Henny Penny OE 301 User Manual

Page 1
enny
This section provides the installation instructions for the Henny Penny Fry Station.
Installation of the unit should be performed only by a qualified service technician.
Do not puncture the unit with any objects such as drills or screws as component damage or electrical shock could result.
The Henny Penny Fry Station has been tested, inspected, and expertly packed to ensure arrival at its destination in the best possible condition. The unit is bolted to a wooden skid and then packed inside a heavy cardboard carton with sufficient padding to withstand normal shipping treatment.
Any shipping damage should be noted in the presence of the delivery agent and signed prior to his or her departure.
1. Carefully cut bands from cardboard carton.
2. Lift carton from fryer.
This manual should be retained in a convenient location for future reference.
Wiring diagram for this appliance is located on the inside access door below the control panel. Post in a prominent location, instructions to be followed in event user smells gas. This information shall be obtained by consulting the local gas supplier.
Page 2
The proper location of the Fry Station is very important for operation, speed, and convenience. The location of the fiy station should allow clearances for servicing and proper operation. Choose a location which will provide easy loading and unloading without interfering with the final assembly of food orders. Operators have found that frying from raw to finish, and holding the product in warmers provides fast con tinuous service. Keep in mind the best efficiency will be obtained by a straight line operation, i.e. raw in one side and finished out the other side. Order assembly can be moved
away with only a slight loss of efficiency. The fryer should be installed in such a way as to prevent
tipping or movement causing splashing of hot liquid shortening.
This may be accomplished by the location the fiy station is in, or
by restraining ties.
The gas Model OG-300 Series Fry Station is designed for installation on combustible floors and adjacent to combustible walls. Fry Station must be installed with a minimum clearance from all combustible, and noncombustible materials, 4 inches from side and 4 inches from the back.
For proper operation, the fry station should be level from side to side and front to back. Using a level place on the flat areas around the frypot collar, on the middle well, adjust
the casters until the unit is level.
adequate exhaust hood or vent is essential to permit efficient removal of the steam exhaust and frying odors. Special precaution must be taken in designing an
exhaust canopy to avoid interference with the operation of the
1 fry station. We recommend you consult a local ventilation or
heating company to help in designing an adequate system.
Ventilation must conform to local, state, and national codes. Consult your local fire department or building authorities.
Page 3
When installing the gas fry station do not attach an exten­sion to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft.
The gas fry station is factory available for either natural or propane gas. Check the data plate inside the front door of the cabinet to determine the proper gas supply requirements.
TE
The OG-301 can be operated at altitudes of up to 4000 feet above sea level with no changes to the unit. For operation
above 4000 feet, please contact Henny Penny Corporation for changes to the unit.
Do not attempt to use any gas other than that specified on the data plate. Incorrect gas supply could result in a fire or explosion.
Please refer to the illustration on the following page for the recommended hookup of the fry station to the main gas line
supply.
To avoid possible serious personal injury:
* Installation must conform with American National Standard
2223. l-Latest Edition National Fuel Gas Code and the local municipal building codes. In Canada, installation must be in accordance with Standard CAN/CGA B 1 49.1 & .2, Installation Codes - Gas Burning Appliances and local codes.
0 The fry station and its individual shutoff valve must be
disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of
l/2 PSIG (3.45 KPA).
* The fry station must be isolated from the gas supply piping
system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than l/2 PSIG (3.45 KPA).
Page 4
odel
T
INIMU~I PULL of equip­ment away from wall permissible for accessi­bility to Quick Disconnect Device.
Couplings and hose should be installed in the same plane as shown at left. DO NOT OFFSET COUPLINGS-this causes torsional twisting and undue strain causing
premature failure.
AVOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Max­imum pull will kink ends, even if installed properly, and reduce Connector life.)
~
QUICK DISCON. NECT DEVICE
while extended
MAXIMUM PULL NOT ADVISED WHILE CONNECTED
Please refer to the illustration below when installing cable restraint on all moveable gas fryers.
at
l-bolt is to be secured to the building using acceptable building construc­tion practices.
This is the correct way to install metal hose for ver­tical traverse. Note the single, natural loop.
Allowing a sharp bend, as shown at right, strains and twists the metal hose to a point of early failure at the coupling.
Maintain the minimum or larger bending diameter between the couplings longest life.
Closing in the diameter at the couplings, as shown at right, creates double bends causing work fatigue failure of the
fittings.
In all installations where “self-draining” is not necessary, connect metal hose in a vertical loop.
~0 NOT CONNECT METAL HOSE HORI-
ZONTALLY . . . unless
“self-draining” is neces-
sary, then us% support on
lower plane as shown at
left.
for
c
CT1
Secure l-bolt to a building stud. DO NOT attach to dry wall only. Also,
locate the l-bolt at the same height as the gas service. Preferred installation is approximately six inches to either side of service. Cable restraint must
be at least six inches shorter than flexible gas line.
Utilize elbows when necessary to avoid sharp kinks or excessive ben­ding. For ease of movement, install with a “lazy” loop. Gas appliance
must be disconnected prior to max-
imum movement. (Minimum move-
ment is permissible for hose
disconnection).
Page 5
A standard one inch, black steel pipe and malleable fittings should be used for gas service connections. Do not use cast iron fittings. Although one inch size pipe is‘reconunended, piping should be of adequate size and installed to provide a supply of gas sufficient to meet the maximum demand without undue loss of pressure between the meter and the fry station. The pressure loss in the piping system should not exceed 0.3 inch water column.
“revisions should be made for moving the fry station for leaning and servicing. This may be accomplished by:
Installing a manual gas shut off valve and a disconnect union, or
Installing a heavy duty design A.G.A. certified connector. In order to be able to service this appliance, which is provided with casters, a connector complying with ANSI 221.69 or CAN/CGA 6.16 and a
quick-disconnect device complying with ANSI 22 1.4 1 or CAN l-6.9 must be installed. It must also be installed with restraining means to guard against
transmission of strain to the connector as specified in
the appliance manufacturer’s instruction. Refer to the cable restraint instructions (illustration 2-6)
on how and where to attach the restraining devices to the wall and fryer.
Prior to turning the gas supply on, be sure the gas dial
cock on fry station gas valve is in the OFF position. After the piping and fittings have been installed, check for gas leaks. A simple checking method is to turn on
the gas and brush all connections with a soap solution.
If bubbles occur, it indicates escaping gas. In this event, the piping connection must be redone.
Never use a lighted.match or open flame to test for gas
leaks. Escaping gas could cause an explosion resulting in severe personal injury.
Page 6
The following steps provide the pilot PROCEDURE lighting procedure:
1. Open doors and open gas shut-off valve. (see illustrations)
2. The gas cock dial has a dual function: a. Complete control of gas to the pilot and main burner.
b. When in the pilot position, it is the reset mechanism
for the automatic pilot.
3. Partially depress and turn the control gas cock dial to the OFF position.
4. Wait a sufficient length of time to allow any gas which may have accumulated in the burner compartment to escape (at least 5 minutes).
5. Turn the main power switch to the OFF position.
6. Turn the gas cock dial to the PILOT position.
7. Depress and hold gas cock dial while lighting the pilot. Allow the pilot to burn approximately 30 seconds before releasing the gas cock dial. The pilot should remain lighted.
If the pilot does not remain lighted, repeat steps 2 and 3, allowing a longer period of time before releasing the gas cock dial.
8. Turn the gas cock dial to the ON position.
9. Turn the power switch to the “ON” position.
10. Listen for the gas burner ignition. It will be an audible
sound due to the gas igniting at the gas jets within the burner.
Do not leave the power switch on for more than 10 seconds; damage to the frypot may result.
11. The frypots should be cleaned per the instructions in section 3.
12. The frypots must be filled to the proper level with shortening. Refer to section 3-4.
13. The fry station is now ready for operation.
Page 7
Depress lightly and turn manual lever on gas valve to
the OFF position.
The gas pressure regulator on the automatic gas valve is factory set as follows:
@ Natural: 3.5 inches water column. * Propane 10 0 inches water column.
e
120 V, 50/60 Hz., 12 A, 1 PH
0 230 V, 50/60 HZ., 6 A, 1 PH
The gas fry station requires a 3 wire grounded service.
W
I
DO NOT DISCONNECT THE GROUND PLUG. This fry station MUST be adequately and safely grounded or electrical shock could result. Refer to local electrical codes for correct grounding procedures or in absence of local codes, with the National Electrical Code, ANSO/NFPA No. 70 Latest Edition. Canadian models
are supplied with a terminal box, suitable for conduit connection. In Canada, all electrical connections are to be made in accordance with CSA C22 1, Canadian
Electrical Code Part 1, and/or local codes.
Servicing of the filter pump is done at the rear of the
unit. If service is required, disconnect the fry station
from the electrical power source. The fry station will
have to be pulled out from the wall.to gain access to
rear.
ING
c
Page 8
The OE-301/302/303 is available from the factory wired 208, or 220/240
volts, 50 or 60 hertz source.
Refer to the table below for supply wiring and fusing.
Volts Phase
208 3
208 3 220/240 3 2201240 3
400 3
400 3
KW
Amps
11.25 31
13.50 38
11.25 30132
13.50 33135
11.25 16
13.50 20
This fry station must be adequately and safely grounded. Refer to local electrical codes for correct grounding procedures. If fry station is not adequately grounded, electrical shock could result.
A separate disconnect switch with proper capacity fuses or breakers must be installed at a convenient location between the fry station and the power source.
I
Each Hentry Penny Fry Station was completely checked and tested prior to shipment. However, it is good practice to check the unit a again after installation.