Fryer must be installed and used in such a way to prevent water from contacting the
shortening.
This appliance is not intended to be operated by means of an external timer or a separate
remote control system.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
This manual should be retained in a convenient location for future reference.
A wiring diagram for this appliance is located on the inside of the door.
Post in a prominent location, instructions to be followed in event user smells gas. This information shall
be obtained by consulting the local gas supplier.
Do not obstruct the ow of combustion and ventilation air. Adequate clearance must be left all around
appliance for sufcient air to the combustion chamber.
The Model EEG-10X open fryer is equipped with a continuous pilot. But the open fryer cannot be
operated without electric power, and no attempt should be made to operate the fryer during a power
outage. The unit will automatically return to normal operation when power is restored.
To avoid a re, keep appliance area free and clear from combustibles.
Improper installation, adjustment, alteration, service, or maintenance can
cause property damage, injury, or death. Read the installation, operating,
and maintenance instructions thoroughly before installing or servicing this
equipment.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
This appliance must be installed in accordance with the manufacturer’s instructions and the regulations
in force and only used in a suitable ventilated location. Read the instructions fully before installing or
using the appliance.
Noise generated from this equipment is less than 70 dB(A)
The instructions in this manual have been prepared to aid you
in learning the proper procedures for your equipment. Where
information is of particular importance or is safety related, the
words NOTICE, CAUTION, or WARNING are used. Their usage
is described below.
If a problem occurs during the rst operation of a new unit,
recheck the Installation Section of the Operator’s Manual.
Before troubleshooting, always recheck the Operation
Section of the Operator’s Manual.
Where information is of particular importance or is safety related,
the words DANGER, WARNING, CAUTION, or NOTICE are
used. Their usage is described as follows:
SAFETY ALERT SYMBOL is used with DANGER,
WARNING or CAUTION which indicates a personal
injury type hazard.
NOTICE is used to highlight especially important
information.
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
CAUTION used with the safety alert symbol indicates
a potentially hazardous situation which, if not
avoided, could result in minor or moderate injury.
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in death
or serious injury.
DANGER INDICATES AN IMMINENTLY
HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, WILL RESULT IN DEATH OR
SERIOUS INJURY.
1March 2014
1-1.
SAFETY
(CONT.)
Equipotential Ground Symbol
Waste Electrical and Electronic Equipment (WEEE) Symbol
OR
OR
Shock Hazard Symbols
Hot Surface Symbols
2March 2014
1-2.
INTRODUCTION
The Henny Penny open fryer is a basic unit of food processing equipment
designed to cook foods better and easier. The micro computer-based
design helps make this possible. This unit is used only in institutional and
commercial food service operations, and operated by qualied personnel.
•As of August 16, 2005, the Waste Electrical and Electronic
Equipment directive went into effect for the European Union. Our
products have been evaluated to the WEEE directive. We have
also reviewed our products to determine if they comply with the
Restriction of Hazardous Substances directive (RoHS) and have
redesigned our products as needed in order to comply. To continue
compliance with these directives, this unit must not be disposed as
unsorted municipal waste. For proper disposal, please contact your
nearest Henny Penny distributor.
1-3.
FEATURES
1-4.
PROPER CARE
• Easily cleaned
• Uses 40% less oil
• Full vat or split vat
• Computer control
• Stainless steel construction
• Automatic oil top off
• Self-diagnostic system built into controls
• Built in lter with automatic ltration
• Propane or natural gas; 75,000 BTU/vat (21.97 kw)
As in any unit of food service equipment, the Henny Penny
open fryer does require care and maintenance. Requirements for the
maintenance and cleaning are contained in this manual and must become
a regular part of the operation of the unit at all times.
Contact a qualied service technician in case of major maintenance
or repairs to the unit.
1-5.
ASSISTANCE
Should you require outside assistance, call your local independent
distributor in your area, or call Henny Penny Corp. at 1-800-417-8405 or
1-937-456-8405.
3March 2014
SECTION 2: INSTALLATION
2-1.
INTRODUCTION
2-2.
UNPACKING
This section provides the installation and unpacking instructions for the
®
Henny Penny Evolution Elite
Installation of this unit should be performed only by a qualied service
Do not puncture the fryer with any objects such as drills or screws as
component damage or electrical shock could result.
Any shipping damage should be noted in the presence of the delivery agent
and signed prior to his or her departure.
fryer.
technician.
1. Cut and remove the metal bands from the carton.
2. Remove carton lid and lift the main carton off the fryer.
3. Remove corner packing supports (4).
4. Cut the stretch lm from around the carrier/rack box and remove it
from the top of the fryer lid.
5. Cut and remove the metal bands holding the fryer to the pallet, and
remove fryer from pallet.
Remove lter drain pan and BIB shelf from fryer before removing fryer from
pallet or damage to the unit could result. Figure 1.
Take care when moving the fryer to prevent personal injury. The fryer
weighs approximately 600 lbs. (272 kg) to 800 lbs. (363 kg).
4March 2014
2-3.
SELECTING THE
FRYER LOCATION
The proper location of the fryer is very important for operation, speed,
and convenience. The location of the open fryer should allow clearances
for servicing and proper operation. Choose a location which will provide
easy loading and unloading without interfering with the nal assembly
of food orders. Operators have found that frying from raw to nish, and
holding the product in warmers provides fast continuous service. Keep
in mind, the best efciency will be obtained by a straight line operation,
i.e. raw in one side and nished out the other side. Order assembly can
be moved away with only a slight loss of efciency.
To avoid re, install the open fryer with minimum clearance from all
combustible materials, 2 inches (5.08 cm) from the side and 4 inches
(10.16 cm) from the back. Minimum clearance from all non-combustible
materials, 0 inches (0.00 cm) from the side and 0 inches (0.00 cm) from the
back. If installed properly, the open fryer is designed for operation on non-
combustible oors only
Do not spray aerosols in the vicinity of this appliance while it is in operation.
2-4.
LEVELING THE
FRYER
2-5.
VENTILATION OF
FRYER
To prevent severe burns from splashing hot oil, position and install
fryer to prevent tipping or movement. Restraining ties may be used for
stabilization.
For proper operation, the open fryer should be level from side-to-side and
front to back. Using a level placed on the at areas around the vat collar,
on the middle well, and then adjust the casters until the unit is level.
The fryer should be located with provision for venting into an adequate
exhaust hood or ventilation system. This is essential to permit efcient
removal of the steam exhaust and frying odors. Special precaution must
be taken in designing an exhaust canopy to avoid interference with the
operation of the fryer. We recommend you consult a local ventilation or
heating company to help in designing an adequate system.
Ventilation must conform to local, state, and national codes.
Consult your local fire department or building authorities.
5March 2014
2-6.
GAS SUPPLY
When installing the gas open fryer, do not attach an extension
to the gas ue exhaust stack. This may impair proper
operation of the burner, causing malfunctions and possible
negative back draft.
The gas open fryer is factory available for either natural or propane gas.
Check the data plate inside the left front door of the cabinet to determine
the proper gas supply requirements. The minimum supply for natural
gas is 7 inches water column (1.7 kPa) (17.0 mbar), and 10 inches water
column (2.49 kPa) (24.9 mbar) for propane.
Do not attempt to use any gas other than that specied on the
data plate. Incorrect gas supply could cause a re or explosion
resulting in severe injuries and/or property damage.
Please refer below for the recommended hookup of the fryer to main gas
line supply.
To avoid possible serious personal injury:
•Installation must conform with local, state,
and national
codes, the American National Standard
Z223.1/NFPA 54 -(the latest edition) National
Fuel Gas Code, and the local municipal
building codes. In Canada, the Natural
Gas and Propane Installation Code is CSA
B149.1 & Installation Codes - Gas Burning
Appliances and local codes. In Australia, in
accordance with Australian Gas Authority
rules AS5601.1/2-2010.
• The fryer and its manual shutoff valve must
disconnected from the gas supply piping
be
system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG
(3.45 kPa) (34.5 mbar).
•The fryer must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping
system at test pressures equal to or less than
1/2 PSIG (3.45 kPa) (34.5mbar).
•A standard one inch (2.54 cm), black steel
pipe and
malleable ttings should be used for gas
service connections for 3 & 4 well open
fryers, and 3/4 inch (1.91 cm) for 2 wells.
•Do not use cast iron ttings.
•Although one inch (2.54 cm) size pipe is rec-
ommended for 3 & 4 wells and 3/4 inch (1.91
cm) for 2 wells, piping should be of adequate
size and installed to provide a supply of gas
sufcient to meet the maximum demand
without undue loss of pressure between the
meter and the open fryer. The pressure loss
in the piping system should not exceed 0.3 in.
water column (0.747 mbar).
6March 2014
2-6.
GAS SUPPLY
(CONT.)
Provisions should be made for moving the open fryer for cleaning and
servicing. This may be accomplished by:
1. Installing a manual gas shutoff valve and a disconnect or union.
2. Installing a heavy-duty design CSA certied connector. In order to
be able to service this appliance, which is provided with casters,
a connector complying with ANSI Z21.69-CAN 6.16 or CAN
1-6.10m88 and a quick-disconnect device, complying with ANSI
Z21.41or CAN 1-6.9m70, must be installed. It must also be installed
with restraining means to guard against transmission of strain to the
connector as specied in the appliance manufacturer’s instructions.
3. See the illustration on the following page for the proper connection
of exible gas line and cable restraint.
The cable restraint limits the distance the open fryer can be pulled from
the wall. For cleaning and servicing the unit, the cable must be unsnapped
from the open fryer and the exible gas line disconnected. This allows better
access to all sides of the open fryer. The gas line and cable restraint must be
reconnected once the cleaning or servicing is complete.
7March 2014
2-6.
GAS SUPPLY
(CONT.)
For Australia or New Zealand:
Where a model is supplied with castors and is to be connected to a
xed gas supply via a exible hose connection, a restraining chain or wire of adequate strength shall be xed to the appliance and be suitable to be xed to the wall within 50
mm of each connection point. The
length of the chain or wire shall not exceed 80% of the length of the hose assembly.
-
8March 2014
2-7.
GAS LEAK TEST
2-8.
GAS PRESSURE
REGULATOR
SETTING
Prior to turning the gas supply on, be sure the gas valve knob on the gas
control valve is in the off position.
Upon initial installation, and after moving the unit, the piping and ttings
should be checked for gas leaks. A simple checking method is to turn on
the gas and brush all connections with a soap solution. If bubbles occur, it
indicates escaping gas. In this event, the piping connection must be redone.
To avoid re or explosion, never use a lighted match or open ame to
test for gas leaks. Ignited gas could result in severe personal injury and/
or property damage.
The gas pressure regulator on the gas control valve is factory set as follows:
•Natural: 3.5 inches water column (0.87 kPa) (8.72 mbar).
•Propane 10.0 inches water column (2.49 kPa) (24.9 mbar).
2-9.
ELECTRICAL
REQUIREMENTS
The gas pressure regulator has been set by Henny Penny and is not to be
adjusted by the user.
•
120 V, 50/60 Hz, 1 PH, 12 A
•230 V, 50 Hz, 1 PH, 7 A
The 120 volt gas fryer is factory equipped with a grounded (earthed)
cord and plug for your protection against shock, and should be plugged
into a three-prong grounded (earthed) receptacle. Do not cut or remove
grounding (earthing) prong. Any 230 volt plug used on the 230 volt unit
must conform to all local, state, and national codes.
To avoid electrical shock, this appliance must be equipped with an
external circuit breaker which incorporates a 3mm disconnection in all
ungrounded (unearthed) conductors. The main power switch on this
appliance does not disconnect all line conductors.
9March 2014
2-9.
ELECTRICAL
REQUIREMENTS
(CONT.)
To avoid electrical shock, do not disconnect the ground
(earth) plug. This fryer must be adequately and safely
grounded (earthed). Refer to local electrical codes for
correct grounding (earthing) procedures or in absence
of local codes, with The National Electrical Code, ANSI/
NFPA No. 70-(the current edition). In Canada, all electrical
connections are to be made in accordance with CSA C22.2,
Canadian Electrical Code Part 1, and/or local codes.
Disconnect power supply before a thorough cleaning or servicing the fryer.
2-10.
MOTOR BEARINGS
2-11.
LIGHTING AND
SHUTDOWN OF THE
BURNERS
The electric motor bearings are permanently lubricated. DO NOT
LUBRICATE.
Turn the power switch to the OFF position.
1.
2. Wait at least 5 minutes and then turn power switch to the ON position.
3. Press button on the controls (left or right).
4. The burner lights and operates in a Melt Cycle until the
shortening reaches a preset temperature.
5. Once the display shows a product selection or a double
dashes, press the desired product button.
The fryer is equipped with a ignition spark module which has a
set ignition safety time (TSA) of 90 seconds.
2-12.
TESTING THE
FRYER
To shutdown burner:
1. Press button on the controls (left or right).
2. Turn the power switch to the OFF position.
NOTE: This turns off all vats.
Each Henny Penny open fryer was completely checked and tested
prior to shipment. However, it is good practice to check the unit for
proper operation.
10March 2014
2-13.
DIMENSIONS
1-WELL
Back
Side dimensions are
the same for all units
Front
11March 2014
2-13.
DIMENSIONS
(CONT.)
2-WELL
Back
Side dimensions are
the same for all units
Front
12March 2014
2-13.
DIMENSIONS
(CONT.)
3-WELL
BackSide
Side dimensions are
the same for all units
13March 2014
2-13.
DIMENSIONS
(CONT.)
4 WELL
Back
14March 2014
SECTION 3: OPERATION
3-1.
OPERATING
COMPONENTS
Figure 3-1
1
2
Refer to explanations on the next pages.
4
25673
1
3
8
108
9
1112
Figure 3-2
Figure 3-3
13
Figure 3-4
15March 2014
3-1.
OPERATING
COMPONENTS
(CONT.)
Fig.
Item
No.
3-11
3-12
3-13
3-14
3-15
DescriptionFunction
This LED lights when the control calls for heat for the left/ right vat, and the
burners ignite and heat the oil
During normal operation, press this button to start and stop cook cycles for the
left basket; press to change displayed product; also used for √ to indicate YES
or to conrm
During normal operation, press this button to start and stop cook cycles for the
left basket; press to change displayed product; also used for X to indicate NO
or cancel
Shows the product codes; shows the timer countdown during cook cycles;
shows the prompts during the lter modes; shows the selections in the Program
Digital Display
Mode; shows the temperature of the oil by pressing ; shows error codes
(also displays in several languages)
Press once to view actual oil temperature; press twice to view oil set-point
temperature; and press three times to view recovery information for each vat
o
from 250
F-300oF (121oC-149oC). Used in Programming Modes; used as ◄
button to back-up to a previous parameter in Program and Filter Modes.
3-16
3-17
3-18
3-19
3-110
Used to access the Filter Menu; also used for ▲ or ▼ buttons; press once to
view the number of cook cycles before next lter in Global Filter or the mode
or percentage of lter allowance in Mixed Filter; press twice to view the time
and date of the most recent lter on each vat; press three times to view the
number of hours of use of the lter pad presently in the drain pan.
Used to access the Program Modes; used as ► button to advance to the next
parameters in Program and Filter Modes; press to select 2nd languages and
volumes
Press to turn on and off the heat system for the left vat(s); on full vats either
button can be used
Each product button LED lights when that particular product has been
selected, or when it is compatible with cook temperature.
Press to select the desired product; press to place the letters under the button,
during naming a product in Program Mode
The can be used to start an Idle Mode if enabled in Special Program Mode
16March 2014
3-1.
OPERATING
COMPONENTS
(CONT.)
Fig.
Item
No.
3-211
3-312
3-413
DescriptionFunction
A Filter Beacon® is found beside each black drain knob; when lit blue, indicates
the oil should be ltered at this time; beacon ashes when the drain needs
opened or closed
When the power switch is turned to the ON position, power is supplied to the
controls and pumps
For fryers with a bulk oil supply, press this button to ll the BIB
17March 2014
3-1.
OPERATING
COMPONENTS
(CONT.)
4
3
2
Item
No.
1Filter Drain Pan Assy. Oil is drained into this pan and then is pumped through lters to help
2Drain Valve Knob
3Basket RestThe baskets hang on this when not in use, or to drain the product after a
4Vat CoversCovers the vat when not in use
5BIB SupportArea that holds the Jug-in-a-Box; holds oil to be pumped into vats to top-
DescriptionFunction
prolong the use of the oil
Pull-out on black knobs to open drain valve and oil drains from vat; Push-
(Optional)
in to close drain valve and oil can be pumped into vat
cook cycle
off the oil level by the Oil Guardian™ process
15
18March 2015
3-2.
SET-UP MODE
Upon initial start-up, the controls will ask to conrm the settings for
the fryer.
When main power switch is turned on, “OFF” shows in both
displays. Press on either side and *SETUP* *ENTER CODE*
shows in display. Press 1, 2, 3, and “LANGUAGE” shows on the
left display, “ENGLISH” on the right display.
Use ▲ or ▼ buttons to change the operation display to:
Greek “EΛΛHNIKA”, Russian “РУССКИИ”, Swedish
“SVENSKA”, German “DEUTSCHE”, Portuguese “PORTUG.”,
Spanish “ESPANOL”, or French “FRANCAIS”.
Press ► to continue with the other set-up items which include:
• TEMP FORMAT -
• TIME FORMAT - 12-HR or 24-HR
• ENTER TIME - Time of day (use product buttons to change)
• ENTER TIME - AM or PM
• DATE FORMAT - MM-DD-YY or DD-MM-YY
• ENTER DATE - Today’s date (use product buttons to change)
• DAYLIGHT SAVING TIME - 1.OFF; 2.US (2007 & after);
o
F or oC
3.EURO; 4.FSA (US before 2007)
• FRYER TYPE - ELEC or GAS
• VAT TYPE - FULL OR SPLIT
• AUTOLIFT ENABLED? - NO LIFT or YES LIFT
• BULK OIL SUPPLY - YES or NO
• BULK OIL DISPOSE? - YES or NO
• S/N - Shows serial number of the unit or can be recorded (THIS
SERIAL NUMBER SHOULD MATCH THE SERIAL
• NUMBER ON THE DATA PLATE, ON THE DOORS.)
• 2nd LANGUAGE - By setting a second language in the controls,
2 languages can now be easily chosen by pressing during
normal operation. One language shows in left display and
second language shows in right display. Pressing the √ button
under desired language, selects that language seen in displays.
• 2nd VOLUME - By setting a second volume in the controls,
2 volumes can now be easily chosen by pressing twice
during normal operation. One volume setting shows in left
display (NONE to 10; 10 being the loudest) and a second
volume shows in right display. To select volume, press √ button
under desired volume.
• SETUP COMPLETE - OFF is displayed and unit shuts down.
Unless otherwise indicated, use ▲ or ▼ to change settings.
Setup Mode can also be accessed by re-initializing the controls, in Special
Program Mode, in Level 2 programming (SP-3).
19March 2014