SECTION 2. INSTALLATION
2-1. INTRODUCTION This section provides the installation and unpacking instructions for
the Henny Penny cold bases.
Installation of this unit should be performed only by a qualified service technician.
Do not puncture the unit with any objects such as drills or screws, or component damage or electrical shock could result.
expertly packed to insure arrival at its destination in the best possible condition. The grids are packed separately inside the unit. The cabinet rests on a wooden skid and is then packed inside a heavy cardboard carton with sufficient padding to withstand normal shipping treatment.
To avoid damage to the components, do not lay the unit on its side. If the unit has been on its side, the unit must be in an upright position for at least 4 hours before power is applied to the unit.
Check all components, for signs of being loose or damĀ­aged, and make sure the system has refrigerant.
When moving the cold base be careful not to damage the refrigerant circuit.
Any shipping damage should be noted in the presence of the delivery agent and signed prior to his or her departure.
To remove the Henny Penny cold base from the carton:
1. Carefully cut banding straps.
2. Lift the carton off the unit.
3. Lift the unit off the skid.
303 2-1
Model CBC/CBR-103,104,105,106,107
2-2. UNPACKING (Continued)
Take care when moving the unit to prevent personal injury or damage to the refrigeration system. The units weigh between 400 (182 kg) and 580 lbs. (263 kg).
4. Peel off any protective covering from exterior of the cabinet.
5. Install the grids into unit.
6. Your cold base is now ready for operation.
2-3. ELECTRICAL The cold base is available as a 120 VAC, 60 Hz. or 230VAC,
50Hz, single phase unit, both for domestic and international use. The data plate, located beside the power cord, specifies the correct electrical supply. The cold bases are shipped with cord and plug, and requires a grounded receptacle with a separate electrical line protected by a fuse or circuit breaker of the proper rating. Position the unit so the power cord receptacle is accessible.
To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors.
Refer to the table below for electrical ratings:
Model No. Volts Amps Phase Max. Fuse Size
CBC-103 120 8.1 1 15 CBC-103 230 5.8 1 15 CBC-104 120 8.1 1 15 CBC-104 230 7.3 1 15 CBC-105 120 9.5 1 15 CBC-105 230 7.5 1 15 CBC-106 120 9.5 1 15 CBC-106 230 7.5 1 15 CBC-107 120 9.5 1 15 CBC-107 230 7.7 1 15
2-2 303