Hitachi RAD-25NH5, RAD-35NH5, RAD-25NH4, RAD-40NH4 Installation Manual

˚
CH
INDOOR UNIT
SPLIT TYPE AIR CONDITIONER
INDOOR UNIT
Instruction manual Page 1~20
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
Manual de instrucciones Página 81~100
Para obtener el mejor funcionamiento y asegurar años de uso libre de problemas, lea cuidadosamente este manual de instrucciones.
Bedienungsanleitung Seite 21~40
Bitte lesen Sie diese Bedienungsanleitung aufmerksam durch, um durch richtige Bedienung jahrelangen und störungsfreien Betrieb zu gewährleisten.
Manual de instruções Página 101~120
A fim de obter um bom funcionamento e de garantir uma utilização sem falhas durante muitos anos, é favor ler este manual de instruções completamente.
Mode d’emploi Page 41~60
Des performances optimales et un fonctionnement à long terme seront assurés en appliquant les présentes instructions après avoir entièrement lu ce mode demploi.
O‰ËÁ›Â˜ ¯Ú‹Ûˆ˜ ÛÂÏ›‰· 121~140
°И¿ У· В›У·И ВББ˘ЛМ¤УЛ Л О·П‡ЩВЪЛ ‰˘У·Щ‹ ПВИЩФ˘ЪБ›· О·И Л ¯ˆЪ›˜ ‚П¿‚В˜ М·ОЪФЪfiıВЫМЛ ¯Ъ‹ЫЛ ЩЛ˜ Ы˘ЫОВ˘‹˜, ‰И·‚¿ЫЩВ fiПВ˜ ЩИ˜ О¿ЩˆıИ Ф‰ЛБ›В˜.
Manuale di istruzioni Pag. 61~80
Per garantire la migliore prestazione e la più lunga durataleggere attentamente e al completo le seguanti istruzioni.
аМТЪЫНˆЛfl ФУ ˝НТФОЫ‡Ъ‡ˆЛЛ ÒÚ. 141~161
ÑÎfl o·ecÔe˜eÌËfl ÌaËÎyÛ¯Ëx ˝ÍcÔÎyaÚaˆËoÌÌ˚x xapaÍÚepËcÚËÍ Ë ÏÌo„oÎeÚÌeÈ ·eÁoÚÍaÁÌoÈ pa·oÚ˚ o·opy‰o‚aÌËfl Ìeo·xo‰ËÏo ÔoÎÌocÚ¸˛ oÁÌaÍoÏËÚ¸cfl c ‰aÌÌoÈ àÌcÚpy͈ËeÈ Ôo ˝ÍcÔÎyaÚaˆËË.
MODEL
RAD-25NH5 RAD-35NH5
RAD-25NH5 RAD-35NH5
2
WARNING
CAUTION
SAFETY PRECAUTION
Please read the Safety Precaution carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of
Warning and Caution. The “Warning section contains matters
which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The signs indicate the following meanings. (The following are examples of signs.)
Please keep this manual after reading.
Should abnormal situation arise (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock
and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur
if you remove and reinstall the unit yourself improperly.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
PRECAUTIONS DURING OPERATION
This sign in the figure indicates prohibition. Indicates the instructions that must be followed.
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
Please ask your sales agent or qualified technician for the installation of your unit.
Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
Be sure to use the specified piping set for R410A. Otherwise, this may result in
broken copper pipes or faults.
A circuit breaker should be installed depending on the mounting site of the unit.
Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near location where there is flammable gas. The outdoor unit
may catch fire if flammable gas leaks around it. Piping shall be suitable supported with a maximum spacing of 1m between the supports.
Please ensure smooth flow of water when installing the drain hose.
Make sure that a single phase 230V power source is used.
The use of other power sources may cause electrical components to overheat and lead to fire.
PRECAUTIONS DURING INSTALLATION
WARNING
PROHIBITION
CONNECT EARTH LINE
PROHIBITION
PROHIBITION
"OFF"
Avoid an extended period of direct air flow for your health.
Do not put objects like thin rods into the panel of blower and suction side because
the high-speed fan inside may cause danger.
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, please stop operating the unit and turn off the
circuit breaker.
Spray cans and other combustibles should not be located within a meter of the air
outlets of both indoor and outdoor units. As a spray cans internal pressure can be increased by hot air, a rupture may result.
PROHIBITION
PROHIBITION
PROHIBITION
WARNING
PROHIBITION
"OFF"
3
ENGLISH
DEUTSCHFRANÇAISITALIANOSPANISHPORTUGUÊS∂ППЛУИО¿РУССКИЙ
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household
heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Be sure to stop the operation by using the remote controller and turn off the circuit
breaker during cleaning, the high-speed fan inside the unit may cause danger.
Do not place plants directly under the air flow as it is bad for the plants.
Do not climb on the outdoor unit or put objects on it.
Turn off the circuit breaker if the unit is not be operated for a long period.
When operating the unit with the door and windows opened, (the room humidity is
always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
Do not touch the air outlet, bottom surface and aluminum fin of the outdoor
unit. You may get hurt.
Indoor unit cleaning must be performed by authorized personnel only. Consult your
sales agent. Using a commercially available detergent or similar can damage the plastic parts or clog the drain pipe, causing water to drip with potential electric shock hazard.
If the amount of heat in the room is above the cooling or heating capability of the unit
(for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
Do not touch the refrigerant pipe and connecting valve.
Burns may result.
The product shall be operated under the manufacturer specification and not for any
other intended use.
Please ensure that outdoor mounting frame is always stable, firm and without
defect. If not, the outdoor unit may collapse and cause danger.
Do not wash the unit with water or place a water container such as a vase on the
indoor unit. Electrical leakage could be present and cause electric shock.
PROHIBITION
CAUTION
DON'T WET
PROHIBITION
PROHIBITION
PROHIBITION
DONT TOUCH
DONT TOUCH
"OFF"
PRECAUTIONS DURING OPERATION
PROHIBITION
STRICTLY OBSERVE
PRECAUTIONS
PROHIBITION
"OFF"
PROHIBITION
PROHIBITION
PROHIBITION
4
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
FULL DUCT
Discharge grille
Air deflector
Indicator
Suction grille
Filter
Remote controller
Remote controller
Remote controller
Air deflector
Discharge grille
Indicator
Suction grille
Filter
Indicator
Suction grille
Filter
Air deflector
SEMI DUCT NON DUCT
Discharge grille
MULTI-AIR CONDITIONER
With this multi-air conditioner, several indoor units can be connected to one outdoor unit to be driven. You can operate the required number of indoor units.
Combination of operations:
You cannot operate the indoor units in the following combinations.
One unit Other unit
Cooling
Heating Dehumidifying
Circulating (fan)
The indoor unit which is switched on first continues to operate, but other indoor units which is switched on later does not operate while the lamp lights.
To restart an indoor unit which was operated later, stop the indoor unit which was operated first or later and reset the type of operation, then perform operation again.
Adjusting the number of indoor units:
Decrease the number of indoor units to be operated especially when it is very hot or very cold or when you want to reach the preset temperature quickly.
Stopped indoor units:
When an indoor unit is operated in the cooling, heating or dehumidifying mode in one room, the sound of refrigerant flow may be heard from a stopped indoor unit or a stopped indoor unit may become warm. This is because the indoor unit returns refrigerant to the outdoor unit to be ready for operation.
When operation mode is selected:
During automatic operation:
When heating operation is automatically selected for the first indoor unit, the next indoor unit will then start to heat. Also, if cooling or dehumidifying is automatically selected for the first indoor unit, the next indoor unit will also start to cool or dehumidify.
5
ENGLISH
DEUTSCHFRANÇAISITALIANOSPANISHPORTUGUÊS∂ППЛУИО¿РУССКИЙ
MODEL NAME AND DIMENSIONS
MODEL WIDTH HEIGHT DEPTH
RAD-25NH5 RAD-35NH5 750mm (29-17/32") 235mm (9-1/4") 400mm (15-3/4")
(INDOOR UNIT)
TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work. Normally do not use this button.
TIMER lamp This lamp lights when the timer is working.
OPERATION lamp This lamp lights during operation. During heating, the operation indicator may blink, blowing very lightly or totally stopping under the following conditions: (1) During preheating (heating operation)
For about 2~3 minutes after start up.
(2) During defrosting (heating operation)
Defrosting will be performed about once an hour when frost forms on the heat exchanger of the outdoor unit, for 5~10 minutes each time. (If the piping length used is longer than usual, frost will likely to form.)
INDOOR UNIT INDICATORS
6
NAMES AND FUNCTIONS OF EACH PART
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission capability.
After new batteries are inserted into the remote controller, the unit will initially require approximately 10 seconds to respond to commands and operate.
Precautions for use
Do not put the remote controller in the following places.
In direct sunlight
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor, and protect
it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again). This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection.
Signal emitting window/transmission sign
Point this window toward the indoor unit when controlling it. The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
START/STOP button
Press this button to start operation. Press it again to stop operation.
SLEEP button
Use this button to set the sleep timer.
TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)
TIME button
Use this button to set and check the time and date.
RESET buttons
FUNCTION selector
Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to (COOL) and to (FAN) cyclically.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW). (This button allows selecting the optimal or preferred fan speed for each operation mode.)
AUTO SWING button
Controls the angle of the horizontal air deflector.
TIMER control
Use these buttons to set the timer.
OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time.
RESERVE button Time setting reservation.
CANCEL button Cancel time reservation.
AUTO
HEAT
DEHUMIDIFY
COOL
FAN FAN SPEED
LOW MED HI
SLEEPING
STOP (CANCEL)
START (RESERVE)
START/STOP
TIME
TIMER SET
TIMER SELECTOR
ON TIMER OFF TIMER
AUTO SWING
Loading...