GFK-160T Fan System
CORD
FAN
TEMPERATURE
SENSOR
SWITCH
SPEED
CONTROL
CONTROL
NUT
CONTROL
KNOB
WIRE
LEAD
6’
WIRE
LEAD
GROMMET
6’
JUMPER
WIRE
- Installation and Operating Instructions -
Leave this manual with party responsible for use
and operation.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
Note: For ease of installation install Fan Kit prior to
gas line installation.
1. Introduction
The GFK-160T Fan has been designed to circulate
room air through the replace to enhance heat output.
The GFK-160T fan system operates on 120 VAC, 60 Hz
power. This is available through a receptacle in the factory installed junction box. The junction box is located in
the controls compartment of the replace.
A variable speed control is provided with the fan system
to provide quiet forced air ow at the desired speeds. A
temperature sensor switch, which automatically turns the
fan ON/OFF, is also provided with this kit. This kit may also
be installed for use with the optional IFT-RC400 remote
and auxiliary control module kit.
2. Kit Contents
Remove and verify contents from packaging before
beginning installation. See Figure 1.
3. Installation Precautions
The GFK-160T Fan Kit is tested and safe when installed in
accordance with this installation manual. It is your responsibility to read all instructions before starting installation and
to follow these instructions carefully during installation to as-
sure maximum benet from, and safe operation of, the fan.
This fan is carefully engineered and must be installed only
as specied. If you modify it or any of its components, you
may cause a re hazard and will void the WARRANTY. In
addition, such action may void the coverage provided by
the owner's home insurance.
NOTE: This fan kit is not approved for installation with the use of the TWI-MOD decorative
barrier front.
CAUTION: All wiring should be done by a qualied electrician and shall be in compliance with local codes and with
the National Electric Code ANSI/NFPA NO. 70-current (in
the United States), or with the current CSA C22.1 Canadian
Electric Code (in Canada).
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch.
• Incorrect wiring will damage this valve.
• Incorrect wiring will override IPI safety lockout.
CAUTION! Do not install damaged components.
If any parts are missing or damaged, contact your dealer before
starting installation. DO NOT install a damaged kit.
Heat & Glo Lifestyle Collection • GFK-160T Instructions • 2087-023 Rev. F • 2/21
Figure 1 Components of Fan Kit
1
4. Installation Instructions
A. installing the Fan
Position the fan all the way to the left side of the replace
and center front to back. Pull the fan 1/8 inch to 1/4 inch
away from the side wall of the replace. See Figure 2.
Note: For wiring information see following pages.
B. installing the Fan
If the available IFT-RC400 IntelliFire Touch® Remote
Control & Auxiliary Control Module Kit is to be install to
control the fan, the temp sensor switch and speed sensor will be installed.
Proceed to Section 4.E.
Figure 2 Fan Location
2
1/8” TO 1/4”
FIREPLACE
WALL
BLOWER