Model HDS-200/300
SECTION 4. TROUBLESHOOTING
4-1. TROUBLESHOOTING GUIDE
PROBLEM CAUSE CORRECTION
Product not • Cold well or hot well not • Check plugs under table-top
holding plugged-in on french fry end of HDS-300
temperature
• Product held too long • Only hold product for
recommended times
• Cold well setting turned • Turn control setting to about 6
• Compressor overheated • Clean condenser coil
• Product not a proper • Be sure product is at proper
temperature when placed temperature
into unit
• Defective fuse for refrigeration • Replace 15 amp fuse
unit
Refrigeration unit runs • Frost build-up • Defrost unit
constantly
• Condensor coil dirty • Clean condenser coil
Power switch on but • Open Circuit • Plug unit in
no power to unit
• Check circuit breaker
• Check 15 amp fuses
• Check cord and plug
for loose connection
Not all lights • Faulty light bulbs • Replace with new bulb,
on per Light Bulb Replacement
Section
Lights will • Defective fuse • Replace 15 amp fuse
not turn on
4-1 605