INSTRUCTION MANUAL AND SAFETY INSTRUCTIONS FOR AIR COMPRESSOR
MANUEL D’UTILISATION ET CONSIGNES DE SÉCURITÉ DU COMPRESSEUR
MANUAL DE INSTRUCCIONES Y INSTRUCCIONES DE SEGURIDAD PARA EL COMPRESOR DE AIRE
MODEL
MODÈLE
MODELO
EC 119
WARNING
Improper and unsafe use of this compressor can result in death or serious bodily injury!
This manual contains important information about product safety.
Please read and understand this manual before operating the compressor.
Please keep this manual available for others before they use the compressor.
AVERTISSEMENT
Une utilisation du compresseur de manière incorrecte ou ne respectant pas les consignes de sécurité peut
entraîner la mort ou de graves blessures!
Ce manuel renferme des informations importantes relatives à la sécurité.
Veuillez lire attentivement toutes les instructions avant de mettre le compresseur en service.
Laissez ce manuel à la disposition des personnes qui vont utiliser le compresseur.
ADVERTENCIA
¡La utilización inadecuada e insegura de este compresor puede resultar en la muerte o en lesiones serias!
Este manual contiene información importante sobre la seguridad del producto.
Antes de utilizar el compresor, lea y entienda bien este manual.
Guarde este manual a disposición para que otras personas puedan leerlo antes de utilizar el compresor.
— 1 —
English
English
IMPORTANT INFORMATION ...............................3
MEANINGS OF SIGNAL WORDS ........................ 3
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
FOR USE OF THE COMPRESSOR ........4
REPLACEMENT PARTS ........................................6
SERVICIO Y REPARACIONES ............................35
LISTA DE PIEZAS ................................................36
— 2 —
English
IMPORTANT INFORMATION
Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before
operating or maintaining this compressor.
Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety
rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and
by observing appropriate safety procedures.
Basic safety precautions are outlined in the “SAFETY” section of this Instruction Manual and in the sections which contain
the operation and maintenance instructions.
Hazards that must be avoided to prevent bodily injury or machine damage are identified by WARNINGS on the compressor
and in this Instruction Manual.
Never use this compressor in a manner that has not been specifically recommended by HITACHI, unless you first confirm
that the planned use will be safe for you and others.
MEANINGS OF SIGNAL WORDS
WARNING indicates a potentially hazardous situations which, if ignored, could result in death or serious injury.
CAUTION indicates a potentially hazardous situations which, if not avoided, may result in minor or moderate injury, or may
cause machine damage.
NOTE emphasizes essential information.
— 3 —
English
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
FOR USE OF THE COMPRESSOR
WARNING:
Death or serious bodily injury could result from improper or unsafe use of compressor.
To avoid these risks, follow these basic safety instructions:
READ ALL INSTRUCTIONS
1. NEVER TOUCH MOVING PARTS.
Never place your hands, fingers or other body parts
near the compressor’s moving parts.
Never insert your fingers or other objects into the
housing's ventilator. Such an action invites the danger
of injuries or electric shocks.
2. NEVER OPERATE WITHOUT ALL GUARDS IN PLACE.
Never operate this compressor without all guards or
safety features in place and in proper working order. If
maintenance or servicing requires the removal of a
guard or safety features, be sure to replace the guard
or safety features before resuming operation of the
compressor.
3. ALWAYS WEAR PROTECTION.
Risk of injury. Always wear ANSI Z87.1 safety glasses
or equivalent eye protection. Compressed air must
never be aimed at anyone or any part of the body.Use
ear protection as air flow noise is loud when draining.
4. PROTECT YOURSELF AGAINST ELECTRIC SHOCK.
Prevent body contact with grounded surfaces such as
pipes, radiators, ranges and refrigeration enclosures.
This compressor must be properly grounded. Never
operate the compressor in damp or wet locations.
To reduce risk of electric shock, do not remove cover.
5. DISCONNECT THE COMPRESSOR.
Always disconnect the compressor from the power
source and remove the compressed air from the air
tank before servicing, inspecting, maintaining,
cleaning, replacing or checking any parts.
6. AVOID UNINTENTIONAL STARTING.
Do not carry the compressor while it is connected to
its power source or when the air tank is filled with
compressed air. Be sure the knob of the pressure
switch in the “OFF” position before connecting the
compressor to its power source.
7. STORE COMPRESSOR PROPERLY.
When not in use, the compressor should be stored in
indoor dry place. Keep out of reach of children. Lockout the storage area.
8. KEEP WORK AREA CLEAN.
Cluttered areas invite injuries. Clear all work areas of
unnecessary tools, debris, furniture, etc.
9. CONSIDER WORK AREA ENVIRONMENT.
Risk of electric shock. Don’t expose compressor to
rain. Don’t use compressor in damp or wet locations.
Keep work area well lit and well ventilated.
Risk of fire or explosion. Do not carry and operate the
compressor or any other electrical device near the
spray area. Don’t use compressor in the presence of
flammable liquids or gases.
Compressor produces sparks during operation. Never
use compressor in sites containing lacquer, paint,
benzine, thinner, gasoline, gases, adhesive agents,
and other materials which are combustible or
explosive.
In order to avoid damaging this compressor, do not
allow the unit to be tilted more than 10º when
operating.
10. KEEP CHILDREN AWAY.
Do not let visitors contact compressor extension cord.
All visitors should be kept safely away from work
area.
11. DRESS PROPERLY.
Do not wear loose clothing or jewelry. They can be
caught in moving parts.
Wear protective hair covering to contain long hair.
12. DON’T ABUSE CORD.
Never yank it to disconnect from receptacle.
Keep cord from heat, oil and sharp edges.
.
13. MAINTAIN COMPRESSOR WITH CARE.
Follow instructions for lubricating.
Inspect cords periodically and if damaged, have
repaired by authorized service center. Inspect
extension cords periodically and replace if damaged.
14. OUTDOOR USE EXTENSION CORDS.
When compressor in used outdoors, use only
extension cords intended for use outdoors and so
marked.
15. STAY ALERT.
Watch what you are doing. Use common sense. Do
not operate compressor when you are tired.
Compressor should never be used by you if you are
under the influence of alcohol, drugs or medication
that makes you drowsy.
— 4 —
English
16. CHECK DAMAGED PARTS AND AIR LEAK.
Before further use of the compressor, a guard or
other part is damaged should be carefully checked to
determine that it will operate properly and perform
its intended function. Check for alignment of moving
parts, binding of moving parts, breakage of parts,
mounting, air leak, and any other conditions that may
affect its operation.
A guard or other part that is damaged should be
properly repaired or replaced by an authorized service
center unless otherwise indicated elsewhere in this
Instruction Manual.
Have defective pressure switches replaced by
authorized service center.
Do not use compressor if switch does not turn it on
and off.
17. NEVER USE COMPRESSOR FOR APPLICATIONS
OTHER THAN THOSE SPECIFIED.
Never use compressor for applications other than
those specified in the Instruction Manual.
18. HANDLE COMPRESSOR CORRECTLY.
Operate the compressor according to the instructions
provided herein. Never allow the compressor to be
operated by children, individuals unfamiliar with its
operation or unauthorized personnel.
19. KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY
IN PLACE.
Keep all screws, bolts, and covers tightly mounted.
Check their conditions periodically.
20. KEEP MOTOR AIR VENT CLEAN.
The motor air vent must be kept clean so that air can
freely flow at all times. Check for dust build-up
frequently.
21. OPERATE COMPRESSOR AT THE RATED
VOLTAGE.
Operate the compressor at voltages specified on their
nameplates.
If using the compressor at a higher voltage than the
rated voltage, it will result in abnormally fast motor
revolution and may damage the unit and burn out the
motor.
22. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE
OR OPERATING ABNORMALLY.
If the compressor appears to be operating unusually,
making strange noises or vibration, or otherwise
appears defective, stop using it immediately and
arrange for repairs by a Hitachi authorized service
center.
23. DO NOT WIPE PLASTIC PARTS WITH SOLVENT.
Solvents such as gasoline, thinner, benzine, carbon
tetrachloride, and alcohol may damage and crack
plastic parts. Do not wipe them with such solvents.
Wipe plastic parts with a soft cloth lightly dampened
with soapy water and dry thoroughly.
24. USE ONLY GENUINE HITACHI REPLACEMENT PARTS.
Replacement parts not manufactured by Hitachi may
void your warranty and can lead to malfunction and
resulting injuries. Genuine Hitachi parts are available
from your dealer.
25. DO NOT MODIFY THE COMPRESSOR.
Do not modify the compressor. Always contact the
Hitachi authorized service center any repairs.
Unauthorized modification may not only impair the
compressor performance but may also result in
accident or injury to repair personnel who do not have
the required knowledge and technical expertise to
perform the repair operations correctly.
26. PUSH THE KNOB OF THE PRESSURE SWITCH TO OFF
WHEN THE COMPRESSOR IS NOT USED.
When the compressor is not used, push the knob of
the pressure switch OFF, disconnect it from the power
source and open the drain cock to discharge the
compressed air from the air tank.
27. NEVER TOUCH HOT SURFACE.
To reduce the risk of burns, do not touch tubes, heads,
cylinder and motors.
28. DO NOT DIRECT AIR STREAM AT BODY.
Risk of injury, do not direct air stream at persons or
animals.
Never use compressed air for breathing or respirators.
29. DRAIN TANK.
Risk of bursting. Water will condense in the air tank. If
not drained, water will corrode and weaken the air
tank causing a risk of air tank rupture.
Drain tank daily or after 4 hours of use.
To drain tank open valve slowly and tilt compressor to
empty accumulated water.
30. DO NOT STOP COMPRESSOR BY PULLING OUT
THE PLUG.
This could result in damage to the unit.
Use the “ON/OFF” knob of pressure switch.
31. MAKE SURE THE COMPRESSOR OUTLET PRESSURE
IS SET LOWER THAN THE MAXIMUM OPERATING
PRESSURE OF THE TOOL.
Too much air pressure causes a hazardous risk of
bursting. Check the manufacturer's maximum
pressure rating for air tools and accessories. The
regulator outlet pressure must never exceed the
maximum pressure rating.
32. DO NOT ATTEMPT TO OPERATE THIS
COMPRESSOR WITHOUT FIRST ADDING OIL TO THE
CRANKCASE.
The compressor is shipped without oil in the
crankcase.
Serious damage can result from even limited
operation unless filled with oil and broken in correctly.
Make sure to closely follow initial prior to operation
procedures.
— 5 —
English
33. THE SAFETY VALVE MUST WORK PROPERLY.
Risk of bursting. Before starting the compressor pull
the ring on the safety valve to make sure the valve
moves freely. If the safety valve does not work
properly, over-pressurization may occur, causing air
tank rupture or an explosion.
REPLACEMENT PARTS
When servicing use only identical replacement parts.
Repairs should be conducted only by a Hitachi authorized service center.
34. USE OF THIS PRODUCT WILL EXPOSE YOU TO
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA.
Use of this product will expose you to chemicals
known to the State of California to cause cancer, birth
defects and other reproductive harm. Avoid inhaling
vapors, and wash hands after using.
— 6 —
SAFETY — Continued
GROUNDING INSTRUCTIONS
This compressor should be grounded while in use to protect the
operator from electric shock. The compressor is equipped with a
three-conductor cord and three-prong grounding type plug to fit the
proper grounding type receptacle. The green (or green and yellow)
conductor in the cord is the grounding wire. Never connect the
green (or green and yellow) wire to a live terminal. If your unit is for
use on less than 150 volts, it has a plug that looks like that shown in
sketch (A) in Figure on the right. An adapter, see sketches (B) and
(C), is available for connecting sketch (A) type plugs to two-prong
receptacles. The green-colored rigid ear, lug, or the like extending
from the adapter must be connected to a permanent ground, such
as a properly grounded outlet box.
Note: The grounding adaptor, sketch (C), is prohibited in Canada
by Canadian Electrical Code Part 1. Therefore, the
instructions for its use are not applicable in Canada.
We recommend that you never disassemble the compressor or try to
do any rewiring in the electrical system. Any repairs should be
performed only by HITACHI Service Centers or other qualified service
organizations. Should you be determined to make a repair yourself,
remember that the green colored wire is the “grounding” wire. Never
connect this green wire to a “live” terminal. If you replace the plug on the
power cord, be sure to connect the green wire only to the grounding
(longest) prong on a 3-prong plug.
If in doubt, call a qualified electrician and have the receptacle checked
for ground.
Ground
Blade
Cover of Grounded Outlet box
(B)
Adapter
Grounding Means
(C)
English
Cover of Grounded
Outlet box
(A)
EXTENSION CORD
Use only three-wire extension cords that have three-prong grounding-type plugs and three-pole receptacles that accept the
compressor’s plug. Replace or repair damaged cord.
Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and
overheating. Table shows the correct size to use depending on cord length and name plate ampere rating. If in doubt, use
the next heavier gage. The smaller the gage number, the heavier the cord.
WARNING: Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical cord or
extension cord. Inspect all electrical cords regularly. Never use in or near water or in any environment
where electric shock is possible.
SAVE THESE INSTRUCTIONS
AND
MAKE THEM AVAILABLE TO
OTHER USERS OF THIS TOOL!
— 8 —
OPERATION AND MAINTENANCE
NOTE:
The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of
the compressor.
Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own
compressor.
NAME OF PARTS
Drain cock
Intake filter
Tank
English
Casing cover
Drain cap
Cylinder
Dipstick
Drain cock
Pressure gauge (A)
indicates the pressure
in the air tank
Tank
Joint (air outlet)
Knob of the pressure reducer
Pressure gauge (B)
indicates the working pressure
Head
Switch of thermal protecter
Fig. 1
— 9 —
Knob of the pressure switch
Motor
English
SPECIFICATIONS
ModelEC119
MotorSingle-Phase, Induction Motor
Power SourceSingle-Phase, 120V AC 60Hz
Output Power
Current15.0 A
Tank Capacity
Maximum Pressure
at 40 PSI5.3 CFM
(2.8 bar) (150 ltr/min)
Free Air
Delivery
LubricationOil
ACCESSORY
at 90 PSI4.4 CFM
(6.2 bar) (125 ltr/min)
at 100 PSI4.0 CFM
(6.9 bar)
PRIOR TO OPERATION
2 HP
(1.5 KW)
4 gal.
(15.1 ltr)
125 PSI
(8.6 bar)
(113 ltr/min)
1. Power source
WARNING:Accessory other than these shown
below can lead to malfunction and
resulting injuries.
Ensure that the power source to be utilized conforms
to the power source requirements specified on the
product nameplate.
STANDARD ACCESSORY
Dipstick - - - - - - - - - - - - - - 1
APPLICATIONS
䡬 Air source of the pneumatic nailer and stapler.
WARNING: Never use compressor for
applications other than compressor
for pneumatic nailer and stapler.
2. Power switch
Ensure that the knob of the pressure switch is in the
“OFF” position (Fig. 2). If the plug is connected to a
receptacle while the knob is in the “ON” position, the
compressor will start operating immediately and can
cause serious injury.
Knob of the pressure switch
Fig. 2
3. Extension cord
When the work area is far away from the power
source, use an extension cord of sufficient thickness
and rated capacity (refer page 7). The extension cord
should be kept as short as practicable.
WARNING: Damaged cord must be replaced or
repaired.
— 10 —
4. Confirm the power receptacle
If the power receptacle only loosely accepts the plug,
the receptacle must be repaired. Contact the nearest
electric store for repair service.
If such a faulty receptacle is used, may cause
overheating, resulting in a serious hazard.
5. Dipstick insertion and oil level check
Use a screwdriver or similar tool to remove the plastic
cap on the lower part of the cylinder (Fig. 3).
Cylinder
Plastic cap
English
and Fig. 6). The screw size of the joint is 3/8". Use an
air coupler which has the same screw size.
7. Right running position
Position the compressor on a flat surface or one with
an inclination of 10º at the most, in a well ventilated
area away from atmospheric agents and not in
explosive areas (Fig. 5).
CAUTION : In order to avoid damaging the
compressor, do not allow the unit to
be tilted more than 10º when
operating.
Fig. 5
Fig. 3
Insert the accessory dipstick all the way to the bottom.
Remove the dipstick and make sure the oil level is
within the range of the dipstick notches (Fig. 4).
Dipstick
Air vent
MAX.
MIN.
Fig. 4
WARNING:Drain tank to release air pressure
before removing the dipstick.
WARNING:Make sure air vent in dipstick is free
from debris. If air vent is blocked
pressure can build in crankcase
causing damage to compressor and
possible personal injury.
When the oil volume is insufficient, refer to the section
“Oil change-oil topping off” on page 13 for a description of how to supply the oil.
6. Air coupler installation
Screw in the air coupler to the joint (Refer to Fig. 1
TRANSPORT
Push the knob of the pressure switch to "OFF" and
disconnect it from the power source before move the
compressor. Transport the compressor in the correct
manner.
OPERATION
1. Start up
Insert the plug into the receptacle and start the
compressor by pulling the knob of the pressure switch
to “ON” (Refer to Fig. 2).
WARNING: Do not stop or start the compressor
by use of the plug. Always use “ON/
OFF” knob located on the pressure
switch.
The operation of the compressor is automatic and is
controlled by the pressure switch which stops it when
the pressure in the air-tank reaches the maximum
level and restart it when the air pressure drops during
use to the restart level.
The motor of the compressor is fitted with a thermal
protection with manual reset (push-button), which
stops the compressor when the temperature is too
high. Should this be tripped, the compressor will
restart only if reset is done.
2. Adjustment of working pressure
Unlock the knob of the pressure reducer pulling it up,
adjust the pressure to the required level by turning the
knob clockwise to increase and counterclockwise to
decrease.
A pressure gauge (B) is provided to know when the
required pressure is reached, lock the knob by
pushing it down firmly (Refer to Fig. 6).
— 11 —
English
When adjusting the pressure, check and make sure
that a pressure gauge for the tank has the pressure
level that is higher than that of the pressure to be
adjusted.
It is also imperative that you make adjustment by
slowly starting up the pressure from the level that is
lower than the pressure to be adjusted.
WARNING: Check the manufacturer’s maximum
pressure rating for nailers, staplers
and accessories. Compressor outlet
pressure must be regulated so as to
never exceed the maximum pressure
rating of the nailers, staplers and
accessories.
Knob of the pressure reducer
Pressure gauge (B) indicates
the working pressure
3. Shutdown
(1) Push the knob of the pressure switch to “OFF”
(Refer to Fig. 1 and Fig. 2).
(2) Unplug the plug from power source.
(3) Open the drain cock located at the lower part of
the tank (Fig. 7).
Drain cock
Joint
Pressure gauge (A)
indicates the pressure in
the air tank
Fig. 6
(2) If the extension cord does not conform to the
specifications given on page 7 replace with an
extension cord such as that shown on page 7. If
the capacity of the power supply is insufficient,
increase the power supply capacity to remove the
cause of a flow of excessive current (over-current).
(3) Wait approximately 5 minutes, then press the
reset switch of the thermal protector (Fig. 8).
(4) Start up. If the motor still stops during operation,
please contact the service center.
Switch of thermal protector
Fig. 8
MAINTENANCE
WARNING:
1. Cleaning the intake filter
Remove the intake filter (Refer to Fig. 1) every 50
hours or once a week and clean the inside of the
intake filter and the filter element with compressed air
(Fig. 9).
Use a phillips screwdriver to disassemble intake filter.
Disconnect the compressor from the
power source and remove the
compressed air from the air tank
before performing the maintenance
operations. Allow the compressor to
cool before performing the
maintenance operations.
WARNING: Never clean filter element with a
flammable liquid or solvent.
Tank
Fig. 7
4. About the thermal protector
The thermal protector operates to stop the motor
when a problem such as a motor overload, etc.,
occurs. If the motor should stop during operation,
proceed as follows.
(1) Push the pressure switch knob to the "OFF"
position and disconnect the plug from the
receptacle (Fig. 2).
CAUTION : Do not operate without the intake
filter.
Filter element
Intake filter
Fig. 9
NOTE: Replace the filter element when it becomes dirty.
— 12 —
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.