Model CF-941
SECTION 2. INSTALLATION
2-1. INTRODUCTION This section provides the installation instructions for the
Henny Penny Multipurpose Holding Cabinet.
Installation of this unit should be performed by a
qualified service technician.
Do not puncture the skin of unit with drills or
screws as component damage or electrical shock
could result.
2-2. UNPACKING The Henny Penny Multipurpose Holding Cabinet has
been tested, inspected, and expertly packed to ensure
arrival at its destination in the best possible condition.
The cabinet rests on cardboard pads that sit on a wooden
skid. The unit is then packed inside a heavy cardboard
carton with sufficient padding to withstand normal
shipping treatment.
Any shipping damages should be noted in the
presence of the delivery agent and signed prior to his
or her departure.
To remove the Henny Penny Multipurpose Holding
Cabinet from the carton, you should:
1. Carefully cut banding straps.
2. Lift carton off the unit.
3. Lift the unit from the cardboard pads.
Care should be taken when lifting unit to
prevent personal injury. The unit weighs
approximately 67 lbs. (30 kg).
4. Open drawers and remove the packing or
literature that is inside.
103 2-1
Model CF-941
2-2. UNPACKING (Continued) 5. Pull off any protective covering from the
exterior of the cabinet.
6. Your multipurpose holding cabinet is now ready
for location and setup.
2-3. ELECTRICAL The multipurpose holding cabinet is available from
REQUIREMENTS the factory as a 120 VAC unit. The unit is single phase
and requires a grounded receptacle with a separate
electrical line protected by a fuse or circuit breaker of the
proper rating.
To avoid electrical shock, the cabinet must be
adequately and safely grounded (earthed)
according to local electrical codes.
DATA TABLE:
2-4. CABINET DIMENSIONS
Model
Number Volts Phase Watts Amps
CF-941 120 1 475 3
2-2 103