Health O Meter 3001KL-AM, 3001KL-AMC User Instructions

Model 3001KL-AM/3001KL-AMC
Antimicrobial Digital Platform Scale
User Instructions
P/N UM3001KL-AM Rev20160407
1
Model 3001KL-AM/3001KL-AMC
Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training.
TABLE OF CONTENTS
Caution and Warning................................................................................................. 3
Specifications for This Scale ..................................................................................... 4
Certifications / Connectivity / Disposal ...................................................................... 5
Assembly Instructions 3001KL-AM/3001KL-AMC Scale .......................................... 6
Setup / Batteries ....................................................................................................... 8
Quick Start Instructions ............................................................................................. 9
Unit of Measurement (UOM) Configuration ............................................................... 13
Maintenance .............................................................................................................. 14
Calibration....…………………………………..………………………………..…………...15
Troubleshooting …………………………………………………………………………….16
Warranty..…………………………………………………………………………………….17
Note: This scale has been factory calibrated, and does not require calibration prior to use.
Please register your scale for warranty coverage at:
http://www.homscales.com
For User Instructions updates and revisions please go to:
http://www.homscales.com
CAUTION AND WARNING
To prevent injury and damage to your scale, please follow these instructions very carefully.
Assemble and operate the scale per the enclosed user instructions.
Do not transport the scale with any weight on the platform.
Do not exceed weight limit of 1000 lb / 454 kg for this scale.
For accurate weighing, this scale must be placed on a flat, stable surface.
For accurate weighing, verify before each use the proper operation
according to the procedure described in this manual.
Do not use in the presence of flammable or explosive materials.
For accurate weighing, if the “Lo bAtt” indicator activates, replace the batteries or switch to the AC adapter as soon as possible.
adapter not available on 3001KL-AMC model.
When replacing / inserting batteries, be sure to use all new batteries.
To prevent patient injury, the patient must be attended throughout the
entire weighing event.
Note: Use of AC
Patient should wear socks or other form of lightweight foot covering during weighing event.
Using the Scale with the Optional AC Adapter
Note: Use of AC adapter not available on 3001KL-AMC model.
If applicable, operate this scale exclusively with the AC adapter provided by Health o meter® Professional. Use of an unspecified adapter will void the warranty, and can pose a serious safety hazard.
Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty.
Prior to using this scale, inspect the AC adapter cord for cracking / fraying, or for broken / bent plug prongs.
Prior to using this scale, ensure that the AC adapter is plugged into an outlet with the rated voltage appropriate for operation.
Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power source.
Unplug the AC adapter, and carefully store both the adapter and adapter cord before moving the scale.
Ensure that the AC adapter and scale do not come in contact with liquids, excessive temperature, or excessive humidity.
If the scale is being connected to another medical device, the power adapter must not be used. Disconnect the power adapter from the scale and use only the battery power.
SPECIFICATIONS FOR THIS SCALE
General
The Model 3001KL-AM/3001KL-AMC digital scale uses highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. This scale uses motion-sensing weighing technology in order to determine the actual weight of a moving patient.
Although the patient’s weight can be displayed in either pounds (LB) or in kilograms (KG), the scale can be “locked” such that the user cannot change the displayed Unit of Measurement (UOM).
Note: The 3001KL-AM/3001KL-AMC scale is shipped from the factory locked in “KG” mode. Refer to Page 13 to learn more about configuring the scale.
Antimicrobial Powder Coating
Unique to the 3001KL-AM/3001KL-AMC scale, the handrails and transport handle have been fabricated with a permanent, antimicrobial powder coating. The antimicrobial coating utilizes silver ionic technology to inhibit the growth of microbes.
This scale can be powered using 6 AA batteries (included). An optional 120V Adapter is available in USA only, ADPT30.
Note: Use of AC adapter not available on 3001KL-AMC model.
3001KL-AM Scale Specifications
Capacity and Resolution
Power Requirements
Environmental
Physical Dimensions
1000 lb x 0.2 lb (454 kg x 0.1 kg)
110-240VAC, 50-60Hz to 9V DC Adapter (not available on 3001KL-
AMC model), or 6 AA batteries
Operating temperatures: 50°F to 95°F (10°C to 35°C)
Storage temperatures: 30°F to 125°F (0°C to 50°C)
Maximum Humidity: 85% RH
Platform
Length: 15 3/4” (46 cm)
Width: 22” (56 cm)
Height: 2 5/8” (6 cm)
Assembled Size and Weight
Length: 32” (81 cm)
Width: 22” (56 cm)
Height: 48” (122 cm)
Weight: 42 lb (19 kg)
CERTIFICATIONS / CONNECTIVITY / DISPOSAL
Certification Descriptions
Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems.
Connectivity Information
To enable reliable transmission of weight, height, and Body Mass Index (BMI) data, this scale is designed to connect to a computer, monitor, or other electronic device via a built-in USB port. This connectivity helps minimize transcriptions errors when recording patient data.
This scale is EMR-EHR compatible. For more information regarding how to connect this scale to other electronic devices, please contact Health o meter® Professional Scales Technical Support, available during normal business hours at 1-800-638-3722.
Scale Disposal
This Health o meter® Professional scale must be disposed of properly as electronic waste. Follow the national, regional or local regulations which apply to you for disposal of electronic waste or batteries. Do not dispose of this device in the domestic waste stream.
3001KL-AM/3001KL-AMC ASSEMBLY INSTRUCTIONS
Before Installation
Each 3001KL-AM/3001KL-AMC Antimicrobial scale is shipped for immediate use inside a single carton. Carefully inspect the outside carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package.
The following information will detail what you will find inside the main carton as you unpack. To prevent damage to the scale, carefully remove the unit from the carton and remove all packing materials. Set the carton aside for storage. To avoid scratching any of the scale parts when unpacking, do not use a box cutter, knife, scissors, or any sharp object to open the protective packaging.
Parts List
3001KL-AM/3001KL-AMC Scale, Fully Assembled
Directions for Use (located in enclosed envelope)
Quick Reference Guide (located in enclosed envelope)
(6) AA Batteries
Tools Required
Phillips head screwdriver (not included) to install batteries.
Setting up the 3001KL-AM/3001KL-AMC Scale (Refer to Figures 1-2)
Caution: It is recommended that the scale setup be performed by two persons.
Warning: Do not drop scale, as this can permanently damage the load cells.
1. Remove the fully assembled scale by carefully lifting it out from the carton and place scale platform on a flat, level, and dry surface.
2. Carefully remove the batteries, wrapped inside bubble wrap. The batteries are attached to the upper handrail.
3. Remove the protective plastic film covering the display (the film is printed “FACTORY CALIBRATED”).
4. Place batteries into the battery holder, located on the side of the display assembly (see “Replacing / Inserting Batteries” information below).
5. For the 3001KL-AM model only, connect the AC adapter into the adapter jack (the jack is located on the rear of the display assembly). Plug the scale’s AC adapter into the power source.
Note: Use of AC adapter not available on 3001KL-AMC model.