Model HHC-90X/Model HC-5/15
SECTION 2. INSTALLATION
2-1. INTRODUCTION
2-2. UNPACKING
This section provides the installation instructions for the Henny
Penny Heated Holding Cabinet.
Installation of this unit should be performed only by a qualif ed service technician.
Do not puncture the skin of the unit with drills or screws
as component damage or electrical shock could result.
The Henny Penny Heated Holding Cabinet has been tested, inspected, and expertly packed to ensure arrival at its destination in
the best possible condition. The cabinet rests on cardboard pads
that sit on a wooden skid. The racks inside the cabinet are secured
with cardboard packing. The unit is then packed inside a heavy
cardboard carton with suff cient padding to withstand normal
shipping treatment.
Any shipping damages should be noted in the presence of the
delivery agent and signed prior to his or her departure.
To remove the Henny Penny Heated Holding Cabinet from the
carton, you should:
1. Carefully cut banding straps.
2. Lift the carton off the unit.
3. Lift the unit off the cardboard padding and skid.
Take care when moving the unit to prevent personal
injury. The unit can weigh up to 500 lbs. (227 kg).
4. Open doors and remove packing from behind racks.
5. Peel off any protective covering from exterior of the cabinet.
6. The unit is now ready for location and set up.
2-1 203
Model HHC-90X/Model HC-5/15
2-3. LOCATION
2-4. ELECTRICAL
CONNECTION
The unit should be placed in an area where the doors can be
opened without interruption and loading and unloading of product
is easy. For proper operation, the cabinet must be level.
To avoid damage to the unit, do not set anything on top of the
cabinet that might close the vent holes.
The heated holding cabinet is available from the factory as a
120 VAC or 240 VAC unit for domestic use and as a 240 VAC unit
for foreign use. The data plate, located on the side of the module, will specify the correct electrical supply. The unit requires a
grounded receptacle with a separate electrical line protected by a
fuse or circuit breaker of the proper rating. For European markets, verify the electrical plug meets the proper electrical rating
and country type. See local authorities for proper standards.
To avoid electrical shock, the cabinet must be adequately
and safely grounded (earthed) according to local electrical
codes.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces
in close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol
Refer to the table below for electrical ratings for the HHC-900.
Product Number Volts Watts Amps
HHC-900 120 2086 17.5
HHC-903 120 1586 13.0
HHC-900 240 3086 13.0
HHC-900 240 2086 9.0
HHC-903 240 3086 13.0
HHC-903 240 2086 9.0
HHC-902 stackable 120 1586 13. 0
HHC-906 120 2086 17.5
HHC-908 120 2086 17.5
HC-15 240 2086 9.0
HC-5 240 2086 9.0
510 2-2