2-1. INTRODUCTION
Model HHC-980/983
SECTION 2. INSTALLATION
Installation of this unit should be performed only by a
qualified service technician.
Do not puncture the the skin of the unit with drills or
screws as component damage or electrical shock could
result.
2-2. UNPACKING
The Henny Penny humidified holding cabinet has been tested,
inspected, and expertly packed to ensure arrival at its destination in the best possible condition.
Any shipping damage should be noted in the presence
of the delivery agent and signed prior to his or her
departure.
T o remove the Henny Penny cabinet from carton:
1. Carefully cut banding straps.
2. Lift carton off the unit.
3. Lift the unit off the cardboard padding and skid.
T ake care when moving the fryer to prevent personal
injury. Full-size cabinets weigh about
300 lbs. (136 kg).
203 2-1
Model HHC-980/983
2-2. UNPACKING
(Continued)
2-3. LOCA TION
2-4. ELECTRICAL
CONNECTION
4. Open doors and remove packing from behind racks and
the water pan in the bottom of the unit.
5. Peel off any protective covering from the exterior of the
cabinet.
6. The cabinet is now ready for location and use.
Place the humidified holding cabinet in an area that allows
the doors to be opened without interference of loading and
unloading product. Also, keep the unit level for proper
operation.
No minimum clearances are required for the rear and sides
of the cabinet.
T o avoid electrical shock, the cabinet must be adequately
and safely grounded (earthed) according to local electrical
codes, and this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded
(unearthed) conductors. The main power switch on this
appliance does
not disconnect all line conductors.
(FOR EQUIPMENT WITH CE MARK ONL Y!)
T o prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces in
close proximity to this appliance with an equipotential
bonding conductor . This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
If the electrical supply to the unit is a cord and plug, then the
electrical receptacle, for the plug, must be easily accessible.
Refer to the table below for the electrical ratings for the
HHC-980 and 983.
Model Volts Phase Amps Watts
HHC-980 208 1 13.8 2880
240 1 12.0 2876
220-240-CE 1 11.6 2792
HHC-983 120 1 17.3 2080
220-240-CE 1 8.3 1992
2-2 1004