Honeywell 8000 User Manual

DONE
M24083
DONE
M24085
TEST NUMBER
SYSTEM STATUS
Setup functions Setting & Options (factory
69-1871-1
SCHED HOLD
FAN
ON
AUTO
AM
SYSTEM
HEAT
Inside
M24079
0520 U/V lamp change
0530 Adaptive Intel-
0540 Program periods 4 4 periods (Wake,
0580 Compressor
0600 Heat temperature
0610 Cool temperature
0640 Clock format 12 12-hour time
0650 Extended fan
0660 Extended fan
0670 Keypad Lockout 0 Unlocked
Table 1. Installer Setup
reminder
ligent Recovery
protection
range stop
range stop
timer (heat)
timer (cool)
default in bold)
0 Off
1 365 calendar days
1 On
TM
0 Off
Leave, Return, Sleep)
2 2 periods (Wake, Sleep)
5 5-minute compressor
off time
[Other options: 0–4 minutes]
90 Max. heat temperature
setting is 90°F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
50 Min. cool temperature
setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
24 24-hour time
0 Off
90 Fan runs for 90 seconds
after call for heat ends
0 Off
90 Fan runs for 90 seconds
after call for cooling ends
1 Partially locked 2 Fully locked
Setup functions Setting & Options (factory
0680 Heat temperature
0690 Cool temperature
0700 Temperature
0710 RESET 0 No reset
Table 1. Installer Setup
control
control
display offset
default in bold)
2 Standard temperature
control (recommended)
1 Select if inside tempera-
ture is consistently over setting
3 Select if inside tempera-
ture is consistently under setting
2 Standard temperature
control (recommended)
1 Select if inside tempera-
ture is consistently over setting
3 Select if inside tempera-
ture is consistently under setting
0 No offset
[Other options: -3, -2,
-1, 1, 2, 3°F (-1.5°C to
1.5°C)]
1 Reset installer options
& program schedule to factory default
The Installer Test is part of the Installer Setup Menu.
Enter the Installer System Test by entering the Installer
1. Setup and pressing t repeatedly until “Test” appears.
Use arrow to change test and system status as
2. required.
Press DONE to exit.
3.
SYSTEM TESTS
Test the system’s heating, cooling, fan and emergency heat. Available tests vary by thermostat and system type.
System Test
Number
Test 1 Cooling System
Test 2 Fan System
Test 3 Heating System
Test 4 Emergency
Press the DONE button to exit the Installer System Test.
caution
Table 2. Installer System Test
Test Type System Status Number
Test
Test
Test
Heat Test
EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compres­sor quickly.
and Description
0 Off 1 Compressor and
fan on
2 Second stage
compressor on
0 Off 1 Fan on
0 Off 1 Heat on 2 Second stage heat
(Aux. heat) on
3 Third stage heat
(Auxiliary heat) on
0 Off 1 Em. Heat and fan on 2 Auxiliary heat on
VisionPRO® 8000
Thermostats
INSTALLER SETUP AND
SYSTEM TEST POCKET GUIDE
INSTALLER SETUP
Press SYSTEM.
1.
6 7 8 9
Press and hold these two blank buttons until the
DONE
CANCEL
SYSTEM
HEAT
M24080
DONE
FUNCTION
SETTING
M24082
2. display changes.
Use arrows to change settings as required.
3.
Press DONE to exit and save settings.
4.
INSTALLER SETUP FUNCTIONS
Available option and default settings vary by thermostat.
Setup functions Setting & Options (factory
0120 Year (rst two
0130 Year (second two
0140 Month 6 [Other options 1-12]
0150 Day 15 [Other options 1-31]
0160 Schedule format 4 7-day programming
Table 1. Installer Setup
digits)
digits)
default in bold)
20 (2000-2099)
21 (2100-2178)
06 (2006) [Other options 0-99]
0 Non-programmable
Setup functions Setting & Options (factory
0170 System type 1 1 heat / 1 cool Conv.
0180 Fan control
(heating)
0190 Changeover valve
(O/B terminal)
0200 Auxiliary heat 0 Electric backup heat
0210 External fossil
0220 First stage
0230 Second stage
fuel kit
compressor cycle rate
compressor cycle rate
default in bold)
2 1 heat / 1 cool heat
pump (no Aux. heat) 3 Heat only (2 wire) 4 Heat only with fan 5 Hot water Series 20 6 Cool only 7 2 heat / 1 cool heat
pump (with Aux. heat) 8 2 heat / 2 cool multistage 9 2 heat / 1 cool multistage 10 1 heat / 2 cool multistage 11 2 heat / 2 cool heat pump
(no Aux. heat) 12 3 heat / 2 cool heat
pump (with Aux. heat)
0 Gas/Oil heat (equipment
controls heating fan)
1 Electric furnace (thermo-
stat controls heating fan)
0 Controls valve in cooling
1 Controls valve in heating
1 Fossil fuel backup heat
1 External fossil fuel kit
controls backup heat
0 Thermostat controls
backup heat (outdoor
sensor required)
3 Recommended
[Other options: 1–6]
3 Recommended
[Other options: 1–6]
Table 1. Installer Setup
Setup functions Setting & Options (factory
0240 First stage heat
cycle rate
0250 Second stage
heat cycle rate
0260 Third stage heat
cycle rate
0270 Emergency heat
cycle rate
0280 Backlight 0 Backlight on keypress
0300 Manual/auto
changeover
default in bold)
5 Gas or oil furnaces of
less than 90%
efciency
1 Steam or gravity 3 Hot water systems or fur-
naces of 90%+ efciency
9 Electric furnaces
[Other options: 1–12]
5 Gas or oil furnaces of
less than 90% efciency
1 Steam or gravity 3 Hot water systems or fur-
naces of 90%+ efciency
9 Electric furnaces
[Other options: 1–12]
9 Electric auxiliary heat
or electric furnaces
1 Steam or gravity 3 Hot water systems or fur-
naces of 90%+ efciency
5 Gas or oil furnaces of
less than 90% efciency [Other options: 1–12]
9 Electric auxiliary heat
or electric furnaces
1 Steam or gravity 3 Hot water systems or fur-
naces of 90%+ efciency
5 Gas or oil furnaces of
less than 90% efciency [Other options: 1–12]
1 Continuous backlight (re-
quires 24VAC connection)
0 Manual changeover
(Heat/Cool/Off)
1 Automatic changeover
(Heat/Cool/Auto/Off)
Table 1. Installer Setup
Setup functions Setting & Options (factory
0310 Auto changeover
deadband
0320 Temperature
display
0330 Daylight savings 1 Auto-change to daylight
0340 Remote sensor 0 No remote sensor
0350 Heat pump com-
pressor lockout
0360 Heat pump auxil-
iary lockout
0380 Dehumidication
Control
0500 Furnace lter
change reminder
0510 Humidier pad
change reminder
default in bold)
3 Heat/cool tempera-
ture 3°F apart (1.5°C)
[Other options: 2-9 (2°F­9°F/1°C-5°C)]
0 Fahrenheit
1 Celsius
savings time (through
2006)
2 Auto-change to daylight
savings time (2007 and beyond)
0 Daylight savings time is
turned off
1 Outdoor sensor (display
only)
2 Outdoor sensor for con-
trol (select heat pumps)
3 Indoor sensor
0 Off
[Other options: 15, 20, 25, 30, 35, 40°F (-9.5°C to 7°C)]
0 Off
[Other options: 40, 45, 50, 55, 60°F (4.5°C to
15.5°C)]
0 Off
1 A/C runs to help
dehumidify
0 Off
1 10-day run time
(about 1 month)
2 30-day run time
(about 3 months)
3 60-day run time
(about 6 months)
4 90-day run time
(about 9 months)
5 120-day run time
(about 1 year)
6 365-day run time
(about 3 years)
0 Off
1 90 calendar days 2 180 calendar days 3 365 calendar days
Table 1. Installer Setup
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
http://yourhome.honeywell.com
® U.S. Registered Trademark © 2006 Honeywell International Inc. US Patent No. 6595430, D509151; other Patents Pending. All Rights Reserved 69-1871-1 M.S. Rev. 09-06
2 3 4 5
Loading...