Model OFE/OFG-323
Model OFE/OFG-322
Model OFE/OFG-321
Model OFE/OFG-324
Model OEA/OGA-323
Model OEA/OGA-322
Model OEA/OGA-321
Model OEA/OGA-324
Model ODE/ODG-323
Model OFE/OFG-321,322,323,324
This manual should be retained in a convenient location for future reference.
A wiring diagram for this appliance is located on the inside of the right side panel.
Post in a prominent location, instructions to be followed in event user smells gas. This information shall
be obtained by consulting the local gas supplier.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance must be left all around
appliance for sufficient air to the combustion chamber.
The Model OFG/OGA-32X open fryer is equipped with a continuous pilot. But the open fryer can not be
operated without electric power. The unit will automatically return to normal operation when power is
restored.
To avoid a fire, keep appliance area free and clear from combustibles.
Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury or death. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
3-7. Recommended Spare Parts for Distributors ............................................................3-1
Jan. 2009
i
Model OFE/OFG-321,322,323,324
Model OFE/OFG-321,322,323,324
DANGER INDICATES AN IMMINENTLY
HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, WILL RESULT IN DEATH OR
SERIOUS INJURY.
WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
CAUTION used with the safety alert symbol indicates a
potentially hazardous situation which, if not avoided,
could result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, may
result in property damage.
NOTICE is used to highlight especially important
information.
SAFETY ALERT SYMBOL is used with DANGER,
WARNING or CAUTION which indicates a personal
injury type hazard.
SECTION 1. TROUBLESHOOTING
1-1. INTRODUCTIONThis section provides troubleshooting information in the form of an easy to read table.
If a problem occurs during the first operation of a new fryer,
recheck the Installation Section of the Operator’s Manual.
Before troubleshooting, always recheck the Operation Section of
the Operator’s Manual.
1-2. SAFETY Where information is of particular importance or is safety related,
the words DANGER, WARNING, CAUTION, or NOTE are used.
Their usage is described on the next page:
Feb. 2003 1-1
Model OFE/OFG-321,322,323,324
PROBLEM
CAUSE
CORRECTION
With the switch in the POWER
position, fryer is completely
inoperative
● Open circuit
● Check to see if unit is plugged in
● Check the breaker or fuse at
supply box
● Check POWER switch per Power
Switch Section; replace if defective
● Check voltage at wall receptacle
● Check cord and plug
Shortening will not heat but lights
are on
● Faulty contactor (elec. Model)
● Faulty gas control valve
(gas model)
● Faulty temperature probe
● Faulty high limit
● Faulty drain switch
● Check contactor per Heating
Contactors Section
● Check gas control per Gas
Control Valve Assembly Section
● Check temperature probe per
Temperature Probe Replacement
Section; “E-6A or B”
● Check high limit per the
appropriate High Temperature
Limit Control Section; “E-10”
● Check drain switch per Drain
Microswitch Section; “E-15”
1-3. TROUBLESHOOTING To isolate a malfunction, proceed as follows:
1. Clearly define the problem, or symptom and when it
occurs.
2. Locate the problem in the troubleshooting table.
3. Review all possible causes, then one at a time, work through the list of corrections until the problem is solved.
If maintenance procedures are not followed correctly,
injuries and/or property damage could result.
1-2 Dec. 2016
PROBLEM
CAUSE
CORRECTION
Heating of shortening too slow
● Low or improper voltage (elec.
Model)
● Weak or burnt out elements (elec.
Unit)
● Wire(s) loose
● Burnt or charred wire connection
● Faulty contactor
● Supply line too small-low gas
volume (gas unit)
● Improper ventilation
● Use a meter and check that
receptacle voltage against the data
plate
● Check heating elements per
Heating Elements Section
● Tighten
● Replace wire and clean
connectors
● Check contactor per Heating
Contactors Section
● Increase supply line size; refer to
Installation Section of Operator’s
Manual
● Refer to Installation Section of
Operator’s Manual
Shortening overheating
● Temperature probe needs
calibration
● Mercury contactor stuck closed
● Bad control board
● Calibrate temperature probe if
10 off; if more than 10 off,
replace temperature probe
● Check mercury contactor for not
opening; replace if necessary (elec.
Unit)
● Replace control board if heat
indicator stays on past ready
temperature
Foaming or boiling over of
shortening
● Water in shortening
● Improper or bad shortening
● Improper filtering
● Improper rinsing after cleaning
fryer
● At end of cook cycle, drain
shortening and clean
● Use recommended shortening
● Refer to the Filtering the
Shortening Section in Operator’s
Manual
● Clean and rinse the frypot; then
dry thoroughly
1-3. TROUBLESHOOTING
(Continued)
Model OFE/OFG-321,322,323,324
Model OFE/OFG-321,322,323,324
PROBLEM
CAUSE
CORRECTION
Shortening will not drain from
frypot
● Drain valve clogged with crumbs
● Drain valve will not open by
turning handle
● Open valve, force cleaning brush
through drain
● Replace cotter pins in valve
coupling
Filter motor runs but pumps
shortening slowly
● Pump clogged
● Filter line connection loose
● Solidified shortening in lines
● Remove pump cover and clean
● Tighten all filter line connections
● Clear all filter lines of solidified
shortening
Filter switch on but motor does not
run
● Defective switch
● defective motor
● Motor thermal protector tripped
● Check/replace switch per Filter
Switch Section
● Check/replace motor
● Reset thermal switch on filter
motor
Motor hums but will not pump
● Clogged lines or pump
● Remove and clean pump and
lines
● Replace pump seal, rotor and
rollers
Dec. 2016 1-3
1-3. TROUBLESHOOTING
(Continued)
Model OFE/OFG-321,322,323,324
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-4”
Control board overheating
Turn switch to OFF position, then turn switch
back to ON; if display shows “E-4”, the
control board is getting too hot; check the
louvers on each side of the unit for
obstruction
“E-5”
Shortening overheating
Turn the switch to OFF position, then turn
switch back to ON; if display shows “E-5”,
the heating circuits and temperature probe
should be checked
“E-6A”
Temperature probe open
Turn switch to OFF position, then turn switch
back to ON; if display shows “E-6A” the
temperature probe should be checked
“E-6B”
Temperature probe shorted
Turn switch to OFF position, then turn switch
back to ON; if display shows “E-6B” the
temperature probe should be checked to
replace, per Temperature Probe Replacement
Section
“E-10”
High limit
Reset the high limit by manually pushing up
on the red reset button; if high limit does not
reset, high limit must be replaced per High
Limit Temperature Control Section
“E-15”
Drain switch failure
Close drain, using the drain valve handle; if
display still shows “E-15”, check the drain
microswitch per Drain Microswitch Section
“E-41”
“E-46”
Programming failure
Turn switch to OFF, then back to ON. If
display shows any of the error codes, try to
reinitialize the control (Special Program
Mode Section of Operator’s Manual). If error
code persists, replace the control panel per
Complete Control Panel Replacement Section
“E-20A”
Vacuum switch failure (stuck closed)
Press the timer button to try the ignition
process again, and if “E-20A” persists, check
the vacuum switch per Vacuum Switch
Section
1-4 Dec. 2016
1-4. ERROR CODESIn the event of a control system failure, the digital display shows an error message. These messages are coded: “E-4”, “E-5”, “E 6A”, “E-6B”, “E-10”, “E-15”, “E-20”, “E-31”, “E-41”, “E-46”, and “E-92”. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.
Model OFE/OFG-321,322,323,324
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-20B”
Draft fan or vacuum switch failure
(stuck open)
Press the timer button to try the ignition
process again, and if “E-20B” persists, check
the vacuum switch per Vacuum Switch
Section or the blower motor per Blower
Motor Assembly Section
“E-20C”
Ignition modules not responding
Press the timer button to try the ignition
process again; if “E-20C” persists, check the
ignition module per Ignitor Module Section or
the spark ignitor per Pilot/Ignitor Assembly
Section, or the I/O board per I/O Power
Supply Boards Assembly Section
“E-20D”
Pilots not lit or no flame sense
Press the timer button to try the ignition
process again; if “E-20D” persists, check the
ignition module per Ignitor Module Section,
or the I/O board per I/O Power Supply Boards
Assembly Section, or the flame sense per
Flame Sensor Section
“E-31”
Fan switch jumper wire missing
Check for jumper wire on 12-pin connector
and add if missing
“E-47”
Analog converter chip or 12 volt
supply failure
Turn switch to OFF, then back to ON; if
“E-47” persist, replace the I/O board, or the
PC board; if speaker tones are quiet, probably
I/O board failure
“E-48”
Input system error
Replace PC board
“E-70”
Faulty POWER switch or switch
wiring; faulty I/O board
Check POWER switch, along with its wiring;
replace input/output board if necessary
“E-92”
24 VAC fuse on I/O open
Check for shorted component in 24 volt
circuit;
(i.e., high limit, drain switch, vacuum switch)
Dec. 2016 1-5
1-4. ERROR CODES
(Continued)
1-6 Dec. 2016
Model OFE/OFG-321,322,323,324
SECTION 2. MAINTENANCE
2-1. INTRODUCTIONThis section provides procedures for the checkout and replacement of the various parts used within the fryer. Before replacing any
parts, refer to the Troubleshooting Section. It will aid you in
determining the cause of the malfunction.
2-2. MAINTENANCE HINTS 1. You may need to use a multimeter to check the electric
components.
2. When the manual refers to the circuit being closed, the
multimeter should read zero unless otherwise noted.
3. When the manual refers to the circuit being open, the
multimeter will read infinity.
2-3 HIGH TEMPERATURE
LIMIT CONTROL The high temperature limit control is a safety, manual reset control
(Gas Units) that senses the temperature of the shortening. If the shortening
temperature exceeds 425F (218C), this switch will open
and shut off heat to the frypot. When the temperature of the
shortening drops to a safe operation limit, the control must be
manually reset by pressing the red reset button. The red reset
button is located under the control panel, in the front of the fryer.
This will allow heat to be supplied to the frypot once again.
CheckoutBefore replacing a high temperature limit control, check to see
that its circuit is closed.
The shortening temperature must be below 380F
(193C) to accurately perform this check.
Checkout:
1. Remove electrical power supplied to fryer.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel.
Feb. 2003
2-1
Model OFE/OFG-321,322,323,324
2-3 HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
3. Remove the two nuts securing the high limit bracket to the unit
and pull the bracket from the unit.
4. Remove the two screws securing the high limit to the bracket,
and remove the high limit from the bracket.
5. Remove the two electrical wires from the high temperature
limit control.
6. Manually reset the control, then check for continuity between
the two terminals after resetting the control. If the circuit is
open, replace the control, then continue with this procedure.
(If the circuit is closed, the high limit is not defective. Reconnect the two electrical wires.)
Replacement:
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. If the tube is broken or cracked, the control will open, shutting
off electrical power to the heat circuit. The control cannot be
reset, and it will continuously click when pushed.
2. Drain the shortening from the frypot and discard. A substance
in the tube could contaminate the shortening.
3. Remove the control panel.
4. Loosen small inside screw nut on capillary tube.
2-2
Feb. 2003
2-3 HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
Model OFE/OFG-321,322,323,324
5. Remove the bracket from the heat tube covering the high limit
bulb.
6. Straighten the capillary tube behind the pot wall.
7. Pull the high limit bulb through the retainers on the heat tube.
8. Remove the larger outside nut that threads into the pot wall.
9. Remove the defective high limit from the control panel area.
10. Insert new high limit into bracket and replace wires.
11. Uncoil capillary line, starting at capillary tube, and insert
through frypot wall.
To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must never be in such a position where
it could accidentally touch the electrical power terminals.
12. Insert capillary line through brackets on heat tube, and then
pull back through pot wall until capillary bulb is secure in
brackets.
13. Pull excess capillary line from pot and tighten nut into frypot
wall.
14. With excess capillary line pulled out, tighten smaller nut.
15. Replace bracket on heat tube covering the high limit bulb.
16. Replace front panel.
17. Refill frypot with shortening.
Feb. 2003 2-3
Model OFE/OFG-321,322,323,324
2-4. COMPLETE CONTROL
PANEL REPLACEMENT Should the control board become inoperative, follow these
instructions for replacing the board.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the four screws securing the control panel and lift out.
3. Unplug the wire connectors going to the control board.
4. Install new control panel in reverse order.
When plugging connectors onto new control panel, be sure
the connectors are inserted onto all of the pins, and that the
connectors are not forced onto the pins backwards. If not
connected properly, damage to the board could result.
2-5. POWER SWITCH 1. Remove electrical power supplied to fryer.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove control panel.
2. Label and remove the wires from the switch. With test
instrument, check across the terminals of the switch
with the switch in the ON position, then in the OFF
position. With the switch in the ON position, the circuit
should be closed. With the switch in the OFF position,
the circuit should be open. If the switch checks
defective, replace by continuing with this procedure.
2-4
Feb. 2003
Model OFE/OFG-321,322,323,324
2-5. POWER SWITCH
(Continued) 4. With control panel removed, and the wires off the switch, push
in on tabs on the switch to remove from panel.
5. Replace with new switch, and reconnect wires to switch.
6. Replace the control panel.
2-6. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature to
REPLACEMENTthe control board. If it becomes disabled, “E-6B” will show in the
display. Also, if the shortening temperature is out of calibration by
more than 10°F or C°, the temperature probe should be replaced.
An Ohm check can be performed also. See chart on page 2-7.
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit Electricbreaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the control panel.
Gas
4. Using a 1/2" wrench, remove the nut on the compression
fitting.
5. Remove the temperature probe from the frypot.
6. Follow the appropriate instructions, on the following page,
depending upon the type of fryer, gas or electric.
June 2006
2-5
2-6. TEMPERATURE PROBE REPLACEMENT
(Continued) ELECTRIC
Model OFE/OFG-321,322,323,324
GAS
2-6 June 2006
Model OFE/OFG-321,322,323,324
2-6. TEMPERATURE PROBE 7. Tighten the compression nut hand tight and then a half turn
REPLACEMENT with wrench.
(Continued)
Excess force will damage temperature probe.
8. Connect new temperature probe to PC board and replace control panel.
9. Replace shortening.
10. Turn power on and check out fryer.
June 2006
2-7
Model OFE/OFG-321,322,323,324
2-7. FLAME SENSOR The flame sensor recognizes the pilot flame and allows gas to
(Gas Units)continue to the pilot. The flame sensor must send a minimum of
two (2) micro amps to the ignition module. The pilot flame should
be split in two by the flame sensor, causing the flame sensor to be
bright red in color.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle..
2. To access flame sensor, open the filter doors in the front of the
unit. Follow the small gauge yellow wire running to the sensor
behind the pilot assembly.
3. Disconnect the flame sense wire from the flame sensor.
4. Using a pair of needle nosed pliers, pull the flame sensor out
of the pilot assembly bracket.
5. Insert new flame sensor and reconnect flame sensor wire.
6. Turn power on and check fryer.
2-8 Feb. 2003
Model OFE/OFG-321,322,323,324
2-8. PILOT / IGNITOR The Henny Penny open fryer (gas) has electronic spark ignition
ASSEMBLYthat lights a standing pilot. The gap between the spark electrode
and the pilot hood should be set at 1/8 of an inch.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
TO AVOID PERSONAL INJURY OR PROPERTY
DAMAGE, BEFORE STARTING THIS
PROCEDURE, MOVE THE MAIN POWER SWITCH
TO THE OFF POSITION. DISCONNECT THE MAIN
CIRCUIT BREAKERS AT THE CIRCUIT BREAKER
BOX OR UNPLUG SERVICE CORD FROM WALL
RECEPTACLE. TURN OFF THE MAIN GAS
SUPPLY TO THE FRYER AND DISCONNECT AND
CAP THE MAIN SUPPLY LINE TO FRYER, OR
POSSIBLE EXPLOSION COULD RESULT.
2. Remove the control panel as discussed in Complete Control
Panel Replacement Section.
3. Disconnect the pilot gas line fitting at the pilot assembly with
a ½ inch wrench.
4. With a Phillips head screwdriver, remove the two screws
securing the pilot assembly to the mounting bracket.
5. Remove the flame sensor wire from the flame sensor.
6. Follow the wire from the spark ignitor back to the module, and
remove wire from module.
7. After removing assembly from unit, pull the flame sensor out
of the bracket as discussed in section 6-7. Insert flame sensor
into new pilot/ignitor assembly.
8. Reinstall the new pilot/ignitor assembly in reverse order. Be
extremely careful not to cross thread the pilot gas line fitting.
Feb. 2003 2-9
Model OFE/OFG-321,322,323,324
2-9. IGNITOR MODULE During normal operation, the ignition modules send 24 volts to the
ignitors and gas control valve. If a module does not sense a pilot
flame, the module starts the ignition process again. But, if a pilot
light goes out for longer that 10 seconds, or it goes out 3 times within
10 seconds, the module keeps the 24 volts from reaching the gas
control valve. The burners shut down.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control Panel
Replacement Section.
3. Label and remove the wires at module.
4. Using a 3/8 inch nut driver, remove the keps nuts securing the
module to the shroud.
5. Install new module in reverse order.
2-10. TRANSFORMERThe transformer reduces voltage down to accommodate those
components with low voltage.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control Panel
Replacement Section.
3. Squeeze on the wire connector at the I/O board assembly to
disconnect the wires from the transformer.
4. Using a Phillips head screwdriver, remove the two screws
securing the transformer to the shroud.
5. Install the new transformer in reverse order.
2-10 Feb. 2003
Model OFE/OFG-321,322,323,324
2-11. I/O POWER SUPPLY
BOARD ASSEMBLY The input/output power supply board assembly distributes
voltage to the various components in the fryer. The board also
receives information from components in the fryer.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control
Panel Replacement Section.
3. Disconnect the wire assemblies from the board.
4. Using a nut driver or wrench, remove the four keps nuts
securing the board to the shroud.
5. Install the new I/O board assembly in reverse order.
2-12. VACUUM SWITCH The vacuum switch senses the airflow from the induction blower.
If the airflow is reduced below a set amount, the switch will open
and the I/O board will cut power to the gas control valve, which
will shut the pilot flame off.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control
Panel Replacement Section.
3. Remove the air hose from the vacuum switch.
4. Label and remove wires from vacuum switch.
Feb. 2003 2-11
Model OFE/OFG-321,322,323,324
2-12. VACUUM SWITCH
(Continued) 5. Using a Phillips head screwdriver, remove the screws securing
the vacuum switch to the shroud.
6. Install the new vacuum switch in reverse order.
To avoid property damage, do not tamper with, or disas semble this component. It is set and sealed from the
factory and is not to be adjusted.
2-13. SPEAKER ASSEMBLY The speaker assembly emits audible signals to let the operator
(Gas Units)know when cooking and hold times are finished.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control
Panel Replacement Section.
3. Using a Phillips head screwdriver, remove the four screws
securing the speaker to the shroud.
4. Install new speaker in reverse order. When plugging connector
into control board, be sure to align pins into connector
correctly.
2-12 Feb. 2003
Model OFE/OFG-321,322,323,324
2-14. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch circuit
should open, cutting off the pilot flame. This will prevent the fryer
from heating while shortening is being drained from the frypot.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. The following check should be made to determine if the drain
microswitch is defective.
a. Remove the two screws securing the microswitch to the
drain rod valve bracket.
b. Remove wires from the switch.
c. Check for continuity across the two outside terminals of the
drain switch. If the circuit is open, the drain switch is
defective. The circuit should only be opened by pressing on
the actuator of the drain switch.
3. Replace switch in reverse order.
2-15. FILTER SWITCH
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Feb. 2003 2-13
Model OFE/OFG-321,322,323,324
2-15. FILTER SWITCH
(Continued) 2. Remove the control panel above the switch.
3. Label and remove the wires from the switch. With test
instrument, check across the terminals of the switch with the
switch in the ON position, and then in the OFF position. With
the switch in the ON position, the circuit should be closed.
With the switch in the OFF position, the circuit should be open.
If the switch checks defective, replace it by continuing with this
procedure.
4. With wires removed from the switch, push in on tabs on the
switch and remove switch from the panel.
5. Push new switch into panel and reconnect wires.
2-16. GAS CONTROL VALVE
ASSEMBLY The gas control valve assembly controls the flow of gas to the pilot
and the main burner. The valve has two 24 volt coils, which are
regulated by terminals P and M on the valve. The C terminal is the
common terminal. For gas flow to the pilot, 24 VAC must be
present between the P and C terminals. For gas flow to the main
burner, 24 VAC must be present between the M and C terminals.
TO AVOID PERSONAL INJURY OR PROPERTY
DAMAGE, BEFORE STARTING THIS
PROCEDURE, MOVE THE MAIN POWER SWITCH
TO THE OFF POSITION. DISCONNECT THE MAIN
CIRCUIT BREAKERS AT THE CIRCUIT BREAKER
BOX OR UNPLUG SERVICE CORD FROM WALL
RECEPTACLE. TURN OFF THE MAIN GAS
SUPPLY TO THE FRYER AND DISCONNECT AND
CAP THE MAIN SUPPLY LINE TO FRYER, OR
POSSIBLE EXPLOSION COULD RESULT.
1. Remove control panel assembly.
2. Remove wires from gas control valve.
2-14 Feb. 2003
Model OFE/OFG-321,322,323,324
2-16. GAS CONTROL VALVE
ASSEMBLY
(Continued)
3. Using a 7/16 inch wrench, remove the pilot line from the gas
control valve.
4. Using a 1 inch wrench, loosen the nut securing the main gas
inlet line to the gas control valve.
5. Using 5/8 inch wrench, remove the two burner gas line fittings
at the black tee fitting, located behind the control panel area.
6. Using a Phillips head screwdriver, remove the three screws
securing the gas control valve bracket to the frame of the fryer
behind the control panel area.
Feb. 2003 2-15
Model OFE/OFG-321,322,323,324
2-16. GAS CONTROL VALVE
ASSEMBLY
(Continued)
7. With the bracket dropped down, remove the two screws behind
the bracket securing the gas control valve to the bracket.
8. Install the new gas control valve in reverse order.
2-17. BLOWER MOTOR
ASSEMBLY The blower motor assembly induces the draft for the burners. If the
blower motor fails, the air switch will fail to close, causing an
“E-20B” error code in the display.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove screws securing the two rear covers to the unit.
3. Remove the wire cover from the blower motor housing.
2-16 Feb.2003
Model OFE/OFG-321,322,323,324
2-17. BLOWER MOTOR
ASSEMBLY
(Continued)
4. Remove wire nuts connecting blower motor wires to wires in
conduit.
5. Loosen conduit from blower motor.
6. Remove screws connecting flue to bracket in upper frame.
7. Remove screws connecting flue to blower.
Feb. 2003 2-17
Model OFE/OFG-321,322,323,324
2-17. BLOWER MOTOR
ASSEMBLY
(Continued)
8. Using 3/8 inch nut driver, remove nuts securing blower to the
unit. Pull blower from unit.
9. Install new blower in reverse order.
2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
Heating elements are available for 208 and 230 volts. Check
data plate to determine correct voltage.
Checkout:
If the shortenings temperature recovery is very slow or at a slower
rate than required, this may indicate defective heating element(s).
An ohmmeter will quickly indicate if the elements are shorted or
open.
1. Remove electrical power supplied to the frypot to be worked on.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle, to the frypot
to be worked on. Be aware the other controls will have
power.
2. Remove control panel.
2-18 Feb. 2003
Model OFE/OFG-321,322,323,324
2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
(Continued) 3. Perform an ohm check on one element at a time, with wires
disconnected from element. If the resistance is not within
tolerance, replace the element.
Voltage Wattage Resistance Ohms (cold)208 4800 9
230 4800 11
Replacement:
Refer to figure 2-2.
1. Drain the shortening from the frypot.
2. Remove the high limit bulb holder from the heating element
inside the frypot.
3. Remove the heating element wires from the terminals by
removing the nuts and washers. Label each so it can be
replaced on the new element in the same position.
4. Remove the bolts from the five element spreaders. The
element spreaders will now pull off the elements.
5. Remove the brass nuts and washers which secure the ends of
the elements through the frypot wall.
6. Remove the heating elements from the frypot as a group by
lifting the far end and sliding them up and out toward the
rear of the frypot.
Always install new rubber O-rings when installing heater
elements.
7. Install new heating elements with the new O-rings, terminal
end first at approximately a 45 angle, slipping the terminals
through the front wall of the frypot.
8. Replace the brass nuts and washers on the element terminals.
Tighten the brass nuts to 30 foot lbs. of torque.
Feb. 2003
2-19
Model OFE/OFG-321,322,323,324
2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
(Continued) 9. Evenly space the element spreaders on the sides of the
elements and reinstall bolts. Place the fifth spreader in the
front of the elements as to protect the temperature probe.
(Fig.6-1
10. Replace the high limit bulb holder on the top element, and
position the bulb between the top and second element
midway from side to side, and tighten screw that holds the
bulb in place.
11. Reconnect the wires to the appropriate terminal as labeled
when they were removed.
Temperature Spreader
Probe
Fig. 2-1 12. Replace the front control panel.
13. Connect the power cord to the wall receptacle or close wall
circuit breaker.
Heating elements should never be energized without
shortening in the frypot, or damage to the elements could
result.
14. Replace the shortening in the frypot.