Health O Meter 3001KL-AMX User Instructions

Model 3001KL-AM/3001KL-AMX
Antimicrobial Digital Platform Scale
User Instructions
1
Model 3001KL-AM/3001KL-AMX
Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training.
TABLE OF CONTENTS
Cautions and Warnings ............................................................................................. 3
Specifications ............................................................................................................ 4
Certifications / Connectivity / Disposal ...................................................................... 5
Assembly Instructions .............................................................................................. 6
Set-up Instructions ................................................................................................... 10
Operating Instructions ............................................................................................... 11
Maintenance .............................................................................................................. 15
Calibration....…………………………………..………………………………..…………...16
Troubleshooting …………………………………………………………………………….17 Warranty..…………………………………………………………………………………….18
Note: This scale has been factory calibrated, and does not require calibration prior to use.
Please register your scale for warranty coverage at:
www.homscales.com
For User Instructions updates and revisions please go to:
www.homscales.com
2
CAUTIONS AND WARNINGS
To prevent patient/caregiver injury or damage to your scale, please follow the instructions in this user manual very carefully.
Do not exceed the weight capacity specified for this scale. For accurate weighing, this scale must be placed on a flat, stable surface. For accurate weighing, verify before each use the proper operation according to the
procedure described in this manual.
Do not use in the presence of flammable or explosive materials. If the scale becomes damaged, it should not be operated until properly serviced. Do not transport the scale with a patient or object on the scale. To prevent injury and damage to your scale, do not drop or mishandle scale, while using or
transporting scale.
Ensure that the AC adapter and scale do not come in contact with liquids, excessive
temperature, or excessive humidity.
Patient/caregiver safety
This scale is designed for static weighing of patients only. No scale should be used for
patient transfer.
To prevent patient injury, the patient must be attended throughout the entire weighing event.
Exercise caution when rolling patient onto and off of the scale.
When operating the scale with the AC adapter:
Operate this scale exclusively with the AC adapter that is provided (ADPT30). Use of an
unspecified adapter will void the warranty, and can pose a serious safety hazard.
Prior to using this scale, inspect the AC adapter cord for cracking / fraying, or for broken /
bent plug prongs.
Prior to using this scale, ensure that the AC adapter is plugged into an outlet with the rated
voltage appropriate for operation.
Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power
source.
Unplug the AC adapter, and carefully store both the adapter and adapter cord before moving
the scale.
Operating this scale at voltages and frequencies other than specified can damage the
equipment and will void the warranty.
When operating the scale with batteries:
For accurate weighing, if the “LO BAT” indicator activates, replace the batteries or switch to
the AC adapter as soon as possible.
When replacing / inserting batteries, be sure to use all new batteries.
This equipment has been tested and found to comply with the EMC limits for the Medical Device Directive 93/42/EEC (EN 55011 Class A and EN 60601-1-2). These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. The equipment generates, uses and may radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to other devices in the vicinity. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference with other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to eliminate the interference by one or more of the following measures:
Reorient or relocate the receiving device.  Increase the separation between the equipment.  Connect the equipment into an outlet on a circuit different from that to which the other device(s) is
connected.
Consult Customer Service or a field service technician for help. In no event shall Pelstar, LLC be liable for damages or injuries whatsoever arising out of or connected with the assembly, use, or
misuse of its products.
3
Capacity and Resolution
1000 lb x 0.2 lb (454 kg x 0.1 kg)
Power Requirements
110-240VAC, 50-60Hz to 9V DC Adapter, ADPT30, (not included) or 6 AA batteries (included)
Environmental
Operating temperatures: 50°F to 95°F (10°C to 35°C) Storage temperatures: 30°F to 125°F (0°C to 50°C) Maximum Humidity: 85% RH
Platform Dimensions
Length: 15 3/4” (46 cm)
Width: 22” (56 cm) Height: 2 5/8” (6 cm)
SPECIFICATIONS
General
Model 3001KL-AM/3001KL-AMX digital scales use highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. This scale uses motion-sensing weighing technology in order to determine the actual weight of a moving patient.
Although the patient’s weight can be displayed in either pounds (LB) or kilograms (KG), the scale can be “locked” such that the user cannot change the displayed Unit of
Measurement (UOM). Note: The scale is shipped from the factory locked in “KG” mode. Refer to Page 12 to
learn more about configuring the scale.
Antimicrobial Powder Coating
Unique to the 3001KL-AM/3001KL-AMX scales, the handrails and transport handle have been fabricated with a permanent, antimicrobial powder coating. The antimicrobial coating utilizes silver ionic technology to inhibit the growth of microbes.
Scale Specifications
4
CERTIFICATIONS / CONNECTIVITY / DISPOSAL
Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems.
This product is tested to and meets the requirements of:
1. UL60601-1 First Edition: Safety for Medical Electrical Equipment
2. CSA C22.2 No. 601-1 M90: Medical Electrical Equipment
Certification Descriptions
Connectivity Information
To enable reliable transmission of weight, height, and Body Mass Index (BMI) data, this scale is designed to connect to a computer, monitor, or other electronic device via a built-in USB port. This connectivity helps minimize transcription errors when recording patient data.
This scale is EMR-EHR compatible. For more information regarding how to connect this scale to other electronic devices, please contact Health o meter® Professional Scales Technical Support, available during normal business hours at 1-800-638-3722.
Scale Disposal
This Health o meter® Professional scale must be disposed of properly as electronic waste. Follow the national, regional or local regulations which apply to you for disposal of electronic waste or batteries. Do not dispose of this device in the domestic waste stream.
5
ASSEMBLY INSTRUCTIONS
3001KL-AM Handrails
3001KL-AMX Handrails
*If you have received your scale already assembled, skip to Set Up Instructions on page 10.
Before Assembly
Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly.
To prevent scratching any components, carefully remove each assembly from the carton and unwrap the packing materials. Set the carton aside for storage. To avoid damaging the scale parts when unpacking, do not use a box cutter, knife, scissors, or any sharp object to open the protective inner packaging.
Parts List
(1) Scale platform (1) Handrail (with load cell connector cable inside) (1) Display Head (1) AC Adapter Holder (4) Feet (8) M8x20 bolts (4) Machine screws (2) Sheet metal screws
Tools Required
13 mm box wrench, Phillips head screwdriver
Note: Assembly photos in this User Instruction manual depict the gray handrails on scale model 3001KL-AM. Assembly instructions are the same for scale model 3001KL-AMX. Handrails for the 3001KL-AMX are the white handrails depicted below.
6
Loading...