2-7. Recommended Spare Parts for Distributors.......................................................... 2-1
206 FM06-013 i
Revised 02-13-07
Model CF-941
SECTION 1. MAINTENANCE
1-1. INTRODUCTION This section provides procedures for checking and
replacement of the various parts used within the cabinet.
1-2. SAFETY Where information is of particular importance or is safety
related, the words NOTICE, CAUTION, or WARNING
are used. Their usage is described below:
SAFETY ALERT SYMBOL is used with DANGER,
WARNING, or CAUTION which indicates a personal
injury type hazard.
NOTICE is used to highlight especially important
information.
CAUTION used without the safety alert symbol
indicates a potentially hazardous situation
which, if not avoided, may result in property damage.
CAUTION used with the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury.
WARNING indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
203 1-1
Model CF-941
1-3. TEST INSTRUMENTSYou may use two test instruments to check the electrical
components.
1. A continuity light.
2. An ohmmeter.
When the manual refers to the circuit being closed, the
continuity light will be illuminated or the ohmmeter
should read zero unless otherwise noted. When the
manual refers to the circuit being open, the continuity
will not illuminate or the ohmmeter will read one or
infinite resistance.
An ohmmeter must be used to check coils.
1-4. ERROR CODES
DISPLAY CAUSE PANEL BOARD CORRECTION
“E-4” Control board Turn switch to OFF position, then turn switch back to overheating ON; if display shows “E-4”, the control board is
getting too hot; make sure unit is not overheating
“E-6” Faulty temperature Check to see if unit is set to the correct number of
probe drawers, ex: “MP-942=2” drawers (see Operation
and Programming Section in Operator’s Manual)
“E-41” Memory scrambled Press and release the UP and DOWN buttons to
initialize the program; if “E-41” persists, replace the
control board
“Hi” Unit over-heating; Have relay or control board replaced
faulty relay or
controlboard
1-2 203
Model CF-941
1-5. CONTROL BOARD 1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage,
move the POWER switch to OFF and disconnect
main circuit breaker, or unplug cord at wall
receptacle.
2. Remove the two screws on the front of the control
panel and pull control drawer out.
3. Using a 5/16" socket, remove nuts securing the board
and remove board from the panel.
4. Remove the wires from the control board.
Step 35. Install new control board in reverse order.
Do notover-tighten nuts securing the control board,
or the buttons on the controls may not function.
1-6. POWER SWITCH1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage,
move the POWER switch to OFF and disconnect
main circuit breaker, or unplug cord at wall
receptacle.
2. Remove the two screws on the front of the control
panel and pull control drawer out.
Mark the wires when removing them from the switch
to be sure the switch is rewired correctly.
3. Remove the wires from the switch. Check for
continuity across the top and bottom terminals, on
both left and right side of the switch. With the switch
in the ON position, the circuit should be closed.
Step 3With the switch in the OFF position, the circuit
should be open. If the switch is defective, replace it
by continuing with this section.
203 1-3
Model CF-941
1-6. POWER SWITCH (Continued)
4. Squeeze the tabs on the back of the switch and pull
the switch out from the front of the panel.
5. Install new switch in reverse order.
Step 4
1-7. TRANSFORMER 1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage,
move the POWER switch to OFF and disconnect
main circuit breaker, or unplug cord at wall
receptacle.
2. Remove the two screws on the front of the control
panel and pull control drawer out.
Step 3
3. Label wires and remove them from the transformer.
4. Using a Phillips head screwdriver, remove the two
screws securing the transformer and remove the
transformer.
5. Install the new transformer in reverse order.
1-4 203
Step 5