Operating Profile
Water is ltered to NSF 42 & 53 standards for particulate, chlroine, chloramine, taste and odor using replaceable cartridge ltration. Softener will remove hardness to less than 1/2 gpg when operated in accordance with the operating instructions. The system includes two tanks. This duplex conguration oper­ates with one tank on-line during service. During regeneration cycles, one tank provides water to service and to the regener­ating tank. A water meter initiates system regeneration. The water meter measures the processed volume and is adjustable. Service ow is down-ow and regeneration ow is up-ow.
CB15K Hollow Carbon Filter
The CB15K Hollow Carbon Filter located inside of the WS-55 cabinet is NSF 42 & 53 certied up to 15,000 gallons for the reduction of Chloramine. The lter is replaced based on psi or 15,000 gallon capacity. Maximum working pressure of the lter is 125 psi.
Regeneration Control Valve
The regeneration control valve is top mounted (top of media tank), and manufactured from non-corrosive materials. Control valve does not weigh more than four pounds. Control valve provides service and regeneration control for two media tanks. Inlet and outlet ports accept a quick connect, double o-ring sealed adapter. Interconnection between tanks is made through the regeneration valve with a quick connect adapter. Control valve operates using a minimum inlet pressure of 15 psi. Pres­sure is used to drive all valve functions. No electric hook-up is required. Control valve will incorporate four operational cycles including; service, brine draw, slow rinse, and a combined fast rinse and brine rell. Service cycle operates in a down-ow di­rection. The brine cycle ows up-ow, opposite the service ow, providing a countercurrent regeneration. Control valve contains a xed orice eductor nozzle and self-adjusting backwash ow control. The control valve will prevent the bypass of hard water to service during the regeneration cycle.
WS-55
Conditioning Media
Each softener includes uniform bead cation resin having a mini­mum exchange capacity of 30,000 grains/ft when regenerated with 15.0 lbs/ft. The media is solid, of a proper particle size and contains no plates, shells, agglomerates or other shapes, which might interfere with the normal function of the water softener.
Brine System
A combination salt storage and brine production tank is manu­factured of corrosion resistant, plastic. The brine tank has a chamber to house the brine valve assembly. The brine oat assembly allows for adjustable salt settings and provides for a shut-off to the brine rell. The brine tank includes a safety over­ow connection to be plumbed to a suitable drain.
Salt Alarm
Salt alarm consists of an alarm box and a brine sensor. Brine sensor is mounted internally on the grid plate and operates on the specic gravity of proper brine concentration. An alarm condition is triggered when the concentration falls below ac­ceptable level for more than 15 minutes. The alarm is both an 80-db audible alarm every 3 seconds and a red LED ash every 7 seconds. The alarm box operates on three AA batteries and connects to the brine sensor with a standard 2-wire phone cord (7' phone cord supplied).
MODEL:
Model WS-55
Specications, Details and Dimensions on Back.
WATER SOFTENING SYSTEMS - WS-55
Media Tanks
The tanks are designed for a maximum working pressure of 125 psi and hydrostatically tested at 300 psi. Tanks are made of en­gineered plastic with a 2.5 in. threaded top opening. Each tank is NSF approved. Upper distribution system is of a slot design. Lower distribution system is of a at plate design. Distributors will provide even ow of regeneration water and the collection of processed water.
Model WS-55
Salt Alarm
F20263 – Water Softening Systems – WS-55 Page 1 of 2
Printed On Recycled Pap
WATER SOFTENING SYSTEMS – WS-55
System Components
Filter................................................................................................CB15K
Filter Media........................................................................Hollow Carbon
Filter Capacity....................................................................15,000 Gallons
Filter Dimension........................ ..........................14"W x 9"D x 23 7/8" H
Media Vessel (qty) Size .............................................................(2) 8 x 17”
Media Vessel Construction ........Fiberglass Wrapped Engineered Plastic
Empty Bed Volume .......................................................................0.40 ft
Media Type ....................................................Uniform Bead Cation Resin
Media Volume ...............................................................................0.40 ft
Bed Depth ....................................................................................Packed
Free Board ...................................................................................... None
Riser Tube ...................................................................................1” CPVC
Distributor Upper ........0.012” Slots, Engineered Plastic Basket
Lower ..........0.009” Slots, Stainless Steel Flat Plate
Under bedding .................................................................................None
Regeneration Control ..........................................Non-electric Use Meter
Regeneration Type ............................................................Countercurrent
Meter Type ..................................0.05 - 5.00 gpm Polypropylene Turbine
Inlet Water Quality
Pressure Range .......................................40 – 125 psi Dynamic Pressure
Temperature Range ...............................................................40 – 100o F
pH Range ..................................................................................5 – 10 SU
Free Chlorine Cl2 (Max.) ..............................................................2.0 mg/l
Hardness as CaCO3 (Max.) ...........................................................40 gpg
Chloramine ..................................................................................4.0 mg/l
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartservice.com
3
3
1.75"
28"
Operating Specs
Flow Range (15 / 30 psig) .................................................0.05 – 3.7 gpm
Flow Conguration ..................................................................Alternating
Dimensions (width x depth x height) ...................................20 x 22 x 28”
Alarm Box ...........................................................5.5" w x 1.375" D x 4"H
Weight (Operating / Shipping) .............................................240 / 120 lbs.
Flow Path .....................................................................CB15K - Softener
Connections
Inlet / Outlet Connections .........................................3/4" NPT Flex Hose
Drain Connection ......................................................................0.5” Tube
Brine Line Connection ............................................0.375” Tube (internal)
Overow Connection .................................................................0.5” Tube
Power ...............................................................................................None
Salt Alarm...........................................................................3 AA Batteries
20"
22"
System Part Numbers
WS-55, Compact Cabinet Softener/CB15K...........................913091-124
Brine Tank Options
Tank Description ...................................................................208 Cabinet
Tank Height .........................................................................................28”
Tank Footprint .............................................................................20 x 22”
Material ...........................................................................................HDPE
Salt Capacity ..................................................................................55 lbs.
Regeneration Specifications
Regeneration Volume ...............................................................14 gallons
Regeneration Time ..................................................................11 minutes
Backwash Flow Control ............................................................1.40 gpm
Brine Rell Flow Control ............................................................0.40 gpm
Disc Selection (Compensated Hardness*)
Setting Capacity Efficiency Dosing Meter Disc 1 2 3 4 5 6 7 8
1.4 lbs. 4,818 grains 3,442 gr./lb. 3.5 lbs./ft3 6 13 25 27 30 35 37 40 Gallons/Regeneration: 591 296 166 148 118 99 84 74 Flow during regeneration (@ 15 psig): 5 5 5 5 5 5 5 5 *Compensated hardness in gpg = Hardness + (3 x Fe in mg/l)
As continued product improvement is a policy of Hobart, specications are subject to change without notice.