4.2.6 HIT RE 500 Epoxy Adhesive Anchor
4.2.6.4 Installation Instructions
1. Drill anchor hole using carbide or diamond core bits.
5. Screw on static mixer. 6. Put holder into dispenser and
2. Clean hole with a nylon or wire brush. Proper hole cleaning is essential. For core bits, flush hole clean with water then immediately remove standing water.
card the first three trigger pulls of adhesive from each refill pack.
Rod
Insert
dis-
3. Insert air nozzle to bottom of hole and blow out hole using a pump, or compressed air. For underwater holes, flush hole with clean water after brushing.
7. Inject adhesive into hole starting at the bottom until 1/2 to 2/3 full. Use mixer filler tube extensions when needed to reach the hole bottom.
4. Insert refill pack into holder. Remove cap covering threaded projection.
8. Unlock dispenser.
T
max
Rebar
9. Insert rod, threaded insert or rebar. Twist during installation.
172 Hilti, Inc. (US) 1-800-879-8000 | www
T
max
10. Fastener may be adjusted during specified gel time.
.us.hilti.com
I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www
11. Do not disturb anchor between specified gel time and initial cure time. At the initial cure time the fastener has 25% of full working load. Work may proceed (e.g. tying rebar,setting steel) which will not exceed 25% of the full working load. Do not torque anchor.
12. After full cure time, apply speci­fied torque as required to secure items to be fastened. Do not exceed maximum torque specified.