HIKVISION DS-1H05 User Manual

DS-1H05 Ethernet-over-Coax Extender
User Manual
User Manual of Ethernet-over-Coax Extender
This manual is applicable to DS-1H05-T, DS-1H05-T/E and DS-1H05-R Ethernet-over-Coax Extender.
This manual may contain several technically incorrect places or printing errors, and the content is subject to
change without notice. The updates will be added into the new version of this manual. We will readily improve or
update the products or procedures described in the manual.
1
User Manual of Ethernet-over-Coax Extender
Safety Warnings and Cautions
Please pay attention to the following warnings and cautions:
Hazardous Voltage may be present: Special measures and precautions must be taken
when using this device. Some potentials (voltages) on the device may present a hazard to
the user. This device should only be used by Employees from our company with knowledge
and training in working with these types of devices that contain live circuits.
Power Supply Hazardous Voltage: AC mains voltages are present within the power supply assembly. This device
must be connected to a UL approved, completely enclosed power supply, of the proper rated voltage and current.
No user serviceable parts inside the power supply.
System Grounding (Earthing): To avoid shock, ensure that all AC wiring is not exposed and that the earth
grounding is maintained. Ensure that any equipment to which this device will be attached is also connected to
properly wired grounded receptacles and are approved medical devices.
Power Connect and Disconnect: The AC power supply cord is the main disconnect device
to mains (AC power).The socket outlet shall be installed near the equipment and shall be
readily accessible.
Installation and Maintenance: Do not connect/disconnect any cables to or perform
installation/maintenance on this device during an electrical storm.
2
User Manual of Ethernet-over-Coax Extender
Power Cord Requirements: The connector that plugs into the wall outlet must be a grounding-type male plug
designed for use in your region. It must have certification marks showing certification by an agency in your region.
The connector that plugs into the AC receptacle on the power supply must be an IEC 320, sheet C13, female
connector. See the following website for more information http://kropla.com/electric2.htm.
Lithium Battery: This device contains a Lithium Battery. There is a risk of explosion if the
battery is replaced by an incorrect type. Dispose of used batteries according to the
vendor’s instructions and in accordance with local environmental regulations.
Perchlorate Material: Special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate. This notice is required by California Code
of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This
device includes a battery which contains perchlorate material.
Taiwan battery recycling:
Please recycle batteries.
Thermal and Mechanical Injury: Some components such as heat sinks, power
regulators, and processors may be hot; care should be taken to avoid contact with
these components.
Electro Magnetic Interference: This equipment has not been tested for compliance with emissions limits of FCC
and similar international regulations. This device is not, and may not be, offered for sale or lease, or sold, or
leased until authorization from the United States FCC or its equivalent in other countries has been obtained. Use
of this equipment in a residential location is prohibited. This equipment generates, uses and can radiate radio
frequency energy which may result in harmful interference to radio communications. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
on and off, the user is required to take measures to eliminate the interference or discontinue the use of this
equipment.
Lead Content:
Please recycle this device in a responsible manner. Refer to local environmental
regulations for proper recycling; do not dispose of device in unsorted municipal
waste.
3
User Manual of Ethernet-over-Coax Extender
Preventive and Cautionary Tips
In the use of the product, you must be strict compliance with the electrical safety regulations of the nation
and region.
Please use the power adapter, which is provided by normal company. The standard of the power adapter is
DC12V/1A for DS-1H05-T and DS-1H05-R models, and DC12V/2A for DS-1H05-T/E model.
Please disconnect the power supply before installation or operation.
If the product does not work properly, please contact your dealer or the nearest service center. Never attempt
to disassemble the camera yourself. (We shall not assume any responsibility for problems caused by
unauthorized repair or maintenance.)
If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and
then please contact the service center.
Do not drop the equipment or subject it to physical shock, and do not expose it to high electromagnetism
radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can
cause equipment damage).
Do not place the equipment in extremely hot, cold (the operating temperature shall be -10°C ~ +55°C), dusty
or damp locations, or fire or electrical shock will occur otherwise.
The equipment shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is
forbidden (ignorance can cause fire danger).
Please use a soft and dry cloth when clean inside and outside surfaces of the equipment, not to use alkaline
detergents.
Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases
shall be placed on the apparatus.
When the optical interface is not connecting with the fiber, please apply the protective cap to the interface to
avoid entry of dust.
Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or
equivalent type only. Dispose of used batteries according to the instructions provided by the battery
manufacturer.
4
User Manual of Ethernet-over-Coax Extender
Table of Contents
Chapter 1 Introduction ...................................................................................................................... 6
1.1 Overview .............................................................................................................................. 6
1.2 Features ................................................................................................................................ 6
1.3 System Connections ............................................................................................................. 7
Chapter 2 Operation.......................................................................................................................... 8
2.1 Panel of the Transmitter ....................................................................................................... 8
2.2 Panel of the Receiver ............................................................................................................ 9
2.3 Configuring Coax Transmission Bandwidth .......................................................................... 9
2.4 Installation .......................................................................................................................... 10
Appendix: Specifications ................................................................................................................. 11
5
User Manual of Ethernet-over-Coax Extender

Chapter 1 Introduction

1.1 Overview

Adopting the newest Security Link Over Coax technology, the DS-1H05 Series Ethernet-over-Coax
Extender can be used to transmit the network data and CVBS signal via coaxial cable to the
remote device with low signal loss.

1.2 Features

Support transmission of Ethernet data. Support transmission of 1-channel CVBS signal. Up to 500m transmission distance. Reach the downstream speed of 36Mbps and the upstream speed of 11Mbps. DS-1H05-T/E provides PSE power supply (meets IEEE802.af standard). Easy installation and maintenance. Industrial design ensures high reliability.
6
User Manual of Ethernet-over-Coax Extender
Transmitter
Receiver
Analog Camera
Network Camera
Keyboard
Monitor
Management Center
Switch

1.3 System Connections

Refer to the following figure for the typical system connections of the DS-1H05 Series
Ethernet-over-Coax Extender:
7
User Manual of Ethernet-over-Coax Extender
Serial No.
LED Indicator
Description
Video In
Connect to the CVBS video input signal.
DIP Switch
Set the Ethernet-over-Coax bandwidth.
LAN
Connect the network signal, e.g., video signal from IP
camera, etc.
Serial No.
LED Indicator
Description
Power
Connect to 12 VDC power supply.
Power LED
Indicate red when the device is powered on.
Coax
Connect to DS-1H05-R for Coax transmission.

Chapter 2 Operation

2.1 Panel of the Transmitter

Front Panel:
Description of Front Panel:
Rear Panel:
Description of Rear Panel:
Note: The DS-1H05-T/E supports PSE capability and can provide max. 12W power supply for the
connected camera.
8
User Manual of Ethernet-over-Coax Extender
Serial No.
LED Indicator
Description
Video Out
Send the CVBS video signal to the terminal device.
DIP Switch
Set the Ethernet-over-Coax bandwidth.
LAN
Send the network signal to the terminal device.
Serial No.
LED
Indicator
Description
Power
Connect to 12 VDC power supply.
Power LED
Indicate red when the device is powered on.
Coax
Connect to the Transmitter and receive the modulated
network video signal and CVBS analog video signal.

2.2 Panel of the Receiver

Front Panel:
Description of Front Panel:
Rear Panel:
Description of Rear Panel:

2.3 Configuring Coax Transmission Bandwidth

You can use the DIP switch settings to configure the downstream bandwidth of the DS-1H05-T or
DS-1H05-T/E module and the upstream bandwidth of the DS-1H05-R. Refer to the following table:
9
User Manual of Ethernet-over-Coax Extender
DIP Switch
Transmitter
21 Mbps
25 Mbps
28 Mbps
36 Mbps
Receiver
3 Mbps
4 Mbps
9 Mbps
11 Mbps
Notes:
1. Please reboot the device after you have configured the bandwidth via DIP switch settings.
2. The higher value of bandwidth results in shorter transmission distance.
3. The transmission distance is also different depending on different type of coaxial cable.

2.4 Installation

Prior to Installation
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
Verify that the package contents are correct by checking the items against the packing list.
Please contact with our company immediately in case of damaged or missing items in the
package.
Installing the Device
The device is designed in compact metal shell with antirust and anticorrosive surface coating.
The device provides mounting holes on the side panels and can be directly mounted to the
cabinet, or placed on the desktop or rack.
The cabinet should be with water-proof feature.
10
User Manual of Ethernet-over-Coax Extender
Model
DS-1H05-T
DS-1H05-T/E
DS-1H05-R
Video Input
Interface
RJ-45/BNC
RJ-45/BNC
Coaxial BNC
Video Output
Interface
Coaxial BNC
Coaxial BNC
RJ-45/BNC
PSE — Support
Power
Consumption
5 W
20 W (when PSE power
supply is enabled)
5 W
Power
12 V DC
Working
Humidity
10 % ~ 90 %
Working
Temperature
-10 ~ + 55 Dimensions
80 mm (W) × 96 mm (D) × 27 mm (H)

Appendix: Specifications

11
Loading...