Henny Penny AHC-993 Operator’s Manual

4 (1)
Henny Penny AHC-993 Operator’s Manual

OPERATOR’S

M A N U A L

HUMIDIFIED HOLDING CABINET

MODEL

AHC-990

AHC-993

R E G I S T E R WA R R A N T Y O N L I N E AT W W W. H E N N Y P E N N Y. C O M

 

 

 

Model AHC-990/993

 

 

TABLE OF CONTENTS

 

Section

 

 

Page

Section 1.

INTRODUCTION

 

 

1-1.

Humidified Holding Cabinet.................................................................................

1-1

 

1-2.

Features..................................................................................................................

1-1

 

1-3.

Proper Care............................................................................................................

1-1

 

1-4.

Assistance..............................................................................................................

1-1

 

1-5.

Safety.....................................................................................................................

1-2

Section 2.

INSTALLATION

 

 

2-1.

Introduction...........................................................................................................

2-1

 

2-2.

Unpacking..............................................................................................................

2-1

 

2-3.

Location.................................................................................................................

2-2

 

2-4.

Electrical Connection............................................................................................

2-2

 

2-5. Water Capacity & Connections.............................................................................

2-3

 

2-6.

Water Quality Requirements.................................................................................

2-3

 

2-7. Cabinet Dimensions and Weights..........................................................................

2-4

 

2-8.

AHC-993 Installation Guidelines..........................................................................

2-6

 

2-9.

AHC-990 Installation Guidelines..........................................................................

2-9

Section 3.

OPERATION

 

 

3-1.

Introduction...........................................................................................................

3-1

 

3-2.

Operating Controls................................................................................................

3-1

 

3-3. Start-Up.................................................................................................................

3-3

 

3-4.

Operation with Product..........................................................................................

3-4

 

3-5.

Cleaning Procedures..............................................................................................

3-4

Section 4.

PROGRAMMING

 

 

4-1.

Introduction...........................................................................................................

4-1

 

4-2.

“Hidden Buttons”..................................................................................................

4-1

 

4-3.

Clock Set...............................................................................................................

4-1

 

4-4.

Special Programming............................................................................................

4-3

Section 5.

TROUBLESHOOTING

 

 

5-1.

Troubleshooting Guide..........................................................................................

5-1

 

5-2. Error Codes and Warnings.....................................................................................

5-2

Feb 2012

i

 

 

Model AHC-990/993

 

 

 

SECTION 1. INTRODUCTION

 

 

1-1. HUMIDIFIED

The Henny Penny humidified holding cabinets are designed to

HOLDING CABINET

keep hot foods moist, while maintaining proper temperature. The

 

units are electronically controlled for easy use and for consistent

 

operation.

 

As of August 16, 2005, the Waste Electrical and Electronic

 

Equipment directive went into effect for the European Union.

 

Our products have been evaluated to the WEEE directive. We

 

have also reviewed our products to determine if they comply with

 

the Restriction of Hazardous Substances directive (RoHS) and

 

have redesigned our products as needed in order to comply. To

 

continue compliance with these directives, this unit must not be

 

disposed as unsorted municipal waste. For proper disposal, please

 

contact your nearest Henny Penny distributor.

1-2. FEATURES

• Electronically controlled humidity and temperature

 

• Lift-off doors

 

Stainless steel construction

 

Easily maintained

 

• Lift-out tray racks

 

• Full perimeter magnetic door seals

 

• Easy access to electrical controls

 

• Automatic water tank fill

1-3. PROPER CARE

As in any unit of food service equipment, the Henny Penny

 

humidified holding cabinet does require care and maintenance.

 

Requirements for the maintenance and cleaning are contained in

 

this manual and must become a regular part of the operation of

 

the unit at all times.

1-4. ASSISTANCE

Should you require outside assistance, just call your local

 

independent Henny Penny distributor in your area, or call Henny

 

Penny Corp. 1-800-417-8405 toll free or 1-937-456-8405.

Dec. 2010

1-1

Model AHC-990/993

1-5. SAFETY

The Henny Penny Humidified Holding Cabinet has safety

 

features incorporated. However, to ensure a safe operation,

 

read and fully understand the proper installation, operation, and

 

maintenance procedures. The instructions in this manual have

 

been prepared to aid you in learning the proper procedures.

 

Where information is of particular importance or safety related,

 

the words WARNING, CAUTION, and NOTICE are used. Their

 

usage is described below.

SAFETYALERT SYMBOLis used with DANGER, WARNING, or

CAUTION which indicates a personal injury type hazard.

NOTICE is used to highlight especially important information.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

CAUTION used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Dec. 2010

1-2

Model AHC-990/993

SECTION 2. INSTALLATION

2-1. INTRODUCTION

Installation of this unit should be performed only by a qualified service technician.

Do not puncture the skin of the unit with drills or screws, or component damage or electrical shock could result.

2-2. UNPACKING

The Henny Penny humidified holding cabinet has been

 

tested, inspected, and expertly packed to ensure arrival at its

 

destination in the best possible condition.

Note any shipping damage in the presence of the delivery agent and signed prior to his or her departure.

To remove the Henny Penny cabinet from carton:

1.Carefully cut banding straps.

2.Lift carton off the unit.

3.Lift the unit off the cardboard padding and skid.

Full-size cabinets weigh approximately 300 lbs. (136 kg). Care should be taken when lifting unit to prevent personal injury.

Dec. 2010

2-1

 

 

Model AHC-990/993

2-2. UNPACKING

4. Open doors and remove packing from behind racks and under

(Continued)

the water tank covers and remove the tape from the standpipe

 

in the bottom of the unit.

 

 

5. Peel off all protective covering from the exterior of cabinet.

 

6. The cabinet is now ready for location and use.

2-3. LOCATION

Place the humidified holding cabinet in an area that allows the

 

doors to be opened without interference of loading and unloading

 

product. Also, keep the unit level for proper operation.

 

No minimum clearances are required for the rear and sides of

 

the cabinet.

 

2-4. ELECTRICAL

 

 

CONNECTION

 

 

 

To avoid electrical shock, the cabinet must be adequately

 

and safely grounded (earthed) according to local

 

electrical codes, and this appliance must be equipped

 

with an external circuit breaker which will disconnect all

 

ungrounded (unearthed) conductors. The main power

 

switch on this appliance does not disconnect all line

 

conductors.

 

 

(FOR EQUIPMENT WITH CE MARK ONLY!)

 

To prevent electric shock hazard this appliance must be

 

bonded to other appliances or touchable metal surfaces

 

in close proximity to this appliance with an equipotential

 

bonding conductor. This appliance is equipped with an

 

equipotential lug for this purpose. The equipotential lug is

 

marked with the following symbol

.

If electrical supply to unit is a cord and plug, then the electrical receptacle for the plug, must be easily accessible. Refer to the table below for the electrical ratings for the cabinets.

 

AHC-993

 

 

 

 

 

Volts

Hertz

Phase

Amps

Watts

 

100

50/60

1

18.6

1855

 

120

60

1

18.9

2267

 

208

60

1

10.9

2267

 

220-240

50/60

1

9.1

2179

 

240

50-60

1

9.4

2263

April 2012

2-2

 

 

 

 

Model AHC-990/993

2-4. ELECTRICAL

AHC-990

 

 

 

 

CONNECTION

Volts

Hertz

Phase

Amps

Watts

(Continued)

120

60

1

24.0

2880

 

120

60

1

22.3

2680

 

200

50-60

1

13.2

2649

 

208

60

1

13.8

2880

 

240

50-60

1

12.0

2876

 

240

50-60

1

11.2

2676

 

220-240

50/60

1

11.6

2792

2-5. WATER CAPACITY &

Applies to the AHC-993 & AHC-990

CONNECTIONS

• Water Reservoir - 3 gal. (11.4 liters) capacity

 

 

- 2 gal. (7.6 liters) when in operation

 

1/4 in. cold water supply

 

1 in. or 3/4 in. drain connection

2-6. WATER QUALITY

To help ensure continued reliability of water components, shown

REQUIREMENTS

below is Henny Penny’s recommended water specification that

 

should be adhered to:

 

Acceptable Element and Compound Levels

 

Fe (Iron) < .1mg/l

 

Cl (Chlorine) < .1 mg/l

 

Cl2 (Chlorides and Salts) < 150 mg/l

 

General Water Properties

 

PH 7-8

 

Silica < 15 ppm

 

Hardness < 3 grains

 

Alkalinity < 20 ppm

 

Dissolved Solids < 60 ppm

 

Un-dissolved Solids < 5 microns

Nov. 2014

2-3

Model AHC-990/993

2-7. CABINET DIMENSIONS AND WEIGHTS

38 in. (965 mm)

24 3/4 in. (628 mm) 31 3/4 in. (806 mm)

 

 

AHC-993

 

 

Unit

Height

Width

Depth

Shipping Weight

AHC-993

38” (965 mm)

24-3/4” (628 mm)

31-3/4” (806 mm)

220 lbs (100 kg)

Feb 2012

2-4

Model AHC-990/993

2-7. CABINET DIMENSIONS AND WEIGHTS (Continued)

72 1/4 in.

(1835 mm)

24 3/4 in. (628 mm)

 

31 3/4 in. (806 mm)

 

 

AHC-990

Unit

Height

Width

Depth

Shipping Weight

AHC-990

72-1/4” (1835 mm)

24-3/4” (628 mm)

31-3/4” (806 mm)

367 lbs (167 kg)

Feb 2012

2-5

Loading...