Model MPC-1L, MPC-22, MPC-554
SECTION 2. INSTALLATION
2-1. INTRODUCTION
2-2. UNPACKING
This section provides the installation instructions for the Henny
Penny Multipurpose Holding Cabinet.
Installation of this unit should be performed only by a qualifi ed service technician.
Do not puncture the skin of the unit with drills or screws
as component damage or electrical shock could result.
The Henny Penny Multipurpose Holding Cabinet has been tested,
inspected, and expertly packed to ensure arrival at its destination
in the best possible condition. The cabinet rests on cardboard pads
that sit on a wooden skid. The unit is then packed inside a heavy
cardboard carton with suffi cient padding to withstand normal
shipping treatment.
Any shipping damages should be noted in the presence of the
delivery agent and signed prior to his or her departure.
To remove the Henny Penny Multipurpose Holding Cabinet
from the carton, you should:
1. Carefully cut banding straps.
2. Lift the carton off the unit.
3. Lift the unit off the cardboard padding and skid.
Take care when moving the MPC-554 to prevent personal
injury. The unit weighs 112 lbs. (50.8kg).
4. Peel off any protective covering from the exterior of the cabinet.
5. The unit is now ready for location and set up.
611 2-1
Model MPC-1L, MPC-22, MPC-554
2-3. LOCATION
2-4. ELECTRICAL
CONNECTION
The unit should be placed on a supportive structure or shelf so the
entire bottom of the unit is evenly supported, and also, where the
pans can be removed without interruption and easy loading and
unloading of product. For proper operation, the cabinet must be
level.
Access to the controls are on the side of the unit. Do not block
the controls where they are not visible or which prevents easy
access by a service technician. These controls do not need to be
accessed for normal operation.
The data plate, located on the rear of the unit on the MPC1L & 22
and on the side of the MPC-554, specifi es the correct electrical
supply. The unit requires a grounded receptacle with a separate
electrical line protected by a fuse or circuit breaker of the proper
rating. Electrical code may also require GFCI protection.
To avoid electrical shock, the cabinet must be adequately
and safely grounded (earthed) according to local electrical
codes.
The units are supplied with a 9 foot (274.3 cm) power cord.
Refer to the table below for electrical ratings:
Product Number Volts Watts Amps
MPC-554 120 1160 9.6
MPC-1L 120 110 .92
MPC-22 120 400 3.3
2-2 611