Getting Started .............................................................................................................. 25
10.
System Settings ................................................................................................ ............ 26
11.
LED Indicator on Front Panel ........................................................................................ 29
12.
Unpacking and Packing Instructions .............................................................................. 29
EH-TP500 Series
Operating Instructions
VER 1.00
4
Introduction
Introduction
The operational guidelines described below are information which relates to the device, installation,
transportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of EH-TP500 Series operator panels. The
Manual refers to the following models:
EH-TP504
EH-TP507
EH-TP510
EH-TP513
EH-TP515
Operator interface with TFT color 4.3” display touchscreen
Operator interface with TFT color 7” widescreen display touchscreen
Operator interface with TFT color 10.4” display touchscreen
Operator interface with TFT color 13.3” widescreen display touchscreen
Operator interface with TFT color 15” display touchscreen
EH-TP500 Series
Operating Instructions
VER 1.00
5
Safety Guide
CAUTION
!
ATTENTION
!
DANGER
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage.
Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
ATTENTION: indicates a failure to observe safety rules and that deficiency may cause damage.
CAUTION: indicates a failure to observe safety rules and that deficiency may cause defects to the
equipment or inconsistencies.
EH-TP500 Series
Operating Instructions
VER 1.00
6
Product Overview
1.
Product Overview
The Hitachi EH-TP500 Series HMI products combine state-of-the-art features and top performance
with an outstanding design. They are the ideal choice for all demanding HMI applications including
factory and building automation.
The EH-TP500 Series HMI panels have been designed to run the HiMobile software.
Designed for use with HiMobile HMI software.
Full vector graphic support. Native support of SVG graphic objects. Transparency and
alpha blending.
Full object dynamics: control visibility and transparency, move, resize, and rotate any object on
screen. Change properties of basic and complex objects.
TrueType fonts.
Multilanguage applications. Easily create and manage your applications in multiple languages to
meet global requirements. Far East languages are supported. Tools available in HiMobile Studio
support easy third-party translations and help reducing development and maintenance costs of the
application.
Data display in numerical, text, bar-graph, analog gauges and graphic image formats.
Rich set of state-of-the-art HMI features: data acquisition, alarm handling, scheduler and timed
actions (daily and weekly schedulers, exception dates), recipes, users and passwords, RSS feeds,
rotating menus.
Includes support for a wide range of communication drivers for Factory systems.
Multiple drivers’ communication capability.
Remote monitoring and control. Client-Server functionality.
On-line and Off-line simulation with HiMobile Studio.
Powerful scripting language for automating HMI applications. Script debugging improves efficiency
in application development.
Rich gallery of vector symbols and objects.
Optional plug-in modules for fieldbus systems, I/O and controllers.
EH-TP500 Series
Operating Instructions
VER 1.00
7
Standards and Approvals
2.
Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/
EU EMC Directive.
The products have been designed in compliance with:
EN 61000-6-4 EN 55011 Class A
EN 61000-6-2 EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
The installation of these devices into the residential, commercial and light-industrial environments is
allowed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-
3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive
2002/95/EC
In compliance with the above regulations the products are CE marked.
Product Identification
The product may be identified through a plate attached to the rear cover. You will have to know the type
of unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the figure below:
EH-TP504
ETOP504H4P1
04/15
S.N. 00000000000
XXXXXXXXXXXXXXX version id of the product
product model name
product part number
month/year of production
serial number
EH-TP500 Series
Operating Instructions
VER 1.00
8
Technical Specifications
Environmental conditions
Operating temperature (surrounding
0 ÷ +50°C
EN60068-2-14
air temperature)
Storage temperature
-20 ÷ +70°C
EN60068-2-14
Operating and storage humidity
5 ÷ 85 % RH not-condensing
EN60068-2-30
Vibrations
Shock
Protection class
5 ÷ 9 Hz, 7 mm
p-p
9 ÷ 150 Hz, 1 g
± 50 g, 11 ms, 3 pulses per axis
IP66 front panel *
* The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to
the standards shown in the “Environmentalconditions”. Even though the level of resistance unit is
equivalent to these standards, oils that should have no effect on the panel can possibly harm the
unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting
oil are allowed to adhere to the unit for long periods of time. If the front face protection sheet on the
panel becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate
protection measures are suggested.
If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from
the panel, the original level of the protection cannot be guaranteed.
EH-TP500 Series
Operating Instructions
VER 1.00
9
Technical Specifications
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A EN 55011
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3
electromagnetic field immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test± 2 KV dc power port EN 61000-4-4
± 1 KV signal line
Surge immunity test± 0,5 KV dc power port (line to earth) EN 61000-4-5
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances 0.15 ÷ 80 MHz, 10V EN 61000-4-6
inducted by radiofrequency field
Voltage dips, short interruptions and Port: AC mains; Level:
voltage variations immunity test 100% duration: 1 cycle and 250 cycles (50Hz);
40% duration: 10 cycles (50Hz);
70%
duration: 25 cycles (50Hz);
Phase: 0°-180°
Test executed on the 230Vac side of the Exor International S.p.A. Power Supply EN 61000-4-11
Durability information
Backlight service life 40000 Hrs. or more
(LED type) (Time of continuous operation until the brightness of
the backlight reaches 50% of the rated value when the
surrounding air temperature is 25°C) - see Note 1
Front foil 10 years if the surrounding air temperature is 25°C
(without directly exposure to
sunlight or UV ray)
UV Resistance Indoor applications: After 300 hours cycled humidity
Touch screen reliability > 1 million operations
in QUV accelerated weathering, some yellowing and
brittleness may be present. - see Note 2.
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may
degrade backlight quality/reliability/durability.
Note 2: Solvent resistance:
Contact for 1/2 hour at 21°C, No visible effect: Acetone, Butyl Cellosolve, Cyclohexanone, Ethyl Acetate,
Hexane, Isopropyl Alcohol, MEK, Methylene Chloride, Toluene, Xylene
Contact for 24 hours at 49°C, No visible effect: Coffee, Ketchup, Lemon Juice, Mustard (slight yellow
stain), Tea, Tomato juice.
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.