Before operating the generator for the first time, please
read this Owner’s Manual. Even if you have operated
other generators, take time to become familiar with how
this generator operates.
QUICK FIND
Air Cleaner ...................................... 13Engine Oil Change .......................... 12How to Contact Honda .............................. 20
AC Operation .................................... 9Engine Oil Recommendations......... 13Maintenance Schedule.............................. 11
Dealer Locator Information ............. 20Fuel Recommendations .................. 12Refueling ................................................... 12
Congratulations on your selection of a Honda generator!
We are certain you will be pleased with your purchase of one of the
finest generators on the market. We want to help you get the best
results from your new generator and to operate it safely. This manual
contains information on how to do that; please read it carefully.
When your generator needs scheduled maintenance, keep in mind
that Honda Power Equipment servicing dealership personnel are
specially trained in servicing Honda generators and are supported by
the parts and service divisions of American Honda.
Please read the DISTRIBUTOR’S LIMITED WARRANTY on page 21
and the EMISSION CONTROL SYSTEM WARRANTY on page 22 to
fully understand what is covered by warranty and your responsibilities
of ownership.
FOR YOUR SAFETY
Your safety and the safety of others are very important. We have
provided important safety messages in this manual and on the
generator. This information alerts you to potential hazards that could
hurt you or others. Please read these messages carefully.
Of course, it is not practical or possible to warn you about all the
hazards associated with operating or maintaining a generator. You
must use your own good judgment.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
California Proposition 65
This product contains or emits
chemicals known to the State of
California to cause cancer, birth
defects, or other reproductive harm.
WARNING
Exhaust contains poisonous carbon monoxide gas that
can build up to dangerous levels in a closed area.
Breathing carbon monoxide can cause unconsciousness
or death.
Never run the generator in a closed, or even partly closed
area where people may be present.
GENERATOR SAFETY
Important Safety Information
Safety Instructions
You will find important safety information in a variety of forms:
Safety Labels – on the generator
Instructions – how to use this generator correctly and safely
Safety Messages – preceded by a safety alert
three signal words: DANGER, WARNING, or CAUTION.
Each message tells you what the hazard is, what can happen, and
what you can do to avoid or reduce injury.
These signal words mean:
DANGER
WARNING
CAUTION
Damage Prevention Messages – you will also see other important
messages that are preceded by the word NOTICE. This word means:
NOTICE
Your engine or other property can be
damaged if you don’t follow instructions.
You WILL be KILLED or SERIOUSLY
HURT if you don’t follow instructions.
You CAN be KILLED or SERIOUSLY
HURT if you don’t follow instructions.
You CAN be HURT if you don’t follow
instructions.
symbol and one of
Honda generators are designed for use with electrical equipment that
has suitable power requirements. Other uses can result in injury to the
operator or damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all the
instructions in this manual and on the generator. The most common
hazards are discussed below, along with the best way to protect
yourself and others.
Never attempt to modify the generator. It could result in an injury as
well as damage to the generator and/or the attached appliances.
• Do not connect an extension to the muffler.
• Do not modify the intake system.
• Do not remove the control panel or change the control panel wiring.
Operator Responsibility
• Know how to stop the generator quickly in case of emergency.
• Understand the use of all generator controls, output receptacles,
and connections.
• Be sure that anyone who operates the generator receives proper
instruction. Do not let children operate the generator without
parental supervision.
Carbon Monoxide Hazards
A generator's exhaust contains toxic carbon monoxide, which you
cannot see or smell. Breathing carbon monoxide can KILL YOU IN
MINUTES. To avoid carbon monoxide poisoning, follow these
instructions when operating a generator:
• Never operate a generator inside a house, garage, basement, crawl
space, or any enclosed or partially enclosed space.
• Only run a generator OUTSIDE, far away from windows, doors, and
vents.
• Never operate a generator near open doors or windows.
• Get fresh air and seek medical attention immediately if you suspect
you have inhaled carbon monoxide.
2
Early symptoms of carbon monoxide exposure include headache,
fatigue, shortness of breath, nausea, and dizziness. Continued
exposure to carbon monoxide can cause loss of muscular
coordination, loss of consciousness, and then death.
Electric Shock Hazards
• The generator produces enough electric power to cause a serious
shock or electrocution if misused.
• Using a generator or electrical appliance in wet conditions, such as
rain or snow, or near a pool or sprinkler system, or when your hands
are wet, could result in electrocution. Keep the generator dry.
• If the generator is stored outdoors, unprotected from the weather,
check all of the electrical components on the control panel before
each use. Moisture or ice can cause a malfunction or short circuit in
electrical components that could result in electrocution.
• Do not connect to a building's electrical system unless an isolation
(transfer) switch has been installed by a qualified electrician.
Fire and Burn Hazards
• The exhaust system gets hot enough to ignite some materials.
– Keep the generator at least 3 feet (1 meter) away from buildings
and other equipment during operation.
– Do not enclose the generator in any structure.
– Keep flammable materials away from the generator.
• The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful not to touch the muffler
while it is hot. Let the engine cool before storing the generator
indoors.
Safety Label Locations
These labels warn you of potential hazards that can cause serious
injury. Read them carefully. If a label comes off or becomes hard to
read, contact an authorized Honda servicing dealer for a replacement.
Refuel With Care
• Gasoline is extremely flammable, and gasoline vapor can explode.
• Do not refuel during operation.
• Allow the engine to cool if it has been in operation.
• Refuel only outdoors in a well-ventilated area and on a level surface.
• Never smoke near gasoline, and keep other flames and sparks
away.
• Do not overfill the fuel tank. Overfilling the fuel tank may cause fuel
to leak out of the bottom of the EVAP canister.
• Make sure that any spilled fuel has been wiped up before starting
the engine.
• Always store gasoline in an approved container.
3
INITIAL USE INFORMATION
NOTICE
OIL FILLER
CAP/DIPSTICK
OIL FILLER NECK
UPPER LIMIT
UPPER LEVEL MARK (RED)
(Do not overfill)
FUEL TANK CAP
Add Engine Oil
The generator is
shipped WITHOUT OIL
in the engine. Place the
generator on a level
surface. Remove the oil
filler cap/dipstick.
All Honda engines are
run at the factory prior to
packaging. Most of the
oil is removed prior to
shipment; however,
some oil remains in the
engine. The amount of
oil left in the engine
varies.
Add enough SAE
10W-30 API service
category SJ or later oil
to bring the oil level to
the upper limit of the oil filler neck (approximately 12 to 13.5 ounces is
required). 10W-30 motor oil is recommended for general use. For
additional recommendations, see page 13.
Do not overfill the engine with oil. If the engine is overfilled, the
excess oil may get transferred to the air cleaner housing and air filter.
An indication of overfilling is white or blue smoke coming from the
muffler when the engine is running.
After filling the engine with oil, screw the oil filler cap/dipstick in and
remove the hang tag located on the fuel cap that says “The engine has no oil.”
1. Remove the fuel tank cap.
2. Add fuel slowly to prevent spilling. Do not fill the fuel tank above
the upper level mark (red) on the fuel strainer. Overfilling the fuel
tank may cause fuel to leak out of the bottom of the EVAP canister.
3. After adding fuel, reinstall the fuel tank cap securely.
Move the generator at least 10 feet (3 meters) away from the fueling
source and site before starting the engine.
Fuel can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spilled fuel is not covered
under the DISTRIBUTOR’S LIMITED WARRANTY.
Please Register Your Generator
Please take a few minutes and register your purchase with Honda.
You can register:
• By completing and mailing the registration card on the back cover of
this book
• Going on-line to powerequipment.honda.com and clicking on
Product Registration
• By scanning the QR code
Fuel
Add fuel to the generator in a well-ventilated area. Never refuel the
engine inside a building where gasoline fumes may reach flames or
sparks. Keep gasoline away from appliance pilot lights, barbecues,
electric appliances, power tools, etc. Spilled fuel is not only a fire
hazard, it causes environmental damage. Wipe up spills immediately.
This engine is certified to operate on unleaded gasoline with a pump
octane rating of 86 or higher containing no more than 10% ethanol
(E10) or 5% methanol by volume. Refer to page 12 for additional fuel
recommendations.
WARNING
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling
fuel.
• Stop the engine and let it cool before refueling
• Keep heat, sparks, and flame away
• Refuel only outdoors
• Wipe up spills immediately
Before Using Your Generator
All Generator operators must read the following sections:
• FOR YOUR SAFETY (page 2)
• GENERATOR SAFETY(page 2)
• BEFORE EACH USE (page 5)
• OPERATION (page 7)
• STARTING THE ENGINE (page 7)
• STOPING THE ENGINE (page 8)
• MAINTENANCE SCHEDULE (page 11)
4
BEFORE EACH USE
OIL FILLER
CAP/DIPSTICK
FUEL VALVE
LEVER
FUEL TANK CAP
MUFFLER
STARTER GRIP
EVAP CANISTER
AIR CLEANER
FUEL SEDIMENT
CUP
CONTROL PANEL
GFCI RECEPTACLES
GROUND
TERMINAL
ENGINE SWITCH
CHOKE ROD
ECO-THROTTLE SWITCH
OIL ALERT
INDICATOR/CHECK
AC CIRCUIT
PROTECTORS
OUTPUT INDICATOR
OVERLOAD ALARM
CONTROLS & FEATURES
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of injury.
Read and understand this manual. Know what the controls do and
how to operate them.
Familiarize yourself with the generator and its operation before you
begin using it. Know how to quickly shut off the generator in case of
an emergency.
Check Your Generator
For your safety, and to maximize the service life of your generator, it is
very important to take a few moments before you operate the
generator to check its condition. Be sure to take care of any problem
you find, or have your servicing dealer correct it, before you operate
the generator.
WARNING
Improperly maintaining this generator, or failing to correct
a problem before operation, could cause a significant
malfunction.
Some malfunctions can seriously hurt or kill you.
Always perform a pre-operation inspection before each
operation, and correct any problem.
• Make sure the generator is on a level surface
• Look around and underneath the generator for signs of oil or
gasoline leaks
• Look for signs of damage
• Check each control for proper operation
• Check that all nuts, bolts, and screws are tightened
• Check the air filter (page 13) and oil level (page 12)
• Check the fuel level (page 12). Starting with a full tank will help to
eliminate or reduce operating interruptions for refueling
• Check the operation of the GFCI receptacles (page 8)
Component and Control Locations
Use the illustrations on these pages to locate and identify the most
frequently used controls.
5
Controls
NOTICE
OFFON
FUEL
VALVE
LEVER
CHOKE ROD
OPEN
CLOSED
ENGINE
SWITCH
OFF
ON
STARTER
GRIP
GFCI RECEPTACLES
AC CIRCUIT
PROTECTORS
OFF
ON
PUSH
TO
RESET
GFCI RECEPTACLES
ECO-THROTTLE
SWITCH
OFF
ON
OUTPUT
INDICATOR
(GREEN)
Fuel Valve Lever
The fuel valve lever is
located between the
fuel tank and
carburetor.
The fuel valve lever
must be in the ON
position for the engine
to run.
After stopping the
engine, turn the fuel
valve lever to the OFF
position.
Choke Rod
The choke rod opens and
closes the choke valve in the
carburetor.
Pulling the choke rod to the
CLOSED position enriches the
fuel mixture for starting a cold
engine.
Pushing the choke rod to the OPEN position provides the correct fuel
mixture for operation after starting, and for restarting a warm engine.
Engine Switch
The engine switch controls the
ignition system.
OFF - Stops the engine.
ON - Running position, and for
starting with the recoil starter.
Recoil Starter
Pulling the starter grip
operates the recoil starter to
crank the engine.
Do not allow the starter grip
to snap back against the
engine. Return it gently to prevent damage to the starter.
Do not let the starter rope rub against the generator body, or the rope
will wear out prematurely.
Each 120 V 20 A duplex receptacle
is protected by a Ground Fault
Circuit Interrupter (GFCI) for
protection against the shock
hazard of ground-fault currents.
An example of ground-fault current
is the current that would flow
through a person who is using an
appliance with faulty insulation
and, at the same time, is in contact
with an electrical ground such as a
plumbing fixture, wet floor, or earth.
The GFCI will protect against current flowing through that person.
The GFCI will not protect against short circuit or overloads.
6
GFCIs can be expected to interrupt power supply if there are ground
faults or stray current imposed on the wiring by other electrical
devices, wiring, or equipment. Due to the risk of a power interruption,
this generator is not recommended for powering medical or life
support equipment.
AC Circuit
Protector
The AC circuit protector
will automatically switch
to OFF if there is a short
circuit or a significant
overload of the
generator at each GFCI
receptacle. If an AC
circuit protector
switches OFF
automatically, check that
the appliance is working
properly and does not exceed the rated load capacity of the circuit
before resetting the AC circuit protector ON.
ECO THROTTLE
®
Switch
The Eco Throttle system
automatically reduces engine
speed when loads are turned
off or disconnected. When
appliances are turned on or
reconnected, the engine
returns to the proper speed to
power the electrical load.
If high electrical loads are connected simultaneously, turn the Eco
Throttle switch to the OFF position to reduce voltage changes.
ON: Recommended to minimize fuel consumption and further reduce
noise levels when less than a full load is applied to the generator.
OFF: The Eco Throttle system does not operate. Generator operates
at full speed.
Features
Output Indicator
The output indicator (green) is
illuminated when the generator
is operating normally. It
indicates that the generator is
producing electrical power at
the receptacles.
In addition, the output indicator
has a simplified hour meter
function. When you start the
engine, the indicator blinks according to the generator’s cumulative
operating hours as follows:
• No blinks: 0~100 hours
• 1 blink: 100~200 hours
• 2 blinks: 200~300 hours
• 3 blinks: 300~400 hours
• 4 blinks: 400~500 hours
• 5 blinks: 500 or more hours
Overload Alarm
NOTICE
OVERLOAD
ALARM (RED)
OIL ALERT
INDICATOR/
CHECK (RED)
GROUND
TERMINAL
ON
FUEL VALVE
LEVER
ECO-THROTTLE
SWITCH
OFF
ON
CHOKE ROD
OPEN
CLOSED
(Indicator)
If the generator is overloaded
(in excess of 2.8kVA), or if
there is a short circuit in a
connected appliance, the
overload alarm (red) will come
ON. The overload alarm (red)
will stay ON, and after about
4~10 seconds, current to the connected appliance(s) will shut off, and
the output indicator (green) will go OFF. However, the engine will
continue to run.
Oil Alert
®
Indicator/Check
The Oil Alert system is
designed to prevent engine
damage caused by an
insufficient amount of oil in the
crankcase. Before the oil level
in the crankcase can fall
below a safe limit, the Oil Alert
indicator/check (red) comes on and the Oil Alert system automatically
will stop the engine (the engine switch will remain in the ON position).
If the engine stops or the Oil Alert indicator/check (red) comes on
when you pull the starter grip, check the engine oil level (page 12)
before troubleshooting in other areas.
Ground Terminal
The generator ground
terminal is connected to the
frame of the generator, the
metal non-current-carrying
parts of the generator, and
the ground terminals of
each receptacle.
Before using the ground terminal, consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local codes
or ordinances that apply to the intended use of the generator.
Before connecting an AC appliance or power cord to the generator:
• Use grounded 3-prong extension cords, tools, and appliances, or
double-insulated tools and appliances.
• Inspect cords and plugs, and replace if damaged.
• Make sure that the appliance is in good working order. Faulty
appliances or power cords can create a potential for electric shock.
• Make sure the electrical rating of the tool or appliance does not
exceed the rated power of the generator or the receptacle being
used.
• Operate the generator at least 3 feet (1 meter) away from buildings
and other equipment.
• Do not operate the generator in an enclosed structure.
• Do not place flammable objects close to the engine or locate the
generator near flammable materials.
Starting the Engine
To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from building walls and other equipment during operation. Do
not place flammable objects close to the engine.
Operating this generator less than 3 feet (1 meter) from a building
or other obstruction can cause overheating and damage the
generator. For proper cooling, allow at least 3 feet (1 meter) of
empty space
Refer to GENERATOR SAFETY on page 2 and perform the BEFORE
EACH USE checks (page 5). Refer to AC OPERATION (page 9) for
connecting loads to the generator.
1. Make sure that all appliances are disconnected from the AC
receptacles.
2. Turn the fuel valve lever to
the ON position.
above and around the generator.
OPERATION
Safe Operating Instructions
Before operating the generator for the first time, review chapters
GENERATOR SAFETY (page 2) and BEFORE EACH USE
(page 5).
For your safety, do not operate the generator in an enclosed area
such as a garage. Your generator's exhaust contains poisonous
carbon monoxide gas that can collect rapidly in an enclosed area and
cause illness or death.
WARNING
Exhaust contains poisonous carbon monoxide gas
that can build up to dangerous levels in a closed area.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run the generator in a closed, or even partly
closed area where people may be present.
3. Make sure the Eco Throttle
switch is in the OFF position,
or more time will be required
for warm-up.
4. To start a cold engine, pull
the choke rod out to the
CLOSED position.
To restart a warm engine,
leave the choke rod in the
OPEN position.
7
5. Turn the engine switch to the
NOTICE
ENGINE
SWITCH
OFF
ON
STARTER
GRIP
CHOKE
ROD
OPEN
CLOSED
ENGINE
SWITCH
OFF
ON
OFF
FUEL VALVE
LEVER
GFCI RESET BUTTON
GFCI TEST BUTTON
LED
GFCI
RECEPTACLES
ON position.
6. Pull the starter grip lightly
until resistance is felt,
then pull briskly.
Do not allow the starter grip
to snap back against the
engine. Return it gently to
prevent damage to the
starter.
Do not let the starter rope rub against the generator body, or the rope
will wear out prematurely.
7. If the choke rod was moved
to the CLOSED position to
start the engine, gradually
push it to the OPEN position
as the engine warms up.
8. If you wish to use the Eco
Throttle system, turn the Eco
Throttle system switch to the
ON position after the engine has warmed up for 2 or 3 minutes.
Stopping the Engine
To stop the engine in an emergency, simply turn the engine switch to
the OFF position. Under normal conditions, use the following
procedure.
1. Turn off or disconnect all appliances that are connected to the
generator.
2. Turn the engine switch to the
OFF position.
3. Turn the fuel valve lever to
the OFF position.
GFCI Operation Check
Always check GFCI operation before using the generator.
WARNING
A faulty GFCI can cause electric shock which can
seriously injury or kill you.
An electric shock can result in serious injury or death.
Always perform the GFCI inspection before using the
generator. If the GFCI fails the test, the generator must be
repaired by an authorized Honda servicing dealer before
use.
1. Unplug all tools and appliances from the generator.
2. Check that the circuit protector is set to the ON position
3. Start the engine (page 7).
4. Press the TEST
button:
– The RESET button
should extend and
the LED will light.
– If the GFCI does
not function as
described, contact
an authorized
Honda generator
dealer.
5. Press the RESET
button
– The RESET
button should be flush with the base.
– If the RESET button is not flush with the TEST button, contact
an authorized Honda generator dealer.
6. Check the GFCI LED to see if it is correctly functioning. If the GFCI
is faulty, contact an authorized Honda generator dealer.
ConditionLED
NormalOFF
Leakage detectedON
End of serviceable lifeON
Internal malfunctionFLASHING
When the RESET button extends or the GFCI LED is lit during
operation:
– Unplug all appliances from the GFCI protected receptacle.
– Press the RESET button.
– If the GFCI cannot be reset, the GFCI is faulty. Contact an
authorized Honda generator dealer.
– If the RESET button extends when operating the appliance,
this usually indicates a faulty power tool, appliance, or cord. If
that occurs, perform operation check steps 1 through 5 to
verify that the GFCI is in proper working order. If the GFCI
tests correctly, then the fault is likely to be in the power tool,
appliance, or cord. Repair or replace the faulty power tool,
appliance, or cord before further use.
8
AC Operation
NOTICE
NOTICE
NOTICE
ECO-THROTTLE
SWITCH
OFF
ON
Eco Throttle System
Before connecting an appliance(s) to the generator, make sure that it
is in good working order and that the appliance(s) total electrical rating
does not exceed that of the generator.
Most motorized appliances require more than their electrical rating for
startup. When an electric motor is started, the overload alarm (red)
may come on. This is normal if the overload alarm (red) goes off
within 4~10 seconds. If the overload alarm (red) stays on, consult
your generator dealer.
Substantial overloading may damage the generator. Marginal
overloading may shorten the service life of the generator.
1. Start the engine (page 7) and make sure the output indicator
(green) comes on.
2. Plug in the appliance.
3. Turn on the appliance.
If the generator is overloaded (in excess of 2.8 kVA), if there is a short
circuit in a connected appliance, or if the inverter is overheated, the
overload alarm (red) will come ON. The overload alarm (red) will stay
ON, and after about 4~10 seconds, current to the connected
appliance(s) will shut off, and the output indicator (green) will go OFF.
Stop the engine and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an
overload. Correct the problem and restart the generator.
With the switch in the ON
position, engine speed is
automatically lowered when
electrical loads are reduced,
turned off, or disconnected.
When appliances are turned on
or reconnected, the engine
returns to the proper speed to
power the electrical load. In the
OFF position, the Eco Throttle
system does not operate and
the engine runs at high speed.
Appliances with large start-up power demands may not allow the
engine to reach normal operating rpm when they are connected to the
generator. Turn the Eco Throttle switch to the OFF position and
connect the appliance to the generator. If the engine still will not reach
normal operating speed, check that the appliance does not exceed
the rated load capacity of the generator.
If high electrical loads are connected simultaneously, turn the Eco
Throttle switch to the OFF position to reduce voltage changes.
The Eco Throttle system is not effective for use with appliances or
tools that require only momentary power. If the tool or appliance will
be turned ON and OFF quickly, the Eco Throttle switch should be in
the OFF position.
AC Applications
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. A faulty appliance or
power cord can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance or if the rated
load capacity of the generator has been exceeded.
Most appliance motors require more than their rated wattage for
startup.
Make sure the electrical rating of the tool or appliance does not
exceed the maximum power rating of the generator.
Maximum power is: 2.8 kVA
For continuous operation, do not exceed the rated power.
Rated power is: 2.5 kVA
In either case, the total power requirements (VA) of all appliances
connected must be considered. Appliance and power tool
manufacturers usually list rating information near the model number
or serial number.
Substantial overloading that continuously lights the red overload
alarm may damage the generator. Marginal overloading that
temporarily lights the red overload alarm may shorten the service life
of the generator.
Standby Power
Connections to a Building's Electrical System
The Honda EB2800i generator is designed for construction job site
use. This generator has the neutral bonded to ground to comply with
OSHA job site temporary power regulation. Building main breaker
boxes also have the neutral bonded to ground, so if an EB2800i
generator is connected to a home or building electrical system, the
GFCI relay will trip. Connections for standby power to a building's
electrical system must be made by a qualified electrician. The
connection must completely isolate the generator power from utility
power, and must comply with all applicable laws and electrical codes.
Special transfer switches are available to connect a neutral bonded
generator to a building’s electrical system.
System Ground
This generator has a system ground that connects the generator
frame components to the ground terminals in the AC output
receptacles. The system ground is connected to the AC neutral wire.
Special Requirements
Do not lay the generator on its side when moving, storing, or
operating it. Oil may leak and damage the engine or your property.
There may be Federal or State Occupational Safety and Health
Administration (OSHA) regulations, local codes, or ordinances that
apply to the intended use of the generator. Please consult a qualified
electrician, electrical inspector, or the local agency having jurisdiction.
• In some areas, generators are required to be registered with local
utility companies.
• If the generator is used at a construction site, there may be
additional regulations that must be observed.
9
SERVICING YOUR GENERATOR
The Importance of Maintenance
Good maintenance is essential for safe, economical, and trouble free
operation. It will also help reduce air pollution.
To help you properly care for your generator, the following pages
include a maintenance schedule, routine inspection procedures, and
simple maintenance procedures using basic hand tools. Other service
tasks that are more difficult or require special tools are best handled
by professionals and are normally performed by a Honda technician
or other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If
you operate your generator under unusual conditions, such as
sustained high-load or high-temperature operation, or use it in dusty
conditions, consult your servicing dealer for recommendations
applicable to your individual needs and use.
WARNING
Improper maintenance, or failure to correct a problem
before operation, can cause a malfunction in which
you can be seriously hurt or killed.
Always follow the inspection and maintenance
recommendations and schedules in this manual.
Remember that an authorized Honda servicing dealer knows your
generator best and is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new, Honda
Genuine parts or their equivalents for repair and replacement.
Maintenance, replacement, or repair of the emission control
devices and systems may be performed by any engine repair
establishment or individual, using parts that are ''certified'' to
EPA standards.
Maintenance Safety
Some of the most important safety precautions follow. However, we
cannot warn you of every conceivable hazard that can arise in
performing maintenance. Only you can decide whether or not you
should perform a given task.
WARNING
Failure to properly follow maintenance instructions and
precautions can cause you to be seriously hurt or
killed.
Always follow the procedures and precautions in the
owner's manual.
Safety Precautions
Make sure the engine is off before you begin any maintenance or
repairs. This will eliminate several potential hazards:
– Carbon monoxide poisoning from engine exhaust.
Be sure there is adequate ventilation whenever you operate the
engine.
– Burns from hot parts.
Let the engine and exhaust system cool before touching.
– Injury from moving parts.
Do not run the engine unless instructed to do so.
• Read the instructions before you begin, and make sure you have
the tools and skills required.
• To reduce the possibility of fire or explosion, be careful when
working around gasoline. Use only a non-flammable solvent, not
gasoline, to clean parts. Keep cigarettes, sparks, and flames away
from all fuel-related parts.
10
Maintenance Schedule*
Maintenance Schedule
ItemActionBefore
Engine oilCheck level
Change
Air filterCheck
Clean
Replace
GFCI operationCheck
Sediment cupClean
Spark plugCheck-
adjust
Replace
Spark arresterClean
Valve clearanceCheck-
adjust
Combustion chamber Clean
Timing beltCheck
Fuel tank/filterClean
Fuel tubeCheckCheck every 2 years and replace if necessary (3)—
EVAP CanisterCheckCheck every 2 years and replace if necessary (3)—
Purge tubeCheckCheck every 2 years and replace if necessary (3)—
Charge tubeCheckCheck every 2 years and replace if necessary (3)—
* For commercial use, log hours of operation to determine proper maintenance intervals.
(1)Service more frequently when used in dusty areas.
(2)Change engine oil every 25 hours when used under heavy load or in high outside air temperatures.
(3)These items should be serviced by an authorized Honda servicing dealer unless you have the proper tools and are mechanically proficient.
Refer to the Honda shop manual for service procedures. See “Honda Publications” on page 20 for ordering information.
Failure to follow this Maintenance Schedule could result in non-warrantable failures.
each use
O
O
O
5hours
of use
or first
month
25 hours
of use
or every
3 months
50 hours
6 months
OO (2)
O (1)O (1)O (1)
After every 250 hrs(3)
After every 250 hrs(3)
of use
or every
100 hours
of use
or every
year
O
O
O
250 hours
of use
or every
2 years
O
O
O(3)
O(3)
See page
12
13
8
14
13
14
—
—
—
—
11
Refueling
NOTICE
NOTICE
UPPER LEVEL MARK (RED)
(Do not overfill)
FUEL TANK CAP
OIL FILLER
CAP/DIPSTICK
OIL FILLER NECK
UPPER LIMIT
Illustration in process
Illustration in process
OIL FILLER NECK
UPPER
LIMIT
OIL FILLER
CAP/DIPSTICK
DRAIN BOLT
WASHER
2”X 4” LUMBER
Engine Oil Level Check
With the engine stopped, remove the fuel tank cap and check the fuel
level. Refill the fuel tank if the fuel level is low. Turn the fuel valve OFF
(page 6).
WARNING
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling
fuel.
• Stop the engine and let it cool before refueling
• Keep heat, sparks, and flame away
• Refuel only outdoors
• Wipe up spills immediately
Fuel can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spilled fuel is not covered
under the DISTRIBUTOR’S LIMITED WARRANTY.
• Refuel in a well-ventilated area before starting the engine. If the
engine has been running, allow it to cool. Refuel carefully to avoid
spilling fuel.
• Do not fill the fuel tank above the upper level mark (shown above) or
fuel may flow into the EVAP canister causing fuel leakage from the
bottom of the canister.
• Never refuel the engine inside a building where gasoline fumes may
reach flames or sparks.
• Keep gasoline away from appliance pilot lights, barbecues, electric
appliances, power tools, etc.
• Spilled fuel is not only a fire hazard, it causes environmental
damage. Wipe up spills immediately.
Check the oil level BEFORE EACH USE with the generator on a level
surface and the engine stopped.
1. Remove the oil filler
cap/dipstick.
2. Check the oil level. If
it is below the upper
limit, fill with the
recommended oil
(page 13) to the
upper limit of the oil
filler neck.
3. Reinstall the oil filler
cap securely.
The Oil Alert system will
automatically stop the
engine before the oil
level falls below safe
limits. However, to avoid
the inconvenience of an
unexpected shutdown,
check the oil level regularly.
Engine Oil Change
Drain the oil while the engine is warm to assure rapid and complete
draining.
1. Place the generator on a level surface.
2. Place a suitable container below the engine to catch the oil, then
remove the drain plug and sealing washer, remove the oil filler cap,
and drain the oil.
3. Reinstall the oil drain plug and a new sealing washer. Tighten the
plug securely.
4. Refill with the recommended oil (page 13) and check the oil level.
Maximum capacity: 19.6 oz (0.58 L)
5. Reinstall the oil filler cap/dipstick and tighten it securely.
Wash your hands with soap and water after handling used oil.
Using non detergent oil can shorten the engine’s service life, and
using 2-stroke oil can damage the engine.
Fuel Recommendations
This engine is certified to operate on regular unleaded gasoline with a
pump octane rating of 86 or higher.
Never use gasoline that is stale, contaminated, or mixed with oil.
Avoid getting dirt or water in the fuel tank.
You may use regular unleaded gasoline containing no more than 10%
ethanol (E10) or 5% methanol by volume. In addition, methanol must
contain co-solvents and corrosion inhibitors.
Use of fuels with a content of ethanol or methanol greater than shown
above may cause starting and/or performance problems. It may also
damage metal, rubber, and plastic parts of the fuel system.
Engine damage or performance problems that result from using a fuel
with percentages of ethanol or methanol greater than shown above
are not covered under the DISTRIBUTOR’S LIMITED WARRANTY.
If your equipment will be used on an infrequent or intermittent basis,
please refer to the fuel section of the STORAGE chapter (page 14) for
additional information regarding fuel deterioration.
12
Engine Oil Recommendations
NOTICE
A MBI ENT TEM PER AT UR E
AIR CLEANER COVER
FOAM AIR FILTER
COVER
COVER TABS
PAPER AIR FILTER
COVER
HOOKS
GRID
Do not twist.
Do not twist.
Clean
Squeeze and Dry
Dip in Oil
Squeeze
SPARK PLUG
SPARK PLUG CAP
SPARK PLUG
WRENCH
0.028 ~ 0.031 in
(0.7 ~ 0.8 mm)
SEALING
WASHER
Oil is a major factor affecting performance and service life. Always
change the oil in accordance with the Maintenance Schedule
(page 11).
Recommended oil for general use: SAE 10W-30
Other viscosities shown in the chart may be used when the average
temperature in your area is within the recommended range.
5. Foam Air Filter: Wash the foam air filter in a solution of household
detergent and warm water, then rinse thoroughly, or wash in
non-flammable or high flash point solvent. Allow the foam air filter
to dry thoroughly.
6. Wipe dirt from the inside of the air cleaner housing and cover using
a moist rag. Be careful to prevent dirt from entering the air duct that
leads to the carburetor.
7. Reinstall the filters, grid, and cover as shown. Be sure both tabs
are fully locked in place.
The SAE oil viscosity and service category are in the API label on the
oil container. Honda recommends API service category SJ or later oil.
Air Cleaner
Clean the air filter after the first 25 hours of use. Thereafter, clean the
filter every 6 months or 50 hours of use. Clean the filter more often
when used in dusty areas. Replace the filter every 2 years or 250
hours of use. See page 11 for the complete maintenance schedule.
A properly maintained air filter will help prevent dirt from entering your
engine. Dirt entering the carburetor can be drawn into small passages
in the carburetor and cause premature engine wear. These small
passages can become blocked, causing starting or running problems.
Operating the engine without an air filter, with a damaged air filter, or
with an improperly installed air cleaner cover will allow dirt to enter the
engine, causing rapid engine wear. This type of damage is not
covered by the DISTRIBUTOR’S LIMITED WARRANTY (page 21).
We recommend the use of a Honda Genuine air filter to ensure it
seals and performs as designed. Using a non-Honda air filter can
result in dirt bypassing the filter, causing damage to the engine or fuel
system.
1. Press down on the cover tabs and remove the cover.
2. Remove the filters from the air cleaner housing.
3. Inspect the filters; replace if damaged.
4. Paper Air Filter: Clean the paper filter by tapping it several times on
a hard surface to remove dirt, or blow compressed air (not
exceeding 30 psi [207 kPa]) through the air filter from the inside.
Never try to brush off dirt; brushing will force dirt into the fibers.
Spark Plug
Replace the spark plug every 2 years or after 250 hours of use.
Required Spark Plug: NGK - BPR6ES
An incorrect spark plug can cause engine damage.
For good performance,
the spark plug must be
properly gapped and
free of deposits.
1. Allow the engine to
cool, disconnect the
spark plug cap, and
remove any dirt
from around the
spark plug area.
2. Remove the spark
plug with a 13/16 in
(21 mm) spark plug
wrench.
3. Inspect the spark plug. Replace it if the electrodes are worn, or if
the insulator is cracked or chipped.
4. Measure the spark plug
electrode gap with a suitable
gauge.
Gap: 0.028 ~ 0.031 in
(0.7 ~ 0.8 mm)
Correct the gap, if necessary,
by carefully bending the side
electrode.
5. Install the spark plug carefully,
by hand, to avoid
cross-threading.
6. After the spark plug seats, tighten with a 13/16 in (21 mm) spark
plug wrench to compress the washer.
– If reinstalling the old spark plug, tighten 1/8 to 1/4 turn after the
spark plug seats.
– If installing a new spark plug, tighten 1/2 turn after the spark
plug seats.
Spark plug torque: 14 ft-lb (20 N·m)
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the
cylinder head.
7. Install the spark plug cap onto the spark plug.
13
Sediment Cup Cleaning
O-RING
(Replace)
FUEL VALVE (OFF)
FILTER
UNDERSIDE OF FUEL VALVE
ALIGN FUEL
FILTER
OPENING
WITH FUEL
INLET
SEDIMENT CUP
4 MM SELF-TAPPING
SCREW
SPARK ARRESTER
DRAIN BOLT
The sediment cup prevents water that may be in the fuel tank from
entering the carburetor. If the engine has not been run for a long time,
the sediment cup should be cleaned.
1. Turn the engine switch to the OFF position.
2. Turn the fuel valve lever to the OFF position.
3. Unscrew the sediment cup using a 10mm wrench and remove the
o-ring and filter.
WARNING
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling
fuel.
• Stop the engine and let it cool before refueling
• Keep heat, sparks, and flame away
• Refuel only outdoors
• Wipe up spills immediately
TRANSPORTING
If the engine has been running, allow it to cool before loading the
generator on the transport vehicle. A hot engine and exhaust system
can burn you and can ignite some materials.
Turn the fuel valve to the OFF position. This will prevent carburetor
flooding and reduce the possibility of fuel leakage.
Two people should lift the generator on and off the transport vehicle
while holding the generator level.
Position the generator so that its base is level on the bed of the
transport vehicle. Tie the generator down with rope or straps. Keep
the tie-down rope or straps away from the controls.
Do not operate the generator while transporting.
STORAGE
4. Clean the sediment cup and filter in a non-flammable or high flash
point solvent.
5. Install the filter by aligning it with the fuel inlet.
6. Install the new o-ring and sediment cup. Tighten securely.
7. Turn the fuel valve lever to the ON position and check for leaks.
Spark Arrester
The spark arrester must be serviced every 100 hours to keep it
functioning as designed.
1. Allow the engine to cool and disconnect the spark plug cap.
2. Remove the 4 mm self-tapping screw and the spark arrester from
the muffler.
3. Check for carbon deposits on the spark arrester and the exhaust
port. Use a brush to remove any carbon deposits from the screen.
Replace the screen if it is torn or damaged.
4. Installation is the reverse of removal. Tighten all hardware
securely.
Proper storage preparation is essential for keeping your generator
trouble free and looking good. To help keep rust and corrosion from
impairing your generator’s function and appearance, and to make the
engine easier to start after storage, follow the instructions described in
this section to:
• Drain or treat the fuel
• Change the oil and coat the engine cylinder
• Clean the generator
• Choose a storage location
Fuel
See “AVOIDING FUEL-RELATED PROBLEMS” on page 19 for a list
of recommended procedures to avoid fuel related problems.
The DISTRIBUTOR’S LIMITED WARRANTY (page 21) does not
cover fuel system damage or engine performance problems resulting
from neglected storage preparation.
Draining the Carburetor
1. Place a suitable gasoline container below the carburetor.
2. Turn the fuel valve lever to the OFF position, loosen the carburetor
drain bolt by turning 1 to 2 turns counterclockwise, and drain the
fuel from the carburetor into a suitable container.
3. After all the fuel has drained into the container, tighten the
carburetor drain bolt securely.
4. Turn the fuel valve lever to the OFF position.
14
Draining the Fuel Tank
OIL
SPARK PLUG
1. Place a suitable container below the sediment cup.
2. Turn the fuel valve lever to the OFF position.
3. Remove the sediment cup (page 14), and then turn the fuel valve
lever to the ON position to drain the fuel from the fuel tank.
4. Install the sediment cup and a new O-ring.
5. Turn the fuel valve lever to the OFF position.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried,
touch up any damaged paint, and coat other areas that may rust with
a light film of oil.
Oil
Change the engine oil (see page 12). Add oil in the engine cylinder to
prevent corrosion.
1. Remove the spark plug (page 13).
2. Pour a teaspoon (5 cc)
of clean engine oil into
the cylinder to keep it
from rusting.
3. Pull the starter rope
several times to
distribute the oil in the
cylinder.
4. Reinstall the spark
plug.
5. Pull the starter rope
slowly until resistance
is felt, and then return the starter grip gently. This will close the
valves so moisture cannot enter the engine cylinder.
Storage Location
If your generator will be stored with gasoline in the fuel tank and
carburetor, it is important to reduce the hazard of gasoline vapor
ignition. Select a well-ventilated dry storage area away from any
appliance that operates with a flame, such as a furnace, water heater,
or clothes dryer. Also avoid any area with a spark-producing electric
motor, or where power tools are operated.
Make sure the fuel valve is in the OFF position to reduce the
possibility of fuel leakage.
Place the generator on a level surface. Tilting can cause fuel or oil
leakage.
With the engine and exhaust system cool, cover the generator to keep
out dust. A hot engine and exhaust system can ignite or melt some
materials. Do not use sheet plastic as a dust cover. A nonporous
cover will trap moisture around the generator, promoting rust and
corrosion.
TROUBLESHOOTING
Engine Will Not Start
Possible CauseCorrection
Fuel valve lever OFFTurn the fuel valve lever ON
(page 6).
Out of fuelRefuel (page 12).
Bad fuel; generator stored without
treating gasoline, or refueled with
bad gasoline
Low oil level caused Oil Alert to
stop engine
Spark plug faulty, fouled, or
improperly gapped
Spark plug wet with fuel (flooded
engine)
Fuel filter clogged, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Loss of Power
Possible CauseCorrection
Air filter is cloggedClean or replace the air filter
Bad fuel; generator stored without
treating gasoline, or refueled with
bad gasoline
Fuel filter clogged, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
No Power at the AC Receptacles
Possible CauseCorrection
Output indicator is OFF, and the
overload alarm is ON
AC circuit protector is trippedCheck the AC load and reset
Refuel with fresh gasoline
(page 19).
Check oil level (page 12). Add
oil as necessary. Turn the
engine switch OFF and then
ON and restart the engine.
Gap or replace the spark plug
(page 13).
Dry and reinstall the spark
plug.
Take the generator to an
authorized Honda servicing
dealer for repair.
(page 13).
Refuel with fresh gasoline
(page 19).
Take the generator to an
authorized Honda servicing
dealer for repair.
Check the AC load. Stop and
restart the engine. (page 9).
Check the cooling air inlet.
Stop and restart the engine.
the circuit protector. (page 6).
Removing from Storage
Check your generator as described in “BEFORE EACH USE” on
page 5.
If the engine cylinder was coated with oil during storage preparation,
the engine may smoke briefly at startup.
Faulty power tool or applianceReplace or repair the power
tool or appliance. Stop and
restart the engine.
Faulty generatorTake the generator to an
authorized Honda servicing
dealer, or refer to the shop
manual. (page 20).
15
TECHNICAL INFORMATION
NOTICE
FRAME SERIAL NUMBER
ENGINE
SERIAL NUMBER
Serial Number Locations
Emission Control System
Source of Emissions
The combustion process produces carbon monoxide, oxides of
nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of
nitrogen is very important because, under certain conditions, they
react to form photochemical smog when subjected to sunlight. Carbon
monoxide does not react in the same way, but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control
systems to reduce the emissions of carbon monoxide, oxides of
nitrogen, and hydrocarbons. Additionally, Honda fuel systems utilize
components and control technologies to reduce evaporative
emissions.
U.S. and California Clean Air Acts, and Canadian
Environment Protection Act
U.S. EPA, California, and Canadian regulations require all
manufacturers to furnish written instructions describing the operation
and maintenance of emissions control systems.
The following instructions and procedures must be followed in order to
keep the emissions from your Honda engine within the emissions
standards.
Tampering and Altering
There are two serial numbers, one for the engine and one for the
generator frame. Record the engine and frame serial numbers in the
spaces below. You will need these serial numbers when ordering parts
and when making technical or warranty inquiries.
Frame serial number: EAAA-______________________________
Engine serial number: GCAAA-____________________________
Date of purchase: _____________________________________
High Altitude Operation
At high altitudes, the standard carburetor air-fuel mixture will be too
rich. Performance will decrease, and fuel consumption will increase. A
very rich mixture will also foul the spark plug and cause hard starting.
Operation at an Altitude that differs from that at which this engine was
certified, for extended periods of time, may increase emissions.
High altitude performance can be improved by specific modifications
to the carburetor. If you always operate your generator at altitudes
above 5,000 feet (1,500 meters), have your servicing dealer perform
this carburetor modification. This engine, when operated at high
altitude with the carburetor modifications for high altitude use, will
meet each emission standard throughout its useful life.
Even with carburetor modification, engine horsepower will decrease
about 3.5% for each 1,000-foot (300-meter) increase in altitude. The
effect of altitude on horsepower will be greater than this if no
carburetor modification is made.
When the carburetor has been modified for high altitude operation,
the air-fuel mixture will be too lean for low altitude use. Operation at
altitudes below 5,000 feet (1,500 meters) with a modified carburetor
may cause the engine to overheat and result in serious engine
damage. For use at low altitudes, have your servicing dealer return
the carburetor to original factory specifications.
16
Tampering is a violation of Federal and California law.
Tampering with or altering the emissions control system may increase
emissions beyond the legal limit. Among those acts that constitute
tampering are:
• Removal or alteration of any part of the intake, fuel, or exhaust
systems
• Altering or defeating the speed-adjusting mechanism to cause the
engine to operate outside its design parameters
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine
inspected and repaired by your servicing dealer.
• Hard starting or stalling after starting
• Rough idle
• Misfiring, backfiring under load, or afterburning
• Black exhaust smoke or high fuel consumption
Replacement Parts
The emissions control systems on your new Honda engine were
designed, built, and certified to conform with EPA, California, and
Canadian emissions regulations. We recommend the use of Honda
Genuine parts whenever you have maintenance done. These
original-design replacement parts are manufactured to the same
standards as the original parts, so you can be confident of their
performance. The use of replacement parts that are not of the original
design and quality may impair the effectiveness of your emissions
control system.
A manufacturer of an aftermarket part assumes the responsibility that
the part will not adversely affect emissions performance. The
manufacturer or rebuilder of the part must certify that use of the part
will not result in a failure of the engine to comply with emissions
regulations.
Maintenance
Follow the Maintenance Schedule on page 11. Remember this
schedule is based on the assumption that your machine will be used
for its designed purpose. Sustained high-load or high-temperature
operation, or use in unusually dusty conditions, will require more
frequent service.
Air Index
An Air Index Information hang tag/label is applied to engines certified
to an emission durability time period in accordance with the
requirements of the California Air Resources Board.
The bar graph is intended to provide you, our customer, the ability to
compare the emissions performance of available engines. The lower
the Air Index, the less pollution.
The durability description is intended to provide you with information
relating the engine’s emission durability period. The descriptive term
indicates the useful life period for the engine’s emission control
system. See your EMISSION SYSTEM WARRANTY (page 22) for
additional information.
Specifications
Generator Features
EB2800iLightweight inverter generator with Eco
Throttle and GFCI receptacles
Dimensions and Weights
Length16.9 in (430 mm)
Width17.6 in (448 mm)
Overall height18.9 in (481 mm)
Descriptive TermApplicable to Emissions
Durability Period
Moderate50 hours (0 ~ 80 cc)
125 hours (greater than 80 cc)
Intermediate125 hours (0 ~ 80 cc)
250 hours (greater than 80 cc)
Extended300 hours (0 ~ 80 cc)
500 hours (greater than 80 cc)
1000 hours (225 cc and greater)
Dry weight66.8 lbs (30.3 kg)
Engine Design and Performance
ModelGC190
Type4-stroke, overhead-cam,
single-cylinder, air-cooled
Displacement11.4 cu in (186 cc)
Bore and stroke2.71 x 1.97 in (69.0 x 50.0 mm)
Compression ratio8.5:1
Ignition systemTransistorized magneto
Generator
TypeA type
AC outputRated voltage120V
Rated frequency60 Hz
Rated current20.8 A
Rated output2.5 kVA
Maximum output2.8 kVA
Maintenance
FuelUnleaded gasoline with a pump
octane rating of 86 or higher containing
no more than 10% ethanol by volume
Capacity: 2.14 US gal (8.1 L)
See “AVOIDING FUEL-RELATED
PROBLEMS” on page 19
Engine OilSAE 10W-30, API SJ or later
Spark Plug Type: NGK - BPR6ES
Valve
clearance
(cold)
* Actual amount will vary due to residual oil in the engine. Always
use the dipstick to confirm the actual level (page 12).
Capacity: 20.0 oz (0.58 L)
Refill amount: 12.0 ~ 13.5 oz
(0.35 ~ 0.40 L)*
Gap: 0.028 ~ 0.031 in (0.7 ~ 0.8 mm)
Intake: 0.15 ± 0.04 mm
Exhaust: 0.20 ± 0.04 mm
page 12
page 13
page 13
Shop
manual
17
Wiring Diagram
18
AVOIDING FUEL-RELATED PROBLEMS
When properly maintained, your Honda generator should provide years of trouble-free operation. This includes the fuel system. However,
gasoline can quickly deteriorate (in as little as 30 days) causing starting or running problems and, in some cases, damage to the fuel system.
Most fuel-related problems can be avoided by following the precautions listed below. Fuel system damage and engine performance problems
resulting from deteriorated gasoline are not covered by the DISTRIBUTOR’S LIMITED WARRANTY (page 21).
Follow These Precautions to Prevent Most Fuel-Related Problems
During the Normal UseReason
Do not use gasoline containing more than 10% ethanol (E10). Not
all automotive gasoline is safe to use in your generator.
Store gasoline in a clean, plastic, sealed container approved for fuel
storage.
Store your fuel supply container away from direct sunlight; if the
container has a vent, keep it closed.
Purchase only enough gasoline to last for 1 to 2 months (about 30 to
60 days).
If you purchase enough gasoline to last for more than 60 days, add
a fuel stabilizer to your storage container when you fill it.
Keep your generator’s fuel tank full of fresh fuel when not in use.
Turn the fuel valve OFF.
Keep the air filter clean and properly serviced. Check it before each
use.
3 to 4 Weeks Before Next UseReason
Keep your generator’s fuel tank full of fresh fuel when not in use.
Turn the fuel valve OFF.
Turn the fuel valve to the OFF position, start the engine and let it run
approximately 3 minutes until the carburetor is empty and the
engine stops.
1 to 3 Months Before Next UseReason
Higher levels of ethanol in gasoline attract water, and can corrode or
damage the fuel system and cause performance problems.
A plastic container eliminates the risk of rust and metallic
contaminants from a metal container entering the fuel system.
Gasoline will deteriorate faster when exposed to air and sunlight.
Gasoline deteriorates with age so try to avoid storing it for long
periods, especially in summer heat.
Fuel stabilizer will extend the shelf life of gasoline, but it will not
reconstitute stale fuel.
If the fuel tank is only partially filled, air in the tank will promote fuel
deterioration.
A properly maintained air filter will help prevent dirt from entering the
carburetor. The small passages inside the carburetor can become
blocked.
If the fuel tank is only partially filled, air in the tank will promote fuel
deterioration.
The small amount of gasoline in your engine’s carburetor will
deteriorate faster than the fuel in the fuel tank due to its small
volume and heat from the engine.
If you did not add fuel stabilizer to your fuel storage container when
you filled it up, fill your generator’s fuel tank with fresh gasoline.
Add fuel stabilizer to the generator’s fuel tank according to the
stabilizer manufacturer’s instructions.
Run the engine outdoors for 10 minutes. This makes sure treated gasoline has replaced untreated gasoline
Turn the fuel valve to the OFF position, start the engine, and let it
run approximately 3 minutes until the carburetor is empty and the
engine stops.
More Than 3 Months Before Next UseReason
Remove the fuel from the carburetor and fuel tank (page 14.) Do not
allow gasoline to remain in your generator’s fuel tank for more than
3 months (about 90 days) of inactivity.
If you have fuel left in your storage container at the end of the operating season, recycle the fuel into your car’s fuel tank or dispose of it
properly.
If the fuel tank is only partially filled, air in the tank will promote fuel
deterioration.
Fuel stabilizer will extend the life of gasoline, but it will not
reconstitute stale gasoline.
throughout the fuel system.
The small amount of gasoline in your engine’s carburetor will
deteriorate faster than the fuel in the fuel tank due to its small
volume and heat from the engine.
All fuel stabilizers have a shelf life. It is good practice to empty the
fuel system for long term inactivity.
19
CUSTOMER INFORMATION
Parts, Service Items & Accessories
Dealer Locator Information
To find an Authorized Honda Servicing Dealer anywhere in the United
States:
Visit www.powerequipment.honda.com and click on Find a Dealer.
Contact an authorized Honda servicing dealer to purchase any of
these (or other) Honda Genuine items for your generator.
Replacement Parts
ItemPart NumberNotes
Spark plug98079-56846NGK (brand) BPR6ES
Air filter 17211-Z8B-901Paper
17218-Z2A-000Foam
Service Items
ItemPart NumberNotes
SAE 10W-30
engine oil
NO-SPILL
gas cans
Fuel stabilizer08732-08008 ounces
NO-SPILL
®
®
is a registered trademark of NoSpill LLC.
08207-10W301 quart
06176-1415-C61-1/4 gallon
06176-1405-C62-1/2 gallon
For short and
long term storage
Accessories
Please contact your servicing Honda dealer or visit
powerequipment.Honda.com/generators/accessories for available
accessories.
How to Contact Honda
Honda Power Equipment dealership personnel are trained
professionals. They should be able to answer any question you may
have. If you encounter a problem that your dealer does not solve to
your satisfaction, please discuss it with the dealership's management.
The Service Manager or General Manager can help. Almost all
problems are solved in this way.
If you are dissatisfied with the decision made by the dealership's
management, contact the Honda Power Equipment Customer
Relations Office. You can write:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, GA 30005-8847
Or telephone: (770) 497-6400 M-F, 8:30 a.m. - 7:00 p.m. ET
When you write or call, please give us this information.
• Model and serial numbers (page 16)
• Name of the dealer who sold the generator to you
• Name and address of the dealer who services your generator
• Date of purchase
• Your name, address, and telephone number
• A detailed description of the problem
Honda Publications
These publications will give you information for maintaining and
repairing your generator.
Owner’s Manual
Keep this owner’s manual handy so you can refer to it at any time.
Consider this owner’s manual a permanent part of the generator;
please give it to the new owner if you resell the generator.
The information and specifications included in this publication were in
effect at the time of approval for printing. American Honda Motor Co.,
Inc. reserves the right, however, to discontinue or change
specifications or design at any time without notice and without
incurring any obligation whatever. No part of this publication may be
reproduced without written permission.
Shop Manual
This manual covers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician. Available through
your Honda dealer or visit www.powerequipment.honda.com and click
on Product Support; then click on Shop Manuals.
Parts Catalog
This manual provides complete, illustrated parts lists, and is available
through your Honda dealer.
Frequently Asked Questions
The Honda Power Equipment web site provides
additional information for users of Honda power
equipment. Visit www.powerequipment.honda.com
and click on FAQs or scan the QR code shown.
20
DISTRIBUTOR’S LIMITED WARRANTY
Honda Power Equipment
This warranty is limited to the following Honda Power Equipment products when
distributed by American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi
Drive, Alpharetta, Georgia 30005-8847, purchased at retail or placed in rental service on
or after January 1, 2010.
LENGTH OF WARRANTY
PRODUCTS COVERED
BY THIS WARRANTY
EB2800i36 months12 months
(1) Private residential: Used in maintaining owner’s primary and/or secondary residence.
Any other use, including but not limited to informal “for hire” use, is considered
commercial/rental/institutional use.
To Qualify for This Warranty:
The product must be purchased in the United States, Puerto Rico, or the U.S. Virgin
Islands from American Honda or a dealer authorized by American Honda to sell
those products. This warranty applies to first retail purchaser and each subsequent
owner during the applicable warranty time period, unless noted otherwise.
What American Honda Will Repair or Replace Under
Warranty:
American Honda will repair or replace, at its option, any part that is proven to be
defective in material or workmanship under normal use during the applicable
warranty time period. Warranty repairs and replacements will be made without
charge for parts or labor. Anything replaced under warranty becomes the property of
American Honda Motor Co., Inc. All parts replaced under warranty will be
considered as part of the original product, and any warranty on those parts will
expire coincident with the original product warranty.
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product, accessory,
replacement part, apparel, or the power equipment on which the
accessory or replacement part is installed, and proof of purchase to any Honda
Power Equipment dealer in the United States, Puerto Rico, or the
U.S. Virgin Islands who is authorized to sell and/or service that product, during the
dealer’s normal business hours. To locate a dealer near you, visit
our web site at PowerEquipment.Honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved;
normally this will resolve the problem. However, if you should require further
assistance, write or call the Power Equipment Customer Relations Department of
American Honda Motor Co., Inc. See “How to Contact Honda” on page 20.
Exclusions:
1. Any damage or deterioration resulting from the following:
• Neglect of the periodic maintenance as specified in this manual
• Improper repair or maintenance
• Operating methods other than those indicated in the product owner’s manual
• The use of non-genuine Honda parts, accessories, lubricants, and fluids other
than those approved by Honda
• Exposure of the product to soot and smoke, chemical agents, bird droppings,
sea water, salt or other corrosive environments
• Collision, fuel contamination or deterioration, neglect, unauthorized alteration,
misuse, incorporation or use of unsuitable attachments or parts
• Normal wear and tear (including, but not limited to, normal fading of painted or
plated surfaces, sheet peeling, and other natural deterioration)
2. Consumable parts: Honda does not warrant parts deterioration due to normal
wear and tear. The following parts are not covered by warranty (unless they are
needed as a part of another warranted repair): spark plug, fuel filter, air cleaner
element, clutch disc, tire, wheel bearing, recoil starter rope, cable, belt, cutter
blade, oil, and grease.
3. Cleaning, adjustment, and normal periodic maintenance work (carburetor
cleaning, engine oil draining, blade sharpening, belt and cable adjustments).
4. Any product that has ever been declared a total loss or sold for salvage by a
financial institution or insurer.
5. Auger and paddle assemblies of snow throwers, tiller tines of roto-tillers, mower
blades and mower deck housings, are specifically not warranted against impact
damage, including but not limited to, abrasive damage.
Disclaimer of Consequential Damage and Limitation of
Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the product,
transportation, commercial loss, or any other incidental or consequential damage.
Any implied warranties are limited to the duration of this written limited warranty.
Some states do not allow limitations on how long an implied warranty lasts and/or
do not allow the exclusion or limitation of incidental or consequential damages, so
the above exclusions and limitations may not apply to you. This warranty gives you
(from date of original retail purchase)
PRIVATE
RESIDENTIAL
COMMERCIAL/RENTAL/
(1)
INSTITUTIONAL
specific legal rights, and you may also have other rights which vary from state to
state.
Honda Parts, Accessories, and Apparel
This warranty is limited to Honda Power Equipment parts, accessories, and apparel when
distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia
30005-8847.
The parts, accessories, or apparel must be purchased from American Honda or a
dealer authorized by American Honda to sell those products in the United States,
Puerto Rico, and the U.S. Virgin Islands. Parts and Accessories must be purchased
for installation on original Honda equipment or engines to be eligible for warranty
coverage. Installing parts and accessories on non-Honda products or engines voids
this warranty. You must be the first retail purchaser. This warranty is not transferable
to subsequent owners.
What American Honda Will Repair or Replace Under
Warranty:
American Honda will repair or replace, at its option, any Honda Power Equipment
parts, accessories, replacement parts, or apparel that are proven to be defective in
material or workmanship under normal use during the applicable warranty time
period. Anything replaced under warranty becomes the property of American Honda
Motor Co., Inc. The warranty on all parts, accessories, and apparel replaced under
warranty will expire coincident with the original warranty on the replaced parts,
accessories, or apparel.
Parts and accessories installed by a dealer who is authorized by American Honda to
sell them will be repaired or replaced under warranty without charge for parts or
labor. If installed by anyone else, parts and accessories will be repaired or replaced
under warranty without charge for parts, but any labor charges will be the
responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any charge.
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment part, accessory,
apparel or the Honda Power Equipment on which the part or accessory is installed,
and proof of purchase to any Honda Power Equipment dealer in the United States,
Puerto Rico, or the U.S. Virgin Islands who is authorized to sell that product, during
the dealer's normal business hours. To locate a dealer near you, visit our web site at
PowerEquipment.Honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved; normally this will
resolve the problem. However, if you should require further assistance, write or call
the Power Equipment Customer Relations Department of American Honda Motor
Co., Inc. See “How to Contact Honda” on page 20.
Exclusions:
This warranty does not extend to parts, accessories, or apparel affected or
damaged by collision, normal wear, use in an application for which the product was
not designed or any other misuse, neglect, incorporation or use of unsuitable
attachments or parts, unauthorized alteration, improper installation, or any causes
other than defects in material or workmanship of the product. Installing parts and
accessories on non-Honda products or engines voids this warranty.
Disclaimer of Consequential Damage and Limitation of
Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the product,
or the power equipment on which the product is installed, transportation,
commercial loss, or any other incidental or consequential damage. Any implied
warranties are limited to the duration of this written warranty. Some states do not
allow limitations on how long an implied warranty lasts and/or do not allow the
exclusion or limitation of incidental or consequential damages, so the above
exclusions and limitations may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
(from date of original retail purchase)
PRIVATE
RESIDENTIAL
COMMERCIAL/RENTAL/
INSTITUTIONAL
PWL50623-V
21
EMISSION SYSTEM WARRANTY
Your new Honda Power Equipment engine complies with the U.S. EPA,
Environment Canada, and State of California (models certified for sale in California
only) emission regulations. American Honda Motor Co., Inc. provides the emission
warranty coverage for engines in the United States and its territories. Honda
Canada Inc. provides the emission warranty for engines in the 13 provinces and
territories of Canada. In the remainder of this Emission Control System Warranty,
American Honda Motor Co., Inc. and Honda Canada Inc. will be referred to as
Honda.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
CALIFORNIA
The California Air Resources Board and Honda are pleased to explain the emission
control system warranty on your 2017 and later Honda Power Equipment engine. In
California, new spark-ignited small off-road equipment engines must be designed,
built, and equipped to meet the state's stringent anti-smog standards. Specific
Honda products that do not meet the California emissions regulations can be
identified by a “Not for sale in California” decal.
OTHER STATES, U.S. TERRITORIES, AND CANADA
In other areas of the United States and in Canada, your engine must be designed,
built, and equipped to meet the U.S. EPA and Environment Canada emission
standards for spark-ignited engines at or below 19 kilowatts.
ALL OF THE UNITED STATES AND CANADA
Honda must warrant the emission control system on your power equipment
engine for the period of time listed below, provided there has been no abuse,
neglect, or improper maintenance of your power equipment engine. Where a
warrantable condition exists, Honda will repair your power equipment engine at
no cost to you including diagnosis, parts, and labor.
Your emission control system may include such parts as the carburetor or fuel
injection system, the ignition system, and catalytic converter. Also included
may be hoses, connectors, and other emission-related assemblies.
OWNER'S WARRANTY RESPONSIBILITY:
As the power equipment engine owner, you are responsible for completing all
required maintenance listed in your owner's manual. Honda recommends that
you retain all receipts covering maintenance on your power equipment engine,
but Honda cannot deny warranty coverage solely for the lack of receipts or for
your failure to ensure that all scheduled maintenance has been completed.
As the power equipment engine owner, you should however be aware Honda
may deny you warranty coverage if your power equipment engine or a part has
failed due to abuse, neglect, improper maintenance, or unapproved
modifications.
You are responsible for presenting your power equipment engine to a Honda
Power Equipment dealer as soon as a problem exists. The emission related
warranty repairs should be completed in a reasonable amount of time, not to
exceed 30 days.
If you have any questions regarding your emission warranty rights and
responsibilities, you should contact the Honda office in your region.
American Honda Motor Co., Inc.
Power Equipment Customer
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
Relations
4900 Marconi Drive
@ahm.honda.com
orHonda Canada Inc.
Power Equipment Customer
Telephone: (888) 946-6329
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
WARRANTY COVERAGE:
Honda power equipment engines sold in the United States and Canada are
covered by this warranty for a period of two years from the date of delivery to
the original retail purchaser or the length of the Honda Distributor’s Limited
Warranty, whichever is longer. This warranty is transferable to each subsequent
purchaser for the duration of the warranty period.
If any emission-related part on your engine is defective, the part will be repaired
or replaced by Honda without charge for diagnosis, parts, or labor. All defective
parts replaced under this warranty become the property of Honda. Only Honda
approved replacement parts may be used in the performance of any warranty
repairs and must be provided without charge to the owner. A list of warranted
parts is on the reverse side of this warranty statement. Normal maintenance
items, such as spark plugs and filters, that are on the warranted parts list are
warranted up to their required replacement interval only.
Honda will also replace other engine components damaged by a failure of any
warranted part during the warranty period.
The use of replacement parts not equivalent to the original parts may impair
the effectiveness of your engine emission control system. If such a
replacement part is used in the repair or maintenance of your engine, and an
authorized Honda dealer determines it is defective or causes a failure of a
warranted part, your claim for repair of your engine may be denied. If the part
in question is not related to the reason your engine requires repair, your claim
will not be denied.
TO OBTAIN WARRANTY SERVICE:
You must, at your own expense, take your Honda Power Equipment engine or
the product on which it is installed, along with your sales registration card or
other proof of original purchase date, to any Honda Power Equipment dealer
who is authorized by Honda to sell and service that Honda product during their
normal business hours. Claims for repair or adjustment found to be caused
solely by defects in material or workmanship will not be denied because the
engine was not properly maintained and used.
If you are unable to obtain emission warranty service or are dissatisfied with
the warranty service you received, contact the owner of the dealership
involved. Normally this should resolve your problem. However, if you require
further assistance, contact the Honda office in your region. Refer to adjacent
column for contact information.
EXCLUSIONS:
Failures other than those resulting from defects in material or workmanship are
not covered by this warranty. This warranty does not extend to emission control
systems or parts that are affected or damaged by owner abuse, neglect,
improper maintenance, misuse, misfueling, improper storage, collision, the
incorporation of, or use of, unsuitable attachments, or the unauthorized
alteration of any part.
This warranty does not cover replacement of expendable maintenance items
made in connection with required maintenance service after the item’s first
scheduled replacement as listed in the maintenance section of the product
owner’s manual, such as: spark plugs and filters.
DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION
OF IMPLIED WARRANTIES:
American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any
responsibility for incidental or consequential damages such as loss of time or
the use of the power equipment, or any commercial loss due to the failure of the
equipment; and any implied warranties are limited to the duration of this written
warranty. This warranty is applicable only where the California, U.S. EPA, or
Environment Canada emission control system warranty regulation is in effect.
Miscellaneous PartsTubing, fittings, seals, gaskets, and clamps
Note: This list applies to parts supplied by Honda and does not cover parts
supplied by the equipment manufacturer. Please see the original
equipment manufacturer’s emissions warranty for non-Honda parts.
* Covered up to the first required replacement only. See the Maintenance
Schedule on
page 11.PWL50975-R
enrichment system), Oxygen sensor, Throttle
body, Engine temperature sensor, Engine control
module, Fuel injector, Fuel regulator, Intake
Carbon canister, Canister mounting brackets,
Fuel strainer, Fuel valve, Fuel pump, Fuel hose
joint, Canister purge hose joint
generator, Crankshaft position sensor, Power coil,
Ignition coil assembly, Ignition control module,
Spark plug cap, Spark plug*
associated with these listed systems.
PARTS
DESCRIPTION:
manifold
assembly, Oil filler cap
22
PRODUCT REGISTRATION
(commercial/rental users)
(check one)
(private, homeowner use)(for-hire use)
Owner's Last Name
Company Name
Address
City
Purchased Via
First Name
Telephone
()
StateZIP Code
Application
Commercial
Serial number
(professional use)
* Dealer ZIP code* Dealer Store number
*If available
E-mail address
Date of Purchase
MONTHYEARDAY
(check one)
In StoreOnline
Non-commercialRental
AA—EA
Print your 7 digit serial number here.
EAAA
#######
Thank you for choosing Honda!
Please register your generator within 30 days of purchase to ensure
you receive important service information in the event of a product
update or recall and for added coverage during certain sales
promotions.
Your information will remain confidential.
It will not be released to any other company or organization.
There are three ways to register, select one:
• Complete and mail the postage paid card shown below
• Complete and submit the on-line form at powerequipment.honda.com
• Scan the QR code below and then complete and submit the on-line
form
1. Go to: powerequipment.honda.com to register your unit.
2. Click on Product Registration.
3. Complete the required information and click Submit.
It’s that simple!
Power Equipment Division
American Honda Motor Co., Inc.
4900 Marconi Dr
Alpharetta GA 30005-9956
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
Product Registration