Heat & Glo Heat-Duct Air Duct Kit INSTALLATION AND OPERATION INSTRUCTIONS

Heat-Duct Air Duct Kit
INSTALLATION AND OPERATION INSTRUCTIONS
APPROVALS
The Heat-Duct air duct kit is for use only on approved Hearth Technologies gas fireplaces.
The flexible duct is manufactured and marked to the requirements of UL-181, Class I air duct.
INTRODUCTION
The Heat-Duct accessory kit conveys warm air from the fireplace through air duct(s) to the entire house via the furnace ductwork (see figure 1). One or two Heat­Duct kits can be installed on the fireplace.
Figure 1
Possible Air Duct Runs/Locations
PRELIMINARY PREPARATION
20-ft. length of 6” round duct
Fan duct assembly
Junction box
Wall switch
Flex duct collar
Fan duct collar
Hardware
If any parts are missing or damaged, contact your Dealer before starting installation. DO NOT install a damaged kit.
Underwriters
Laboratories Listed
PULL
SYSTEM
RETURN PLENUM
FURNACE
Printed in U.S.A. Copyright 2001, Hearth Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044
PUSH
SYSTEM
660-955C 12/01
This kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation.
CAUTION: All wiring should be done by a qualified electrician and in compliance with local codes and with the National Electric Code ANSI/NFPA No. 70-current (In the United States), or with the current CSC22.1 Canadian Electric Code (in Canada).
Installation of this kit MUST be performed by a qualified service technician.
Plan the location of the fireplace and the warm air duct run(s).
The Heat-Duct kit is carefully engineered and must be installed only as specified. If it or any of its components are modified, the warranty will be void. Modification may
MAXIMUM Duct Run = 20-ft. (6.1m) for useful heat output.
also cause a fire hazard. Installation must be done according to applicable local, state, provincial, and/or national codes.
MINIMUM Duct Run = NA - for runs out from the fireplace to adjacent duct.
INSTALLATION
Decide if the fan is going to be mounted to the unit (push system) or if the fan is going to be mounted to the duct return plenum (pull system). Airflow direction is indicated on the fan duct housing. The fan and connections must be accessible for servicing per local code requirements.
If the fan is going to be mounted to the fireplace
(push system):
• Remove the knockout from the side of the fireplace and discard it.
• Center the fan duct collar (the collar without crimping on the end) around the exposed hole and attach it to the fireplace with 3 screws. NOTE: Do this BEFORE final positioning of the fireplace (see Figure 2).
• Slide the fan duct assembly onto the collar and secure with three screws. The arrow on the duct should point away from the fireplace. Spin the fan blades and check for ob­structions.
• Cut a round 6” hole into the main return plenum of the furnace ductwork. Mount the flex duct collar onto the main return plenum of the furnace ductwork and secure with three screws.
• Connect the fan duct with the flex duct collar using the flex duct provided. NOTE:
Figure 2
Fold outer poly layer of flex­ible duct back to maintain clearance to combustibles on the fireplace. Secure liner to the collar with clamp.
• Support duct at intervals of no greater than four feet, no more than 1/2" sag between supports or as required per local code. NOTE: Secure the duct so that clearance to the outer wrap of the fireplace is maintained.
• Tape all seams with aluminum tape (1-1/4" minimum width or as specified by local codes).
If the fan is going to be mounted to the main return plenum of the furnace system (pull system):
• Remove the knockout from the side of the fireplace and discard it.
• Center the flex duct collar (the collar with a crimped end) around the exposed hole and attach it to the fireplace with 3 screws. NOTE: Do this BEFORE final positioning of the fireplace (see Figure 2).
• Cut a round 6” hole into the
KNOCKOUT
main return plenum of the fur­nace ductwork. Mount the fan duct collar onto the main re­turn plenum of the furnace ductwork and secure with three
DUCT COLLAR
screws.
• Slide the fan duct assembly onto the collar and secure with three screws. The arrow on the duct should point to­wards the return plenum. Spin the fan blades and check for obstructions.
• Connect the fan duct with
the flex duct collar using the flex duct provided. NOTE: The flex duct has a zero clearance to combustible construction.
• Support duct at intervals of no less than four feet with no more than 1/2" sag between supports or as required by local codes.
• Tape all seams with aluminum tape (1-1/4" minimum width or as specified by local codes).
NOTE: The fan duct assembly may be mounted anywhere in the flex duct run that may be convenient. The fan duct collar may need to be crimped to accept the flex ducting. Take care to secure the fan against nuisance vibration. Tape all seams with aluminum tape.