Heatiator GB4336 User Manual

Models: GB4336, GB4336L, GB4336I, GB4336IL, GB4942, GB4942L, GB4942I, GB4942IL B-Vent Gas Appliance
Owner’s Manual
Installation and Operation
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instructions included.
Read, understand and follow these instructions for safe installation and operation.
WARNING
If the information in these instruc­tions is not followed exactly, a fi re may result causing property damage, personal injury, or death.
• Do not store or use gasoline or other fl am­mable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency, or
the gas supplier.
Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certifi ed or factory-trained professionals, or technicians supervised by an NFI certifi ed professional.
DO NOT
DISCARD
Leave this manual with party responsible for use and operation.
WARNING
HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as appliance.
• Alert children and adults to hazards of high temperatures.
• Do NOT operate with protective barriers removed or door open.
• Keep clothing, furniture, draperies and other combustibles away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas fi tter.
• a CO detector shall be installed in the room where the appliance is installed.
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for
Installation in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on the rating plate.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 1
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Heatilator gas appliance—an elegant and clean alternative to wood burning appliances. The Heatilator gas appliance you have selected is designed to provide the utmost in safety, reliability, and effi ciency.
As the owner of a new appliance, you’ll want to read and carefully follow all of the instructions contained in this owner’s
The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.
Your new Heatilator gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Heatilator family of appliance products!
manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference. We suggest you keep it with your other important documents and product manuals.
We recommend that you record the following pertinent
Homeowner Reference Information
information about your appliance:
Model Name: Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
Listing Label Information/Location
The model information regarding your specifi c appliance can be found on the rating plate located in the control area of the appliance.
Serial #
XXXXXXXXX
XXXX
CERTIFIED
FOR CANADA
CERTIFIÉ POUR LE
CANADA
Orifice Size
Model #
Gas Type
Hearth & Home Technologies Inc
1915 W. Saunders Street Mt. Pleasant, IA 52641
ANSI Standard
MODEL MFG. DATE MODÈLE DATE DE FAB.
GAS TYPE/TYPE DE GAZ NATURAL/NATUREL PROPANE ALTITUDE 0-2000 2000-4000 FT/PI 0-2000 2000-4000 FT/PI MAX INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH MIN INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH MANIFOLD PRESSURE/PRESSION TUBULAIRE MAX. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU MIN. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU MIN. INLET PRESS. XX IN. W.C./C. D'EAU 1XX IN. W.C./C. D'EAU FOR THE PURPOSE OF INPUT ADJUSTMENT PRESS. MIN. D'ALIMENTATION ORIFICE SIZE DIAM. DE L'INJECTEUR XX/XX DIA. in./mm XX/XX DIA. in./mm
XXXXXX
SERIAL NO. DE SÉRIE
LESS THAN/MOINS DE 3 AMPÈRES., 115V., 60 Hz
DO NOT REMOVE OR COVER THIS LABEL. VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL. FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE.
2 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
Table of Contents
1 Listing and Code Approvals 4
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . 4
E. Non-Combustible Materials . . . . . . . . . . . . . . . . . . . . . 4
F. Combustible Materials . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Getting Started 5
A. Design and Installation Considerations . . . . . . . . . . . . 5
B. Negative Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . 7
D. Inspect the Appliance and Components . . . . . . . . . . . 7
3 Framing and Clearances 8
A. Select Appliance Location . . . . . . . . . . . . . . . . . . . . . . 8
B. Construct the Appliance Chase . . . . . . . . . . . . . . . . . . 9
C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
D. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4 Termination Locations 12
A. Vent Termination Minimum Clearances . . . . . . . . . . . 12
5 Vent Information and Diagrams 13
A. Vent Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B. Vent System Confi guration . . . . . . . . . . . . . . . . . . . . 13
6 Vent Clearances and Framing 15
A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . .15
B. Wall Penetration Framing . . . . . . . . . . . . . . . . . . . . . 15
C. Vertical Penetration Framing . . . . . . . . . . . . . . . . . . .15
7 Appliance Preparation 16
A. Installing Outside Air Kit Damper Assembly . . . . . . . 16
B. Gas and Electrical Connections . . . . . . . . . . . . . . . .17
C. Securing and Leveling Appliance . . . . . . . . . . . . . . . 17
8 Installing Vent Pipe 18
A. Assemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . 18
B. Attach Vent to Firebox Assembly . . . . . . . . . . . . . . . 18
C. Securing Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 18
9 Gas Information 19
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . 20
10 Electrical Information 21
A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . 21
B. Connecting to the Appliance . . . . . . . . . . . . . . . . . . . 21
C. Intellifi re Ignition System Wiring . . . . . . . . . . . . . . . .21
D. Standing Pilot Ignition System Wiring . . . . . . . . . . . .22
E. Junction Box Installation . . . . . . . . . . . . . . . . . . . . . . 23
11 Finishing 24
A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
12 Appliance Setup 25
A. Remove the Shipping Materials . . . . . . . . . . . . . . . . 25
B. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . .25
C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
D. Install the Refractory . . . . . . . . . . . . . . . . . . . . . . . . .25
E. Lava Rock, Vermiculite, Rockwool Placement . . . . . 25
F. Log Removal/Replacement . . . . . . . . . . . . . . . . . . . .26
G. Glass Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
H. Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
I. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
13 Operating Instructions 28
A. Before Lighting Appliance . . . . . . . . . . . . . . . . . . . . . 28
B. Check Appliance Draft . . . . . . . . . . . . . . . . . . . . . . . . 29
C. High Limit Safety Switch . . . . . . . . . . . . . . . . . . . . . . 29
D. Lighting the Appliance . . . . . . . . . . . . . . . . . . . . . . . . 30
E. After the Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . 32
F. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . 32
14 Troubleshooting 33
A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . 33
B. Intellifi re Ignition System . . . . . . . . . . . . . . . . . . . . . .35
15 Maintaining and Servicing the Appliance 37
16 Reference Materials 39
A. Appliance Dimension Diagram . . . . . . . . . . . . . . . . . 39
B. Service Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C. Optional Components . . . . . . . . . . . . . . . . . . . . . . . . 48
D. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . 51
E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Note: An arrow () found in the text signifi es change in content.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 3
1
Listing and Code Approvals
A. Appliance Certifi cation
MODELS: GB4336/GB4942 Series LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: B-Vent Gas Appliance STANDARD: ANSI Z21.50-2000/CSA 2.33-2000, IR41,
P4 and IR55
This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Al­titudes”.
This model (natural gas and propane) can be installed in a bedroom (in the United States) which has a total volume of unconfi ned space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54
(current edition), The Uniform Mechanical Code - (cur­rent edition), and local building offi cials for the options al-
lowed in obtaining an effective bedroom volume of uncon­fi ned space.
This model (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat is installed with the ap­pliance. Consult local code authorities.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either
supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Geneva 4336 Series 4942 Series
Input Rate (NG) 34,000 BTU/hr. 36,000 BTU/hr.
Input Rate (LP) 34,000 BTU/hr. 36,000 BTU/hr.
Orifi ce Size (LP) #52 #51
Orifi ce Size (NG) #35 #32
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang­ing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop­er orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defi ned by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certifi ed to the requirements of ANSI Z97.1 and
CPSC 16 CFR 1202 (Safety Glazing Certifi cation Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Section
1201.5 “Certifi cation and labeling requirements” which refers
to 15 U.S. Code (USC) 2063 stating “…Such certifi cate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
Note: Glass doors are not optional in the Commonwealth of Massachusetts. They are required.
4 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
Do NOT use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
E. Non-Combustible Materials
Materials that are reported as passing ASTM E 136, Stan­dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750° C, shall be considered non-combus-
tible materials.
F. Combustible Materials
Materials made of or surfaced with wood, compressed pa­per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or whether plastered or unplastered shall be considered combustible materials.
WARNING
2
Getting Started
2
A. Design and Installation Considerations
Heatilator B-vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult insurance carrier, local building, fire offi cials or authorities having jurisdiction about restrictions, installation inspection, and permits.
When planning an appliance installation, it’s necessary to determine the following information before installing:
• Where the appliance is to be installed. See Section 3.
• The vent system confi guration to be used. See Sections
4 and 5.
• Gas supply piping. See Section 9.
• Electrical wiring. See Sections10
• Framing and finishing details. See Sections 3, 6
and 11.
• Whether optional accessories—devices such as a fan, wall
switch, or remote control—are desired. See Section 10.
WARNING
Keep appliance dry.
• Mold or rust may cause odors.
• Water may damage controls.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 5
B. Negative Pressure
WARNING
Asphyxiation Risk
• Negative pressure can cause spillage of combustion fumes and soot.
• Fire needs to draft properly for safe operation.
Draft is the pressure difference needed to vent fi replaces successfully. Considerations for successful draft include:
• Preventing negative pressure.
• Location of fi replace and chimney.
Negative Pressure
Negative pressure results from the imbalance of air avail­able for the fi replace to operate properly. Causes for this imbalance include:
• Exhaust fans (kitchen, bath, etc.).
• Range hoods.
• Combustion air requirements for furnaces, water heaters and other combustion appliances.
• Clothes dryers.
• Location of return-air vents to furnace or air conditioning.
• Imbalances of the HVAC air handling system.
• Upper level air leaks (recessed lighting, attic hatch opening, duct leaks).
To minimize the effects of negative air pressure, the follow­ing must be considered:
• Install the outside air kit. Install the intake on the side of the house towards prevailing winds during the heating season.
• Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment.
• Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fi replace.
• Avoid installing the fi replace near doors, walkways or small isolated spaces.
• Recessed lighting should be a “sealed can” design; attic hatches weather stripped or sealed; attic mounted duct work and air handler joints and seams taped or sealed.
• Basement installations should be avoided due to stack effect. Stack effect creates negative pressure in lower levels. Hearth & Home Technologies recommends the use of direct vent fi replaces in basements.
Location of the fi replace and chimney will affect performance. As shown in Figure 2.1 the chimney should:
• Be installed through the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fi re.
• Penetrate the highest part of the roof. This minimizes the effects of wind turbulence.
• Be located away from trees, adjacent structures, uneven roof lines and other obstructions.
Offsets can restrict draft so their use should be minimized. Consider the fi replace location relative to fl oor and ceiling and attic joists.
Location
Not
Recommended
Windward
Figure 2.1 Recommended Chimney Locations
Marginal Location
Recommended
Location
Multi-level Roofs
Recommended
Location
Location
Not
Recommended
Leeward
6 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
C. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits (1/4 in.) Plumb line Safety glasses Level Manometer Voltmeter Tape measure Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan).
D. Inspect the Appliance and Components
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
The following B-vent components are needed for installa­tion. See Figure 2.2.
• Appliance
• Pipe components
• Firestops
• Attic insulation shield
• Elbows
• Strapping
• Roof fl ashing or chase top
• Termination cap
• Storm Collar
• Carefully remove the appliance and components from the packaging.
• The vent system components and trim doors are shipped in separate packages.
• The gas logs may be packaged separately and must be fi eld installed.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
• Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t.
Vertical
Termination
Cap
Storm Collar
Roof
Flashing
Ceiling
Firestop
B-Vent Pipe
Sections
Figure 2.2 Typical Vertical Installation
WARNING
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 7
3
Framing and Clearances
3
Note:
• Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference.
A. Select Appliance Location
When selecting a location for your appliance it is important to consider the required clearances to walls (See Figure 3.1).
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings.
• For service access.
Locate appliance away from traffi c areas.
Note: For actual appliance dimensions refer to Section 16.
1/2 in. (13 mm) min.
appliance
to combustibles
B
B
C
Drywall
A
In addition to these framing dimensions, also reference the following sections:
• Clearances and Mantel Projections (Sections 3.C. and 3.D.)
• Vent Clearances and Framing (Section 6)
A
A
48 in.
(1219 mm)
max.
Alcove
Installation
C
Model # A B C
4336 Series
4942 Series
Figure 3.1 Appliance Locations
8 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
in. 43 51-3/4 24
mm 1092 1314 610
in. 49 56 24
mm 1245 1422 610
B. Construct the Appliance Chase
A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.
Construction of the chase may vary with the type of build­ing. These instructions are not substitutes for the require­ments of local building codes. Local building codes MUST be checked.
Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.
Walls, ceiling, base plate and cantilever fl oor of the chase should be insulated. Vapor and air infi ltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, Hearth & Home Technologies recom­mends that the inside surfaces be sheetrocked and taped for maximum air tightness.
To further prevent drafts, gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced insulation. If the appliance is being installed on a cement slab, we recommend that a layer of plywood be placed underneath to prevent conducting cold up into the room.
WARNING
Fire Risk
• Construct chase to all clearance specifi cations in manual.
• Locate and install appliance to all clearance specifi cations in manual.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 9
C. Clearances
1/2 in.
(13 mm)
Combustible flooring may be installed next to the front of the appliance.
1/2 in. (13 mm)
Drywall
0 in.
WARNING
Fire Risk Odor Risk
• Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
• Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.
• Do NOT place furniture or any other combustible household objects within 36 in. of the appliance front.
Per Vent Manufacturer’s
Specifications
30 in.
(762 mm)
to ceiling
36 in.
(914 mm)
Combustible Object
0 in.to level of standoffs
B
0 in.
C
A
A
Rough Opening
Model #
4336 Series in. 43 39-3/4 24
mm 1092 1010 610
4942 Series in. 49 39-3/4 24
mm 1245 1010 610
(Width)
Rough Opening
B
(Height)
C
Rough Opening
(Depth)
Figure 3.2 Clearances to Combustibles
10 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
D. Mantel Projections
30 in. minimum
to ceiling
18
17
16
15
14
13
3 - 12
0 - 3
9-3/8
Figure 3.3 Clearances to Mantels or Other Combustibles Above
13-1/4
Measured from top of hood (in inches)
Appliance
14-3/4
14
16-1/4
15-1/2
17-3/4
17
Top o f Appliance
Drywall
A
48 in.
(1219 mm)
B
max.
Mantel Leg or
Perpendicular Wall
1 in. (25mm) min.
A
to perpendicular wall 3-1/2 in. (89 mm) min.
B
from fireplace opening to perpendicular wall
Figure 3.4 Clearances to Combustible Mantel Legs or Wall Projec-
tions (acceptable on both sides of opening)
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 11
4
Termination Lo cations
4
A. Vent Termination Minimum Clearances
Figure 4.1 specifi es minimum vent heights for various pitched roofs.
8 ft
Termination
Cap
Storm Collar
Roof
Flashing
(2.44 mm)
Lowest
Discharge
Opening
12
H (min.) - Minimum height from roof to lowest discharge opening.
Vertical wall
X
Roof Pitch is X / 12
Fire Risk Explosion Risk
Maintain vent clearance to combustibles as specifi ed.
• Do not pack air space with insulation or
Failure to keep insulation or other materials away from vent pipe may cause fi re.
(457 mm)
Gas
Termination
WARNING
other materials.
Gas, Wood or Fuel
Oil Termination
18 in.
A
8 ft
(2.44 m)
(minimum) to
Perpendicular
Wall
(gas only)
Roof Pitch H (Min.) Ft. Roof Pitch H (Min.) Ft.
Flat to 6/12 1.0* Over 11/12 to 12/12 4.0 Over 6/12 to 7/12 1.25* Over 12/12 to 14/12 5.0 Over 7/12 to 8/12 1.5* Over 14/12 to 16/12 6.0 Over 8/12 to 9/12 2.0* Over 16/12 to 18/12 7.0 Over 9/12 to 10/12 2.5 Over 18/12 to 20/12 7.5 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 8.0
* 3 ft. minimum in snow regions
Figure 4.1
Minimum Height from Roof to Lowest Discharge Opening
Gas Termination Wood & Fuel Oil Termination A 6 in.
Figure 4.2 Multiple Vertical Termination
(152 mm) 20 in. (508 mm)
12 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
5
Vent Information and Diagrams
5
A. Vent Guidelines
CAUTION
WARNING
Fire Risk Asphyxiation Risk
This appliance requires the specifi ed pipe
for operation.
• Incorrect pipe may cause spillage, condensation and overheating.
These models require the following size B-Vent double wall vent pipe.
Model Pipe Size
GB4336 Series in. 6
mm 152
GB4942 Series in. 6
mm 152
• Follow pipe manufacturer’s installation guidelines when installing the appliance.
ALL vent configuration specifications MUST be followed.
• This product is tested and listed to appliance and vent manufacturer’s specifi cations.
• Appliance performance will suffer if specifi cations are not followed.
B. Vent System Confi guration
• Rise to Run Ratio: 2:1
• Maximum Total Horizontal Run: 20 ft
• Minimum Total Vertical Rise: 9 ft
• Maximum Total Vertical Rise: 40 ft
• Maximum Number of Elbows: Four 45°
• Maximum Number of 90° Elbows: Four
A maximum of four 90-degree elbows may be used on this appliance when used in confunction with the fi xed glass doors listed below:
• DF361B/S
• DF421B/S
WARNING
Fire Risk Explosion Risk Asphyxiation Risk
Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or other appliances connected to the fl ue.
9 ft (2.74 m) min.
40 ft (12.19 m) max.
Minimum
clearances are
per vent
manufacturer's
specifications
Metal
plumber's strap
secured to
framing
Vent supports are per
vent manufacturer's
specifications
Figure 5.1 Vertical Termination Clearances
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 13
Vent supports
are per vent
manufacturers
specifications.
Maximum horizontal
20 ft (6.1 m)
Metal
Plumbers'
Strap
Maximum horizontal run is 50% of vertical. Horizontal run cannot be
more than 20 ft. (6.1 m).
Figure 5.2 Maximum Horizontal Run
WARNING
Fire Risk Explosion Risk
Insulation and other combustibles must not infringe on clearances.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
45°
Elbow
90°
Elbow
Offsets exceeding
45° adapt horizontal
limitations
Note: Maximum horizontal distance is 50% of vertical vent height.
Note: 90-degree elbows are not allowed without a fi xed glass door. Only 45-degree elbows or less are allowed. A straight section is not reuqired before the fi r s t e l b o w .
Figure 5.3 Maximum Horizontal Run
14 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
6
Vent Clearances and Framing
6
A. Pipe Clearances to Combustibles
WARNING
Fire Risk Explosion Risk
Maintain vent clearance to combustibles as specifi ed.
• Do not pack air space with insulation or other materials.
• National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Follow vent pipe manufacturer’s instructions for all clear­ances around pipe.
B. Wall Penetration Framing
Do not pack with insulation or other materials.
Use manufacturer's installation instructions for framing dimensions
Figure 6.1 Exterior Wall Hole
For a wall penetration consult B-vent pipe manufacturer’s instructions. Use same dimensional framing materials as those used in the wall construction.
Note: This appliance MUST terminate vertically.
C. Vertical Penetration Framing
Use B-vent manufacturer’s fi restops to provide adequate clearances.
WARNING
Fire Risk
Keep loose materials or blown insulation
from touching the vent pipe.
• National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
• Hearth & Home Technologies requires the use of an attic shield.
Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06 15
7
Appliance Preparation
7
CAUTION
Sharp Edges
• Wear protective gloves and safety glasses during installation.
A. Installing Outside Air Kit Damper Assembly
WARNING
Fire Risk Asphyxiation Risk
Maintain vent clearance to combustibles as specifi ed.
• Do not pack air space with insulation or other materials.
• National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
CAUTION
Risk of Smoke Spillage
Outside air inlet must be located to prevent blockage from:
• Leaves
• Snow/ice
• Other debris Blockage may cause combustion air starvation.
This appliance will operate correctly only if adequate ventia­tion is provided to allow proper draft to the system.
An outside air kit is available as an optional feature with this appliance. An outside air kit helps to decrease the amount of room air taken by utilizing outside air for combustion. We strongly recommend that it be installed.
Note: The outside air kit inlet thimble should be positioned in a manner that will not allow snow, leaves, etc. to block the inlet. A 3 ft. (.91 m) minimum height difference must be maintained from the top of the uppemost chimney section to the outside combustion air inlet. Reference Section 2.
• The outside air kit can only be installed on the left side of the appliance.
• Refer to the installation instructions provided with the kit.
WARNING
Fire Risk Asphyxiation Risk
Do not draw outside combustion air from:
• Wall, fl oor or ceiling cavity.
• Enclosed space such as an attic or garage.
• Close proximity to exhaust vents or chimneys.
Fumes or odor may result.
Figure 7.1 Outside Air Kit Handle Location
• Grasp the small black handle located on the side of the appliance. See Figure 7.1.
• Lift handle and pull towards front. Outside air door should open.
• Place handle in slot on bracket so outside air door remains open.
• When through burning appliance, grasp handle and push outside air door closed.
NO
Outlet blocked by snow, leaves, etc.
YES
Clear area
outside
house or in
ventilated
crawl space
Figure 7.2 Outside Combustion Air Placement
NO
Garage or
combustible
liquids storage
Factory-built
Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except small dip for cold air trap which will help prevent flow of cold air).
NO
Attic space
fireplace
NO
Outlet placed
higher than 3 ft
below the
termination cap
16 Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06
Loading...
+ 36 hidden pages