Honeywell 800-06894 User Manual

Page 1
LYNX Touch
Security System
User Guide
Ready To Arm
Arm Away
ARMED READY
Arm Stay
10:18 AM June 8, 2010
Zones
Message
System
Phone
MoreDelay
800-06894 1/11 Rev. A
Page 2
Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's control or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty. When you purchase devices that have been manufactured or approved by Honeywell, you acquire the assurance that these devices have been thoroughly tested to ensure optimum performance when used with your Honeywell security system.
– 2 –
Page 3
TABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
SYSTEM OVERVIEW.................................................................................................................................. 5
Features...................................................................................................................................................5
General Operation...................................................................................................................................6
Quick View of System Functions............................................................................................................9
About the Touchscreen Control ............................................................................................................10
Touchscreen Control Definitions ..........................................................................................................11
About the Display and Indicators.........................................................................................................13
Navigating Menus .................................................................................................................................15
SECURING THE PREMISES ..................................................................................................................17
System Status........................................................................................................................................17
Arming the System................................................................................................................................18
Entry/Exit Delays..................................................................................................................................23
Disarming the System...........................................................................................................................25
Bypassing Protection Zones..................................................................................................................27
Panic Keys .............................................................................................................................................29
Chime Mode...........................................................................................................................................31
Voice Mode.............................................................................................................................................32
USER FUNCTIONS ................................................................................................................................... 33
User Access............................................................................................................................................33
View Events...........................................................................................................................................37
Message Recording and Playback.........................................................................................................39
System Adjustment ...............................................................................................................................41
Clock/Calendar ...................................................................................................................................... 43
Programming Devices ...........................................................................................................................45
Scheduling User Interface ....................................................................................................................49
Reminders..............................................................................................................................................52
Speaker Phone Feature.........................................................................................................................55
Remote Phone Control Feature ............................................................................................................57
Remote Services ....................................................................................................................................59
FIRE/CO ALARM SYSTEM......................................................................................................................60
General Information..............................................................................................................................60
National Fire Protection Association’s Smoke Detector Recommendations.......................................61
Emergency Evacuation .........................................................................................................................62
SYSTEM FUNCTIONS ..............................................................................................................................63
Testing the System................................................................................................................................63
Maintaining Your System.....................................................................................................................65
Congratulations on your ownership of a Honeywell Security System. You have made a wise decision in choosing it, for it represents the latest in security protection technology today. Honeywell is the world's largest manufacturer of security system and millions of premises are protected by Honeywell products.
3
Page 4
TABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS ...................................................................67
System Displays ....................................................................................................................................68
Zone Status Icons ..................................................................................................................................68
Regulatory Agency Statements....................................................................................................................69
FCC STATEMENTS ..................................................................................................................................70
OWNER’S INSURANCE PREMIUM CREDIT REQUEST..................................................................73
LIMITATIONS OF THIS ALARM SYSTEM..........................................................................................76
INDEX ..........................................................................................................................................................77
TWO YEAR WARRANTY ..........................................................................................................................79
4
Page 5
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Features
General Information
This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a touchscreen control for system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning. In addition, optional wireless keypads may have been installed to allow you to control the system away from the touchscreen control. The system may also be used as a speaker phone. The system monitors protection zones and system status, displays appropriate information on the touchscreen display, and initiates appropriate alarms. Your system may also have been programmed to automatically send alarm or status messages over the phone lines or via the cellular/GSM network or the internet to a central alarm monitoring station, and may also be capable of two-way voice communication with the central station.
The user features of this security system are listed below. Ask your installer which features have been programmed for your system.
STAY and AWAY arming modes: By using these modes you can protect either the
perimeter only, or the entire premises.
Panic key functions: A designated key allow you to manually activate fire, medical
emergency, or silent police alarms. Refer to the PANIC KEYS section for detailed information.
Follow me reminder announcements: Allows the panel to dial a number that you have
specified, at a programmed time and day and deliver a message programmed by your installer.
Real-time clock: Touchscreen displays current date and time. Refer to the
CLOCK/CALENDAR section for procedures for setting the time.
Message center: The system allows recording and play back of brief messages. Refer to
the RECORDING/PLAYBACK MESSAGES section for procedures.
Two-way voice: Allows the central station to listen, talk to or conduct two-way
conversations with individuals on the premises Refer to the TWO-WAY VOICE section for detailed information.
Phone Control: Provides a remote interactive phone capability that permits access to the
security system from any off-site touch-tone telephone. Refer to the Remote Phone Control Feature section for detailed information.
Speaker Phone Operation: The system is capable of operating as a speaker phone
allowing hands free telephone conversation.
Security Codes: The system is capable of supporting an Installer code, Master user code
and 14 additional User codes including Babysitter and Duress codes. Refer to the SECURITY CODES section for detailed information.
5
Page 6
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW General Operation
Device activation: Allows you to send Follow-Me or e-mail messages, as a result of a
system event such as an alarm or trouble condition. Refer to the DEVICES section for detailed information.
Scheduling feature: Allows you to schedule the automatic activation or deactivation of
program events (e.g. alarm clock, reminder, and latch key). Refer to the SCHEDULES section for detailed information.
Zones
Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs.
Fire Protection
The fire protection portion of your security system (if used) is always active and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from the premises.
Carbon Monoxide
The carbon monoxide (CO) portion of your security system (if used) is always active and will sound an alarm if a CO condition is detected. Refer to the FIRE ALARM SYSTEM section for more information.
Burglary Protection
Your system provides two modes of burglary protection: STAY and AWAY. STAY mode protects the perimeter only, allowing you to freely move inside the premises. AWAY mode protects the entire system. Both modes provide an entry delay time that allows you to reenter the premises without setting off an alarm. For additional security, you can turn the entry delay off when arming the system. Refer to the ARMING THE SYSTEM section. The system also allows you to bypass selected zones before arming the system, if desired. Refer to the BYPASSING PROTECTION ZONES section. The system also provides a CHIME mode, for alerting users to the opening of protected doors and windows while the system is disarmed.
You must arm the burglary protection portion of your system before it will sense burglary alarms. Refer to the ARMING THE SYSTEM section for detailed procedures and information.
6
Page 7
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
General Operation
LYNX Touch SIA False Alarm Prevention Features
Many false alarms are caused by simple accidents, like forgetting to close a door when you leave. The LYNX Touch SIA includes several features that help prevent false alarms and some of these are optional or programmable. Although turning off some of these features may provide additional security, it may also increase the chance of false alarms. Your installer can help you decide whether to use the features or not. The following provides a brief explanation of the features included with your security system that help prevent false alarms from occurring, and what you should do if such alarms occur.
Exit/Entry Delays: Your security system has been programmed with delay times that allow you to
exit the premises after arming, and to disarm the system upon entry, before an alarm occurs. If you leave the premises too late when exiting, or disarm too late when arriving home, it will cause a false alarm. If an alarm occurs, you should disarm the system immediately, and wait for your monitoring company to call you.
Exit Alarms: Leaving the premises and forgetting to close the door is a common cause of false
alarms. The security system will sound an alarm, and display Exit Error. The security system provides extra time for you to disarm the system before dialing your monitoring company. Disarming the system immediately may prevent a call to your monitoring company.
Exit Time Restart-Exit Delay Restart/Reset: If you leave the premises and enter again before the
exit delay has expired, the system will restart the exit time giving you more time to leave. If there are less than 10 seconds left to exit, the system will sound fast beeps, indicating an alarm will occur soon if you fail to exit or disarm immediately. If this occurs, disarm the system and arm it again when you are ready to leave. The Exit Delay can also be restarted by pressing the RESTART Icon.
Auto Stay Feature: If you arm the system in the “AWAY mode from the controls keypad or an RF
keypad but no one exits, the alarm system will automatically change to the “STAY” mode. This will prevent you from tripping alarms by remaining on premises. Disarm the system and arm away again when you are ready to leave.
Burglary Abort Window: Your security system has a delay between the time a burglary alarm
sounds, and the time the monitoring company is called. This delay gives you time to disarm the security system before the alarm is reported to the monitoring company. This delay is factory preset at 30 seconds, but may be increased or decreased by your installer.
False Alarms: If a burglary or fire alarm condition occurs and the system has been disarmed, the
keypad will display Alarm Cancelled. If this was a false alarm, wait for the monitoring company to call you. They will verify your security code or password and prevent them from calling emergency personnel to respond to a false alarm.
7
Page 8
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW General Operation
Security Codes
At the time of installation, you were asked to provide a personal 4-digit security or “Master User code. You must enter the user code when arming and disarming the system, and when performing other system functions. As an additional security feature, other users who do not need to know your code can be assigned up to 14 different security codes. Refer to the SECURITY CODES section for procedures on adding security codes to the system.
Alarms
When an alarm occurs, the LYNX Touch internal sounder will sound for about 15-seconds, and the touchscreen displays the zone(s) causing the alarm. After 15-seconds, the internal sounder stops temporarily and voice announcements of the zones in alarm begins. When these zones have been announced, the internal sounder sounds again and the cycle repeats itself, until the system is disarmed or until alarm bell timeout occurs. If your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, simply disarm the system. The zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the DISARMING THE SYSTEM section for information about clearing the memory of alarm display
Two-Way Voice Feature
The control supports voice dialog between an operator at the central station and an individual at the premises. This feature allows the central station to listen, talk to or conduct a two-way conversation with an individual(s) at the premises and allows the operator to gather information about the nature and location of the alarm that may be helpful in responding to police or rescue departments. If the Two-way Voice Feature has been programmed and an alarm condition is detected, the system sends an alarm message to the central station. After acknowledgement is received, a listen in to follow message is sent to the central station. In response to this message, the central station operator can enter commands that allow him to initiate a 5-minute voice session.
If a subsequent zone is violated during a voice session, the system will terminate the session and process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs will alternately blink in the Talk and VOX Modes but not during Listen Mode.
8
Page 9
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONSQUICK VIEW OF SYSTEM FUNCTIONS
SECURITY FUNCTIONS
Checking system status: ............................................. Select “System” icon.
To arm in STAY mode: .............................................. Select “Stay” icon then enter Code.
To restart exit delay: ................................................... Select “Restart Exit Delay” icon.
To arm in AWAY mode: ............................................. Select “Away” icon or depress “Away” key then enter
Code.
To arm INSTANT: ...................................................... Set “Delay” to ”Instant” . Select “Stay” or “Away” icon
or “Away” key then enter code.
To arm if Quick Arm* is active: .................................... Select “Stay” or “Away” icon or “Away” key followed
by Quick Arm tab on the touchscreen.
*
User code is not required if Quick Arm is active.
To disarm system and silence alarms:......................... Depress “Off’” key or “Disarm” icon and enter Code
Note: During Entry Delay or when an Alarm Condition exists, the LYNX Touch can be disarmed by entering the User
To bypass a zone(s): .................................................. Select “Zones” icon
To turn Chime mode on or off: .................................... Select “Settings” icon
Code. Entering the OFF key is not required
MESSAGE CENTER
To record a message: ................................................. Select “Message” icon
VOLUME ADJUSTMENT
To adjust volume: ........................................................Select “Settings” icon
To restore/unmute user announcements: .................... Select “Settings” icon
SPEAKER PHONE OPERATION
To enter speaker phone mode:.................................... Select “Phone” Icon
To enable/disable (toggle) ringer: ................................Select “Settings” icon
OTHER FUNCTIONS (accessible to the Master User only)
To set the time and date: ............................................. Select “Date Time” icon (on Master User Menu)
To set scheduling:........................................................ Select “Schedules” icon (on Master User Menu)
To activate/deactivate devices:.................................... Select “Devices” icon (on Master User Menu)
To add/delete a user code* (except Master Code):......Select “Users” icon (on Master User Menu)
* Only the master code can be used to add or delete another user code.
To turn Test mode On or Off:....................................... Select “Test” icon (on Master User Menu)
To view system events:................................................Select “Events” icon (on Master User Menu)
To program or delete “Follow Me” Reminders: ............Select “Reminders” icon (on Master User Menu)
9
Page 10
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW About the Touchscreen Control
General
**IMPORTANT**
If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
The touchscreen icons and keys allow you to control all system functions. Additionally, the touchscreen display shows the zone and description of all system occurrences. When the speaker phone mode is active, a full-function telephone keypad is displayed on the touchscreen.
The system also features a built-in sounder, which will sound during alarms and troubles and a built-in speaker announces system status. Additionally, the system "beeps" during certain system functions, such as during entry/exit delay times, in Chime mode, and when depressing any of the keys (to acknowledge the key press).
The voice announcement volume is adjustable, however the “beeps” that sound in response to alarms always sound at the maximum volume level. All other “beeps” (trouble, chime, exit/entry, etc) can be set to either low or high volume.
ARMED READY
10
5000-100-002-V0
Page 11
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Touchscreen Control Definitions
1
9
2
3
ARMED READY
8 4
7 6 5
Note: The system functions described below are for reference only and require additional key entries to
activate.
1. DISPLAY WINDOW: Color Liquid Crystal Display (LCD). Displays system status icons, time,
system status information, user menus and the virtual keypad.
2. READY Indicator (LED): (GREEN) When lit, indicates system is ready to be armed; blinking
indicates system is not ready (a zone is open). Blinks once per second when AVM (VOX or Talk) or speaker phone mode is active.
3. HOME Key: Used to exit from a screen or return to the home screen.
4. Speaker: Source of audible internal warning and confirmation sounds, status announce-
ments, as well as alarms (see "Summary of Audible Notifications").
5000-100-051-V0
11
Page 12
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW Touchscreen Controls Definitions
5. OFF (Disarm) KEY: Initiates the disarm process and causes a keypad to be displayed on
the touchscreen. Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected.
6. AWAY KEY: Completely arms both perimeter and interior burglary protection for backup
protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires.
7. PANIC Key: When depressed for 4 seconds, the virtual panic icons are displayed on the
touchscreen. MICROPHONE: Used to record personal messages via the Message Center, and for two-
8. way voice and speaker phone operation.
9. ARMED Indicator (LED): (RED) Lit when the system has been armed (STAY, AWAY). Blinks when armed and fault exists, or once per second when AVM (VOX or Talk) or speaker phone mode is active.
LED Meanings
ARMED LED: ON = System armed
(Red) OFF = System disarmed Blinking = System armed, and an alarm is in progress or was previously. Blinking alternately with READY LED = speaker phone mode is active READY LED: ON = System disarmed, ready to arm (Green) OFF = System armed
Blinking = System disarmed, not ready to arm (a fault exists) Blinking alternately with ARMED LED = speaker phone mode is active.
12
Page 13
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Display Definitions
ICON TEXT
Ready to Arm
Armed Away
Armed Stay
Exit Now 28 Seconds
Alarm
About the Display and Indicators
DEFINITION
Displayed along with the the text READY TO ARM when system is Disarmed and ready to arm.
Armed Away is displayed along the top of the screen. An armed away icon along with Armed Away is displayed after the exit delay expires.
Armed Stay is displayed along the top of the screen. An armed stay icon along with Armed Stay is displayed after the exit delay expires.
“Armed Stay – Exit Now” or “Armed Away – Exit Now” is displayed in a red band along the top of the screen. An exit icon along with “Exit Now” and the time remaining (i.e.; “28 Seconds”) is displayed during the exit delay.
when the system is armed in the Stay mode. The text “Armed: Stay Exit Now Once the exit delay expires Armed: Stay is displayed along with the Home Screen.
Note: Display alternates with ARMED STAY icon and text
Alarm is displayed in a red band along the top of the screen. An alarm (bell) icon along with “Alarm” is displayed alternately with the Zone that has caused the alarm.
OR
Fault (Zone No.& Description)
Not Ready To Arm – Fault is displayed in a yellow band along the top of the screen. An open windowor door icon along with the zone descriptor and “Window” or “Door” is displayed when a window or entry/exit fault has been detected.
OR Displayed alternately with the alarm (bell) icon and “Alarm”. Alarm is also displayed in a red band along the top of the
screen.
13
Page 14
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW About the Display and Indicators
ICON TEXT
Fire OR Fire Alarm 95 Fire
Alarm 96 Medical
Alarm 99 Police
CO Alarm
Cover Tamper
Reporter Failure
Low Battery
90 RF Jam
94 Phone Line Cut
AC Loss
DEFINITION
The fire icon is displayed with alternating text “Fire” and “Fire Alarm 95 Fire”. “Fire Alarm is also displayed in a red band along the top of the screen.
The Medical icon isplayed when a medical alarm is activated. Alarm is also displayed in a red band along the top of the
screen. (If programmed for display by your installer) The alarm (bell) icon when a burglary alarm is activated.
Alarm is also displayed in a red band along the top of the screen.
(If programmed for display by your installer) Displayed alternately with the alarm (bell) icon when a CO
alarm is activated. Alarm is also displayed in a red band along the top of the
screen. A check system icon along with Cover Tamper is displayed
when a cover tamper has been detected. Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen.
The system has identified a problem with the telephone dialer.
Not Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen. A low battery icon along with Low Battery is displayed when the systems backup battery power is low.
Appears when the system has detected an RF jamming condition or excessive interference.
Appears when the system has detected a loss of telephone service.
Displayed when the system has lost AC power. Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen.
14
Page 15
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Navigating Menus
LCD Display
LYNX Touchs Liquid Crystal Display (LCD) touch-screen displays variable icons and text on screens. The screen displays status icons and associated text, the current time, system
status information and menu choices. The system status is displayed in a colored band along the top of the screen. The band color is variable and will change between red, yellow and green as the system status changes. The Menu area includes a list of commands, or choices that apply to the current selection. The status area provides information about various system events. A Home Screen is displayed whenever power is applied to the system. In addition the green ‘READY” LED will be lit.
SYSTEM
STATUS
SYSTEM/ZONE
STATUS
Ready To Arm
Zones
System
Arm Away
Arm Stay
10:18 AM June 8, 2010
Message
Phone
MoreDelay
5000-100-054-V0
LYNX Touch Home Screen (page 1)
Navigation Keys
Navigating through the screens is accomplished by lightly touching the menu item on the touch-screen. Once activated, the control will take you to the next screen. Selecting the
Home (cancel) key or the
2” Key will return you to the home screen at any time unless
System Programming mode is active.
Note: You may find it convenient to adjust the volume setting before entering the Program (Tools) Mode.
This will allow you to clearly hear the feedback announcements or system beeps in the Programming Mode, of the systems built-in speaker. To adjust the volume, select “More” on the home Screen and then select “Settings”. Adjust the volume using the slide shown on the Settings screen and then select Save to accept.
15
Page 16
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW Navigating Menus
Menu Screens
System Status is displayed at the top of each screen. The time and date are displayed at the bottom of the Home Screen.
Menus
Unrestricted Menu
The first page of the Home Screen provides access to an Unrestricted Menu displays the system status and eight selection icons or “buttons”.
1. Zones – Provides access to Zone information and options.
2. System – Provides information about system status.
3. Arm Away – Used to Arm the system in Away mode.
4. Arm Stay – Used to Arm the system in Stay mode.
5. Message – Provides access to Message Center.
6. Phone – Provides access to Speaker Phone mode (if programmed).
7. Delay/Instant – Used to toggle between exit delay and instant arming options.
8. More – Advances system to second page of the Home Screen.
The second page of the Home Screen displays the system status in and seven options.
1. Tools – Provides access User Programming Menus (Master User Code required for
access).
2. Arm Away – Used to Arm the system in Away mode.
3. Arm Stay – Used to Arm the system in Stay mode.
4. Settings – Provides access to various touchscreen functions including Brightness,
Contrast, Volume, Voice, Chime and Ringer.
5. Delay/Instant – Used to toggle between exit delay and instant arming options.
6. Back – Returns system to first page of the Home Screen.
Master Menu
The User Menu provides access to User configurable features and displays eight options. Entering the Master User Code is required to access the Master menu.
1. Users – Allows Master User to add or remove User Codes
2. Devices – Allows Master User to program output triggers.
3. Schedules – Allows Master User to program schedules
4. Test – Allows Master User to Test the system
5. Date Time – Used to program date and time.
6. Events – Allows Master User to view system events
7. Reminders – Allows Master User to add or remove local and Follow Me reminders.
8. Slide Show – Allows Master User to select a slide show for use as a screensaver.
9. Back – Returns system to first page of the Home Screen.
16
Page 17
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
System Status
General Information
Before arming your system, all protected doors, windows, and other protection zones must be closed or bypassed (see the BYPASSING PROTECTION section).
READY LED: The green READY indicator on the control will be lit if the system is ready to
NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the
current state of the system.
Depending on the current state of the system the following phrases may be heard:
fire alarm [zone voice descriptors] carbon monoxide alarm [zone voice descriptors]
alarm [zone voice descriptors] fire fault [zone voice descriptors]
carbon monoxide fault [zone voice descriptors] fault [zone voice descriptors] low battery [zone voice descriptor] system low battery check system AC loss zones bypassed chime
VOLUME LEVEL: The volume level of system announcements can be increased or decreased. Refer to the MESSAGE RECORDING/PLAYBACK section for the procedure.
System Can Be Armed
The READY LED will be lit steadily once all protection zones have been closed or bypassed. You may now arm the system.
be armed. If blinking, the system is not ready.
17
Page 18
SECURIN
SECURING THE PREMISES
SECURINSECURIN
G THE PREMISES
G THE PREMISESG THE PREMISES
Arming the System
Arming in Stay Mode
Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the control should be lit if the system is ready to be armed. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the designated entrance door without causing an alarm, but they must disarm the system within
the entry delay period or an alarm will occur. you do not need to enter the security code to arm the system. The security code must always be used to disarm the system, however.
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm the system. In addition, if the system is armed by pressing via Quick-Arming, neither the Babysitter Code nor Installer Code can disarm the system.
Ready To Arm
Zones
System
If Quick Arm was programmed by the installer,
1. Select the Arm Stay icon, the system will beep once and display a keypad.
Arm Away
Arm the system in Stay mode
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Cancel
Message
Clear
Phone
MoreDelay
5000-100-006-V0
2. Enter a valid User Code.
231
OR If Quick Arm has been enabled, select the
564
Quick Arm icon.
The system will beep three times and
897
0
5000-100-137-V0
announce delay screen will be displayed. If programmed the display will count down the time remaining in the exit delay.
Note: If a valid user code is not entered or the
Confirm icon has not been selected within 10 seconds, the system will return to the
home screen and it will not be armed.
Armed Stay Exit Now
. The exit
– 18 –
Page 19
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Armed: Stay
3. At the end of the exit delay the system will announce
Armed Stay
and
display the Armed Stay screen.
Disarm
10:18 AM June 8, 2010
Zones
Message
System
Phone
More
5000-100-056-V0
If an invalid User Code is entered, the system will return to the home screen.
Auto Stay Feature
If this feature is enabled by installer, the LYNX Touch SIA, when armed AWAY from the control’s keypad or a Wireless Keypad, switches to the STAY mode if the Exit Time expires and no exit has been made.
NOTE: If the exit route entry/exit sensor is in a check condition or has been bypassed it will result in a loss of interior
protection because the alarm system will arm STAY in this case. Consult with your installer for servicing of the entry exit zones or to turn off this feature if a check condition on entry exit zones occurs.
19
Page 20
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Arming the System
Arming In Away Mode
Use this mode when no one will be staying on the premises. Close all protected perimeter windows and doors before arming. The green READY indicator on the control should be lit if the system is ready to be armed. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises, when infrared detection devices are used. You may leave through a designated entrance door during the exit delay period without causing an alarm. You may also re-enter through the entrance door, but you must disarm the system within the entry delay period or an alarm will occur. the security code to arm the system. The security code must always be used to disarm the system, however.
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm the system. In addition, if the system is armed by pressing via Quick-Arming, neither the Babysitter Code nor Installer Code can disarm the system.
If Quick Arm was programmed by the installer, you do not need to enter
Ready To Arm
1. Select the Arm Away icon, the system will beep once and display a keypad.
Zones
System
Arm Away
Arm the system in Away mode
Enter Code:
Cancel
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Message
Clear
Phone
MoreDelay
5000-100-006-V0
2. Enter a valid User Code.
231
OR If Quick Arm has been enabled, select the
564
897
0
5000-100-053-V0
Quick Arm icon.
The system will beep two times and announce
Armed Away Exit Now
. The exit delay screen will be displayed. If programmed the display will count down the time remaining in the exit delay in seconds.
Note: If a valid user code is not entered or the Confirm
icon has not been selected within 10 seconds, the system will return to the “home” screen and it will not be armed.
20
Page 21
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Armed: Away
Disarm
10:18 AM June 8, 2010
Zones
Message
System
Phone
More
5000-100-057-V0
If an invalid User Code is entered, the system will return to the home screen.
3. If “Exit Warning” has been enabled, the system will continue to beep throughout the exit delay. Rapid beeps will sound for the final 10 seconds of the delay period. At the end of the exit delay the system will announce
Armed Away
and displays the
Armed Away screen.
21
Page 22
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Arming the System
Arming the System with no delay (Instant)
Use Instant with Stay mode when you are staying home and do not expect anyone to use the entrance door.
Use Instant with Away mode when the premises will be vacant for extended periods of time such as vacations, etc.
When armed with “Instant”, the control beeps twice, or beeps continuously if exit warning has been programmed for your system, and displays the Armed Stay Instant or “Armed Away Instant message. The red ARMED indicator lights and the system announces Armed Stay Instant –exit now” or Armed Away Instant –exit now”.
When armed with “Instant”, the system will sound an alarm if a protected door or window is opened, including the entrance door. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will sound as soon as someone reenters.
To arm the system with no delay (Instant)
Ready To Arm
Arm Away
Arm Stay
10:18 AM June 8, 2010
Zones
Message
System
Phone
MoreDelay
5000-100-006-V0
Quick Exit
If active, you can restart the exit delay at any time after arming has been armed in Stay or Away mode by selecting the Quick Exit icon. This avoids having the user disarm then re­arm the system after allowing someone to enter or exit. The system will re-arm once the exit delay expires.
Armed: Stay
Zones
System
1. Select the “Delay” tab on the home screen.
The icon will ‘toggle” and “Instant” will be displayed.
2. Arm the system in the “Stay” or Away mode
normally.
Note: The entry delay time is eliminated when
Instant is selected.
1. Select the “Quick Exit” icon to restart the exit
delay.
Note: Quick Exit is active in Away mode when : Auto
Stay mode is enabled and no entry/exit zone has been faulted during the exit delay period.
Disarm Quick Exit
10:18 AM June 8, 2010
Message
Phone
More
5000-100-060-V0
22
Page 23
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Entry/Exit Delays
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
Exit Delay
Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm. The system display will count down the time remaining in the exit delay, if programmed by your installer. If the system has been Armed Away, a slow beeping will sound throughout the exit delay period, if programmed by your installer. The exit door must be closed before the end of the exit delay. During the last 10 seconds of the exit delay fast beeps will sound as a warning that the delay time is nearing its end. The exit beeps cannot be silenced.
Restarting Exit Delay While System Armed
Ask your installer if this feature is active for your system. If active, you can restart the exit delay one time after arming in Stay or Away mode during the exit delay by selecting the Restart key. This will allowing extra time for someone to enter or exit or re-enter the property before the system is armed.
Armed: Stay - Exit Now
Exit now 28 seconds
Zones
System
Disarm
Restart
10:18 AM June 8, 2010
Message
Phone
More
5000-100-061-V0
Exit Alarms
To minimize false alarms sent to the alarm monitoring company, your system may have been programmed for this feature. Ask your installer if Exit Alarm is active for your system.
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message Alarm Cancelled is displayed, in the system bar. Additionally, Alarm and the faulted zone are displayed with their associated icons in the system/zone status area. No message is sent to the alarm monitoring company. To clear the exit alarm condition, the open zone must be secured. To clear the display, select the “Disarm” icon OR depress the “Off” key and then enter your security code. If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is still open, the alarm sound continues and an "exit alarm" message is sent to the alarm monitoring company. The message Alarm Exit Error" is displayed, in the system bar. Additionally, Alarm and the faulted zone are displayed with their associated icons in the
23
Page 24
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Entry/Exit Delays
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
system/zone status area. The alarm will continue to sound until the system is disarmed or timeout ocurs. To stop the alarm, the system must be disarmed by selecting the “Disarm” icon OR depressing the “Off” key and then entering your security code. The message “Alarm Cancelled" is displayed, in the system bar, indicating that the alarm has been cancelled (if this feature is enabled by the installer). “Alarm” and the faulted zone continue to be displayed with their associated icons in the system/zone status area. To clear the display, select the “Disarm” icon OR depress the “Off” key and then enter your security code a second time. An exit alarm also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.
Entry Delay
Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. You must disarm the system before the entry delay period ends, or an alarm will occur. The control beeps during the entry delay period, reminding you to disarm the system. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the control to disarm the system. You can also arm the system with no entry delay at all by selecting the “Delay” icon prior to arming the system. This will toggle the system to Instant, which can provide greater security while on the premises or while away for extended periods of time. See ARMING THE SYSTEM section for procedure. See your installer for delay times programmed for your system.
Exit Delay:
None, 30, 45, 60, 90 seconds, 2 minutes
Entry Delay 1:
Entry Delay 2:
LYNX Touch SIA Exit/Entry Delay Times
Exit Delay: 45, 60, 90 seconds, 2 minutes
Entry Delay 1: 30, 45, 60, 90 seconds, 2, 3, 4 minutes
Entry Delay 2: 30, 45, 60, 90 seconds, 2, 3, 4 minutes
None, 30, 45, 60, 90 seconds, 2 minutes
None, 30, 45, 60, 90 seconds, 2 minutes
24
Page 25
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Disarming the System
Select the “Disarm” icon or the “Off” key to disarm the system and to silence alarm and trouble sounds. See the SUMMARY OF AUDIBLE NOTIFICATION section for information, which will help you to distinguish between fire and burglary alarm sounds. During Entry Delay or when an Alarm Condition exists, the system will be disarmed as soon as the correct user code is entered on the touchscreen. Selecting the OFF key is not required. The entry beeps or alarm sound can be silenced by pressing any key however, it will restart in 10 seconds if the correct User Code is not entered. The READY indicator will light (if no alarms have occurred while armed) and the control will beep once to confirm that the system is disarmed.
**IMPORTANT**
If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
Disarming the system and silencing alarms
Armed: Stay
Zones
System
1. Select the Disarm icon or depress the Off key. The system will beep once and
display a keypad.
Enter Code:
Disarm
10:18 AM June 8, 2010
Message
Armed Stay
Phone
More
5000-100-056-V0
2. Enter a valid Code. The system will beep
231
564
once and announce
Arm
.
Note: If a valid user code is not entered or the
Disarmed Ready to
Confirm icon has not been selected
897
within 30 seconds, the system will return to the “home” screen and it will not be
Cancel
Clear
0
5000-100-065-V0
If an invalid User Code is entered, system will return to the home screen.
disarmed.
25
Page 26
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Disarming the System
When an Alarm Occurs
When an alarm has occurred, the touchscreen displays the zone number(s) that caused the alarm and the type of alarm (e.g., Fire Alarm). These messages remain displayed until cleared by a user. To clear the display, note the zone number displayed and enter an Off sequence. If the fault cannot be corrected, notify your alarm company.
26
Page 27
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Bypassing Protection Zones
Bypassing Individual Zones
The Bypass feature can be used when you want to intentionally arm your system with one or more zones unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an Off sequence is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful. The system will not allow panic, fire or CO zones to be
bypassed.
Bypassing zones
Arm Away
2. Front Door
Ready To Arm
Zones
Arm Stay
10:18 AM June 8, 2010
Not Ready To Arm - Fault
FAULT
Message
System
Phone
MoreDelay
5000-100-006-V0
1. With the system in the disarmed state,
select the “Zones” icon. The system displays the Zones/Bypass screen.
2. Select the zone(s) that you wish to bypass
and then select “Bypass OR if programmed, the Bypass All Faulted button allows you to bypass all faulted zones (excluding Panic, Fire or CO zones). The system displays a keypad.
Bypass All
Faulted
Bypass Selected Zones
Enter Code:
Cancel
Clear
Bypasses
Not Ready to Arm - Fault
Bypass
Clear
Select
Fault
5000-100-141-V0
3. Enter a valid Code. The system returns to
231
5
64
the Bypass screen and the zone(s) that are bypassed will be displayed.
4. Select the 2 icon to return to the home
screen.
8
0
97
5000-100-067-V0
5. Arm the system normally. See
THE SYSTEM
section for procedure
ARMING
27
Page 28
SECU
SECURING THE PREMISES
SECUSECU
RING THE PREMISES
RING THE PREMISESRING THE PREMISES
Bypassing Protection Zones
Displaying Bypassed Zones
Ready To Arm
Arm Away
2. Front Door
95. Fire
99. Police
Bypass All
Faulted
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
BYPASSED
READY
READY
Clear
Bypasses
3. Garage Door
96. Medical
Zones
Message
Bypass
READY
READY
System
Phone
MoreDelay
Select
5000-100-066-V0
5000-100-006-V0
All
1. With the system in the disarmed state,
select the “Zones” icon. The system displays the Zone screen and the status for each zone will be indicated.
2. Use the S” “T buttons to scroll to
additional pages and view the zone status.
3. If you select the Select All button it
functions scrolls through the following: Select All, Select Alarm, Select Trouble and Select Fault. The system will display the associated zones.
28
Page 29
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Panic Keys
Panic Keys
Your system may have been programmed to use special keys to manually activate panic functions. The functions that might be programmed are listed below. See your installer for the function(s) that may have been programmed for your system.
Note: Your installer should advise which functions are active in your system.
Key Function
When activated, alerts the alarm monitoring company that a fire condition exists.
When activated, alerts the alarm monitoring company that a police emergency exists.
When activated, alerts the alarm monitoring company that a health emergency exists.
Types of Panic Alarms
A silent emergency/silent alarm sends an alarm signal to the alarm monitoring
company, if your system is connected to an alarm monitoring company, but there will be no audible alarms or visual displays.
An audible emergency/audible alarm sends an emergency message to the alarm
monitoring company, if your system is connected to an alarm monitoring company, and sounds a loud, steady alarm at your control. (ALARM will be announced and the Alarm icon is displayed along with “Alarm” and Alarm 99 Police alternately.
A personal emergency/aux alarm sends an emergency message to the alarm
monitoring company, if your system is connected to an alarm monitoring company, and sounds at controls, but not at external sounders. . (ALARM will be announced and the Alarm icon is displayed along with “Alarm” and with Alarm 96 Medical”.
A fire alarm sends a fire alarm message to the alarm monitoring company, if your
system is connected to an alarm monitoring company, and uniquely activates the sounder. The Fire Alarm icon is displayed along with Fire Alarm 95 Fire”.
29
Page 30
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Panic Keys
Activating a panic alarm
Ready To Arm
Zones
System
1. With the system in the disarmed or armed
state, depress and hold the “Panic” key until the system displays the Panic screen (approximately 3-4 seconds).
Arm Away
Police
Enter Code:
Cancel
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Fire Alarm Fire
Fire
Fire Alarm
Message
Clear
Medical
Phone
MoreDelay
5000-100-006-V0
2. Touch the desired panic icon on the screen.
3. If applicable, the alarm will sound and the
associated icon will be displayed.
5000-100-068-V0
Note: Dependant upon how your system has
231
been programmed a keypad may be displayed. This will allow you to cancel
564
the alarm by entering valid User Code on the keypad.
897
0
5000-100-149-V0
30
Page 31
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Chime Mode
Chime Mode
Your system can be set to provide you with an audible alert of the opening of a door, while it is disarmed, by using Chime mode. When activated, three beeps will sound at the control whenever a protected perimeter door is opened and the zone voice descriptor will be announced. Additionally, the faulted zone information will be displayed on the home screen. Selecting the “Zones” icon displays the open protection points. The Chime mode can be turned on only when the system is disarmed.
Turning Chime mode On or Off
Ready To Arm
Arm Away
Brightness
Contrast
Volume
Off
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Off Off
1. With the system in the disarmed or armed
state, select the “Settings” icon from the second page of the Home Screen. The
Tools
system displays the Setting screen.
Settings
BackDelay
5000-100-007-V0
2. Select the “Chime” icon. The system will
toggle between “Off” and “On”. When “On” is selected, the Chime mode will be active.
3. Select the “Save” button to save your new
settings.
RingerChimeVoice
Save
5000-100-008-V0
31
Page 32
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Voice Mode
Voice Mode
Your system can be set to provide you with a voice alert of system functions by activating the Voice mode. When activated, the system will announce the system status when armed/disarmed. The Voice mode can be turned on only when the system is disarmed.
Turning Voice mode On or Off
Ready To Arm
Arm Away
Brightness
Contrast
Volume
Off
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Off Off
Zones
Message
1. With the system in the disarmed or armed
state, select the “Settings” icon from the second page of the Home Screen. The
System
system displays the Keypad screen.
Phone
MoreDelay
5000-100-006-V0
2. Select the “Voice” icon. The system will
toggle between “Off” and “On”. When “On” is selected, the Voice mode will be active.
3. Select the “Save” button to save your new
settings.
RingerChimeVoice
Save
5000-100-008-V0
32
Page 33
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
User Access
General Information
For additional security you (the Master User Code) can assign secondary user codes to individual users enabling them to perform specific system functions. These secondary users are identified by "User Numbers" when their codes are assigned. You can assign up to 14 user codes. Note that the Master User is the only one who can assign codes to secondary users.
All codes can be used interchangeably when performing system functions (a system armed with one user's code can be disarmed by another user's code), with the exception of the Babysitter Code described below.
Babysitter Code: This code can be used to arm the system, but cannot disarm the system unless the system was armed with this code. This code is typically assigned to someone (such as a babysitter) who needs to arm/disarm the system only at certain times.
Duress Code: This feature is intended for use when you are forced to disarm or arm the system under threat. When used, the system will act normally, but can silently notify the alarm monitoring company of your situation, if that service has been provided. The
Duress Code is useful only when the system is connected to an alarm monitoring company.
IMPORTANT: Temporary users of the system (e.g., babysitters, cleaning staff) should not
be shown how to use any system function they do not need to know, such as bypassing protection zones for example.
False Alarm Prevention Feature
The system prevents User Codes (including the Duress Code) from being duplicated. If you have attempted to assign a duplicate 4-digit code, the entry will be rejected. Any previous existing code will remain unchanged. Choose a different new 4-digit code and repeat the procedure.
Adding a User
Arm Away
Ready To Arm
Arm Stay
10:18 AM June 8, 2010
Tools
Settings
BackDelay
5000-100-007-V0
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
33
Page 34
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS User Access
Program the system
Enter Code:
Cancel
Master ****
Duress ****
Ready To Arm
Ready To Arm
Events
Ready To Arm
Babysitter ****
Clear
Reminders
2. Enter your 4-digit Master User Code. The
231
5
8
0
64
97
5000-100-009-V0
system displays the Master User programming screen.
3. Select the “Users” icon. The system displays the Master User screen.
TestSchedulesDevicesUsers
Slide ShowDate Time
Back
5000-100-070-V0
4. Select the Add New key. The system displays a keyboard.
Note: **** appears to the right of User name after a
valid 4-digit User Code has been assigned to a specific User.
Edit Add New Delete
Ready To Arm
W
A
abc...
User3
S
Z
T
R
E
D
X
Y
G
F
V
C
123!@#
Q
Clear
5000-100-069-V0
5. If desired you can enter a User Name. Select the “Clear” key and then enter up to 10 characters of text.
U
L
K
J
H
M
N
B
Note: Select the “ABC…” key to switch the keyboard
between upper/lower case or the “123!@# key to switch to numbers.
6. Once you are finished, select “Done”. The
OP
I
system displays the Keypad screen.
Done
5000-100-081-V0
34
Page 35
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
User Access
Ready To Arm
Enter Code
Clear
Ready To Arm
Master ****
Duress ****
Edit Add New Delete
Babysitter ****
Thomas ****
Editing/Deleting a User
Ready To Arm
7. Enter the 4-digit code for the new User
231
64
5
followed by “Done”. The system returns to the Users screen and the new User is displayed.
97
8
0
Done
5000-100-185-V0
5000-100-142-V0
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays
Tools
the Keypad screen.
Arm Away
Program the system
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Cancel
Clear
Settings
BackDelay
5000-100-007-V0
2. Enter your 4-digit Master User Code. The
231
system displays the Master User programming screen.
5
8
0
64
97
5000-100-009-V0
35
Page 36
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS User Access
Ready To Arm
Events
Ready To Arm
Ready To Arm
R
F
D
C
X
Ready To Arm
Clear
Babysitter ****
Thomas ****
T
G
V
Master ****
Duress ****
Edit Add New Delete
W
A
abc...
User3
E
S
Z
123!@#
Q
Clear
Enter Code
Reminders
Y
H
B
231
5
8
0
3. Select the “Users” icon. The system displays the Users screen.
TestSchedulesDevicesUsers
Slide ShowDate Time
Back
5000-100-070-V0
4. Select a User Name and then select “Edit” or Delete. If you are editing user information proceed to step 5. If you are deleting a user, proceed to step 8.
5000-100-142-V0
5. If desired you can revise a User Name. Select the “Clear” key and then enter the desired text.
U
L
K
J
6. Once you are finished, select “Done”. The system displays the Keypad screen. If your
OP
I
wish to change the assigned User Code,
M
N
Done
5000-100-081-V0
proceed to Step 7 otherwise proceed to Step
9.
7. If desired, enter a new 4-digit code for the selected User followed by “Done”. The system returns to the Users screen.
64
8. Select “Yes” or “No” when the confirmation screen is displayed then proceed to step 9.
97
9. Select the 2 icon to return to the Master User screen.
Done
5000-100-185-V0
36
Page 37
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
View Events
This feature can be used to view a number of System Events including Arming/Disarming, Zone Activity, Troubles and Alarms.
Viewing System Events
Ready To Arm
Tools
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
Arm Away
Program the system
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Cancel
Events
Clear
Ready To Arm
Reminders
Settings
BackDelay
5000-100-007-V0
2. Enter your 4-digit Master User Code. The
231
system displays the Master User programming screen.
5
8
0
64
97
5000-100-009-V0
3. Select the “Events” icon. The Events screen will appear and displays all events.
TestSchedulesDevicesUsers
Slide ShowDate Time
Back
5000-100-070-V0
37
Page 38
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS View Events
Sun Jun 13, 2010 15:08 Disarmed User 2 E 441
Sat Jun 12, 2010 11:08 Burglary Bypass Zone 3 E 570
Fri Jun 11, 2010 18:08 Armed Away User 2 R 401
Fri Jun 11, 2010 11:08 Armed Stay User 2 R 441
All
Trouble
Open or Close
Ready To Arm
Sat Jun 12, 2010 11:15 Armed Stay User 1 R 441
Sat Jun 12, 2010 10:15 Disarmed User 1 E 401
Fri Jun 11, 2010 12:10 Disarmed User 3 E 441
Fri Jun 11, 2010 10:15 Burglary Bypass Zone 3 E 570
Ready To Arm
Alarm
Bypass
Non Security
All
5000-100-072-V0
5000-100-071-V0
4. If you wish to view specific system history, select All. The system displays a new menu.
5. Select from the menu to display the specific event types that you wish to view.
Note: Only the event types that were
programmed by your installer are available for viewing.
38
Page 39
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Message Recording and Playback
The LYNX Touch Message Center allows you to record, play and delete messages. The maximum message duration is 180 seconds.
NOTES: (1) If the system loses electrical power, all messages will be erased.
(2) Message Play/Record will not be available if a report must be sent.
Entering message mode
Ready To Arm
Zones
System
1. With the system in the disarmed state,
select the “Message icon from the Home Screen. The system displays the Message screen.
Arm Away
Arm Stay
10:18 AM June 8, 2010
Recording a message
Ready To Arm
Add New
Message 2
Record DeletePlay
Play
Ready To Arm
Message
Delete All
Stopped
Phone
MoreDelay
Save
5000-100-045-V0
5000-100-047-V0
5000-100-006-V0
1. Select “Add New”. The system displays the Record Message screen.
2. Select “Record”, the system will sound a single tone. Speak into the microphone and record your message.
3. When you are finished recording your message, select. “Stop”
4. To listen to the message, select “Play”.
5. If you wish to delete the message, select Delete.
39
Page 40
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Message Recording and Playback
Ready To Arm
Message 1 2:48 PM September 1, 2010
Message 2 5:09 PM September 5, 2010
Add New Delete AllPlay
5000-100-046-V0
NOTE: If you are trying to record a new message and the message center is already full, Add New will not
be displayed. If the message center is full all old messages must be deleted before new messages can be recorded. See Deleting Messages section.
Playing a message(s)
Ready To Arm
Message 1 2:48 PM September 1, 2010
Message 2 5:09 PM September 5, 2010
Add New Delete AllPlay
5000-100-046-V0
6. When you have finished recording, select 2. The system displays the recorded messages.
7. To record additional messages (if recording time is available) repeat steps 1 through 3.
1. At the Message screen, select the
message you wish to play.
2. Select “Play”, the system plays your
message.
3. When you are finished listening to the
message, you may select. “Stop”. If “Stop” is not selected the system continues to play the remaining messages.
4. When you have finished listening to the
messages, select 2. The system returns to the Home Screen.
Deleting messages
Ready To Arm
Message 1 2:48 PM September 1, 2010
Message 2 5:09 PM September 5, 2010
Add New Delete AllPlay
5000-100-046-V0
1. At the Message screen, select Delete All”.
The system deletes all messages.
2. When you have finished deleting the
messages, select 2. The system returns to the Home Screen.
40
Page 41
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
System Adjustments
The volume level of message playback, system announcements, and status beeps can be changed if desired. Additionally, you can adjust the displays brightness and contrast and turn on or off the Chime or turn off the telephone Ringer.
Ready To Arm
Tools
1. With the system in the disarmed or armed state, select the “Settings” icon from the second page of the Home Screen. The system displays the Settings screen.
Arm Away
Brightness
Contrast
Volume
Off
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Off Off
Settings
BackDelay
5000-100-007-V0
2. Increase or decrease the Display Brightness or Contrast or the System Volume by using the sliding adjustment from left (decrease) to right (increase).
3. Turn On or Off the Voice, Chime or telephone Ringer by selecting the appropriate icon. The system toggles between On and Off.
RingerChimeVoice
Save
5000-100-008-V0
4. Select “Save” when you are finished. The system returns to the second page of the Home Screen.
41
Page 42
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Clock/Calendar
Note: If your system is equipped with a GSMVLP5 or ILP5 Communication Module, the time and date will
be programmed and updated automatically via Central Station. You may still program the correct Time Zone as shown below. Check with your installer to see if your system is equipped with a Communications Module.
Setting the date and time
Note: The system must be disarmed in order
to set the date and time.
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
2. Enter your 4-digit Master User Code. The system displays the Master User programming screen.
Arm Away
Program the system
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Ready To Arm
Tools
Settings
BackDelay
5000-100-007-V0
231
5
64
97
5000-100-009-V0
3. Select the “Date Time” icon. The Calendar
Cancel
Clear
Ready To Arm
8
0
screen will appear.
TestSchedulesDevicesUsers
Events
Reminders
Slide ShowDate Time
Back
5000-100-070-V0
42
Page 43
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
6
13
20
27
Enter Time
10:21 AM
AM / PM
Eastern (EST)
Day Light Savings Time
System Programming...
June 2010
TUEMON
1
8
7
Time Zone
Yes
Start Month
March
End Month
November
THUSUN WED
FRI
32
4
1110
1817
2524
3028 29
System Programming
231
5
8
Clear
Ready To Arm
0
Start Week
Second
End Week
First
Clock/Calendar
4. Select the correct month by using the W and X.
SAT
5
129
191614 15
262321 22
Save
5000-100-016-V0
64
97
Save
5000-100-010-V0
Save
5000-100-022-V0
5. Select the correct year by using the W and X”.
6. Select the correct day on the calendar.
7. When you have finished select the T icon. The system advances to the time screen.
8. If the displayed time is not correct, select Clear then enter the correct time (4 digits) on the keypad and select AM or PM.
9. When you have finished select the T icon. The system advances to the next screen OR proceed to step 17.
10. Select Time Zone. The system scrolls between through the following options:
Eastern (EST) Central (CST) Mountain (MST) Pacific (PST) Hawaii (HAST) Alaska (AKST)
Select the correct time zone.
11. Select Day Light Savings Time. The system toggles between “Yes” and “No”.
Note: The start month/week and end month week are
default programmed to “March/Second” and November/First respectively. Steps 13 to 16 should only be performed if you wish to change those entries. If you are not changing the defaults, advance to step 17.
43
Page 44
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Clock/Calendar
Ready To Arm
January February
March April
May June
July August
5000-100-075-V0
12. Select Start Month. The system displays a calendar. Select the correct month.
13. Select Start Week. The system will toggle between:
Second Third Fourth First
14. Select End Month. The system displays a
calendar. Select the correct month.
15. Select End Week. The system will toggle
between:
First Second Third Fourth
16. When you are finished select the “Save”
key. The system returns to the Master User
program screen.
44
Page 45
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Programming Devices
General Information
The Device programming option can be used to trigger device, send Follow-Me or E-mail messages of system events. Up to 16 devices can be programmed. Devices 1 through 8 are used for Triggers and Follow-Me Messages and Devices 9 through 16 are used for E-mail events. Check with your Installer to see which options are available to you.
The following options are programmed in this section:
Programming Field Action
Device 1 -16: Select Device 1 -16 Name: Name the device Action: Select the action required for the device Start Zone Type: Select Zone Type to trigger event Stop Zone Type: Select Zone Type to stop event Start System Operation: Select System Operation to trigger event Stop System Operation: Select System Operation to stop event Zone Number Operation: Select Zone Number to trigger event upon fault, trouble or alarm
as selected.
Programming Devices
Ready To Arm
Tools
1. With the system in the disarmed state, select the Tools icon from the second page of the Home Screen. The system displays the Keypad screen.
Arm Away
Program the system
Enter Code:
Cancel
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Clear
Settings
BackDelay
5000-100-007-V0
2. Enter your 4-digit Master User Code. The
231
system displays the Master User programming screen.
5
8
0
64
97
5000-100-009-V0
45
Page 46
USER FUNCTION
USER FUNCTIONSSSS
USER FUNCTIONUSER FUNCTION Programming Devices
Ready To Arm
TestSchedulesDevicesUsers
3. Select the “Devices” icon. The system displays the Devices screen.
Events
Ready To Arm
Ready To Arm
R
F
D
C
X
Ready To Arm
Device 2
New
Device 4
New
Device 6
New
T
G
Device 1
New
Device 3
New
Device 5
New
Edit Delete
123!@#
Q
W
E
A
S
Clear
Z
ABC...
Name
Type
Disabled
V
Reminders
Y
H
B
01
Slide ShowDate Time
Back
5000-100-070-V0
4. Select a “Device” key followed by the Edit button. The system displays a keyboard.
5000-100-187-V0
5. If desired you can enter a Device Name. Select the Clear key and then enter up to 13
OP
I
U
L
K
J
M
N
Done
5000-100-190-V0
characters of text.
Note: Select the “ABC…” key to switch the keyboard
between upper/lower case or the “123!@#” key to switch to numbers.
6. Once you are finished, select “Done”. The system returns to the Device screen.
7. Select the “Type” button. Dependant upon what features are programmed in your control the system toggles between the following options: Disabled Trigger Output Message to Phone 1 Message to Phone 2
Save
5000-100-188-V0
Message to ph. 1&2 Email 1
When an option is selected, the system displays
several new programming fields.
46
Page 47
Name
Type
Trigger Output
Start Zone Type
Not Used
Start System Operation
Not Used
Ready To Arm
01
Action
None
Stop Zone Type
Not Used
Stop System Operation
Not Used
Save
5000-100-189-V0
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Programming Devices
8. Select “Action”. Dependant upon the Type
selected previously, the system scrolls between several options:
None Permanent On On for 2 sec Pulsing Send
9. Select “Start Zone Type”. The system displays
the following options:
Not Used Entry Exit 1 Entry Exit 2 Perimeter Interior Follower Day/Night 24 Hour Silent 24 Hour Audible
Use the S” “T buttons to scroll to second
page of zone type options.
Silent Burglary 24 Hour Auxiliary Interior With Delay Fire No Verification Carbon Monoxide Trouble No Response Arm Stay
Use the S” “T buttons to scroll to third page
of zone type options.
Arm Away Disarm Monitor Resident Monitor Resident Response General Monitor General Response
10. Select Stop Zone Type. The system displays
the same options as step 9.
11. Select Start System Operation. The system
displays the following options:
Not Used Arm Stay Arm Away Disarm Any Burglary Alarm Any Fire Alarm Bell Timeout End of Exit Delay
Use the S” “T buttons to scroll to second
page of zone type options.
Start of Entry Delay Chime Kissoff Bypass System Low Battery Reporter Failure Duress Alarm
12. Select Stop System Operation. The system
displays the same options as step 11. Use the S” “T” buttons to scroll to second
page of options.
47
Page 48
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Programming Devices
Ready To Arm
Zone Number Operation
Not Used
Ready To Arm
Zone Number Operation
Fault
First Start Zone
Disabled
Second Start Zone
Disabled
Third Start Zone
Disabled
Editing or Deleting Devices
Device 1 System Armed Follow Me
Device 3
New
Device 5
New
First Stop Zone
Disabled
Second Stop Zone
Disabled
Third Stop Zone
Disabled
Ready To Arm
Device 2
New
Device 4
New
Device 6
New
Save
5000-100-191-V0
Save
5000-100-192-V0
13. Select Zone Number Operation. The system
toggles between the following options:
None Trouble Fault Alarm
If Trouble, Fault or Alarm is selected, the system
displays several new options:
14. Select a Start Zone or Stop Zone Number from
the list displayed by the system.
15. Select “Save” when programming is complete.
1. At the Device Programming Screen, select the
Device that you wish to edit or delete.
2. To delete the device, select the delete button.
To edit the device select the Edit button and proceed to step 3.
Edit Delete
Ready To Arm
Name
System Armed
Type
Message to phone 1
Start Zone Type
Not Used
Start System Operation
Armed Stay
Stop Zone Type
Stop System Operation
01
Action
Send
Not Used
Disarm
5000-100-194-V0
Save
5000-100-195-V0
3. Select the field that you wish to edit and follow
the steps as outlined in the Programming
Devices procedure.
48
Page 49
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Scheduling User Interface
The Scheduling Feature can be used to program the system to automatically perform certain functions (i.e.; automatically arming the system in Stay mode and activating output devices).
Programming a Scheduled Function
Arm Away
Program the system
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Cancel
Ready To Arm
Clear
Ready To Arm
Tools
Settings
BackDelay
5000-100-007-V0
231
5
8
0
64
97
5000-100-009-V0
TestSchedulesDevicesUsers
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
2. Enter your 4-digit Master User Code. The system displays the Master User programming screen.
3. Select the “Schedules” icon. The system displays the Scheduling screen.
Events
Reminders
Slide ShowDate Time
Back
5000-100-070-V0
49
Page 50
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Scheduling User Interface
Ready To Arm
4. Select “Add New”. The system displays the scheduling options screen.
Edit
123!@#
Q
A
Clear
abc...
W
Name
Type
None
User3
S
Z
E
D
X
Add New
Ready To Arm
Ready To Arm
T
R
G
F
V
C
Frequency
None
Y
H
B
Delete
U
J
N
I
K
M
5000-100-146-V0
Save
5000-100-144-V0
OP
L
Done
5000-100-081-V0
5. Select “Name”. The system displays a keypad.
6. Enter a name (up to 13 digits long) for the scheduled function on the displayed keypad then select “Done”.
7. Select “Frequency” then select one of the following displayed options:
None Once Daily Weekday Weekly Monthly
8. Program the following options based upon the Frequency selected in step 7: Once Date
Daily Weekday Start Time Weekly Day of the Week Monthly Day of the Month
9. Select “Type” then scroll through and select one of the following options:
None Auto Stay Output Disarm Notification
50
Page 51
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Enter Time
10:21 AM
AM / PM
Ready To Arm
Clear
231
5
8
0
Editing a Scheduled Function
Ready To Arm
Auto Arm -Auto Stay -Daily
Edit
Add New
Delete
Scheduling User Interface
10. If Auto Stay is selected, select “Clear” then
enter a 4-digit time on the displayed keypad then select “Save”. If Output is selected
64
97
Done
5000-100-147-V0
5000-100-179-V0
proceed to Step 11. If Disarm Notification is selected proceed to Step 12.
11. Select a Device (Device 1 through Device
16).
12. Enter a Start Time and End Time on the
displayed keypad then select “Save”.
1. At the Schedules screen, select the Schedule you wish to edit.
2. Select the “Edit” button. The Schedule programming screen will appear. Follow the steps as noted above in the programming a Scheduled Function section to edit and save your changes.
Deleting a Scheduled Function
Ready To Arm
Auto Arm -Auto Stay -Daily
Edit
Add New
Delete
5000-100-179-V0
1. At the Schedules screen, select the Schedule you wish to delete.
2. Select the “Delete button. A confirmation screen will be displayed. Select “Yes” to confirm the deletion.
3. Select the 2” button. The system returns to the Master User programming screen.
51
Page 52
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Reminders
The Reminder Feature can be used to program/record reminders that can be displayed on the touchscreen, announced by the control and/or sent to one ort two pre-programmed phone number(s). Check with your installer to see if the latter feature has been programmed on your control.
Programming a Reminder
Ready To Arm
Tools
1. With the system in the disarmed state,
select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
Arm Away
Program the system
Enter Code:
Cancel
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Ready To Arm
Events
Clear
Reminders
Settings
BackDelay
5000-100-007-V0
2. Enter your 4-digit Master User Code. The
231
system displays the Master User programming screen.
5
8
0
64
97
5000-100-009-V0
3. Select the “Reminders” icon. The system
displays the Reminders screen.
TestSchedulesDevicesUsers
Slide ShowDate Time
Back
5000-100-070-V0
52
Page 53
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
No items to display!
Edit
Name
Voice
No
123!@#
Q
W
E
A
S
Clear
Reminders 1
Z
abc...
Record DeletePlay
Ready To Arm
Add New
Ready To Arm
Ready To Arm
R
F
D
C
X
Ready To Arm
Reminders
4. Select “Add New”. The system displays the Reminder programming screen.
Delete
5000-100-178-V0
5. Select “Name”. Enter a name for the
Frequency
None
Acknowledge
No
T
U
Y
G
V
J
H
N
B
Stopped
I
K
M
Save
5000-100-176-V0
OP
L
Done
5000-100-180-V0
5000-100-182-V0
scheduled function on the displayed keypad then select “Done”.
6. Select “Frequency” then select one of the following displayed options:
None Once Daily Weekday Weekly Monthly
7. Program the following options based upon the Frequency selected in step 6:
Once Date/Start Time Daily Start Time Weekday Start Time Weekly Days of the Week/Start Time Monthly Day of the Month/Start Time
8. If a voice reminder is desired, select Voice. The system toggles between No and Yes. If yes is selected, the record reminders screen appears.
9. Select the “Record” button and record your reminder. When you are finished select the Stop button followed by the 2 button. The system returns to the Reminder programming screen.
53
Page 54
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Reminders
Ready To Arm
Name
Walk Dog
Date
January 1, 2011
Start Time
3:00 PM
Voice
No
Follow Me
Disabled
Editing a Reminder
Ready To Arm
Walk Dog - Daily
Edit
New
Frequency
Once
Acknowledge
No
Delete
Save
5000-100-183-V0
5000-100-184-V0
10. If a Follow Me phone number(s) was programmed by your installer you can send a reminder to the phone number(s). Select Follow Me option. The system toggles between Disabled, To Ph. 1, To Ph. 2 and To Ph. 1 & 2”, as applicable.
Note: For important reminders you should
program the “Acknowledge” option. When this option is selected, the reminder will continue to play until it is acknowledged.
11. Select the “Acknowledge” option. The system toggles between No and “Yes”.
12. Select “Save” when all applicable options have been programmed.
1. At the Reminders screen, select the reminder you wish to edit.
2. Select the “Edit” button. The Reminder programming screen will appear. Follow the steps as noted above in the programming a Reminder section to edit and save your changes.
Deleting a Reminder
Ready To Arm
Walk Dog - Daily
Edit
New
Delete
5000-100-184-V0
1. At the Reminders screen, select the reminder you wish to delete.
2. Select the “Delete button. A confirmation screen will be displayed. Select “Yes” to confirm the deletion.
3. Select the 2” button. The system returns to the Master User programming screen.
54
Page 55
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Speaker Phone Feature
If this feature has been programmed the LYNX Touch is capable of operating as a speaker phone. During speaker phone operation the system will provide the following functions:
All function/event processing will continue to operate, but there will be no announcements.
NOTE: The system will enter the Speaker Phone mode even if an alarm or trouble is stored in the system
memory.
Do not use the speaker phone as the only telephone in your home since in some special cases the speaker phone is not functional.
!
The system will not enter speaker phone mode and LYNX Touch will not ring if:
The feature has not been programmed.
A report is being sent.
An audible alarm is present.
An announcement is being made or a recorded message is being played back.
A message is being recorded.
If the system is in test or sniffer mode.
AC power is not present
The speaker phone will be aborted if:
A report must be sent.
An audible alarm or trouble has ocurred.
AC power is lost.
Using the Speaker Phone Feature
When the LYNX Touch is operating in the Speaker Phone mode, if a zone is violated and has triggered an entry/exit delay, the system will automatically change the touchscreen from telephone to security mode. This allows the user to disarm the system or take other appropriate actions in the security mode without interrupting the telephone session. To regain telephone keypad control you will need to reactivate the telephone keypad.
55
Page 56
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS Speaker Phone Feature
Placing a Call
Ready To Arm
Zones
System
1. With the system in the disarmed or armed state, select the “Phone” icon from the Home Screen. The system displays the Keypad screen.
Arm Away
Talk
Volume
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Answering a Call
Ready To Arm
Arm Away
Talk
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Message
231
5
8
0
Zones
Message
231
5
8
Phone
MoreDelay
5000-100-006-V0
2. Select the “Talk” icon and then enter the number you wish to dial. The “End” icon replaces the “Talk” icon. Selecting the
64
Redial icon will allow you to redial the last number that was dialed.
97
Flash
3. Select the “Flash” icon to switch between two calls.
Redial
5000-100-148-V0
4. Select the “End” icon to hang up and end the call.
1. With the system in the disarmed or armed state, select the “Phone” icon from the Home Screen. The system displays the
System
Keypad screen.
Phone
MoreDelay
5000-100-006-V0
2. Select the “Talk” icon. The “End” icon replaces the “Talk” icon.
3. Select the “End” icon to hang up and end
64
97
Flash
the call.
Volume
0
Redial
5000-100-148-V0
56
Page 57
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Remote Phone Control Feature
The LYNX Touch Series is equipped with a remote interactive phone capability that permits access to the security system from any off-site touch-tone telephone using all user codes. The system will provide the appropriate voice messages and any system beeping sounds indicating the status of the security system over the phone line. (Refer to Summary of Audible Notification for further information.) The following functions can be performed from any remote touch-tone telephone:
Disarm the system.
Arm the system in STAY or AWAY mode.
Bypass zones.
Check system status.
The remote access session will be aborted if:
A report must be sent.
Any local or wireless key entry is made.
User Code is not entered within eight (8) seconds of call pickup (during the
system..system announcement).
No keys are depressed for a period of 15 seconds and while no announcement has been made by the system. Any remote key entry will, however extend this timeout back to 15 seconds.
It will not be possible to begin a remote access session if:
A report must be sent
The system is in any Test mode.
Panel is in shutdown mode (programmed by your installer).
Using Remote Phone Control Feature
Dial the controlss phone number. If no answering machine is present, the control will pick up between 1 and 14 rings, depending on the number programmed by your installer and will periodically announce SYSTEM ENTER CODE. If an answering machine is on the premises, you need to dial the premises and hang up on the first ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number again. The control will pick up and periodically announce “SYSTEM”.
57
Page 58
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Remote Phone Control Feature
Remote Phone Control Commands
Enter User Code (within eight seconds). Upon entering remote phone control mode the Lynx will announce System, enter code.
To remotely disarm system:........................................................... User Code + [1]
To remotely arm in AWAY mode: .................................................. User Code + [2]
To remotely arm in STAY mode: ................................................... User Code + [3]
To remotely arm in AWAY or STAY mode with no delay:.............. User Code + [2] or [3] + [0]
To remotely Bypass zones: ........................................................... User Code + [6] + zone no.
To remotely activate Forced Bypass: ............................................ User Code + [6] + [#]
To remotely check system status:.................................................. [✻]
To end remote phone session: Hang Up or ................................. User Code + [9]
Notes: (1) Check with your installer to see if the Forced Bypass mode has been enabled. (2) When bypassing zones, make sure a confirmation beep sounds for each zone that has been
bypassed.
58
Page 59
USER FUNCTIONS
USER FUNCTIONS
USER FUNCTIONSUSER FUNCTIONS
Remote Services
Your security system may be capable of providing a series of web-based services that allow you to communicate with your security system remotely in a number of ways. These services provide the ability to:
Access to your security system from a computer via website (Remote Access Feature)
Receive e-mail and text message notification of system events (Multi-Mode Feature)
Perform system functions and receive confirmations using text messages (SMS
Feature)
Ask you installer if your system employs a remote services capable device.
59
Page 60
FIRE
FIRE/CO
FIREFIRE
/CO ALARM SYSTEM
ALARM SYSTEM (If Installed)
/CO/CO
ALARM SYSTEM ALARM SYSTEM
General Information
UL
UL
ULUL
General
Your fire alarm system (if installed) is active 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke, heat and/or carbon monoxide detectors will automatically activate your security system, triggering a loud, intermittent sound from the touchscreen. The sound will be interlaced with the voice descriptor, sounding every 15 seconds. A “FIRE” or “CO” message will appear at your touchscreen and remain on until you silence and clear the alarm display.
In Case of Fire
1. Should you become aware of a fire emergency
2. Evacuate all occupants from the premises.
3. If flames and/or smoke are present, leave the premises and notify your local Fire Department
4. If no flames or smoke are apparent, investigate the cause of the alarm. The zone number of
In Case of Carbon Monoxide Alarm
1. If a high level of carbon monoxide is detected you should evacuate all occupants from the
2. From a safe area, contact your security service provider for further instructions.
Silencing a Fire/Carbon Monoxide Alarm
1. Silence the alarm by entering an OFF sequence.
2. To clear the alarm, enter a second OFF sequence.
3 If the touchscreen indicates a trouble condition after the second OFF sequence, check that
4. If this does not remedy the problem, there may still be smoke in the detector. Clear it by
5. When the problem has been corrected, clear the display by entering another OFF sequence.
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed.
to the LYNX Touch and press and hold the panic key and then select the Fire icon. The alarm will sound and an alarm will be transmitted to the central station.
immediately.
the zone(s) in an alarm condition will appear at the touchscreen.
premises and immediately move to a spot where fresh air is available, preferably outdoors.
smoke detectors are not responding to smoke- or heat-producing objects in their vicinity. Should this be the case, eliminate the source of heat or smoke.
fanning the detector for about 30 seconds.
before
your detectors sense the problem, go
60
Page 61
FIRE
FIRE/CO
FIREFIRE
/CO ALARM SYSTEM
ALARM SYSTEM
/CO/CO
ALARM SYSTEM ALARM SYSTEM
National Fire Protection Association’s
Smoke Detector Recommendations
UL
UL
ULUL
With regard to the number and placement of smoke and heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household. The equipment should be installed as follows: A smoke detector installed outside of each separate sleeping area, in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and excluding crawl spaces and unfinished attics.
In addition, the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages.
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed.
KITCHEN
DINING
LIVING ROOM
BEDROOM
LVNG RM
BASEMENT
BEDROOM
BEDROOM
TO BR
KTCHN
BEDROOM
BEDROOM
BEDROOM
CLOSED
.
DOOR
TV ROOM
BEDROOM
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
GARAGE
61
KITCHEN
LIVING ROOM
DINING
BDRM
BDRM
floor_plan-001-V1
Page 62
FIRE
FIRE/CO
FIREFIRE
/CO ALARM SYSTEM
ALARM SYSTEM
/CO/CO
ALARM SYSTEM ALARM SYSTEM
Emergency Evacuation
UL
UL
ULUL
Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association:
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed.
1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants.
2. Determine two means of escape from each room. One path of escape should lead to the door that permits normal exit from the building. The other should be an alternative escape, such as a window, should your path to that door be unpassable. Station an escape ladder at such windows if there is a long drop to the ground.
3. Sketch a floor plan of the building. Show windows, doors, stairs and rooftops that can be used to escape. Indicate escape routes for each room. Keep these routes free from obstruction and post copies of the escape routes in every room.
4. Assure that all bedroom doors are shut while you are asleep. This will prevent deadly smoke from entering while you escape.
5. Try the door. If the door is hot, check your alternate escape route. If the door is cool, open it cautiously. Be prepared to slam the door if smoke or heat rushes in.
6. When smoke is present, crawl on the ground. Do not walk upright, since smoke rises and may overcome you. Clearer air is near the floor.
7. Escape quickly; don't panic.
8. Establish a place outdoors, away from your house, where everyone can meet and then take steps to contact the authorities and account for those missing. Choose someone to assure that nobody returns to the house many die going back.
BACK DOOR
CLOSET
PORCH
BEDR
2 FLOOR
KITCHEN
BEDROOM
1 FLOOR
BEDROOM
ND
BEDROOM
ST
BACK
FRONT
BATH
BATH
BEDROOM
emerevac
62
Page 63
SYSTEM FUNCTIONS
Testing the System (to be conducted weekly)
Test Mode
The Test mode allows each protection point to be checked for proper operation. When the Walk Test mode is active, the control sounds a single beep every 30 seconds as a reminder that the system is in the Test mode.
NOTE: An alarm message will not be sent to your alarm monitoring company during these tests.
Entering Test Mode
Disarm the system and close all protected windows, doors, etc. The “READY” indicator should be lit.
Testing the System
Arm Away
Program the system
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Ready To Arm
Tools
Settings
BackDelay
5000-100-007-V0
231
5
64
1. With the system in the disarmed state, select the “Tools” icon from the second page of the Home Screen. The system displays the Keypad screen.
2. Enter your 4-digit Master User Code. The system displays the Master User programming screen.
Cancel
Ready To Arm
Events
Clear
Reminders
8
0
97
5000-100-009-V0
3. Select the “Test” icon. The system displays the Test screen.
TestSchedulesDevicesUsers
Slide ShowDate Time
Back
5000-100-070-V0
63
Page 64
SYSTEM FUNCTIONS Testing the System (to be conducted weekly)
Version Number: CA01.00EXX
CRC Number: 0X877D
RF Version Number: 0.44
Walk Test Dialer Test
Walk Test
FAULT ZONES. Open each protected door and window in turn and listen for three beeps from the control, followed by the zones Voice Descriptor, if it is programmed. Identification of each faulted protection point should appear on the display. The display will clear when the door or window is closed.
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice descriptors, if programmed. The identification of the detector should appear on the display when it is activated, and its voice descriptor will be announced (if programmed). The display will clear when no motion is detected. Note that if wireless motion detectors are used, in order to conserve battery life, there is a 3-minute delay between activations.
To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no display), notify your service company.
When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the touchscreen.
Exiting Test Mode
When testing is completed, exit the Walk Test or Dialer Test mode by entering an Off sequence.
NOTE: If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer
Test mode will remain active until exited via an Off sequence.
LYNX Touch SIA Exit/Entry Delay Times
The LYNX Touch SIA will send an event code to the Central Station after entering and after exiting from Test mode.
Ready To Arm
Back
5000-100-076-V0
4. Select the “Walk Test” or “Dialer Test” icon. If Walk Test is selected proceed to Step 5. If Dialer Test is selected proceed to Step 6
5. Walk Test…” is displayed on the system status bar. Fault each zone as described below.
6. If the dialer test is unsuccessful the system will display a Reporter Failure message. Contact your security service provider.
64
Page 65
SYSTEM FUNCTIONS
Maintaining your system
The components of your security system are designed to be as maintenance-free as possible. To make sure that your system is in working condition, do the following:
1. Test your system weekly.
2. Test your system after any alarm occurs (see the TESTING THE SYSTEM section).
Routine Care
Treat the components of your security system as you would any other electrical
equipment. Do not slam sensor-protected doors or windows.
Keep dust from accumulating on the touchscreen and all protective sensors, particularly
on motion sensors and smoke detectors.
The touchscreen and sensors should be cleaned carefully with a dry soft cloth. Do not spray water or any other fluid on the units.
Low Battery Conditions in Wireless Sensors
Each wireless sensor in your system has an internal battery. The system detects low battery conditions in wireless sensors, including smoke detectors, personal emergency transmitter, and the portable wireless keypad, and displays a Battery Low message on the touchscreen, which also beeps. A low battery in a wireless keypad is detected as soon as one of its keys is pressed. In addition, a wireless smoke detector with a low battery also emits a "chirp" sound approximately once every 20–30 seconds, identifying itself as the smoke detector with the weak battery.
NOTE: A low battery message means that battery replacement in the indicated sensor(s) is due within 30
days. In the meantime, a sensor with a low battery is still operational.
To silence Low Battery Warning Tones, enter an Off sequence. The low battery message display will remain on as a reminder. When you replace the weak battery with a fresh one, the sensor will send a "good battery" signal to the control when the sensor is activated (opening/closing of door, window, etc.). To clear the Low Battery message, enter an Off sequence.
When replacing batteries, use only those recommended by your installer.
Alkaline batteries provide a minimum of 1 year of operation, and in most units and applications, provide 2–4 years of service. 3-volt lithium batteries may provide from 4-7 years of operation. Actual battery life will depend on the environment in which the sensor is used, the number of signals that the transmitter in the sensor has had to send, and the specific type of sensor. Factors such as humidity, high or low temperatures, and large swings in temperature may all lead to the reduction of actual battery life in an installation.
65
Page 66
SYSTEM FUNCTIONS Maintaining your system
Changing the LYNX Touch Series System Battery
In the event of an AC power loss, the LYNX Touch Series is powered by a rechargeable, nickel-metal hydride battery pack. The battery pack should be replaced when a “Battery Low message with no zone number is displayed.
NOTE: The battery pack (P/N LYNXRCHKIT-SC or LYNXRCHKIT-SHA) should be changed every four years
and must be replaced by a qualified service technician.
Following battery pack replacement, rechargeable batteries may take up to 48 hours to charge. The Battery Low message may be displayed after one minute, however it should clear within 4 hours or by entering Test Mode.
66
Page 67
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS
SOUND CAUSE ANNOUNCEMENT*
INTERRUPTED
CONTINUOUS
ONE SHORT BEEP (not repeated)
ONE SHORT BEEP (once every 45 secs)
TWO SHORT BEEPS THREE SHORT BEEPS
RAPID BEEPING
SLOW BEEPING
FIRE ALARM (3 beeps) OR CARBON MONOXIDE ALARM (4 beeps)
BURGLARY/AUDIBLE EMERGENCY
ALARM
a. SYSTEM DISARM b. SYSTEM ARMING ATTEMPT WITH AN
OPEN ZONE. c. BYPASS VERIFY a. SYSTEM IS IN TEST MODE b. LOW BATTERY AT A TRANSMITTER c. SYSTEM LOW BATTERY d. FAIL TO COMMUNICATE ARM AWAY armed away [instant] – exit now
a. ARM STAY OR INSTANT b. ZONE OPENED WHILE SYSTEM IS IN
CHIME MODE. a. TROUBLE b. MEMORY OF ALARM a. ENTRY DELAY WARNING b. EXIT DELAY WARNING
Additional Announcements:
The system will announce the following primary messages, depending on the systems status at the time:
DisarmedReady to Arm [check system]
Disarmed [not ready to arm]
Armed [away] [stay] [instant] [check system] [exit now]
The system will announce the following secondary messages, depending on the system’s status at the time:
Fire Alarm + zone voice descriptor
Alarm + zone voice descriptor
Carbon Monoxide Alarm + zone voice descriptor
Carbon Monoxide Fault + zone voice descriptor
Fire Fault + zone voice descriptor
Fault + zone voice descriptor Alarm + zone voice descriptor
Low Battery + zone voice descriptor Fire Fault + zone voice descriptor
System Low Battery
Check System
AC Loss
Zones Bypassed
Chime
Note: If there are no secondary messages, the primary status messages will be announced.
fire alarm + zone voice descriptor OR Carbon monoxide alarm + zone voice descriptor (Voice descriptor is interlaced with the sounder and sounds every 45 seconds) alarm + zone voice descriptor (Voice descriptor is interlaced with the sounder and sounds every 45 seconds) a. disarmed–ready to arm b. disarmed–not ready to arm
c. zones bypassed a. no announcement b. low battery + zone voice descriptor c. system low battery d. check system
a. armed stay [instant] – exit now b. zone voice descriptor
a. fault + zone voice descriptor b. fire alarm or alarm + zone voice descriptor a. disarm system now b. armed [away] [instant] – exit now
67
Page 68
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS
System Displays
The following icons will be displayed on the Home screen along with specific zone status information (if applicable) to indicate system status.
DISPLAY DEFINITION
AC Loss
Alarm (intrusion)
Armed Away
Armed Stay
Battery Low
Check Zones
CO Alarm
Disarmed Not Ready to Arm
Disarmed Ready to Arm
Reporter Failure
Cover Tamper
Trouble
DISPLAY DEFINITION
Door Open
Window Open
Exit Active
Fire
Flood
Glass Break
Medical Alarm
Motion
Temperature
90 RF Jam
94 Phone Line Cut
103 Comm. Trouble
68
Page 69
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS
Zone Status Icons
The following icons may be displayed on the Zone Status screen.
ICON
DEFINITION
Alarm
Fault (Yellow)
Ready
ICON
LED Meanings
ARMED LED (Red): ON = System armed OFF = System disarmed Blinking = System armed, but a fault exists or alternating with READY LED
READY LED (Green): ON = System disarmed, ready to arm Blinking = System disarmed, not ready to arm (a fault exists) or alternating
Note: When the system is armed, the READY LED turns off.
when AVM (VOX or Talk) or speaker phone mode is active.
with ARMED LED when AVM (VOX or Talk) or speakerphone mode is active.
DEFINITION
Trouble (red)
Bypass
69
Page 70
Regulatory Agency Statements
Federal Communications Commission (FCC) Part 15
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Industry Canada (IC)
This device complies with RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une reception indésirable.
70
Page 71
Regulatory Agency Statements
TELEPHONE/MODEM INTERFACE
Federal Communications Commission (FCC) Part 68
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains the FCC registration number and Ringer Equivalence Number (REN). You must provide this information to the telephone company when requested.
This equipment uses the following USOC jack: RJ31X This equipment may not be used on telephone-company-provided coin service. Connection to party lines is subject to state tariffs.
This equipment is hearing-aid compatible.
Industry Canada
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment meets
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together, This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves but should contact appropriate electric inspection authority, or electrician, as appropriate.
AVIS: l’étiquette dIndustrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, dexploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère nassure toutefois pas que le matériel fonctionnera à la satisfaction de lutilisateur.
Avant dinstaller ce matériel, lutilisateur doit sassurer quil est permis de le raccorder aux installations de lenterprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da raccordement. L’abonné ne doit pas oublier quil est possible que la conformité aux conditions énoncées ci-dessus n’empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur. Lentreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à la suite de réparations ou de modifications effectuées par lutilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, lutilisateur doit sassurer que tous les fils de mise à la terre de la source denergie électrique, de lignes téléphoniques et des canalisations deau métalliques, sil y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales.
Avertissement : L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un service dinspection des installations électriques, ou à un électricien, selon le cas.
Ringer Equivalence Number Notice: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. AVIS : Lindice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison dune interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme dindices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.
WARNING: The LYNX Touch must be installed to provide a separation distance of at least 7.8 in (20 cm) from
!
all persons and not co-located or operated in conjunction with any other transmitter
RF Exposure
.
– 71 –
Page 72
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X (CA38A in Canada) telephone wall jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the control/communicator. Doing so will result in the loss of your phone lines. If the regular phone works correctly after the control/communicator has been disconnected from the phone lines, the control/communicator has a problem and should be returned for repair. If upon disconnection of the control/communicator, there is still a problem on the line, notify the telephone company that they have a problem and request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs.
72
Page 73
OWNER'S INSURANCE PREMIUM CREDIT REQUEST
This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit.
A. GENERAL INFORMATION:
Insured's Name and Address:
Insurance Company: Policy No.:
LYNX Touch Series _________________________________________________ Other
Type of Alarm: Burglary Fire Both
Installed by: Serviced by: Name Name
Address Address
B. NOTIFIES (Insert B = Burglary, F = Fire)
Local Sounding Device Police Dept. Fire Dept.
Central Station Name: _______________________________________________________________________________
Address:
Phone:
C. POWERED BY: A.C. With Rechargeable Power Supply
D. TESTING: Quarterly Monthly Weekly Other
(continued on other side)
73
Page 74
OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.)
E. SMOKE DETECTOR LOCATIONS
Furnace Room Kitchen Bedrooms Attic
Basement Living Room Dining Room Hall
F. BURGLARY DETECTING DEVICE LOCATIONS:
Front Door Basement Door Rear Door All Exterior Doors
1st Floor Windows All Windows Interior Locations
All Accessible Openings, Including Skylights, Air Conditioners and Vents
G. ADDITIONAL PERTINENT INFORMATION:
Signature: Date:
74
Page 75
SERVICING INFORMATION
Your local Honeywell dealer is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable.
Your local Honeywell dealer is:
Name:
Address:
Phone:
75
Page 76
WARNING!
THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example:
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device.
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or
provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can decrease.
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 10 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.
76
Page 77
INDEX
A
Alarm Cancelled ........................... 7, 23, 24
Alarm Exit Error .................................... 23
Alarms ........................................................ 8
Armed Indicator................................. 17, 22
Audible Emergency/Audible Alarm ........ 29
Auto Stay Feature ............................... 7, 19
Away Mode........................... 6, 9, 20, 22, 23
B
Babysitter Code ........................... 18, 20, 33
Battery...... 14, 17, 60, 61, 62, 64, 65, 66, 67
Battery Conditions .................................. 65
Battery Low ............................................. 66
Battery Pack ............................................ 66
Burglary Abort Window ............................ 7
Burglary Protection ......................... 5, 6, 12
Burglary Protection .................................. 6
Bypass a Zone ............................................ 9
Bypassing Protection Zones ...... 6,27,28, 33
C
Central Monitoring Station................ 8, 76
Checking System Status .......................... 9
Chime Mode ............................... 6, 9, 10, 31
Clock/Calendar............................ 42, 43, 44
D
Device Activation ....................................... 6
Device Programming Option................... 45
Devices.................. 2, 6, 9, 20, 45, 49, 71, 76
Dialer Test ............................................... 64
Disarm .... 7, 8, 9, 12, 18, 20, 22, 23, 24, 25,
33, 55, 67
Disarming The System and Silencing
Burglary Alarms................................. 25
Duress Code, 33
E
E-Mail Events ..........................................45
Entering Test Mode ................................. 63
Entry Delay ............6, 12, 18, 20, 22, 23, 24
Exit Alarms ......................................... 7, 23
Exit Delay................................................. 23
Exit Time Restart-Exit Delay
Restart/Reset .........................................7
Exit/Entry Delays ......................................7
F
False Alarm Prevention Features....... 7, 33
False Alarms ........................................7, 23
Features...................................................... 5
Fire Alarm ..............................14, 26, 29, 67
Fire Alarm System................................... 60
Fire Protection ........................................... 6
H
Home Screen ..11, 15, 19, 21, 22, 25, 27, 31
Home (Cancel) Key ................................. 15
L
LCD Display ............................................. 15
Liquid Crystal Display ............................15
M
Master Menu ........................................... 16
Master User.......................................... 8, 33
Master User Code16, 33, 34, 35, 37, 42, 45,
49, 52, 63
Memory of Alarm ..................................... 67
Menu ..................................................... 9, 15
Menu Screens ........................................... 16
Message Center....................5, 9, 12, 16, 39
Microphone......................................... 12, 39
Multi-Mode Feature.................................59
N
Navigation Keys....................................... 15
No Delay ................................................... 22
77
Page 78
P
Panic Key ....................................... 5, 29, 60
Personal Emergency/Aux. Alarm ........... 29
Phone Control ............................................ 5
Q
Quick Arm ...................................... 9, 18, 20
Quick Exit ................................................ 22
R
Ready Indicator................ 11, 17, 18, 20, 25
Ready LED ............................................... 17
Real-Time Clock......................................... 5
Rechargeable, Nickel-Metal Hydride
Battery Pack ........................................ 66
Record a Message ...................................... 9
Reminder Feature.................................... 52
Remote Access Feature ........................... 59
Remote Interactive Phone Capability .... 57
Remote Phone Control............... 3, 5, 57, 58
Remote Services....................................... 59
Restart Exit Delay ..................................... 9
Restarting Exit Delay.............................. 23
S
Schedules.............................. 6, 9, 16, 49, 51
Scheduling Feature ............................ 6, 49
Security Codes ....................................... 5, 8
Security Functions..................................... 9
Servicing Information.............................. 75
Silence Alarm....................................... 9, 25
Silencing a Fire/Carbon Monoxide Alarm..
.............................................................. 60
Silencing Low Battery Warning Tones .. 65
Silent Emergency/Silent Alarm .............. 29
Smoke Detectors .......... 6, 60, 61, 64, 65, 76
SMS Feature ............................................ 59
Speaker Phone ......... 5, 9, 10, 11, 12, 55, 69
Status Area .............................................. 15
Stay Mode................................... 6, 9, 18, 22
System Adjustments................................ 41
System Battery ........................................ 66
System Status .......................................... 17
T
Test Mode ....................................... 9, 63, 64
Time and Date................................ 9, 16, 42
Touchscreen Control ...................... 5, 10, 11
Triggers ....................................................45
Two-Way Voice ....................................... 5, 8
U
Unrestricted Menu................................... 16
User Access.......................33, 45, 46, 47, 48
User Codes............................................ 5, 33
V
Voice Dialog................................................ 8
Volume Adjustment ................................... 9
Volume Level................................ 10, 17, 41
W
Walk Test ...........................................63, 64
Wireless Keypads....................................... 5
Wireless Sensors ...................................... 65
Z
Zones ......................5, 6, 8, 17, 19, 27, 28, 64, 67
78
Page 79
TWO YEAR LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Communications business (“Seller), 2 Corporate Center Drive, Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at its discretion, reflect the warranty period as commencing at invoice date. Except as required by law, this Limited Warranty is only made to Buyer and may not be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at its sole option and as the exclusive remedy hereunder, free of charge, any defective products.
Seller shall have no obligation under this Limited Warranty or otherwise if the product: (i)is improperly installed, applied or maintained; (ii)installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than
the Seller/Sellers Authorized Service/Repair Center;
(iii)damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or
the like; or
(iv)defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes
unrelated to defective materials or workmanship, or failures related to batteries of any type used in connection with the products sold hereunder.
Exceptions to Warranty With Respect to Honeywell Products listed below:
Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above limited warranty for a period of five (5) years from the manufacture date code.
EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY
THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY (i) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY WAY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLERS OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Sellers agents), specifications, samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in connection with the Buyers order are for the sole purpose of identifying the Sellers products and shall not be construed as an express warranty or condition. Any suggestions by Seller or Sellers agents regarding use, applications, or suitability of the products shall not be construed as an express warranty or condition unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a guarantee that such will not occur or will not cause or lead to personal injury or property loss. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON ANY CLAIM AT ALL INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether directly or indirectly for any loss or damage with respect to the products it sells, regardless of cause or origin, its maximum liability shall not in any case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Seller. Should your product become defective during the warranty, please contact your installer to facilitate repair or replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace any defective product under warranty with new, refurbished, or remanufactured product.
79
Page 80
Ê800-06894}Š
800-06894 1/11 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2011 Honeywell International Inc.
www.honeywell.com/security
Loading...