Model HHC-136/Model HCN-5
SECTION 2. INSTALLATION
2-1. INTRODUCTION This section provides the installation instructions for the Henny Penny
Heated Holding Cabinet.
Installation of this unit should be performed only by a qualified
service technician.
Do not puncture the skin of the unit with drills or screws as
component damage or electrical shock could result.
2-2. UNP ACKING
The Henny Penny Heated Holding Cabinet has been tested, inspected,
and expertly packed to ensure arrival at its destination in the best
possible condition. The cabinet rests on cardboard pads that sit on a
wooden skid. The racks inside the cabinet are secured with cardboard
packing. The unit is then packed inside a heavy cardboard carton with
sufficient padding to withstand normal shipping treatment.
Any shipping damages should be noted in the presence of the
delivery agent and signed prior to his or her departure.
T o remove the Henny Penny Heated Holding Cabinet from the carton,
you should:
1. Carefully cut banding straps.
2. Lift the carton off the unit.
3. Lift the unit off the cardboard padding and skid.
T ake care when moving the fryer to prevent personal
injury . The unit weighs 1 10 lbs. (49.9kg).
4. Open doors and remove packing from behind racks.
5. Peel off any protective covering from the exterior of the cabinet.
6. The unit is now ready for location and set up.
506 2-1
Model HHC-136/Model HCN-5
2-3. LOCA TION
Figure 1
2-4. ELECTRICAL
CONNECTION
The unit should be placed in an area where the doors can be opened
without interruption and loading and unloading of product is easy . For
proper operation, the cabinet must be level.
The unit MUST be mounted to the table-top, using the 4, 1/4-20 x
1-1/2 inch (38.1 mm) bolts and washers, supplied with the cabinet.
Screw the bolts up through the table and into the holes in the base of
the unit as shown in Figure 1.
The data plate, located on the side of the top module, will specify the
correct electrical supply . The heated holding cabinet is available from
the factory as a 120 or 240 VAC unit. The unit requires a grounded
receptacle with a separate electrical line protected by a fuse or circuit
breaker of the proper rating. For European markets, verify the
electrical plug meets the proper electrical rating and country type. See
local authorities for proper standards.
T o avoid electrical shock, the cabinet must be adequately
and safely grounded (earthed) according to local electrical
codes.
Refer to the table below for electrical ratings.
Product Number V olts Watts Amps
HHC-136 120 1320
240 1320 5.5
HCN-5 240 1320 5.5