INSTRUCTION MANUAL AND SAFETY INSTRUCTIO NS FOR AIR COMPRESSOR MANUEL D’UTILISATION ET CO NSIGNES DE SÉCURITÉ DU COMPRESSEUR
MANUAL DE INSTRUCCIONES Y INSTRUCCIONES DE SEGURIDAD PARA EL COMPRESOR DE AIRE
EC 510
WARNING
Improper and unsafe use of this compressor can result in death or serious bodily injury! Instruction manual contains important information about product safety. Please read and understand instruction manual before operating the compressor. Please keep instruction manual available for others before they use the compressor.
AVERTISSEMENT
Une utilisation du compresseur de manière incorrecte ou ne respectant pas les consignes de sécurité peut entraîner la mort ou de graves blessures! Manuel d’utilisation renferme des informations importantes relatives à la sécurité. Veu illez lire attentivement manuel d’uti lisation avant de mettre le c ompre sseur en service. Laissez manuel d’utilisation à la disposition des personnes qui vont utiliser le compresseur.
ADVERTENCIA
¡ La utilización inadecuada e insegura de este compresor puede resultar en la muerte o en lesione s se ria s ! Manual de instrucciones contiene información importante sobre la seguridad del producto. Antes de utilizar el compresor, lea y entienda bien manual de instrucciones. Guarde manual de instrucciones as mano para que otras personas puedan leerlo antes de utilizar el compresor.
1
English
- CONTENTS - Page
IMPORTANT INFOR MATION ... .......... .. .......... .. .......... .. ......... ......... ... ......... ... ......... .......... .. .......... ................ ... ..... 3
MEANIN GS OF SI GN AL WORDS. ... .. .......... ......... ... ......... .. .......... .......... .. ......... ... ......... ... ......... ......... ..............…. 3
SAFETY
IMPORTANT SAFETY INSTRUCTIO NS FOR USE OF THE COMPRESSO R.. .. .. .. ......................... .. .. .. .............. 4
REPLACEMENT PARTS ...................................................................................................................................… 5
GROUNDING INSTRUCTIONS…………………………………………………………………………………………… 6 EXTENSION CORD………………………………………………………………………………………………………… 6
OPERATION AND MAINTENANCE
NAME OF PARTS ..... .. .......... .. .......... .. .......... .. .......... ......... ... ......... ... ......... .......... .. .......... .. ...............................… 7
SPECIFICATIONS..............................................................................................................................................… 7
APPLICATIONS........................................................................................................................ ......... ... ......... ... .… 8
PRIOR TO OP ER ATION ... .. .......... ......... ... ......... ... ........ .......... ... ......... ... ......... .. .......... .......... .. ..........................… 8
TRANSPORT ......................................................................................................................... ......... .......... .. ......… 8
OPERATION ....................................................................................................................... ... .. ......... .......... .. ....… 8
MAINTEN A N C E .......... .. .......... ......... ... ......... .. .......... ......... .. .......... .. .......... .. .......... ......... ... ....... .. .......... .. .........….. 9
SERVICE AND REPAIRS ............................................................................................................. ......... .......... .. .. 9
PARTS LIST ....................................................................................................................... .......... .. .......... .. ...….. 25
Français
- TABLE DES MATIÈRES - Page
INFORMATIONS IMPORTANTES...............................................................................................................… . ... 10
SIGNIFICATION DU VOCABULAIRE DE SIGNALISATION............................................................................... 10
SÉCURITÉ
CONSIGNES DE SÉCURITÉ IMPORTANTES POUR L’UTILISATION DU COMPRESSEUR .......................... 11
PIÈCES DE RECHANGE.............................................................................................................. .. .......... ..…..... 1 2
INSTRUCTIONS DE MISE À LA TERRE………………………………………………………… ……… ……… ……. 13 CORDON DE RALLONGE……………………………………………………………………………………………….. 13
UTILISATION ET ENTRETIEN
NOM DES PIÈCES………........................................................................................................................…....... . 1 4
SPECIFICATIONS...................................................................................................................... .......... .. .… . ........ 14
APPLICATION ......................................................................................................................... ......... ... … . .......... . 1 5
AVANT L’UTILISATION......................................................................................................................…. .......... .. . 1 5
TRANSPORT ......................................................................................................................... ......... .… . ......... ... ... 15
UTILISA T ION ......... ... ......... .......... .. .......... .. ......... .......... . .......... ... ......... ... ......... .......... .. ....... ... ........… .......... ........ 15
ENTRET IEN ......... ... ......... .......... .. .......... .. .......... ......... .. .......... ... ......... ... ......... .......... .. ....... ... .......…. .......... ......... 1 6
SERVICE APRÈS-VENTE ET RÉPARATIONS .................................................................................................. 1 6
LISTE DES PIÈCES ................................................................................................................ ...…...... ......... ... ... 25
Español
- ÍNDICE- Pàgina
INFORMA C I ON IM PORTANTE . ......... .......... .. .......... .. ......... .......... .. .......... .. .......... .. .......... ......... ... ....... .. .....….... . 1 7
SIGNIFICADO DE LAS PALABRAS DE SEÑALIZACIÓN .................................................................................. 17
SEGURIDAD
INSTRUCCIONES IMPORTANTES DE SEGURIDAD PARA LA UTILIZACIÓN DEL COMPRESOR................. 18
PIEZAS DE REEMPLAZO..........................................................................................................................….......19
INSTRUCCIONES PARA LA PUESTA A TIERRA. .. .. .. ......................... .. .............. ............................ ............. ...... 20
CABLE PROLONGADOR...................................................................................................................... .......... .. ... 20
OPERACIÓN Y MANTENIMIENTO
NOMENCLATURA............................................................................................................................. .......... …..... 21
ESPECIFICACIONES ................................................................................................................ ... ......... ... ..…..... 2 1
APLICACIONES .................................................................................................................... .. ......... ... ........…. ... 22
ANTES DE LA OPERACIÓN........................................................................................................... .. .......... … .. ... 22
TRANSPORTE ............................................................................................................................... .......... .…...... 22
OPERACIÓN.......................................................................................................................... ......... .......... …....... 22
MANTENIMIENTO ................................................................................................................... .. .......... ..…....... ... 23
SERVICI O Y REPARACI ON E S … . .......... .. .......... .. ........ .......... ... ......... ... ......... .. .......... .......... .. ......... .. ........ .. ....... 23
LISTA DE PIEZAS ................................................................................................................... ......... ... .........… ... 25
2
English
IMPORTANT INFORMATION
Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before operating or maintainin g this comp ressor.
Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.
Basic safety precautions are outlined in the “SAFETY” section of this Instruction Manual and in the sections which contain the operation and maintenance instructions.
Hazards that must be avoided to prevent bodily injury or machine damage are identified by WARNINGS on the compressor and in this Instruction Manual.
Never use this compressor in a manner that has not been specifically recommended by HITACHI, unless you first confirm that the planned use will be safe for you and others.
MEANINGS OF SIGNAL WORDS
WARNING indicates a potentially hazardous situations which, if ignored, could result in death or serious personal injury. CAUTION indicates a potentially hazardous situat ions wh ich, if not avoided, may result in minor or moderate injury, or may
cause machine damage .
NOTE emphasizes essential information.
3
English
IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR
WARNING: Death or serious bodily injury could result from improper or unsafe use of compressor.
To avoid these risks, follow these basic safety instructions:
READ ALL INSTRUCTIONS
1. NEVER TOUCH MOVING PARTS.
Never place your hands, fingers or other body parts near the compressor’s moving parts. Never insert your fingers or other objects into the belt guard ventilator. Such an action invites the danger of injuries or el ectric shoc ks .
2. NEVER OPERATE WITHOUT ALL GUARDS IN PLACE.
Never op erate this c ompressor without all gu ards or saf ety features in place and in proper working order. If maintenance or servicing requires the removal of a guard or safety features, be sure to replace the guard or safety features before resuming operation of the compressor.
3. ALWAYS WEAR PROTECTION.
Risk of injury. Always wear ANSI Z87.1 safety glasses with side shields or equivalent eye prot ection. C ompress ed air must never be aimed at any one or any part of the body. Us e ear protection as air flow noise is loud when draining.
4. PROTECT YOURSELF AG AI NST ELECTRIC SHOCK.
Prevent body contact with grounded surfaces such as pipes, radiators, ranges and refrigeration enclosures. This compressor must be properly grounded.Don’t expose compressor to rain.Never operate the compressor in damp or wet locations. To reduce risk o f electric shock, do not remove cover.
5. DISCONNECT THE COMPRESSOR.
Always disconnect the compressor from the power source and remove the compressed air from the air tank before servicing, inspecting, maintaining, cleaning, replacing or checking any parts.
6. AV O ID UNI NTE NTIO NAL START ING.
Do not carry the compressor while it is connected to its power source or when th e air t an k is fill ed w it h compr essed air. Be sure the knob of the pressure switch in the “OFF” position before connecting the compressor to its power source.
7. STORE COMPRESSOR PROPERLY.
When not in use, the compressor should be stored in indoor dry place. Keep out of reach of children. Lock-out the storage area.
8. KEEP WORK AREA CLEAN.
Cluttered areas invit e injuri es. Clear all work areas of unnec essary tools, debris, furniture, etc.
9. CO NSIDE R WOR K AREA E NV IRO NME NT.
Keep wor k area wel l lit and w ell ventil ated . Risk of f ire or exp losion . Do not carry and operate the compressor or any other electrical devic e near th e s pray ar ea. D o n ot us e c ompr ess or in t he pr esenc e of flammable liquids or gases. Never plac e objects agains t or on top of com pressor. Com pressor produces sparks during operation. Never use compressor in sites containing lacquer, paint, benzine, thinner, gasoline, gases, adhesive agents, and other materials which are combustible or explosive. In order to avoid damaging this compressor, do not allow the unit to be tilted m ore t h an 10 ° w h en op erating.
SAFETY
10. KEEP CHILDREN AWAY.
Do not let visitors contact compressor extension cord. All visit ors sh ou ld be k ept s afely away from work ar ea.
11. DRESS PROPERLY .
Do not wear l oose clot hin g or jewelry. T h ey can be caught in m o vi n g parts. Wear protective hair covering to contain long hair.
12. DON’T ABUSE CORD.
Never yank it to di sconnect fro m receptacle. Keep cord from heat, oi l an d sh ar p edg es .
13. MAINTAI N COMPRESSOR WITH CARE.
Follo w instruction s for lubricating. Inspect cords periodically and if damaged, have repaired by authori zed servic e center. I nspect ext ension c ords period ically an d replace if dama ged.
14. OUTDOOR USE EXTENSI O N CORDS.
When com pr essor is us ed out d oors , use only extensi on c or ds intend ed f or use outdoors an d s o marked.
15. STAY ALERT.
W atch what you are d oing . Us e c ommon s ense. N ev er st and on th e compressor. Do not operate compressor when you are tired. Compressor should never be used by you if you are under the influence of alc ohol , dr u gs or med ication t h at mak es you drowsy.
16. CHECK DAMAGED PARTS AND AIR LEAK.
Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mou nt ing, air leak , and any ot her c ondit ions that m ay aff ect its operati on. A gu ard or oth er part th at is d amag ed sh ould b e pr oper ly repaired or replaced by an authorized service center unless otherwise indicated elsewhere in this Instruction Manual. Have defecti ve pressur e switches replaced by author ized servic e center. Have def ec tive pilot valv e r epl aced b y aut hor iz ed s ervic e cent er. D o not use compressor if switch does not turn it on and off.
17. NEVER USE COMPRESSOR FOR APPLICATIONS OTHER THAN THOSE SPECIFIED.
Never us e compr ess or for app licati ons oth er than t hose s pecifi ed in the Instruction M anual. Never us e compr essed air for br eathing or respiration.
18. HANDLE COMPRESSOR CORRECTLY.
Operate the compressor according to the instructions provided herein. Never allow the compressor to be operated by children, individuals unfamiliar with its operation or unauthorized pe rsonnel.
19. KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY IN PLACE.
Keep all screws, bolts, and covers tightly mounted. Check their conditi ons p er i odically.
20. KEEP MOTOR AIR VENT CLEAN.
The motor air vent must be kept clean so that air can freely flow at all times. Check for dust build-up frequently.
4
English
21. OPERATE COMPRESSOR AT THE RATED VOLTAGE.
Operate the compressor at voltages specified on their nameplates. If using t he c ompr ess or at a hig h er volt ag e th an th e rat ed vol t age, i t will resu lt in abnormall y fast motor revol ution and may d amage the unit and bur n out th e m otor.
22. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR OPERATING ABNORMALLY.
If the compressor appears to be operating unusually, making strange noises or vibration, or otherwise appears defective, stop using it immediat ely and arr ange for r epairs by a Hit achi auth orized ser vice center.
23. DO NOT WIPE PLASTIC PARTS WITH SOLVENT.
Solvents such as gasoline thinner, benzene, carbon tetrachloride, and alcohol may damage and crack plastic parts. Do not wipe them with such solvents. Wipe plastic parts with a soft cloth lightly dampen ed wit h s oapy water and dry thor oughly.
24. USE ONLY GENUINE HITACHI RE PL ACEM ENT PARTS.
Replacement parts not manufactured by Hitachi may void your warrant y and c an l ead t o malf unc tion and r esul ting i nj uries . G enuin e Hitachi parts are av ail ab le from your deal er.
25. DO NOT MODIFY THE COMPRESSOR.
Do not modif y the compr essor. D o not operat e at pressur e or speed in excess of m anufacturer’s recommendat ions. Alwa ys c ontact t he Hitachi authorized service center any repairs. Unauthorized modification may not only impair the compressor performance but may also result in accident or injury to repair personnel who do not have the required knowledge and technical expertise to perform the repair operations c orrectly.
26. PUSH THE KNOB OF PRESSURE SWITCH TO OFF WHEN THE COMPRESSOR IS NOT USED.
W hen th e com pressor is n ot us ed, p ush t he kn ob of the p ress ure switch OFF, dis conn ect it from the pow er sourc e and open the drai n cock to discharge the compressed air from the air tank.
27. NEVER TOUCH HOT SURFACE
To reduc e th e ris k of b urns, d o not t ouch tu bes, heads , c ylind er and motor s.
REPLACEMENT PARTS
When servicing use only identical replacement parts.
Repairs should be conducted only by a Hitachi authorized service center.
28. DO NOT DIRECT AIR STREAM AT BODY.
Risk of injury, do not dir ec t air str eam at persons or an im als .
29. DRAI N TANK
Risk of burs ting. W ater will c ondense in th e air tank. If not drained , water will c orrod e and weak en the air tan k causin g a risk of air tank ruptur e. Drain t ank dai ly or after 4 hour s of us e. To dr ain tank open valve slowly and tilt compressor to empty accumulated water.
30. DO NOT STOP COMPRESSOR BY PULLI NG OUT THE PLUG.
This could result in damage to the unit. Use the “ON/OFF” kn ob of pressur e s witch.
31. MAKE SURE THE COMPRESSOR OUTLET PRESSURE IS SET LOWER T HAN T HE MAXIM UM OPER ATING PRESS URE OF THE TOOL.
Too much air pr essure causes a haz ardous risk of burs ting. Chec k the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
32. THE SAFETY VA LVE MUST WORK PROPERLY.
Risk of b ursti ng. Bef ore st arting t he com press or pull the ring on th e safety valve to make sure the valve moves freely. If the safety valve does not work pr operly, over-pressurization may occ ur, caus ing air tank rupture or an expl os i on.
33. USE OF THIS PRODUCT WILL EXPOSE YOU TO CHEMICALS KNOWN TO THE STATE OF CALIFORNIA.
Some dust created by this product contains chemicals known to State of California to cause cancer, birth defects or other reproduc t i ve h arm. Some e xam p l es of these chem icals are:
- compounds in fertilizers
- compounds in insecticides, herbicides and pesticides
- arsenic and chromium from chemically treated lumber To reduc e your expos ure t o thes e chemic als, wear appr oved s af ety equipm ent such as dust masks th at are spec ially desig ned to filt er out microscopic particles. Use of this product will expose you to chemicals kn own to the State of California to caus e canc er, birth defects and other reproductive harm. Av oi d inh aling vapor s an d dus t, and wash hands after using. This product contains chemicals, includi n g l ead , know n t o the St at e of Cal ifornia t o caus e c ancer, an d birth defects or other reproductive harm. Wash hands after handling.
.
5
English
English
SAFETY - Continued
GROUNDING INTRUCTIONS
This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a three-c onduct or cord and t hree- prong grou nding t ype plug to fit th e proper gr oundin g type r eceptac le. The gr een (or green and yell ow) conductor in th e c or d is t h e groundi n g wire. Never conn ect t h e green (or green and yel low ) wir e to a li ve term inal. If you r unit is f or use on less th an 150 volts , it has a plug t hat l ooks li ke th at sh own in s k etch (A) in Fi gure on th e right. A n adapter , see sk etches (B) and (C), is available for connecting sketch (A) type plugs to two-prong recept acles. The green -colored rigid ear, lug, or the li ke extending from the adapt er mus t b e c onnected to a perm an ent ground, s uch as a properly ground ed outl et b ox.
Note: T he gr oundi ng ad aptor , sk etch ( C), is pr ohi bited in C an ada b y
Canadian Electrical Code Part 1. Therefore, the instructions for its use are n ot app licable in C an ad a.
W e rec omm en d t hat you never d isass embl e t he compressor or try to do any rewiring in the electrical system. Any repairs should be performed only by HITACHI Service Centers or other qualified service organizations. Should you be determined to make a repair yourself, remember that the green colored wire is the “grounding” wire. Nev er connect t his green wir e to a “live” t ermin al. If you repl ac e the plug on the power cord, be sure to connect the green wire only to the grounding (longest) prong on a 3-prong plug. If in doubt, call a qualified electrician and have the receptacle checked for ground.
EXTENSION CORD
Use only thr ee-wire extens ion cords that h ave three-prong gr ounding-type plugs an d three-pole receptacl es that accept th e compr essor’s plug. Replace or repair damaged cord. Make sur e your ext ensi on cord is in good cond ition. W hen using an extens ion cord, be sure t o use one h eavy en ough to c arry the c urrent your product will draw . An und ersiz ed cord w ill caus e a drop in li ne volt age resu lting in l oss of p ower and overh eating. T able s hows the c orrect siz e to use dep endin g on c ord len gth and n ame pl ate am per e ratin g. If in dou bt, us e th e next h eavi er g age. T he sm aller the g age num ber, the h eavie r th e cord.
MINIMUM GAGE FOR CORD SETS
Ampere
More Not More AWG Than Than
0 - 6 18 16 16 14
6 - 10 18 16 14 12 10 - 12 16 16 14 12 12 - 16 14 12 Not Recommended
Rating
Total L ength of Cor d in Feet (Meter)
0 – 25 26 – 50 51 – 100 101 – 150
(0 – 7.6) (7.9 – 15.2) (15.5 – 30.5) (30.8 – 45.7)
WARNING: Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical cord or extension cord.
Inspect all el ec t rical cords re g ul arly. Never use in or near water or in any en vironm ent wh er e electric sh oc k is p oss i bl e.
SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER
USERS OF THIS TOOL!
6
English
OPERATION AND MAINTENANCE
NOTE:
The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor.
Some illustrations in Instruction Manual may show details or attachments that differ from those on your own compressor.
NAME OF PARTS
Quick air coupler
(air outl et)
Pressure gauge (B) indicates the working pressur e
Pressure gauge (A) indicates the pressure in the air tank
Handle
Knob of the pressure switch
Drain cock (discharge tap)
Knob of the
pressure
reducer
Safety valve Motor cooling fan
Tank
Rubber bumper
(Foot)
Fig. 1
SPECIFICATIONS
Model EC 510 Motor
Power Source Running Horse Power Current Tank Capacity 6 gal. (22.7 ltr)
Maximum Pressure 145 PSI (10 bar) Free Air Delivery
at 40 PSI (2.8 bar)
Single-phase, universal Motor Single-phase, 120V AC 60 Hz
1.1 HP (0.8 kW) 8 A
2.8 CFM
(80 ltr/min)
at 90 PSI (6.2 bar)
2 CFM
(56,6 ltr/min)
Lubrication Oil-less
7
English
APPLICATIONS
Air sour ce of the pneumat ic nai ler and stapler.
WARNING
Never use compressor for applications other than compressor for pneumatic nailer and st apl er .
PRIOR TO OPERATION
1. Power source Ensure that the power source to be utilized conforms to the power source requirements specified on the product nameplate.
2. Power switch Ensure t hat the knob of th e pressure s witch is in t he “OFF” positi on (Fig. 2) . If th e plug is c onnect ed to a rec eptacl e while the knob is in the “ON” position, the compressor will start operating immediately and can cause serious injury.
3. Extension cord
4. Confirm the power receptacle
5. Right running position
NOTE:
Knob of the pressure switch
Fig.2
When th e work area is f ar aw ay from the p ower s ource, us e an extens ion cord of suf ficient thic kness and rated capacity (r efer page 6). The extension cord should be kept as short as practicable.
WARNING:
If the power receptacle only loosely accepts the plug, the recept acle must be repair ed. Cont act the nearest el ectric store for repair service. If such a faulty receptacle is used, may cause overheating, resultin g in a s er i ous haz ar d.
Damaged cord must be replaced or repaired.
Position the compressor on a flat surface or one with an inclination of 10° at the most, in a well ventilated area away from atmospheric agents and not in explosive areas (Fig.3).
CAUTION
When operating or storing the compressor, set 4 rubber bumpers downward on the floor (Refer to Fig.1)
In order to avoid damaging the compressor, do not allow the unit to be tilted more than 10° when operating .
OFF
ON
Fig.3
6. Temperature Operating temperatures are between 32°F and 104°F (0°C and 40°C).
CAUTION:
Never operate in temperatures below 32°F (0°C) or above 104°F ( 40°C ).
TRANSPORT
Push the knob of the pressure switch to “OFF” and disconnect it from the power source before move the compressor. Transport the compressor in the correct manner.
OPERATION
1. St art- u p
Insert th e plug into th e receptac le and start th e compress or by
pulling the knob of the pressure switch to “ON” (Refer to Fig. 2).
WARNING
The oper ation of the compressor is automatic and is c ontrolled by the pressur e switch which st ops it when the pressu re in the air-tan k reaches the maximum level and restart it when the air pressure drops during use to the restart level.
The motor of the compr essor is fit ted with a th ermal prot ection wit h automat ic reset, which stops the compr essor when t he temper ature is too high. Should this be tripped, the compressor will restart automat ically aft er c ool off .
CAUTION:
2. Adj us tm en t of wor k in g pressure
Unlock the knob of the pressure reducer pulling it up, adjust the pressure to the required level by turning the knob clockwise to increase and counterclockwise to decrease. A pressure gauge (B) is provided to know when the required pressur e is r each ed, loc k the knob by pus hing i t dow n fir mly (Ref er to Fig. 4). When ad justing the p ressur e, ch eck an d make s ure th at a pr essure gauge f or th e tank h as th e pressu re l evel th at is higher t han t hat of the pressure to be adjusted. It is als o imp erati ve that you m ake ad just ment b y slowl y star ting u p the pressure from the level that is lower than the press ure to be adjusted.
Do not stop or start the compressor by use of the plug. Always use “ON/OFF” knob located on the pressure switch.
Wear appropriate personal hearing protection during use. Under some conditions and duration of u se , noi s e from this product may contribute to hearing loss.
8
English
WARNING:
Check the manufacturer’s maximum pressure rating for nailers, staplers and access orie s. Co mpr essor out let pr ess ure must be regulat ed so as to nev er exceed the maximum pressure rating of the nailers, staplers and accessories.
Pressure gauge
Knob of the pressure switch
(B) indicates the wo rking pre ssure
Pressure gauge (A) indicates the pressure in the air tank
Knob of the pressure reducer
3. Shutdown (1) Pus h th e kno b of the pr ess ur e swit ch t o “O FF” ( Ref er t o Fig . 1
and Fig. 2). (2) Unplug the plug from power source. (3) Open the drain cock located at the lower part of the tank (Fig. 5).
WARNING
Risk of bursting. When the tank gets corroded, there is a risk of breakdown. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. Drai n tan k daily or aft er 4 hours of use. The drain contains moisture in the air, abr asion partic les, rust, etc. To drain tank open valve slowly and tilt compressor to empty accumulated water. Keep face and eyes away from drain cock.
LOCK
UNLOCK
Fig.4
1. Draining tank Drain tank daily or after 4 hours of use. Open drain cock and tilt compressor to empty accumulated water (Refer to Fig. 5).
SERVICE AND REPAIRS
All quality compressors will eventually require servicing or replacement of parts because of wear from normal use. To assure that onl y auth o rized replacement part s will be used, all service and repairs must be performed by a HITACHI AUTHORIZED SERVICE CENTER, only.
NOTE: Specifications ar e subject to change witho ut any obligation on the part of the HITACHI.
Tank
Drain cock (discharge tap)
Fig.5
MAINTENANCE
WARNING:
9
Disconnect the compressor from the power source and remove the compre ssed air fr om the ai r tank bef ore performing th e maintenance operat ions. Allow the compressor to cool before performing the m aint en an ce op erat ion s.