Honeywell 800-06894 User Manual

LYNX Touch
Security System
User Guide
Ready To Arm
Arm Away
ARMED READY
Arm Stay
10:18 AM June 8, 2010
Zones
Message
System
Phone
MoreDelay
800-06894 1/11 Rev. A
Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's control or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty. When you purchase devices that have been manufactured or approved by Honeywell, you acquire the assurance that these devices have been thoroughly tested to ensure optimum performance when used with your Honeywell security system.
– 2 –
TABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
SYSTEM OVERVIEW.................................................................................................................................. 5
Features...................................................................................................................................................5
General Operation...................................................................................................................................6
Quick View of System Functions............................................................................................................9
About the Touchscreen Control ............................................................................................................10
Touchscreen Control Definitions ..........................................................................................................11
About the Display and Indicators.........................................................................................................13
Navigating Menus .................................................................................................................................15
SECURING THE PREMISES ..................................................................................................................17
System Status........................................................................................................................................17
Arming the System................................................................................................................................18
Entry/Exit Delays..................................................................................................................................23
Disarming the System...........................................................................................................................25
Bypassing Protection Zones..................................................................................................................27
Panic Keys .............................................................................................................................................29
Chime Mode...........................................................................................................................................31
Voice Mode.............................................................................................................................................32
USER FUNCTIONS ................................................................................................................................... 33
User Access............................................................................................................................................33
View Events...........................................................................................................................................37
Message Recording and Playback.........................................................................................................39
System Adjustment ...............................................................................................................................41
Clock/Calendar ...................................................................................................................................... 43
Programming Devices ...........................................................................................................................45
Scheduling User Interface ....................................................................................................................49
Reminders..............................................................................................................................................52
Speaker Phone Feature.........................................................................................................................55
Remote Phone Control Feature ............................................................................................................57
Remote Services ....................................................................................................................................59
FIRE/CO ALARM SYSTEM......................................................................................................................60
General Information..............................................................................................................................60
National Fire Protection Association’s Smoke Detector Recommendations.......................................61
Emergency Evacuation .........................................................................................................................62
SYSTEM FUNCTIONS ..............................................................................................................................63
Testing the System................................................................................................................................63
Maintaining Your System.....................................................................................................................65
Congratulations on your ownership of a Honeywell Security System. You have made a wise decision in choosing it, for it represents the latest in security protection technology today. Honeywell is the world's largest manufacturer of security system and millions of premises are protected by Honeywell products.
3
TABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS ...................................................................67
System Displays ....................................................................................................................................68
Zone Status Icons ..................................................................................................................................68
Regulatory Agency Statements....................................................................................................................69
FCC STATEMENTS ..................................................................................................................................70
OWNER’S INSURANCE PREMIUM CREDIT REQUEST..................................................................73
LIMITATIONS OF THIS ALARM SYSTEM..........................................................................................76
INDEX ..........................................................................................................................................................77
TWO YEAR WARRANTY ..........................................................................................................................79
4
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Features
General Information
This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a touchscreen control for system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning. In addition, optional wireless keypads may have been installed to allow you to control the system away from the touchscreen control. The system may also be used as a speaker phone. The system monitors protection zones and system status, displays appropriate information on the touchscreen display, and initiates appropriate alarms. Your system may also have been programmed to automatically send alarm or status messages over the phone lines or via the cellular/GSM network or the internet to a central alarm monitoring station, and may also be capable of two-way voice communication with the central station.
The user features of this security system are listed below. Ask your installer which features have been programmed for your system.
STAY and AWAY arming modes: By using these modes you can protect either the
perimeter only, or the entire premises.
Panic key functions: A designated key allow you to manually activate fire, medical
emergency, or silent police alarms. Refer to the PANIC KEYS section for detailed information.
Follow me reminder announcements: Allows the panel to dial a number that you have
specified, at a programmed time and day and deliver a message programmed by your installer.
Real-time clock: Touchscreen displays current date and time. Refer to the
CLOCK/CALENDAR section for procedures for setting the time.
Message center: The system allows recording and play back of brief messages. Refer to
the RECORDING/PLAYBACK MESSAGES section for procedures.
Two-way voice: Allows the central station to listen, talk to or conduct two-way
conversations with individuals on the premises Refer to the TWO-WAY VOICE section for detailed information.
Phone Control: Provides a remote interactive phone capability that permits access to the
security system from any off-site touch-tone telephone. Refer to the Remote Phone Control Feature section for detailed information.
Speaker Phone Operation: The system is capable of operating as a speaker phone
allowing hands free telephone conversation.
Security Codes: The system is capable of supporting an Installer code, Master user code
and 14 additional User codes including Babysitter and Duress codes. Refer to the SECURITY CODES section for detailed information.
5
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW General Operation
Device activation: Allows you to send Follow-Me or e-mail messages, as a result of a
system event such as an alarm or trouble condition. Refer to the DEVICES section for detailed information.
Scheduling feature: Allows you to schedule the automatic activation or deactivation of
program events (e.g. alarm clock, reminder, and latch key). Refer to the SCHEDULES section for detailed information.
Zones
Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs.
Fire Protection
The fire protection portion of your security system (if used) is always active and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from the premises.
Carbon Monoxide
The carbon monoxide (CO) portion of your security system (if used) is always active and will sound an alarm if a CO condition is detected. Refer to the FIRE ALARM SYSTEM section for more information.
Burglary Protection
Your system provides two modes of burglary protection: STAY and AWAY. STAY mode protects the perimeter only, allowing you to freely move inside the premises. AWAY mode protects the entire system. Both modes provide an entry delay time that allows you to reenter the premises without setting off an alarm. For additional security, you can turn the entry delay off when arming the system. Refer to the ARMING THE SYSTEM section. The system also allows you to bypass selected zones before arming the system, if desired. Refer to the BYPASSING PROTECTION ZONES section. The system also provides a CHIME mode, for alerting users to the opening of protected doors and windows while the system is disarmed.
You must arm the burglary protection portion of your system before it will sense burglary alarms. Refer to the ARMING THE SYSTEM section for detailed procedures and information.
6
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
General Operation
LYNX Touch SIA False Alarm Prevention Features
Many false alarms are caused by simple accidents, like forgetting to close a door when you leave. The LYNX Touch SIA includes several features that help prevent false alarms and some of these are optional or programmable. Although turning off some of these features may provide additional security, it may also increase the chance of false alarms. Your installer can help you decide whether to use the features or not. The following provides a brief explanation of the features included with your security system that help prevent false alarms from occurring, and what you should do if such alarms occur.
Exit/Entry Delays: Your security system has been programmed with delay times that allow you to
exit the premises after arming, and to disarm the system upon entry, before an alarm occurs. If you leave the premises too late when exiting, or disarm too late when arriving home, it will cause a false alarm. If an alarm occurs, you should disarm the system immediately, and wait for your monitoring company to call you.
Exit Alarms: Leaving the premises and forgetting to close the door is a common cause of false
alarms. The security system will sound an alarm, and display Exit Error. The security system provides extra time for you to disarm the system before dialing your monitoring company. Disarming the system immediately may prevent a call to your monitoring company.
Exit Time Restart-Exit Delay Restart/Reset: If you leave the premises and enter again before the
exit delay has expired, the system will restart the exit time giving you more time to leave. If there are less than 10 seconds left to exit, the system will sound fast beeps, indicating an alarm will occur soon if you fail to exit or disarm immediately. If this occurs, disarm the system and arm it again when you are ready to leave. The Exit Delay can also be restarted by pressing the RESTART Icon.
Auto Stay Feature: If you arm the system in the “AWAY mode from the controls keypad or an RF
keypad but no one exits, the alarm system will automatically change to the “STAY” mode. This will prevent you from tripping alarms by remaining on premises. Disarm the system and arm away again when you are ready to leave.
Burglary Abort Window: Your security system has a delay between the time a burglary alarm
sounds, and the time the monitoring company is called. This delay gives you time to disarm the security system before the alarm is reported to the monitoring company. This delay is factory preset at 30 seconds, but may be increased or decreased by your installer.
False Alarms: If a burglary or fire alarm condition occurs and the system has been disarmed, the
keypad will display Alarm Cancelled. If this was a false alarm, wait for the monitoring company to call you. They will verify your security code or password and prevent them from calling emergency personnel to respond to a false alarm.
7
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW General Operation
Security Codes
At the time of installation, you were asked to provide a personal 4-digit security or “Master User code. You must enter the user code when arming and disarming the system, and when performing other system functions. As an additional security feature, other users who do not need to know your code can be assigned up to 14 different security codes. Refer to the SECURITY CODES section for procedures on adding security codes to the system.
Alarms
When an alarm occurs, the LYNX Touch internal sounder will sound for about 15-seconds, and the touchscreen displays the zone(s) causing the alarm. After 15-seconds, the internal sounder stops temporarily and voice announcements of the zones in alarm begins. When these zones have been announced, the internal sounder sounds again and the cycle repeats itself, until the system is disarmed or until alarm bell timeout occurs. If your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, simply disarm the system. The zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the DISARMING THE SYSTEM section for information about clearing the memory of alarm display
Two-Way Voice Feature
The control supports voice dialog between an operator at the central station and an individual at the premises. This feature allows the central station to listen, talk to or conduct a two-way conversation with an individual(s) at the premises and allows the operator to gather information about the nature and location of the alarm that may be helpful in responding to police or rescue departments. If the Two-way Voice Feature has been programmed and an alarm condition is detected, the system sends an alarm message to the central station. After acknowledgement is received, a listen in to follow message is sent to the central station. In response to this message, the central station operator can enter commands that allow him to initiate a 5-minute voice session.
If a subsequent zone is violated during a voice session, the system will terminate the session and process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs will alternately blink in the Talk and VOX Modes but not during Listen Mode.
8
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONSQUICK VIEW OF SYSTEM FUNCTIONS
SECURITY FUNCTIONS
Checking system status: ............................................. Select “System” icon.
To arm in STAY mode: .............................................. Select “Stay” icon then enter Code.
To restart exit delay: ................................................... Select “Restart Exit Delay” icon.
To arm in AWAY mode: ............................................. Select “Away” icon or depress “Away” key then enter
Code.
To arm INSTANT: ...................................................... Set “Delay” to ”Instant” . Select “Stay” or “Away” icon
or “Away” key then enter code.
To arm if Quick Arm* is active: .................................... Select “Stay” or “Away” icon or “Away” key followed
by Quick Arm tab on the touchscreen.
*
User code is not required if Quick Arm is active.
To disarm system and silence alarms:......................... Depress “Off’” key or “Disarm” icon and enter Code
Note: During Entry Delay or when an Alarm Condition exists, the LYNX Touch can be disarmed by entering the User
To bypass a zone(s): .................................................. Select “Zones” icon
To turn Chime mode on or off: .................................... Select “Settings” icon
Code. Entering the OFF key is not required
MESSAGE CENTER
To record a message: ................................................. Select “Message” icon
VOLUME ADJUSTMENT
To adjust volume: ........................................................Select “Settings” icon
To restore/unmute user announcements: .................... Select “Settings” icon
SPEAKER PHONE OPERATION
To enter speaker phone mode:.................................... Select “Phone” Icon
To enable/disable (toggle) ringer: ................................Select “Settings” icon
OTHER FUNCTIONS (accessible to the Master User only)
To set the time and date: ............................................. Select “Date Time” icon (on Master User Menu)
To set scheduling:........................................................ Select “Schedules” icon (on Master User Menu)
To activate/deactivate devices:.................................... Select “Devices” icon (on Master User Menu)
To add/delete a user code* (except Master Code):......Select “Users” icon (on Master User Menu)
* Only the master code can be used to add or delete another user code.
To turn Test mode On or Off:....................................... Select “Test” icon (on Master User Menu)
To view system events:................................................Select “Events” icon (on Master User Menu)
To program or delete “Follow Me” Reminders: ............Select “Reminders” icon (on Master User Menu)
9
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW About the Touchscreen Control
General
**IMPORTANT**
If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
The touchscreen icons and keys allow you to control all system functions. Additionally, the touchscreen display shows the zone and description of all system occurrences. When the speaker phone mode is active, a full-function telephone keypad is displayed on the touchscreen.
The system also features a built-in sounder, which will sound during alarms and troubles and a built-in speaker announces system status. Additionally, the system "beeps" during certain system functions, such as during entry/exit delay times, in Chime mode, and when depressing any of the keys (to acknowledge the key press).
The voice announcement volume is adjustable, however the “beeps” that sound in response to alarms always sound at the maximum volume level. All other “beeps” (trouble, chime, exit/entry, etc) can be set to either low or high volume.
ARMED READY
10
5000-100-002-V0
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Touchscreen Control Definitions
1
9
2
3
ARMED READY
8 4
7 6 5
Note: The system functions described below are for reference only and require additional key entries to
activate.
1. DISPLAY WINDOW: Color Liquid Crystal Display (LCD). Displays system status icons, time,
system status information, user menus and the virtual keypad.
2. READY Indicator (LED): (GREEN) When lit, indicates system is ready to be armed; blinking
indicates system is not ready (a zone is open). Blinks once per second when AVM (VOX or Talk) or speaker phone mode is active.
3. HOME Key: Used to exit from a screen or return to the home screen.
4. Speaker: Source of audible internal warning and confirmation sounds, status announce-
ments, as well as alarms (see "Summary of Audible Notifications").
5000-100-051-V0
11
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW Touchscreen Controls Definitions
5. OFF (Disarm) KEY: Initiates the disarm process and causes a keypad to be displayed on
the touchscreen. Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected.
6. AWAY KEY: Completely arms both perimeter and interior burglary protection for backup
protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires.
7. PANIC Key: When depressed for 4 seconds, the virtual panic icons are displayed on the
touchscreen. MICROPHONE: Used to record personal messages via the Message Center, and for two-
8. way voice and speaker phone operation.
9. ARMED Indicator (LED): (RED) Lit when the system has been armed (STAY, AWAY). Blinks when armed and fault exists, or once per second when AVM (VOX or Talk) or speaker phone mode is active.
LED Meanings
ARMED LED: ON = System armed
(Red) OFF = System disarmed Blinking = System armed, and an alarm is in progress or was previously. Blinking alternately with READY LED = speaker phone mode is active READY LED: ON = System disarmed, ready to arm (Green) OFF = System armed
Blinking = System disarmed, not ready to arm (a fault exists) Blinking alternately with ARMED LED = speaker phone mode is active.
12
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Display Definitions
ICON TEXT
Ready to Arm
Armed Away
Armed Stay
Exit Now 28 Seconds
Alarm
About the Display and Indicators
DEFINITION
Displayed along with the the text READY TO ARM when system is Disarmed and ready to arm.
Armed Away is displayed along the top of the screen. An armed away icon along with Armed Away is displayed after the exit delay expires.
Armed Stay is displayed along the top of the screen. An armed stay icon along with Armed Stay is displayed after the exit delay expires.
“Armed Stay – Exit Now” or “Armed Away – Exit Now” is displayed in a red band along the top of the screen. An exit icon along with “Exit Now” and the time remaining (i.e.; “28 Seconds”) is displayed during the exit delay.
when the system is armed in the Stay mode. The text “Armed: Stay Exit Now Once the exit delay expires Armed: Stay is displayed along with the Home Screen.
Note: Display alternates with ARMED STAY icon and text
Alarm is displayed in a red band along the top of the screen. An alarm (bell) icon along with “Alarm” is displayed alternately with the Zone that has caused the alarm.
OR
Fault (Zone No.& Description)
Not Ready To Arm – Fault is displayed in a yellow band along the top of the screen. An open windowor door icon along with the zone descriptor and “Window” or “Door” is displayed when a window or entry/exit fault has been detected.
OR Displayed alternately with the alarm (bell) icon and “Alarm”. Alarm is also displayed in a red band along the top of the
screen.
13
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW About the Display and Indicators
ICON TEXT
Fire OR Fire Alarm 95 Fire
Alarm 96 Medical
Alarm 99 Police
CO Alarm
Cover Tamper
Reporter Failure
Low Battery
90 RF Jam
94 Phone Line Cut
AC Loss
DEFINITION
The fire icon is displayed with alternating text “Fire” and “Fire Alarm 95 Fire”. “Fire Alarm is also displayed in a red band along the top of the screen.
The Medical icon isplayed when a medical alarm is activated. Alarm is also displayed in a red band along the top of the
screen. (If programmed for display by your installer) The alarm (bell) icon when a burglary alarm is activated.
Alarm is also displayed in a red band along the top of the screen.
(If programmed for display by your installer) Displayed alternately with the alarm (bell) icon when a CO
alarm is activated. Alarm is also displayed in a red band along the top of the
screen. A check system icon along with Cover Tamper is displayed
when a cover tamper has been detected. Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen.
The system has identified a problem with the telephone dialer.
Not Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen. A low battery icon along with Low Battery is displayed when the systems backup battery power is low.
Appears when the system has detected an RF jamming condition or excessive interference.
Appears when the system has detected a loss of telephone service.
Displayed when the system has lost AC power. Ready To Arm – System Trouble is displayed in a yellow band along the top of the screen.
14
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Navigating Menus
LCD Display
LYNX Touchs Liquid Crystal Display (LCD) touch-screen displays variable icons and text on screens. The screen displays status icons and associated text, the current time, system
status information and menu choices. The system status is displayed in a colored band along the top of the screen. The band color is variable and will change between red, yellow and green as the system status changes. The Menu area includes a list of commands, or choices that apply to the current selection. The status area provides information about various system events. A Home Screen is displayed whenever power is applied to the system. In addition the green ‘READY” LED will be lit.
SYSTEM
STATUS
SYSTEM/ZONE
STATUS
Ready To Arm
Zones
System
Arm Away
Arm Stay
10:18 AM June 8, 2010
Message
Phone
MoreDelay
5000-100-054-V0
LYNX Touch Home Screen (page 1)
Navigation Keys
Navigating through the screens is accomplished by lightly touching the menu item on the touch-screen. Once activated, the control will take you to the next screen. Selecting the
Home (cancel) key or the
2” Key will return you to the home screen at any time unless
System Programming mode is active.
Note: You may find it convenient to adjust the volume setting before entering the Program (Tools) Mode.
This will allow you to clearly hear the feedback announcements or system beeps in the Programming Mode, of the systems built-in speaker. To adjust the volume, select “More” on the home Screen and then select “Settings”. Adjust the volume using the slide shown on the Settings screen and then select Save to accept.
15
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW Navigating Menus
Menu Screens
System Status is displayed at the top of each screen. The time and date are displayed at the bottom of the Home Screen.
Menus
Unrestricted Menu
The first page of the Home Screen provides access to an Unrestricted Menu displays the system status and eight selection icons or “buttons”.
1. Zones – Provides access to Zone information and options.
2. System – Provides information about system status.
3. Arm Away – Used to Arm the system in Away mode.
4. Arm Stay – Used to Arm the system in Stay mode.
5. Message – Provides access to Message Center.
6. Phone – Provides access to Speaker Phone mode (if programmed).
7. Delay/Instant – Used to toggle between exit delay and instant arming options.
8. More – Advances system to second page of the Home Screen.
The second page of the Home Screen displays the system status in and seven options.
1. Tools – Provides access User Programming Menus (Master User Code required for
access).
2. Arm Away – Used to Arm the system in Away mode.
3. Arm Stay – Used to Arm the system in Stay mode.
4. Settings – Provides access to various touchscreen functions including Brightness,
Contrast, Volume, Voice, Chime and Ringer.
5. Delay/Instant – Used to toggle between exit delay and instant arming options.
6. Back – Returns system to first page of the Home Screen.
Master Menu
The User Menu provides access to User configurable features and displays eight options. Entering the Master User Code is required to access the Master menu.
1. Users – Allows Master User to add or remove User Codes
2. Devices – Allows Master User to program output triggers.
3. Schedules – Allows Master User to program schedules
4. Test – Allows Master User to Test the system
5. Date Time – Used to program date and time.
6. Events – Allows Master User to view system events
7. Reminders – Allows Master User to add or remove local and Follow Me reminders.
8. Slide Show – Allows Master User to select a slide show for use as a screensaver.
9. Back – Returns system to first page of the Home Screen.
16
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
System Status
General Information
Before arming your system, all protected doors, windows, and other protection zones must be closed or bypassed (see the BYPASSING PROTECTION section).
READY LED: The green READY indicator on the control will be lit if the system is ready to
NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the
current state of the system.
Depending on the current state of the system the following phrases may be heard:
fire alarm [zone voice descriptors] carbon monoxide alarm [zone voice descriptors]
alarm [zone voice descriptors] fire fault [zone voice descriptors]
carbon monoxide fault [zone voice descriptors] fault [zone voice descriptors] low battery [zone voice descriptor] system low battery check system AC loss zones bypassed chime
VOLUME LEVEL: The volume level of system announcements can be increased or decreased. Refer to the MESSAGE RECORDING/PLAYBACK section for the procedure.
System Can Be Armed
The READY LED will be lit steadily once all protection zones have been closed or bypassed. You may now arm the system.
be armed. If blinking, the system is not ready.
17
SECURIN
SECURING THE PREMISES
SECURINSECURIN
G THE PREMISES
G THE PREMISESG THE PREMISES
Arming the System
Arming in Stay Mode
Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the control should be lit if the system is ready to be armed. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the designated entrance door without causing an alarm, but they must disarm the system within
the entry delay period or an alarm will occur. you do not need to enter the security code to arm the system. The security code must always be used to disarm the system, however.
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm the system. In addition, if the system is armed by pressing via Quick-Arming, neither the Babysitter Code nor Installer Code can disarm the system.
Ready To Arm
Zones
System
If Quick Arm was programmed by the installer,
1. Select the Arm Stay icon, the system will beep once and display a keypad.
Arm Away
Arm the system in Stay mode
Enter Code:
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Cancel
Message
Clear
Phone
MoreDelay
5000-100-006-V0
2. Enter a valid User Code.
231
OR If Quick Arm has been enabled, select the
564
Quick Arm icon.
The system will beep three times and
897
0
5000-100-137-V0
announce delay screen will be displayed. If programmed the display will count down the time remaining in the exit delay.
Note: If a valid user code is not entered or the
Confirm icon has not been selected within 10 seconds, the system will return to the
home screen and it will not be armed.
Armed Stay Exit Now
. The exit
– 18 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Armed: Stay
3. At the end of the exit delay the system will announce
Armed Stay
and
display the Armed Stay screen.
Disarm
10:18 AM June 8, 2010
Zones
Message
System
Phone
More
5000-100-056-V0
If an invalid User Code is entered, the system will return to the home screen.
Auto Stay Feature
If this feature is enabled by installer, the LYNX Touch SIA, when armed AWAY from the control’s keypad or a Wireless Keypad, switches to the STAY mode if the Exit Time expires and no exit has been made.
NOTE: If the exit route entry/exit sensor is in a check condition or has been bypassed it will result in a loss of interior
protection because the alarm system will arm STAY in this case. Consult with your installer for servicing of the entry exit zones or to turn off this feature if a check condition on entry exit zones occurs.
19
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Arming the System
Arming In Away Mode
Use this mode when no one will be staying on the premises. Close all protected perimeter windows and doors before arming. The green READY indicator on the control should be lit if the system is ready to be armed. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises, when infrared detection devices are used. You may leave through a designated entrance door during the exit delay period without causing an alarm. You may also re-enter through the entrance door, but you must disarm the system within the entry delay period or an alarm will occur. the security code to arm the system. The security code must always be used to disarm the system, however.
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm the system. In addition, if the system is armed by pressing via Quick-Arming, neither the Babysitter Code nor Installer Code can disarm the system.
If Quick Arm was programmed by the installer, you do not need to enter
Ready To Arm
1. Select the Arm Away icon, the system will beep once and display a keypad.
Zones
System
Arm Away
Arm the system in Away mode
Enter Code:
Cancel
Arm Stay
10:18 AM June 8, 2010
Ready To Arm
Message
Clear
Phone
MoreDelay
5000-100-006-V0
2. Enter a valid User Code.
231
OR If Quick Arm has been enabled, select the
564
897
0
5000-100-053-V0
Quick Arm icon.
The system will beep two times and announce
Armed Away Exit Now
. The exit delay screen will be displayed. If programmed the display will count down the time remaining in the exit delay in seconds.
Note: If a valid user code is not entered or the Confirm
icon has not been selected within 10 seconds, the system will return to the “home” screen and it will not be armed.
20
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Armed: Away
Disarm
10:18 AM June 8, 2010
Zones
Message
System
Phone
More
5000-100-057-V0
If an invalid User Code is entered, the system will return to the home screen.
3. If “Exit Warning” has been enabled, the system will continue to beep throughout the exit delay. Rapid beeps will sound for the final 10 seconds of the delay period. At the end of the exit delay the system will announce
Armed Away
and displays the
Armed Away screen.
21
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Arming the System
Arming the System with no delay (Instant)
Use Instant with Stay mode when you are staying home and do not expect anyone to use the entrance door.
Use Instant with Away mode when the premises will be vacant for extended periods of time such as vacations, etc.
When armed with “Instant”, the control beeps twice, or beeps continuously if exit warning has been programmed for your system, and displays the Armed Stay Instant or “Armed Away Instant message. The red ARMED indicator lights and the system announces Armed Stay Instant –exit now” or Armed Away Instant –exit now”.
When armed with “Instant”, the system will sound an alarm if a protected door or window is opened, including the entrance door. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will sound as soon as someone reenters.
To arm the system with no delay (Instant)
Ready To Arm
Arm Away
Arm Stay
10:18 AM June 8, 2010
Zones
Message
System
Phone
MoreDelay
5000-100-006-V0
Quick Exit
If active, you can restart the exit delay at any time after arming has been armed in Stay or Away mode by selecting the Quick Exit icon. This avoids having the user disarm then re­arm the system after allowing someone to enter or exit. The system will re-arm once the exit delay expires.
Armed: Stay
Zones
System
1. Select the “Delay” tab on the home screen.
The icon will ‘toggle” and “Instant” will be displayed.
2. Arm the system in the “Stay” or Away mode
normally.
Note: The entry delay time is eliminated when
Instant is selected.
1. Select the “Quick Exit” icon to restart the exit
delay.
Note: Quick Exit is active in Away mode when : Auto
Stay mode is enabled and no entry/exit zone has been faulted during the exit delay period.
Disarm Quick Exit
10:18 AM June 8, 2010
Message
Phone
More
5000-100-060-V0
22
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Entry/Exit Delays
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
Exit Delay
Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm. The system display will count down the time remaining in the exit delay, if programmed by your installer. If the system has been Armed Away, a slow beeping will sound throughout the exit delay period, if programmed by your installer. The exit door must be closed before the end of the exit delay. During the last 10 seconds of the exit delay fast beeps will sound as a warning that the delay time is nearing its end. The exit beeps cannot be silenced.
Restarting Exit Delay While System Armed
Ask your installer if this feature is active for your system. If active, you can restart the exit delay one time after arming in Stay or Away mode during the exit delay by selecting the Restart key. This will allowing extra time for someone to enter or exit or re-enter the property before the system is armed.
Armed: Stay - Exit Now
Exit now 28 seconds
Zones
System
Disarm
Restart
10:18 AM June 8, 2010
Message
Phone
More
5000-100-061-V0
Exit Alarms
To minimize false alarms sent to the alarm monitoring company, your system may have been programmed for this feature. Ask your installer if Exit Alarm is active for your system.
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message Alarm Cancelled is displayed, in the system bar. Additionally, Alarm and the faulted zone are displayed with their associated icons in the system/zone status area. No message is sent to the alarm monitoring company. To clear the exit alarm condition, the open zone must be secured. To clear the display, select the “Disarm” icon OR depress the “Off” key and then enter your security code. If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is still open, the alarm sound continues and an "exit alarm" message is sent to the alarm monitoring company. The message Alarm Exit Error" is displayed, in the system bar. Additionally, Alarm and the faulted zone are displayed with their associated icons in the
23
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES Entry/Exit Delays
Entry/Exit Delays
Entry/Exit DelaysEntry/Exit Delays
system/zone status area. The alarm will continue to sound until the system is disarmed or timeout ocurs. To stop the alarm, the system must be disarmed by selecting the “Disarm” icon OR depressing the “Off” key and then entering your security code. The message “Alarm Cancelled" is displayed, in the system bar, indicating that the alarm has been cancelled (if this feature is enabled by the installer). “Alarm” and the faulted zone continue to be displayed with their associated icons in the system/zone status area. To clear the display, select the “Disarm” icon OR depress the “Off” key and then enter your security code a second time. An exit alarm also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.
Entry Delay
Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. You must disarm the system before the entry delay period ends, or an alarm will occur. The control beeps during the entry delay period, reminding you to disarm the system. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the control to disarm the system. You can also arm the system with no entry delay at all by selecting the “Delay” icon prior to arming the system. This will toggle the system to Instant, which can provide greater security while on the premises or while away for extended periods of time. See ARMING THE SYSTEM section for procedure. See your installer for delay times programmed for your system.
Exit Delay:
None, 30, 45, 60, 90 seconds, 2 minutes
Entry Delay 1:
Entry Delay 2:
LYNX Touch SIA Exit/Entry Delay Times
Exit Delay: 45, 60, 90 seconds, 2 minutes
Entry Delay 1: 30, 45, 60, 90 seconds, 2, 3, 4 minutes
Entry Delay 2: 30, 45, 60, 90 seconds, 2, 3, 4 minutes
None, 30, 45, 60, 90 seconds, 2 minutes
None, 30, 45, 60, 90 seconds, 2 minutes
24
Loading...