outlet), dead air spots (behind a door), direct sunlight or con­cealed chimneys or stove pipes.
3.
n Connect the power base wires to the power supply and load
using solderless connectors for copper wires.
Power
2.
Load
The S1 switch allows you to select between °C and °F.
2.2 Model (S2)
The S2 switch allows you to control the temperature using either the thermostat’s built-in sensor or an external sensor.
AF: Use built-in sensor (external sensor not required) F: Use external sensor (option)
o If you wish to use a remote controller such as the CT240 or
CT241 from Aube, insert the cable (use 18 to 22 gauge flexible wires) into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base.
p If you use an external sensor, insert the sensor wires through
one of the two holes below the terminals (figure 2) and connect the wires to terminals 3 and 4 (no polarity).
q Push the excess length of the high-voltage wires back into the
electrical box.
r Secure the power base to the electrical box using the provided
screws.
s If necessary, set the configuration switches on the control mod-
ule (refer to the control module user guide).
08162 / TH114-A-240D / TL7235 69-2022 1/11/06 1/2 Non-programmable Thermostat - Installation and User Guide
t Install the control module onto the base. u Apply power to heating system.
NOTE: Always keep the thermostat's vents clean and unobstructed.
q
As soon as the thermostat is powered, it undergoes a series of tests before displaying the actual temperature.
r
LO: The measured temperature is below the display range. Heating is activated.
HI: The measured temperature is above the display range.
s
The display illuminates for 5 seconds when the backlight button is pressed. When either of the buttons is pressed, the display illu­minates for 10 seconds.
t
The thermostat normally displays the actual temperature. To view the setpoint, press one of the buttons once. The setpoint will appear for 5 seconds. To change the setpoint, press one of the buttons until the desired temperature is displayed. To scroll the setpoint faster, do not release the button.
u
Power supply: 208/240 VAC, 50/60 Hz Maximum load:16 A (resistive only)
Setpoint range: 40 °F - 86 °F (5 °C to 30 °C) Display range: 32 °F - 122 °F (0 °C - 50 °C) Display resolution: 1 °F (0.5 °C) Heating cycle length: 15 minutes Storage: -4 °F to 120 °F (-20 °C to 50 °C) Remote controller input (ECONO): requires a dry contact Certifications: CSA/UL
Power-up
Error Messages
Backlight
Temperature Setting
Technical Specifications
3328 W @ 208 VAC 3840 W @ 240 VAC
9.
;
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and ser-
4.
5.
6.
7.
8.
vice, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option).
If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the prod­uct was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the prod­uct within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR­RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEY­WELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR­POSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Hon­eywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.
If you have any questions about the operation of your thermostat, please go to http://yourhome.honeywell.com, or call Honeywell Customer Care toll-free at 1-800-468-1502.
Warranty
the place from which you purchased it, or
Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley, MN 55422, or whether a replacement product can be sent to you.
10.
Customer Assistance
08162 / TH114-A-240D / TL7235 69-2022 1/11/06 2/2 Non-programmable Thermostat - Installation and User Guide
Loading...