Model OFE/OFG/OEA/OGA-341, 342
This manual should be retained in a convenient location for future reference.
A wiring diagram for this appliance is located on the inside of the right side panel.
Post in a prominent location, instructions to be followed in event user smells gas. This information shall
be obtained by consulting the local gas supplier.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance must be left all around
appliance for sufficient air to the combustion chamber.
The Model OFG/OGA-34X open fryer is equipped with a continuous pilot. But the open fryer can not be
operated without electric power. The unit will automatically return to normal operation when power is
restored.
To avoid a fire, keep appliance area free and clear from combustibles.
Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury or death. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
FM05-033-G
Revised 04-08-08
Model OFE/OFG/OEA/OGA-341, 342
Technical Data for CE Marked Products
Nominal Heat Input: Natural (I2H) = 35,2 KW (120,100 Btu/h)
(Net) Liquid Propane (I3P) = 35,2 KW (120,100 Btu/h)
Nominal Heat Input: Natural (I2H) = 39,1 KW (133,400 Btu/h)
(Gross) Liquid Propane (I3P) = 38,3 KW (130,700 Btu/h)
Supply Pressure: Natural (I2H) = 20 mbar
Liquid Propane (I3P) = 37 mbar
Liquid Propane (I3P) = 50 mbar
Test Point Pressure: Natural (I2H) = 8,7 mbar
Liquid Propane (I3P) = 25 mbar
Injector Size: Natural (I2H) = 3,18 mm
Liquid Propane (I3P) = 1,91 mm
This appliance must be installed in accordance with the manufacturers instructions and the regulations in
force and only used in a suitable ventilated location. Read the instructions fully before installing or
using the appliance.
Datos Tecnicos Para Products CE
Consumo Calorico Nominal: Gas Natural (I2H) = 35,2 KW (120,100 Btu/h)
(Neto) Propano Licuado (I3P) = 35,2 KW (120,100 Btu/h)
Consumo Calorico Nominal: Gas Natural (I
(Bruto) Propano Licuado (I
Presion De Alimentacion: Gas Natural (I
Propano Licuado (I
Propano Licuado (I
Presion En Ez Punto De Prueba: Gas Natural (I2H) = 8,7 mbar
Propano Licuado (I
Diámetro Boquilla: Gas Natural (I
Propano Licuado (I3P) = 1,91 mm
Este equipo debe instalarse únicamente en un recinto adecuadameute ventilado y conforme a las
indicaciones del fabricante y a las normas vigentes. Lea completamente las instrucciones antes de
instalar o usar este equipo.
) = 39,1 KW (133,400 Btu/h)
2H
) = 38,3 KW (130,700 Btu/h)
3P
) = 20 mbar
2H
) = 37 mbar
3P
) = 50 mbar
3P
) = 25 mbar
3P
) = 3,18 mm
2H