2-1. INTRODUCTION This section provides the installation instructions for the Henny
Penny Holding Display Station.
Installation of this unit should be performed only by a qualified service technician.
Do not puncture the skin of the unit with drills or screws as component damage or electrical shock could result.
2-2. UNP ACKING The Henny Penny Holding Display Station has been tested,
inspected, and expertly packed to ensure arrival at its destination in the best possible condition. The unit is shipped in 3 separate cartons and have been bolted to a wooden skid. The units are then packed inside a triple wall corrugated carton with sufficient padding to withstand normal shipping treatment.
Any shipping damages should be noted in the presence of the delivery agent and signed prior to his or her departure.
T o remove the Henny Penny Holding Display Station from the carton, you should:
1. Carefully cut banding straps and remove units from packaging.
Be sure to keep the owners manual from the Randell refrigera­tion unit when unpacking the unit. Important warranty informa­tion is contained in the manual.
The data plate for the Randell refrigeration unit is located on the mechanical base, by the compressor.
605 2-1
2-3. ASSEMBLY
Figure 1
Model HDS-300
Due to the size and weights of the refrigeration unit and the top unit of the HDS-300, more than one person is needed to lift the pieces into place, or personal injury could result.
1. Using a Phillip’s head screwdriver , remove the screws securing the rear panel of the cold well on the table, and remove panel. Figure 1.
2. After the packaging has been removed from the refrigeration unit, pull up on the 4 mounting brackets on the sides of the refrigeration unit and remove the brackets. Figure 2.
Figure 2
Figure 3
3. Noting that the drain of the refrigeration unit goes towards the hot well, carefully lift the refrigeration unit and place into the open slot in the table top.
4. Pull the cord and plug through the hole in the top, rear shroud.
5. Reinstall the refrigeration brackets and secure the refrigeration unit in place by tightening the bolts against the table top. Figure 3.
6. Reinstall rear panel, removed in step 1.
7. Install the vented, stainless steel panel, supplied with the refrigeration unit, to the front of the refrigeration unit. Figure 4.
Figure 4
2-2 605
2-3. ASSEMBLY (Continued)
Figure 5
Model HDS-300
8. Using silicone sealant (silicone or equivalent sealant must be NSF listed material), seal the refrigeration unit to the table top. Figure 5.
Figure 6
9. Carefully lift the top unit onto the table top, making sure the french fry station element is over the french fry tray . Figure 6.
10. First, line up the 2 outside holes (circled), in the table top with the holes in the end channels of the top unit, and secure the units together using 2, 1/4-20 in these holes. Then screw 1/4-20 bolts in the remaining 4 holes. (total of 6 at each end.) Figure 7.