This Heat-Zone-QFP Air Duct Adaptor Kit has been tested for use with QFP44. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspec­tions. If you encounter any problems regarding code approvals, or if you need clarifi cation of any of the instructions con- tained here, contact the Technical Services Dept., Hearth & Home Technologies Inc., 1445 North Highway, Colville, WA 99114, phone 1-800-926-4356.
Contents of Kit
• HEAT-ZONE-GAS Air Duct Kit
• Adaptor Cover Plate (4051-157)
• Heat Zone Adaptor (4051-034)
The adaptor cover plate and Heat Zone Adapter must be installed on the QFP44 prior to installing the Heat-Zone-Gas Air Duct Kit.
Installation:
• Remove the cover plate from the top of the fi replace and discard it.
• Install the adaptor cover plate on top of the fi replace where the original cover plate had been using the previously removed screws.
• Using the adaptor cover plate as a guide, cut the insulation and remove. See Figure 1.
Sharp Edges
• Wear protective gloves and safety glasses during installation.
CAUTION
Top of Heat Zone Adaptor
Adaptor Cover Plate
Figure 1 Cutting the Insulation
• Install the Heat Zone adaptor by sliding into the hole of the cover plate. See Figure 2. Line up the holes in the top of the adaptor with the holes in the adapter cover plate.
• Attach the 6 in. round air duct from the Heat-Zone-Gas Air Duct Kit to the top of the unit by lining up the holes in the adaptor cover plate (Figure 1), the top of the adaptor (Figure 2) and this duct. See Figure 3.
• Follow the installation instructions included with the HEA T­ZONE-GAS Air Duct Kit to complete installation.
Hearth & Home Technologies Inc. • HEAT-ZONE-QFP • 4051-328 Rev A • 08/06
Figure 2 Installing the Heat Zone Adaptor
Figure 3 Installing the Round Air Duct